Citations

Clear

9551 citation(s) found for "James, EM".

Higher systolic and diastolic blood pressures in recently postmenopausal women are associated with greater WMH more than a decade later in the KEEPS Continuation
Tosakulwong, Nirubol , Lesnick, Timothy G. , Fought, Angela J. , Fields, Julie A. , Lowe, Val J. , Bailey, Kent R. , James, Taryn T. , Løbo, Rogerio A. , Hammers, Dustin B. , Cedars, Marcelle I. , Miller, Virginia M. , Harman, S. Mitchell , Gleason, Carey E. , Kara, Firat , Schwarz, Christopher G. , Senjem, Matthew L. , Min, Hoon-Ki Paul , Jack, Clifford R. , Manson, JoAnn E. , Pal, Lubna , Hammers, Dustin B , Malek‐Ahmadi, Michael , Naftolin, Frederick , Dowling, N. Maritza , Kantarci, Kejal

Mayo Clinic

Alzheimer's & Dementia | December 25, 2023 | Volume: 19 | Issue: S10 | Pages: No page available

10.1002/alz.081628 Get It

AbstractBackgroundHigher blood pressure (BP) is associated with greater white matter hyperintensity (WMH) volume, but research is limited in recently menopausal and postmenopausal women. Postmenopausal women have a greater burden of WMH than men and premenopausal women, but whether hormone therapy (HT) modifies the association between systolic and diastolic BP (SBP, DBP) and WMH is unknown. We investigated the association of SBP and DBP in recently postmenopausal women who participated in an HT trial with WMH volumes measured 14 years later and explored whether HT modified the results.MethodWomen with good cardiovascular (CV) health, who were previously enrolled in a randomized placebo‐controlled HT trial, the Kronos Early Estrogen Prevention Study (KEEPS), participated in the current observational KEEPS continuation (n = 212; median age = 67; range 58‐72). SBP and DBP were measured at KEEPS baseline (median age = 54 years; range 44‐59) and continuation. Antihypertensive users were excluded (baseline, n = 34; continuation, n = 61). Approximately 10 years after the end of KEEPS HT versus placebo 4‐year interventions, automated WMH volumes were measured from 3D‐FLAIR MRI. Associations of KEEPS baseline and continuation SBP and DBP with log WMH volume at KEEPS continuation were tested using linear regression analyses adjusting for covariates in model 1 (age, total intracranial volume, study site) and model 2 (model 1 plus cardiovascular risk factors (CVRF)).ResultHigher KEEPS baseline SBP and DBP were associated with greater WMH volume measured 14 years later, and after adjusting for CVRF (p = 0.01). Similarly, in KEEPS continuation, higher SBP and DBP were associated with greater WMH volume measured concurrently and after adjusting for CVRF (p<0.001). We did not find statistically significant evidence that HT versus placebo modified these associations. Topographically, higher SBP and DBP were associated with greater periventricular WMH in the frontal and parietal lobes after adjusting for age (Figure).ConclusionHigher SBP and DBP in recently menopausal women with good CV health were associated with greater WMH volumes more than a decade later after adjusting for CVRF, independent of randomization to HT. Our results show the importance of blood pressure control in recently menopausal women, that may reduce the white matter injury later in life.
Trial Readiness of Cavernous Malformations With Symptomatic Hemorrhage, Part II: Biomarkers and Trial Modeling
Hage, Stephanie , Kinkade, Serena , Flemming, Kelly D. , Kim, Helen , Torbey, Michel , Huang, Judy , Huston, John , Shu, Yunhong , Selwyn, Reed , Hart, Blaine L. , Feghali, James , Sair, Haris I. , Narvid, Jared , Lupo, Janine , Stadnik, Agnieszka , Hobson, Nicholas , DeBiasse, Dorothy , Lane, Karen , McBee, Nichole, Treine, Kevin, Ostapkovich, Noeleen , Wang, Ying, Thompson, Richard E. , Awad, Issam A. , Huston, John , Flemming, Kelly D , Kim, Helen , Torbey, Michel , Huang, Judy , Shu, Yunhong , Selwyn, Reed , Feghali, James , Narvid, Jared , Alcazar-Felix, Roberto J , Shenkar, Robert , Hobson, Nicholas , DeBiasse, Dorothy , Lane, Karen , Ostapkovich, Noeleen , Koenig, James I , Carroll, Timothy , Hanley, Daniel F , Awad, Issam , Girard, Romuald , Mabray, Marc C. , Lee, Justine C. , Alcazar‐Félix, Roberto J. , Shenkar, Robert , Koenig, James I. , Hanley, Daniel F.

