Citations

Clear

3035 citation(s) found for "Ma, Kevin".

A Comprehensive Approach to Pouch Disorders
Quinn, Kevin P. , Faubion, William A. , Raffals, Laura E., Lightner, Amy L. , Raffals, Laura E.

Mayo Clinic

Inflammatory Bowel Diseases | August 16, 2018 | Volume: 25 | Issue: 3 | Pages: 460-471

10.1093/ibd/izy267 | PMID 30124882 Get It

Teaching NeuroImages: Cerebral liposuction
Gobeske, Kevin T. , Maltais, Simon, Cloft, Harry J. , Wijdicks, Eelco F. M.

Mayo Clinic

Neurology | August 13, 2018 | Volume: 91 | Issue: 7 | Pages: No page available

10.1212/wnl.0000000000005999 | PMID 30104235 Get It

Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

Mayo Clinic

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
Acute serous tamponade after paraesophageal hernia repair reoperation
Makey, Ian A. , Beers, Kevin , Eilers, Amanda L., Thomas, Mathew

Mayo Clinic

BMJ Case Reports | August 9, 2018 | Volume: 2018 | Issue: No issue available | Pages: bcr-2018-225466

10.1136/bcr-2018-225466 | PMID 30093469 Get It

Cardiac tamponade is a common complication after cardiac surgery and is usually caused by bleeding or thrombus in the early postoperative period. Postoperative serous tamponade is more rare and usually of gradual onset. We report an unusual and life-threatening case of serous tamponade occurring on postoperative day 1 following a third-time paraesophageal hernia repair.
Identification and Characterization of a Phase-Variable Element That Regulates the Autotransporter UpaE in Uropathogenic Escherichia coli
Battaglioli, Eric , Goh, Kelvin G. K. , Atruktsang, Tashi, Schwartz, Kevin J., Schembri, Mark A. , Welch, Rodney A. , Schembri, M A , Welch, R A

Mayo Clinic

mBio | August 6, 2018 | Volume: 9 | Issue: 4 | Pages: No page available

10.1128/mbio.01360-18 | PMID 30087170 Get It

ABSTRACT Uropathogenic Escherichia coli (UPEC) is the most common etiologic agent of uncomplicated urinary tract infection (UTI). An important mechanism of gene regulation in UPEC is phase variation that involves inversion of a promoter-containing DNA element via enzymatic activity of tyrosine recombinases, resulting in biphasic, ON or OFF expression of target genes. The UPEC reference strain CFT073 has five tyrosine site-specific recombinases that function at two previously characterized promoter inversion systems, fimS and hyxS . Three of the five recombinases are located proximally to their cognate target elements, which is typical of promoter inversion systems. The genes for the other two recombinases, IpuA and IpuB, are located distal from these sites. Here, we identified and characterized a third phase-variable invertible element in CFT073, ipuS , located proximal to ipuA and ipuB . The inversion of ipuS is catalyzed by four of the five CFT073 recombinases. Orientation of the element drives transcription of a two-gene operon containing ipuR , a predicted LuxR-type regulator, and upaE , a predicted autotransporter. We show that the predicted autotransporter UpaE is surface located and facilitates biofilm formation as well as adhesion to extracellular matrix proteins in a K-12 recombinant background. Consistent with this phenotype, the ipuS ON condition in CFT073 results in defective swimming motility, increased adherence to human kidney epithelial cells, and a positive competitive kidney colonization advantage in experimental mouse UTIs. Overall, the identification of a third phase switch in UPEC that is regulated by a shared set of recombinases describes a complex phase-variable virulence network in UPEC. IMPORTANCE Uropathogenic Escherichia coli (UPEC) is the most common cause of urinary tract infection (UTI). ON versus OFF phase switching by inversion of small DNA elements at two chromosome sites in UPEC regulates the expression of important virulence factors, including the type 1 fimbria adhesion organelle. In this report, we describe a third invertible element, ipuS , in the UPEC reference strain CFT073. The inversion of ipuS controls the phase-variable expression of upaE , an autotransporter gene that encodes a surface protein involved in adherence to extracellular matrix proteins and colonization of the kidneys in a murine model of UTI.
Sirt6 deficiency impairs corneal epithelial wound healing
Zhu, Shuang , Miller, Jordan D. , Merkley, Kevin H., Tilton, Ronald G. , Liu, Hua , Hu, Xiaobing, Liu, Rong , Miller, Jordan

Mayo Clinic

Aging | August 2, 2018 | Volume: 10 | Issue: 8 | Pages: 1932-1946

10.18632/aging.101513 | PMID 30070973 Get It

Extensor Mechanism Reconstruction with Use of Marlex Mesh
Abdel, Matthew P. , Salib, Christopher G. , Mara, Kristin C. , Pagnano, Mark W. , Perry, Kevin I. , Hanssen, Arlen D. , Mara, Kristin C. , Abdel, Matthew P , Mara, Kristin C , Mara, Kristin C.

