Citations

Clear

217 citation(s) found for "Pislaru, S V".

The Learning Curve for Transcatheter Mitral Valve Repair With MitraClip
Eleid, Mackram F. , Reeder, Guy S., Malouf, Joseph F., Lennon, Ryan J. , Pislaru, Sorin V. , Nkomo, Vuyisille T., Rihal, Charanjit S. , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Sabbah, Michael S.

Mayo Clinic

Journal of Interventional Cardiology | July 28, 2016 | Volume: 29 | Issue: 5 | Pages: 539-545

10.1111/joic.12326 | PMID 27696544 Get It

ObjectivesThis study sought to assess the learning curve for TMVR for treatment of primary mitral regurgitation (MR).BackgroundData are lacking regarding the technical experience required to achieve optimal clinical outcomes with transcatheter mitral valve repair (TMVR) using the edge‐to‐edge MitraClip technique.MethodsWe examined the sequential experience of the first 75 patients (age 80 ± 9 years; 77% male) who underwent TMVR at our institution. A sequence number of each patient was assigned as a continuous variable and in tertiles for analysis.ResultsTMVR with MitraClip was successful in 97% with an average procedural time of 106 ± 39 minutes. The 30‐day rate of major adverse cardiovascular events was 7%. With increased case experience, there were decreases in procedural time, fluoroscopy time, length of hospital stay, and major adverse cardiovascular events. Procedural success, residual mitral regurgitation and NYHA functional classification at 30‐day follow‐up remained unchanged throughout the experience.ConclusionsThe learning curve for TMVR with MitraClip for treatment of primary MR is characterized by a sequential reduction in procedure time, fluoroscopy time, procedural complications, and hospital length of stay at a tertiary academic medical center. Thirty‐day procedural results are favorable and similar during the initial learning period.
The spectrum of low-output low-gradient aortic stenosis with normal ejection fraction
Pislaru, Sorin V. , Pellikka, Patricia A. , Sabbah, Michael S. , Pellikka, Patricia A

Mayo Clinic

Heart | February 14, 2016 | Volume: 102 | Issue: 9 | Pages: 665-671

10.1136/heartjnl-2015-307893 | PMID 26822426 Get It

Low-flow, low-gradient (LF/LG) severe aortic stenosis (AS) with preserved ejection fraction refers to the condition of AS with aortic valve area ≤1 cm2, stroke volume index <35 mL/m2, mean aortic valve gradient <40 mm Hg and left ventricular ejection fraction ≥50%. This mismatch of aortic valve area suggesting severe stenosis and ‘low’ gradient in some patients has led to confusion as to the severity of stenosis. Conditions previously labelled as LF/LG severe AS include a spectrum, with measurement error probably being the most common cause of marked inconsistency between gradient, valve area and patient presentation. The presence of LG severe AS may be overestimated in petite patients, who may have aortic valve area slightly less than 1 cm2 with only moderate AS. Concomitant cardiac conditions besides AS, including significant mitral and tricuspid regurgitation, intracardiac shunts and constrictive pericarditis, may contribute to reduced stroke volume, and evidence for these must be sought at the time of echocardiography. True LF/LG severe AS is associated with a unique and probably maladaptive remodelling pattern with smaller ventricles, increasing relative wall thickness, progressive worsening of diastolic function and higher afterload, as demonstrated by lower systemic arterial compliance, higher systemic vascular resistance and higher valvuloarterial impedance. Control of hypertension is essential to the appropriate management of patients with AS. Aortic valve replacement should be considered in patients with compelling evidence of severe AS who remain symptomatic despite optimal treatment of hypertension.
Advance Directives of Patients With High-Risk or Inoperable Aortic Stenosis
Suri, Rakesh M. , Pislaru, Sorin V. , Greason, Kevin L. , Mathew, Verghese, Rihal, Charanjit S. , Mueller, Paul S. , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Sabbah, Michael S.