Mayo Clinic

Stroke | December 22, 2023 | Volume: 55 | Issue: 1 | Pages: 31-39

10.1161/strokeaha.123.044083 | PMID 38134265 Get It

BACKGROUND: Quantitative susceptibility mapping (QSM) and dynamic contrast-enhanced quantitative perfusion (DCEQP) magnetic resonance imaging sequences assessing iron deposition and vascular permeability were previously correlated with new hemorrhage in cerebral cavernous malformations. We assessed their prospective changes in a multisite trial-readiness project. METHODS: Patients with cavernous malformation and symptomatic hemorrhage (SH) in the prior year, without prior or planned lesion resection or irradiation were enrolled. Mean QSM and DCEQP of the SH lesion were acquired at baseline and at 1- and 2-year follow-ups. Sensitivity and specificity of biomarker changes were analyzed in relation to predefined criteria for recurrent SH or asymptomatic change. Sample size calculations for hypothesized therapeutic effects were conducted. RESULTS: We logged 143 QSM and 130 DCEQP paired annual assessments. Annual QSM change was greater in cases with SH than in cases without SH ( P =0.019). Annual QSM increase by ≥6% occurred in 7 of 7 cases (100%) with recurrent SH and in 7 of 10 cases (70%) with asymptomatic change during the same epoch and 3.82× more frequently than clinical events. DCEQP change had lower sensitivity for SH and asymptomatic change than QSM change and greater variance. A trial with the smallest sample size would detect a 30% difference in QSM annual change during 2 years of follow-up in 34 or 42 subjects (1 and 2 tailed, respectively); power, 0.8, α=0.05. CONCLUSIONS: Assessment of QSM change is feasible and sensitive to recurrent bleeding in cavernous malformations. Evaluation of an intervention on QSM percent change may be used as a time-averaged difference between 2 arms using a repeated measures analysis. DCEQP change is associated with lesser sensitivity and higher variability than QSM. These results are the basis of an application for certification by the US Food and Drug Administration of QSM as a biomarker of drug effect on bleeding in cavernous malformations. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03652181.
Trial Readiness of Cavernous Malformations With Symptomatic Hemorrhage, Part I: Event Rates and Clinical Outcome
Flemming, Kelly D. , Kim, Helen , Hage, Stephanie , Mandrekar, Jay , Kinkade, Serena , Torbey, Michel , Huang, Judy , Huston, John , Shu, Yunhong , Selwyn, Reed , Hart, Blaine L. , Feghali, James , Sair, Haris I. , Narvid, Jared , Lupo, Janine , Stadnik, Agnieszka , Lane, Karen , McBee, Nichole, Treine, Kevin, Ostapkovich, Noeleen , Wang, Ying , Thompson, Richard E. , Awad, Issam A. , Huston, John , Torbey, Michel , Huang, Judy , Shu, Yunhong , Lanzino, Giuseppe , Selwyn, Reed , Hart, Blaine , Mabray, Marc C , Feghali, James , Narvid, Jared , Alcazar-Felix, Roberto J , Shenkar, Robert , Lane, Karen , Ostapkovich, Noeleen , Koenig, James I , Carroll, Timothy , Hanley, Daniel F , Awad, Issam , Flemming, Kelly D , Kim, Helen , Girard, Romuald , Lanzino, Giuseppe , Mabray, Marc C. , Lee, Justine C. , Alcazar‐Félix, Roberto J. , Shenkar, Robert , Koenig, James I. , Hanley, Daniel F.