Mayo Clinic

Journal of Bone and Joint Surgery | August 1, 2018 | Volume: 100 | Issue: 15 | Pages: 1309-1318

10.2106/jbjs.17.01165 | PMID 30063593 Get It

Background: Disruption of the extensor mechanism after total knee arthroplasty (TKA) is debilitating, and the reported results of numerous reconstructive options have varied. We previously reported the early results of 13 patients who underwent reconstruction of the extensor mechanism with use of Marlex mesh. The purpose of the current study was to assess results in a larger cohort of patients, with an emphasis on the survivorship of the mesh, clinical results, and complications. Methods: During the period of 2000 to 2015 at a single tertiary care academic institution, 77 patients (77 TKAs) underwent reconstruction with use of Marlex mesh for an extensor mechanism disruption (27 quadriceps tendon disruptions, 40 patellar tendon disruptions, and 10 patellar fractures). The mean patient age at the time of reconstruction was 65 years; 70% of the patients were female. The mean body mass index was 35 kg/m 2 . The mean follow-up was 4 years. Eighteen (23%) of the patients underwent mesh reconstruction with the primary TKA in place, and 59 (77%) had mesh reconstruction at the time of revision TKA. The mean time between disruption and reconstruction was 7 months. Twenty (26%) of the patients had previously undergone attempted extensor mechanism reconstruction at outside institutions. Results: Sixty-five of the 77 mesh reconstructions were in place at the time of the latest follow-up. Twelve patients experienced a failure that required mesh revision: 5 for patellar tendon rupture, 5 for quadriceps tendon rupture, and 2 for symptomatic lengthening. Four additional patients with mesh failure were treated nonoperatively with bracing. The 2-year survivorship free of mesh revision was 86% for patients with no prior reconstruction and 95% for patients with previous reconstructions of the extensor mechanism that did not involve Marlex mesh. Knee Society Score (KSS) results significantly improved following reconstruction (p < 0.001). Extensor lag improved by a mean of 26°, with mean postoperative extensor lag measuring 9° (p < 0.001). Conclusions: Reconstruction of the extensor mechanism with use of Marlex mesh is a viable option in patients with catastrophic disruption after TKA. At the time of the latest follow-up, 84% of the mesh reconstructions were in place and the functional outcomes were excellent, with mean improvement in extensor lag of 26°. Extended follow-up is required, but the results of this large series with a mean follow-up of 4 years are encouraging. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Tension-Controlled Active Compression Garment for Treatment of Orthostatic Intolerance
Pettys‐Baker, Robert, Schleif, Nicholas, Lee, J. Walter, Utset-Ward, Sophia, Berglund, Mary Ellen, Dunne, Lucy E. , Holschuh, Brad , Kelly, Kevin L. , Johnson, Bruce , Joyner, Michael J. , Joyner, Michael J , Johnson, Christopher D.

Mayo Clinic

2018 Design of Medical Devices Conference | July 30, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2018-6884 Get It

Medical compression garments are used to treat lymphatic disorders or conditions of poor venous return (e.g. orthostatic intolerance). Conventional compression garments, namely elastic compression sleeves and inflatable compression systems, may aid in relief of these conditions but are also limited in usability. Fixed levels of compression in elastic materials may induce challenges in donning/doffing, complicating patient compliance [1]. Compression levels in inflatable systems are customizable, but these garments are also bulky and require a tethered inflation source [2]. We are interested in developing easy-to-don/-doff compression garments using shape memory alloy (SMA) coil actuators that contract with heat from an applied current which can be wrapped around the body to apply compressive forces. More specifically, we use a spring coil formation as described by Holschuh et al. [3]. Further developed in the Wearable Technology Lab at the University of Minnesota, our current SMA compression garment (SMA-CG) design improves upon the work of Duvall et al. [4] presented in previous year’s (2017) Design of Medical Devices Conference, representing a year’s evolution in active compression garment design that integrate actuators made with SMA.
The role of the paravertebral ganglia in human sympathetic neural discharge patterns
Klassen, Stephen A. , Limberg, Jacqueline K. , Baker, Sarah E. , Nicholson, Wayne T. , Curry, Timothy B. , Shoemaker, J. Kevin , Shoemaker, J Kevin , Baker, Sarah E , Klassen, Stephen A , Joyner, Michael J.