Mayo Clinic

JAMA Internal Medicine | August 4, 2014 | Volume: 174 | Issue: 9 | Pages: 1516

10.1001/jamainternmed.2014.3453 | PMID 25089358 Get It

Long-Term Mortality Associated With Left Ventricular Dysfunction in Mitral Regurgitation Due to Flail Leaflets
Tribouilloy, Christophe, Ruşinaru, Dan, Grigioni, Francesco , Vanoverschelde, Jean‐Louis , Aviérinos, Jean-François , Barbieri, Andréa , Pislaru, Sorin V. , Russo, Antonio , Théron, Alexis , Szymanski, Catherine, Enriquez‐Sarano, Maurice , Mantovani, Francesca , Meester, Christophe de , Tribouilloy, Christophe , Michelena, Héctor I. , Pasquet, Agnès , Lévy, Franck , Sabbah, Michael S. , Enriquez-Sarano, Maurice , Mantovani, Francesca , Barbieri, Andrea , Vanoverschelde, Jean-Louis , Théron, Alexis , Grigioni, Francesco

Mayo Clinic

Circulation: Cardiovascular Imaging | December 21, 2013 | Volume: 7 | Issue: 2 | Pages: 363-370

10.1161/circimaging.113.001251 | PMID 24363357 Get It

Background— Ejection fraction (EF) as a marker of left ventricular (LV) dysfunction and the appropriate thresholds for diagnosing severe or mild/moderate LV dysfunction in mitral regurgitation are doubted and poorly followed in clinical practice. We aimed at assessing the role of EF in a large registry of organic mitral regurgitation to objectively establish thresholds for various degrees of LV dysfunction and to analyze whether mitral surgery remains beneficial in those subsets of patients. Methods and Results— We investigated the relation between EF and mortality in 1875 patients with mitral regurgitation due to flail leaflets in sinus rhythm (65±13 years; median EF, 66% [60%–71%]) enrolled in the Mitral Regurgitation International Database (MIDA) registry. With EF <60%, mortality after diagnosis increased precipitously under medical management (adjusted hazard ratio [HR], 1.59 [1.19–2.12]) and during the entire follow-up (adjusted HR, 1.51 [1.22–1.87]). Severe LV dysfunction, if defined by EF <30%, would affect a minuscule number of patients (0.3%). Conversely, EF <45% was more frequent (2.9%) and was associated with considerable mortality under medical management (adjusted HR, 2.43 [1.50–3.95]) and during the entire follow-up (adjusted HR, 2.46 [1.67–3.61]). The group with EF of 45% to 60% represented a large proportion of patients (23%), exhibited rarely overt symptoms, and had higher mortality compared with EF >60%. Above 60%, no EF threshold further determined survival. The benefit of surgery remained considerable in the groups with EF <45% (adjusted HR, 0.28 [0.17–0.56]) and with EF of 45% to 60% (adjusted HR, 0.34 [0.21–0.64]). Conclusions— EF is valuable in defining presence and severity of LV dysfunction in organic mitral regurgitation. Patients with EF <45% have severe LV dysfunction, catastrophic outcome under medical management, and should not be denied surgery. Although there is no survival gain with EF ranges >60%, with EF dropping <60%, mortality increases precipitously and prompt surgical referral is critical to outcome.
Robust shear wave motion tracking using ultrasound harmonic imaging
Zhao, Heng , Manduca, Armando, Kinnick, Randall R., Greenleaf, James F. , Song, Pengfei , Urban, Matthew W. , Pislaru, Sorin V. , Chen, Shigao

Mayo Clinic

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4010-4010

10.1121/1.4830628 Get It

Robust shear-wave motion detection is essential for producing reliable shear elasticity measurements for ultrasound shear-wave elastography (SWE). However, because shear-wave motion is extracted from radiofrequency signals which can be heavily contaminated by noise, shear-wave motion detection can be very challenging, especially for in vivo applications. This study investigated the implementation of harmonic imaging (HI) to facilitate more robust shear-wave tracking based on HI’s effectiveness in suppressing imaging noise associated with ultrasound reverberation, phase aberration, and clutter noise. A HI shear-wave tracking sequence was developed combining the pulse-inversion HI method with the plane wave imaging technique to transmit phase-inverted pulses at a high frame rate of several kilohertz. The backscattered ultrasound signals from phase-inverted pulses were added to suppress the fundamental and enhance the second harmonic component, from which the shear-wave motion was extracted. A pork belly phantom experiment showed that HI could significantly improve shear-wave motion detection by producing almost three-fold less underestimation of shear-wave motion and over ten-fold more precision for shear-wave speed measurements than fundamental imaging. An in vivo transthoracic case study of a human heart showed that HI substantially improved the success rate of shear-wave motion detection and could provide consistent estimates of the left ventricle myocardium stiffness.
In vivo noninvasive method for measuring local wave velocity in femoral arteries of pig
Kinnick, Randall R., Pislaru, Cristina , Greenleaf, James F. , Zhang, Xiaoming , Fatemi, Mostafa , Pislaru, Cristina