Mayo Clinic

Stroke | December 22, 2023 | Volume: 55 | Issue: 1 | Pages: 22-30

10.1161/strokeaha.123.044068 | PMID 38134268 Get It

BACKGROUND: Cerebral cavernous malformation with symptomatic hemorrhage (SH) are targets for novel therapies. A multisite trial-readiness project ( https://www.clinicaltrials.gov ; Unique identifier: NCT03652181) aimed to identify clinical, imaging, and functional changes in these patients. METHODS: We enrolled adult cerebral cavernous malformation patients from 5 high-volume centers with SH within the prior year and no planned surgery. In addition to clinical and imaging review, we assessed baseline, 1- and 2-year National Institutes of Health Stroke Scale, modified Rankin Scale, European Quality of Life 5D-3 L, and patient-reported outcome-measurement information system, Version 2.0. SH and asymptomatic change rates were adjudicated. Changes in functional scores were assessed as a marker for hemorrhage. RESULTS: One hundred twenty-three, 102, and 69 patients completed baseline, 1- and 2-year clinical assessments, respectively. There were 21 SH during 178.3 patient years of follow-up (11.8% per patient year). At baseline, 62.6% and 95.1% of patients had a modified Rankin Scale score of 1 and National Institutes of Health Stroke Scale score of 0 to 4, respectively, which improved to 75.4% ( P =0.03) and 100% ( P =0.06) at 2 years. At baseline, 74.8% had at least one abnormal patient-reported outcome-measurement information system, Version 2.0 domain compared with 61.2% at 2 years ( P =0.004). The most common abnormal European Quality of Life 5D-3 L domains were pain (48.7%), anxiety (41.5%), and participation in usual activities (41.4%). Patients with prospective SH were more likely than those without SH to display functional decline in sleep, fatigue, and social function patient-reported outcome-measurement information system, Version 2.0 domains at 2 years. Other score changes did not differ significantly between groups at 2 years. The sensitivity of scores as an SH marker remained poor at the time interval assessed. CONCLUSIONS: We report SH rate, functional, and patient-reported outcomes in trial-eligible cerebral cavernous malformation with SH patients. Functional outcomes and patient-reported outcomes generally improved over 2 years. No score change was highly sensitive or specific for SH and could not be used as a primary end point in a trial.
NRG‐GY012: Randomized phase 2 study comparing olaparib, cediranib, and the combination of cediranib/olaparib in women with recurrent, persistent, or metastatic endometrial cancer
Rimel, B.J. , Enserro, Danielle , Bender, David , Jackson, Camille Gunderson, Tan, Annie , Alluri, Nitya , Borowsky, Mark E., Moroney, John W. , Hendrickson, Andrea Wahner, Backes, Floor , Swisher, Elizabeth M. , Powell, Matthew A. , Mackay, Helen , Rimel, Bobbie J , Swisher, Elizabeth M , Backes, Floor

Mayo Clinic

Cancer | December 21, 2023 | Volume: 130 | Issue: 8 | Pages: 1234-1245

10.1002/cncr.35151 | PMID 38127487 Get It

AbstractPurposeThis paper reports the efficacy of the poly (ADP‐ribose) polymerase inhibitor olaparib alone and in combination with the antiangiogenesis agent cediranib compared with cediranib alone in patients with advanced endometrial cancer.MethodsThis was open‐label, randomized, phase 2 trial (NCT03660826). Eligible patients had recurrent endometrial cancer, received at least one (<3) prior lines of chemotherapy, and were Eastern Cooperative Oncology Group performance status 0 to 2. Patients were randomly assigned (1:1:1), stratified by histology (serous vs. other) to receive cediranib alone (reference arm), olaparib, or olaparib and cediranib for 28‐day cycles until progression or unacceptable toxicity. The primary end point was progression‐free survival in the intention‐to‐treat population. Homologous repair deficiency was explored using the BROCA‐GO sequencing panel.ResultsA total of 120 patients were enrolled and all were included in the intention‐to‐treat analysis. Median age was 66 (range, 41–86) years and 47 (39.2%) had serous histology. Median progression‐free survival for cediranib was 3.8 months compared with 2.0 months for olaparib (hazard ratio, 1.45 [95% CI, 0.91‐2.3] p = .935) and 5.5 months for olaparib/cediranib (hazard ratio, 0.7 [95% CI, 0.43–1.14] p = .064). Four patients receiving the combination had a durable response lasting more than 20 months. The most common grade 3/4 toxicities were hypertension in the cediranib (36%) and olaparib/cediranib (33%) arms, fatigue (20.5% olaparib/cediranib), and diarrhea (17.9% cediranib). The BROCA‐GO panel results were not associated with response.ConclusionThe combination of cediranib and olaparib demonstrated modest clinical efficacy; however, the primary end point of the study was not met. The combination was safe without unexpected toxicity.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Mayo Clinic

