Citations

Clear

3316 citation(s) found for "Alexander, J".

Automated identification of glomeruli and synchronised review of special stains in renal biopsies by machine learning and slide registration: a cross‐institutional study
Wilbur, David C. , Cornell, Lynn D. , Andryushkin, Alexander, Pettus, Jason R. , Cornell, Lynn , Smith, Maxwell L.

Mayo Clinic

Histopathology | April 4, 2021 | Volume: 79 | Issue: 4 | Pages: 499-508

10.1111/his.14376 | PMID 33813779 Get It

AimsMachine learning in digital pathology can improve efficiency and accuracy via prescreening with automated feature identification. Studies using uniform histological material have shown promise. Generalised application requires validation on slides from multiple institutions. We used machine learning to identify glomeruli on renal biopsies and compared performance between single and multiple institutions.Methods and resultsRandomly selected, adequately sampled renal core biopsy cases (71) consisting of four stains each (haematoxylin and eosin, trichrome, silver, periodic acid Schiff) from three institutions were digitised at ×40. Glomeruli were manually annotated by three renal pathologists using a digital tool. Cases were divided into training/validation (n = 52) and evaluation (n = 19) cohorts. An algorithm was trained to develop three convolutional neural network (CNN) models which tested case cohorts intra‐ and inter‐institutionally. Raw CNN search data from each of the four slides per case were merged into composite regions of interest containing putative glomeruli. The sensitivity and modified specificity of glomerulus detection (versus annotated truth) were calculated for each model/cohort. Intra‐institutional (3) sensitivity ranged from 90 to 93%, with modified specificity from 86 to 98%. Interinstitutional (1) sensitivity was 77%, with modified specificity 97%. Combined intra‐ and inter‐institutional (1) sensitivity was 86%, with modified specificity 92%.ConclusionsFeature detection sensitivity degrades when training and test material originate from different sites. Training using a combined set of digital slides from three institutions improves performance. Differing histology methods probably account for algorithm performance contrasts. Our data highlight the need for diverse training sets for the development of generalisable machine learning histology algorithms.
Association of Virtual Surgical Planning With External Incisions in Complex Maxillectomy Reconstruction
Moore, Eric J. , Price, Daniel L., Abel, Kathryn M. Van , Janus, J.R., Moore, Ethan , Martin, Eli, Morris, Johnathan M., Alexander, Amy E. , Janus, Jeffery R, Moore, Ethan T, Van Abel, Kathryn M , Price, Daniel L. , Martin, Eliot J., Morris, Johnathan M.

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | April 1, 2021 | Volume: 147 | Issue: 6 | Pages: 526

10.1001/jamaoto.2021.0251 | PMID 33792635 Get It

Effects of sheared chromatin length on ChIP-seq quality and sensitivity
Keller, Cheryl A. , Wixom, Alexander Q. , Heuston, Elisabeth F. , Giardine, Belinda , Hsiung, Chris C.‐S. , Long, Maria, Miller, Amber, Anderson, Stacie M. , Cockburn, April, Blobel, Gerd A. , Bodine, David M. , Hardison, Ross C. , Wixom, Alexander Q

Mayo Clinic

G3 Genes|Genomes|Genetics | March 31, 2021 | Volume: 11 | Issue: 6 | Pages: No page available

10.1093/g3journal/jkab101 | PMID 33788948 Get It

Abstract Chromatin immunoprecipitation followed by massively parallel, high throughput sequencing (ChIP-seq) is the method of choice for genome-wide identification of DNA segments bound by specific transcription factors or in chromatin with particular histone modifications. However, the quality of ChIP-seq datasets varies widely, with a substantial fraction being of intermediate to poor quality. Thus, it is important to discern and control the factors that contribute to variation in ChIP-seq. In this study, we focused on sonication, a user-controlled variable, to produce sheared chromatin. We systematically varied the amount of shearing of fixed chromatin from a mouse erythroid cell line, carefully measuring the distribution of resultant fragment lengths prior to ChIP-seq. This systematic study was complemented with a retrospective analysis of additional experiments. We found that the level of sonication had a pronounced impact on the quality of ChIP-seq signals. Over-sonication consistently reduced quality, while the impact of under-sonication differed among transcription factors, with no impact on sites bound by CTCF but frequently leading to the loss of sites occupied by TAL1 or bound by POL2. The bound sites not observed in low-quality datasets were inferred to be a mix of both direct and indirect binding. We leveraged these findings to produce a set of CTCF ChIP-seq datasets in rare, primary hematopoietic progenitor cells. Our observation that the amount of chromatin sonication is a key variable in success of ChIP-seq experiments indicates that monitoring the level of sonication can improve ChIP-seq quality and reproducibility and facilitate ChIP-seq in rare cell types.
Extracorporeal Life Support Organization (ELSO): Guidelines for Pediatric Cardiac Failure
Brown, Georgia , Moynihan, Katie M. , Deatrick, Kristopher B., Sandhu, Hitesh , Aganga, Devon O. , Menon, Anuradha P. , Rozen, Thomas, Raman, Lakshmi , Alexander, Peta , Peek, Giles J. , Sandhu, Hitesh S , Aganga, Devon , Hoskote, Aparna U. , Deshpande, Shriprasad R.