Mayo Clinic

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 2005-2005

10.1121/1.4785688 Get It

We have proposed generating a bending wave in the arterial wall using ultrasound radiation force and measuring the wave velocity along the arterial wall [Zhang et al., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 642–652 (2005)]. Here, we report the results of in vivo studies on pigs. The pig was anesthetized, and a micromanometer tip catheter was inserted into the femoral artery to measure luminal pressure. A water bath was created on the animal’s groin to allow unimpeded access of the ultrasound beams to the femoral artery. The femoral artery was first located using a 13-MHz linear-array transducer. Then, a vibro-acoustography image was obtained to ensure precise positioning of the excitation force relative to the artery. The artery was excited by the force transducer and the resulting vibration of the arterial wall was measured by a sensing Doppler transceiver. Measured wave velocity was 3.1 m/s at 300 Hz. With this new method wave velocity over a distance of 5 mm, and therefore stiffness of arteries, can be measured locally and non-invasively. Measurement time is short in a few tens of milliseconds, which allows pressure dependence and pharmacological effect on the wall properties to be measured at different cardiac times.
Ultrasound-enhanced gene transfer: Comparison of contrast agents and ultrasound modalities in vitro and in vivo
Gulati, Rajiv , Pislaru, Cristina , Kinnick, Randall R., Singh, Ripudamanjit, Greenleaf, James F. , Simari, Robert D., Pislaru, Sorin V. , Pislaru, Cristina

Mayo Clinic

The Journal of the Acoustical Society of America | October 21, 2013 | Volume: 112 | Issue: 5_Supplement | Pages: 2337-2337

10.1121/1.4779440 Get It

Ultrasound (US) enhancement of plasmid-based gene transfer is an emerging technique. Our hypothesis was that two contrast agents (Optison and PESDA), and two US exposure modalities (dedicated continuous wave system and diagnostic scanner) may have different effects. Luciferase plasmid with or without contrast agent was added to vascular smooth muscle cells and endothelial cells, followed by US exposure. Luciferase activity was measured 24 h later. US exposure consistently induced higher transfection rates than all controls. PESDA was superior to Optison in both cell lines. In vitro, continuous wave and diagnostic US were not significantly different. In vivo, Lux and PESDA were injected into skeletal muscles of rats (IM or intra-arterial) followed or not by US exposure. In separate animals, adenovirus encoding for luciferase was injected IM and was not followed by US exposure. Gene transfer efficacy was 8–10 fold higher with US and PESDA than with plasmid alone, but 2 fold lower than with adenovirus. However, as opposed to adenovirus, US-enhanced plasmid gene transfer was highly localized to the injected muscle, with no expression at distal sites. Our results support the hypothesis that contrast agents and exposure modalities are not equivalent with regard to gene transfer efficacy.
Real‐Time 3‐Dimensional Dynamics of Functional Mitral Regurgitation: A Prospective Quantitative and Mechanistic Study
Topilsky, Yan , Vaturi, Ori, Watanabe, Nozomi , Bichara, Valentina M., Mankad, Sunil , Park, Soon, Capps, Mary Ann, Suri, Rakesh M. , Pislaru, Sorin V. , Maalouf, Joseph F., Yoshida, Kiyoshi , Enriquez‐Sarano, Maurice , Nkomo, Vuyisile T. , Michelena, Héctor I. , Tourneau, Thierry Le , Sabbah, Michael S. , Enriquez-Sarano, Maurice , Topilsky, Yan

Mayo Clinic

Journal of the American Heart Association | June 1, 2013 | Volume: 2 | Issue: 3 | Pages: No page available