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 | PMID 38115695 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
Cold platelet transfusion: The effects of a fluid warmer on platelet function
Morales, Diana J. Valencia , Klompas, Allan M. , Torbenson, Jenna M., Finney, Robyn E. , Stubbs, James R. , Nuttall, Gregory A. , Valencia Morales, Diana J , Stubbs, James R , Nuttall, Gregory A , Chen, Dong

Mayo Clinic

Transfusion | December 20, 2023 | Volume: 64 | Issue: 1 | Pages: 47-52

10.1111/trf.17624 | PMID 38115202 Get It

AbstractBackgroundRecently the US Food and Drug Administration has granted variances to select blood centers to supply cold‐stored platelet components (CSP). In hemorrhage resuscitation warming of blood components with approved fluid warming devices is common.Study Design and MethodsPathogen‐reduced apheresis platelet units were collected and stored in one of two ways: (1) CSP‐I, (2) CSP‐D. CSP‐I were collected and immediately stored at 1–6°C until used. CSP‐D were collected and stored at 20–24°C for 5 days and transferred to storage at 1–6°C until use. Aggregometry using arachidonic acid (AA), adenosine diphosphate (ADP) and collagen as agonists was performed on the unit samples before and after the units were infused through a Ranger blood‐warming device.ResultsCSP‐I, 23 units, had very high aggregation responses to all agonists (all ≥47.6 ± 20.7). There was a statistically significant reduction in ADP‐induced aggregometry results from 55.1 ± 23.2 before compared to 33.5 ± 14.6 following infusion of the PLT through the blood warmer (p < .001). There were no differences in AA and collagen aggregometry results before and after the infusion of the platelets through the blood warmer. CSP‐D had 5 of the 15 units with visible clotting in the bag. The 10 CSP‐Ds studied had lower aggregation than all agonists before and after infusion through the blood‐warming device (all ≤49.9 ± 35.9).ConclusionWe detected a statistically significant reduction in ADP‐induced aggregometry in CSP‐I run through a Ranger blood‐warming device with no change with AA or collagen agonist aggregometry.
Single‐use versus reusable rhinolaryngoscopes for inpatient otorhinolaryngology consults: Resident and patient experience
Bowen, Andrew J. , Macielak, Robert J. , Fussell, Wanda L., Yeakel, Sarah, McMillan, Ryan A. , Goates, Andrew J. , Awadallah, Andrew S. , Ekbom, Dale C. , Bowen, Andrew Jay , Macielak, Robert James , Fussell, Wanda, McMillan, Ryan, Goates, Andrew, Awadallah, Andrew

Mayo Clinic

Laryngoscope Investigative Otolaryngology | December 19, 2023 | Volume: 9 | Issue: 1 | Pages: No page available