Mayo Clinic

The Journal of Physiology | July 28, 2018 | Volume: 596 | Issue: 18 | Pages: 4497-4510

10.1113/jp276440 | PMID 30054928 Get It

Key PointsThe mechanisms affecting recruitment patterns of postganglionic sympathetic nerves remain unclear. The divergent and convergent preganglionic innervation patterns of postganglionic neurons and the presence of differently sized postganglionic nerves suggest that the ganglia may participate in modifying the discharge patterns of single sympathetic postganglionic neurons innervating the skeletal muscle circulation.Whether the ganglia affect the ordered behaviour of varying sized postganglionic sympathetic neurons in humans has not been studied.Trimethaphan infusion produced an ordered pattern of action potential (AP) de‐recruitment whereby the firing of larger, low probability APs present at baseline was abolished first, followed by progressive decreased probability of smaller APs. Although integrated sympathetic bursts were no longer detected after several minutes of trimethaphan, firing of the smallest APs was detected.These data suggest the ganglia affect the distribution of firing probabilities exhibited by differently sized sympathetic neurons.The ganglia may contribute to sympathetic neural emission patterns involved in homeostatic regulation.AbstractDo the ganglia contribute to the ordered behaviour of postganglionic neuronal discharge within the sympathetic nervous system? To further understand the functional organization of the sympathetic nervous system we employed the microneurographic approach to record muscle sympathetic nerve activity (MSNA) and a continuous wavelet transform to study postganglionic action potential (AP) behaviour during nicotinic blockade at the ganglia (trimethaphan camsylate, 1–7 mg min−1) in seven females (37 ± 5 years). Trimethaphan elicited a progressive reduction in sympathetic outflow characterized by fewer integrated bursts with decaying amplitude. Underlying trimethaphan‐mediated attenuations in integrated MSNA were reductions in AP incidence (186 ± 101 to 29 ± 31 AP (100 beats)−1) and AP content per integrated burst (7 ± 2 to 3 ± 1 APs burst−1) (bothP <0.01) in the final minute of detectable bursting activity in the trimethaphan condition, compared to baseline. We observed an ordered de‐recruitment of larger to smaller AP clusters active at baseline (14 ± 3 to 8 ± 2 active AP clusters,P <0.01). Following cessation of integrated bursts in the trimethaphan condition, the smallest 6 ± 2 sympathetic AP clusters persisted to fire in an asynchronous pattern (49 ± 41 AP (100 beats)−1) in all participants. Valsalva's manoeuvre did not increase the incidence of these persistent APs (60 ± 42 AP (100 beats)−1,P = 0.52), or recruit any larger APs in six of seven participants (6 ± 1 total AP clusters,P = 0.30). These data suggest that the ganglia participate in the ordered recruitment of differently sized postganglionic sympathetic nerves.
Balloon Catheter Sinuplasty in Young Children
Ramadan, Hassan H. , McLaughlin, Kevin, Rimell, Frank L., Bent, John P. , Parikh, Sanjay R., Josephson, Gary D.

Mayo Clinic

American Journal of Rhinology & Allergy | July 27, 2018 | Volume: 24 | Issue: 1 | Pages: e54-e56

10.2500/ajra.2010.24.3431a Get It

Background Balloon catheter sinuplasty (BCS) for chronic rhinosinusitis (CRS) was found to be successful in adults. The safety and feasibility of BCS in children has been recently established. The purpose of this study was to study the outcome of this technology in CRS in children. Methods A prospective, multicenter, nonrandomized evaluation was performed on patients with CRS. Thirty-two children between the ages of 2 and 11 years were enrolled. Safety was assessed by rate of adverse events. Effectiveness was assessed using the Sino-Nasal (SN)-5 quality-of-life questionnaire for children with CRS at 52 weeks follow-up. Results Thirty-two children were enrolled of which 24 completed their 52 weeks follow-up. No adverse events were reported because of the procedure. SN-5 score improved from a mean of 4.9 at baseline to a mean of 2.95 at 52 weeks (p < 0.0001). Twelve (50%) children had a significant improvement of their SN-5 (> – 1.5), 7 (29%) had moderate improvement (> –1.0 and < –1.5), 2 (8%) had mild improvement (> –0.5 and < –1.0), 1 (4%) remained the same, and 2 (8%) had worsening scores. Conclusions Balloon catheter dilation of the sinus ostia in children was safe and a significant number showed improvement of their SN-5 at 1 year follow-up. Additional studies comparing balloon sinuplasty to other modalities of treatment in children are needed to determine its efficacy in the treatment of CRS in children.