10.1161/jaha.113.000039 | PMID 23727698 Get It

Background Three‐dimensional transthoracic echocardiography (3D‐ TTE ) with dedicated software permits quantification of mitral annulus dynamics and papillary muscle motion throughout the cardiac cycle. Methods and Results Mitral apparatus 3D‐ TTE was acquired in controls (n=42), patients with left ventricle dysfunction and functional mitral regurgitation ( LVD ‐ FMR ; n=43) or without FMR ( LVD ‐no MR , n=35). Annulus in both normal and LVD ‐no MR subjects displayed saddle shape accentuation in early‐systole (ratio of height to intercommissural diameter, 10.6±3.7 to 13.5±4.0 in normal and 9.1±4.3 to 12.6±3.6 in LVD ‐no MR ; P <0.001 for diastole to early‐systole motion, P = NS between those groups). In contrast, saddle shape was unchanged from diastole in FMR patients (10.0±6.4 to 8.0±5.2; P = NS , P <0.05 compared to both other groups). Papillary tips moved symmetrically towards to the midanterior annulus in control and LVD ‐no MR subjects, maintaining constant ratio of the distances between both tips to midannulus (Pt AR ) throughout systole. In LVD ‐ FMR patients midsystolic posterior papillary tip to anterior annulus distance was increased, resulting in higher Pt AR ( P =0.05 compared to both other groups). Mechanisms of early‐ and midsystolic FMR differed between different etiologies of LV dysfunction. In patients with anterior MI and global dysfunction annular function and dilatation were the dominant parameters, while papillary muscle motion was the predominant determinant of FMR in patients with inferior MI . Conclusions Inadequate early‐systolic annular contraction and saddle‐shape accentuation in patients with impaired LV contribute to early–mitral incompetency. Asymmetric papillary tip movement towards the midanterior annulus is a major determinant of mid‐ and late‐systolic functional mitral regurgitation.
Quantifying viscoelasticity of boundary sensitive tissues using mechanical wave dispersion ultrasound vibrometry
Nenadic, Ivan , Pislaru, Cristina , Greenleaf, James F., Urban, Matthew W. , Bernal, Miguel , Pislaru, Cristina

Mayo Clinic

The Journal of the Acoustical Society of America | September 24, 2012 | Volume: 132 | Issue: 3_Supplement | Pages: 1981-1981

10.1121/1.4755308 Get It

The cardiovascular diseases such as atherosclerosis, coronary artery disease, hypertension and diastolic dysfunction have been associated with arterial stiffening and decreased ventricular compliance. Noninvasive techniques capable of quantifying elasticity and viscosity of cardiovascular tissues could facilitate early diagnosis and improve treatment. Here, we present a technique that uses focused ultrasound radiation force to excite mechanical waves in the tissue of interest and pulse echo to track the tissue deformation. Analysis of tissue deformation as a function of time using Fourier transforms allows calculation of the phase wave velocity dispersion (change of velocity as a function of frequency) of various modes of deformation. Continuum mechanics equations governing the motion of a viscoelastic plate and a tube are used to model the myocardial wall and arteries, respectively. Dispersion equations are derived for the two geometries and fit to the measured velocity dispersion to estimate tissue elasticity and viscosity. ECG-gated in vivo measurements of porcine myocardial and arterial elasticity and viscosity through a heart cycle are reported. The results show that both elasticity and viscosity increase during systole and decrease during diastole in the myocardium and arteries, consistent with underlying physiology.
Transthoracic in vivo measurements of porcine myocardial viscoelasticity using Lamb wave dispersion ultrasound vibrometry
Nenadic, Ivan , Greenleaf, J. F., Urban, Matthew W. , Pislaru, Cristina

Mayo Clinic

The Journal of the Acoustical Society of America | October 13, 2011 | Volume: 130 | Issue: 4_Supplement | Pages: 2461-2461

10.1121/1.3654884 Get It

Diastolic dysfunction is characterized by the stiffening of the left-ventricular myocardium. An imaging technique capable of quantifying viscoelasticity of the left-ventricle would aid clinicians in evaluating diastolic function. Lamb wave dispersion ultrasound vibrometry (LDUV) is an ultrasound-based method for measuring viscoelasticity of plate-like materials by exciting Lamb waves and measuring change of wave velocity as a function of frequency (dispersion). Lamb wave dispersion equation is fit to the dispersion data to estimate mechanical properties. We report in vivo transthoracic studies aimed at quantifying elasticity and viscosity of a beating porcine left-ventricle using LDUV. A single ultrasound probe operating at 5 MHz was used for impulse excitation in the myocardium and to track the wave motion. A Fourier space-time analysis of the motion was used to obtain Lamb wave velocity dispersion. ECG-gated transthoracic in vivo measurements of group velocity, elasticity, and viscosity throughout a single heart cycle were obtained. Group velocity, elasticity, and viscosity in the frequency range from 50 to 500 Hz increased by at least two-fold from diastole to systole, consistent with contraction and relaxation of the myocardium.