10.1002/lio2.1203 | PMID 38362188 Get It

AbstractObjectivesSingle‐use rhinolaryngoscopes were brought to market in 2019 as an alternative to traditional reusable scopes and have garnered interest across settings given portability and potential cost advantages. While single‐use was previously evaluated compared to traditional devices, the overall impact to the consult experience for both users and patients has not been captured.MethodsEighteen residents performed consults with both single‐use and reusable rhinolaryngoscope systems on alternating weeks. A five‐question cumulative survey administered across three assessment points over a 12‐week period using a five‐point rating system to rate favorability. Residents and patients also completed four‐point scale surveys following procedure(s) to capture the consult experience. Statistical analyses were performed to measure significance differences between survey responses between the two systems.ResultsSingle‐use rhinolaryngoscopes received higher overall ratings compared with reusables across each metric captured including overall consult time (4.3 vs. 2.2, p < .001), multiscope consults (4.4 vs. 3.1, p < .001), patient communication (4.6 vs. 2.1, p < .001), teaching opportunities (4.6 vs. 2.1, p < .001), and overall ease of use (4.7 vs. 2.6, p < .001). Residents rated single‐use higher than reusable after each procedure in terms of ease of use (1.07 vs. 2.68, p < .001) and visual clarity (1.27 vs. 1.89, p = .003), while patients rated single‐use higher for understanding of illness (3.9 vs. 3.1, p < .001) and understanding of treatment rationale (3.9 vs. 3.1, p < .001).ConclusionResident and patient experience feedback favored single‐use rhinolaryngoscopes compared to reusable scope technology across multiple surveyed measurables. Single‐use rhinolaryngoscopes provide a viable tool for otorhinolaryngologist and other clinicians to perform rhinolaryngoscopy consults.Level of Evidence4.
Abstract 18300: Do Current Cardiovascular Risk Models Predict the Development of Cardiotoxicity in Lymphoma Patients Treated With Anthracycline?
Ricaurte, Carolina, Daryanani, Andres , Collantes, Diana, Toro-Manotas, Rafael , Barros, Lara Nhola, Herrmann, Joerg , Thompson, Carrie A. , Villarraga, Hector R. , Santos-Patarroyo, Sebastián , Cerhan, James R.

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18300 Get It

Introduction: Assessing baseline cardiovascular (CV) risk factors is crucial for identifying cancer patients at higher risk of cardiotoxicity (CT). While both CT specific scores, including Heart Failure Association-International Cardio Oncology Society (HFA-ICOS) and our institutional score, as well as general CV scores like Atherosclerotic cardiovascular disease (ASCVD), have been used to assess CT risk; in lymphoma patients undergoing anthracycline therapy, their utility remains unknown. Aim: Evaluate the performance of each risk score to predict CT in a cohort of newly diagnosed lymphoma patients undergoing anthracycline treatment, followed for a median of 5.4 years. Methods: 326 Hodgkin and non-Hodgkin lymphoma patients treated and followed from 2013 to 2021 were prospectively assessed. Baseline measurements of the three risk scores were obtained. ASCVD score was not assessed in patients >80 or <40 years old or without baseline cholesterol. CT was defined during or after one year of chemotherapy as severe, moderate, or mild according to 2022 ESC guidelines. Logistic regression and AUC were used to assess the association of each score and compare the models. Results: Among 326 patients, 78 developed CT (8 severe, 21 moderate, 49 mild). A high-risk score from HFA-ICOS was significantly associated with severe and moderate CT(OR: 6.1, p=0.001), sensitivity 37%, and specificity 88%. A very high-risk classification of the institutional score was associated with severe and moderate CT (OR: 8.4, p=0.006), sensitivity 44%, and specificity 81%. No association was found between the ASCVD score stratification and CT. When mild CT was included in the analysis, the AUC values were lower (see Table 1). Conclusions: Cardio-oncology risk scores were associated with severe and moderate CT, outperforming ASCVD, but their predictive capacity was weak. Incorporating other serum or imaging biomarkers into the models may improve the predictive accuracy of CT risk assessment.
Abstract 17189: Association Between an Artificial Intelligence-Enabled ECG Algorithm for Detection of Atrial Fibrillation While in Sinus Rhythm, and Hospitalization for Recurrent Ischemic Stroke in the Community
Sheffeh, Mohammad Ali , Brown, Robert D. , Klaas, James P. , Koriesh, Ahmed, Medina-Inojosa, Betsy, Mangold, Kathryn, Estrada-Magana, Andres , Friedman, Paul A. , Medina‐Inojosa, José R. , Medina‐Inojosa, Betsy J. , Rabinstein, Alejandro A. , Noseworthy, Peter A. , Attia, Zachi I. , López-Jiménez, Francisco

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17189 Get It

Introduction: Artificial Intelligence-enabled electrocardiogram (AI-ECG) can estimate the probability of having atrial fibrillation (AFib) while in sinus rhythm. Recurrent stroke in subjects without known AFib may be due to undiagnosed AFib. We evaluated the association between AI-ECG AFib and recurrent ischemic stroke and with incident AFib Methods: Consecutive adults admitted to a Mayo Clinic or Mayo Clinic Health System hospital or to Olmsted Community Hospital for ischemic stroke between January,1,2000 and June,30,2022 were identified using the Rochester Epidemiology Project. Recurrent ischemic strokes were identified after reviewing medical records and imaging studies. We excluded those with known AFib or without ECGs within 3 years prior to the first ischemic stroke. The AI-ECG network was previously developed using 649,931 ECGs from > 180,000 subjects. The primary endpoint was recurrent ischemic stroke; secondary endpoint was incident AFib. Cox model adjusted for age, sex, and CHA2DS2-VASc2 score variables. Results: We included 4,816 subjects, mean age 70±15 yr, 54% male, 92% white, median CHA2DS2-VASc2 score 4 [3-5], median follow-up 3 [1-7] yr. 280 subjects (6%) had a second stroke and 366 (8%) were diagnosed with incident AFib over follow-up. Those with a positive AI-ECG AFib had an increased risk for recurrent ischemic stroke(HR 1.54, 95% CI 1.21-1.96, P<0.001 Figure A) This association remained significant after adjustment for CHA2DS2-VASc2 score(HR 1.37 95% CI 1.07-1.76, P=0.01). These associations were not affected by anticoagulation use over follow-up. AI-ECG AFib was also associated with incident AFib(HR 2.42 95% CI 1.96-2.98, P<0.001 Figure B) Conclusions: AI-ECG AFib predicts recurrent ischemic stroke in the community, possibly reflecting undiagnosed AFib that can be detected by AI-ECG, as it also predicts incident AFib. These results underscore the potential utility of AI-ECG for risk stratification of patients with ischemic stroke.
Abstract 16570: Benchmarking Risk-Adjusted Outcomes in Congenital Heart Surgery
Subramanyan, Ram Kumar, Thibault, Dylan, O’Brien, Sean M. , Shahian, David M. , Bacha, Emile , Badhwar, Vinay , Caldarone, C.A., Fernández, Félix G. , Pasquali, Sara K. , Rainey, Tabitha, Romano, Jennifer C., Shashidharan, Subhadra, Tweddell, James S., Mayer, John E. , Gaynor, J. William , Dearani, Joseph A. , Jacobs, Jeffrey P. , Overman, David M.

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16570 Get It

Background: Robust models exist to predict risk-adjusted mortality following congenital heart surgery. It is known that underlying diagnosis modifies predicted risk of operations, and institution-level outcomes vary based on their unique case mix. We therefore evaluated risk-adjusted outcomes for a subset of diagnosis-procedure (D-P) combinations within the Society of Thoracic Surgeons' (STS) congenital heart surgery database (CHSD). Methods: A clinician panel identified the most frequently encountered D-P combinations in CHSD between 07/2017 and 06/2021. Candidate modeling techniques were compared in a random 80% development cohort. Model performance was assessed using internal and cross-validation calibration, discrimination plots and optimism adjusted C-statistics. The final selected model was evaluated in the 20% validation sample. Results: The chosen subset of D-P combinations represented 45,384 of 87,589 (52%) unique episodes of surgical care in CHSD during this time-period. The development cohort (36,350 episodes) had 1.8% mortality (667 deaths). All candidate models had excellent discrimination with C-statistics ranging from 0.862 to 0.876. The model with the best combination of discrimination, calibration, and clinical face validity was a modified version of the current STS mortality risk model. This version included all current risk model variables with the addition of indicator variables for D-P combinations. In the 20% validation sample (9,034 episodes), this model was well calibrated (Figure) and had excellent discrimination (C = 0.879). Conclusion: We describe a cohort of D-P combinations widely encountered in the STS CHSD. Further, we refined the existing STS CHSD risk model for application to these D-P dyads to derive empirical risk-adjusted benchmark outcomes. This approach will benefit quality improvement efforts at an institutional level and may have implications for publicly reporting congenital heart surgery outcomes.