Mayo Clinic

ASAIO Journal | March 31, 2021 | Volume: 67 | Issue: 5 | Pages: 463-475

10.1097/mat.0000000000001431 | PMID 33788796 Get It

These guidelines are applicable to neonates and children with cardiac failure as indication for extracorporeal life support. These guidelines address patient selection, management during extracorporeal membrane oxygenation, and pathways for weaning support or bridging to other therapies. Equally important issues, such as personnel, training, credentialing, resources, follow-up, reporting, and quality assurance, are addressed in other Extracorporeal Life Support Organization documents or are center-specific.
Short and long‐term outcomes of three‐dimensional printed surgical guides and virtual surgical planning versus conventional methods for fibula free flap reconstruction of the mandible: Decreased nonunion a
May, Matthew M. , Howe, Benjamin M., O’Byrne, Thomas J., Alexander, Amy E. , Morris, Jonathon M., Moore, Eric J. , Kasperbauer, Jan L. , Janus, Jeffrey R. , Abel, Kathryn M. Van , Dickens, Hunter J., Van Abel, Kathryn M , Howe, Benjamin M. , Price, Daniel L.

Mayo Clinic

Head & Neck | March 31, 2021 | Volume: 43 | Issue: 8 | Pages: 2342-2352

10.1002/hed.26688 | PMID 33786910 Get It

Abstract Background To determine whether virtual surgical planning and three‐dimensional printed cutting guides (3D/VSP) improved radiographic bone union compared to conventional methods (CM) in fibula free flap (FFF) reconstruction of the mandibles. Methods Retrospective study from the years 2000–2018 at a tertiary hospital. Osseous union was evaluated by a radiologist blinded to each patient's treatment. Results Two hundred sixty patients who underwent FFF tissue transfer, 28 with VSP and 3D cutting guides. Bony union was not achieved in 46 (20%) patients who underwent CM compared to 1 (4%) of patients with VSP and guides ( p = 0.036). FFF complication was significantly higher in CM with 87 patients (38%) compared to three patients (11%) in 3D/VSP ( p = 0.005). Median time to bony union for patients who underwent CM was 1.4 years compared to 0.8 years in 3D/VSP. Conclusions 3D/VSP reduced the rate of radiographic nonunion and flap‐related complications in FFF reconstruction for mandibular defects.
Mutations in BRCA1/2 and Other Panel Genes in Patients With Metastatic Breast Cancer —Association With Patient and Disease Characteristics and Effect on Prognosis
Fasching, Peter A. , Yadav, Siddhartha , Wunderle, Marius , Häberle, Lothar , Hart, Steven N. , Rübner, Matthias, Polley, Eric C. , Lee, Kun Y. , Hadji, Peyman , Hübner, H., Tesch, Hans , Ettl, Johannes , Overkamp, Friedrich , Ekici, Arif B. , Volz, Bernhard , Uhrig, Sabrina , Lüftner, Diana , Müller, Volkmar , Belleville, Erik, Kolberg, Hans‐Christian , Beckmann, Matthias W. , Hartmann, Arndt , Janni, Wolfgang , Taran, Florin‐Andrei , Fehm, Tanja , Wallwiener, D. , Schneeweiß, Andreas , Chen, Chen , Hu, Chunling , Wunderle, Marius , Hart, Steven N , Polley, Eric C , Lee, Kun Y , Gnanaolivu, Rohan D., Hübner, Hanna , Lux, Michael P , Ekici, Arif B , Müller, Volkmar , Untch, Michael , Kolberg, Hans-Christian , Reis, André , Schneeweiss, Andreas , Hartkopf, Andreas D , Couch, Fergus J. , Chen, C , Yadav, Siddhartha , Fehm, Tanja , Hu, Chunling , Gnanaolivu, Rohan , Lux, Michael P. , Wallwiener, Markus , Untch, Michael , Reis, André , Wimberger, Pauline , Brucker, Sara Yvonne , Couch, Fergus J.

Mayo Clinic

Journal of Clinical Oncology | March 29, 2021 | Volume: 39 | Issue: 15 | Pages: 1619-1630

10.1200/jco.20.01200 | PMID 33780288 Get It

PURPOSE Among patients with metastatic breast cancer (mBC), the frequency of germline mutations in cancer susceptibility genes and the clinical relevance of these mutations are unclear. In this study, a prospective cohort of patients with mBC was used to determine mutation rates for breast cancer (BC) predisposition genes, to evaluate the clinical characteristics of patients with mutations, and to assess the influence of mutations on patient outcome. PATIENTS AND METHODS Germline DNA from 2,595 patients with mBC enrolled in the prospective PRAEGNANT registry was evaluated for mutations in cancer predisposition genes. The frequencies of mutations in known BC predisposition genes were compared with results from a prospective registry of patients with nonmetastatic BC sequenced using the same QIAseq method and with public reference controls. Associations between mutation status and tumor characteristics, progression-free survival, and overall survival were assessed. RESULTS Germline mutations in 12 established BC predisposition genes (including BRCA1 and BRCA2) were detected in 271 (10.4%) patients. A mutation in BRCA1 or BRCA2 was seen in 129 patients (5.0%). BRCA1 mutation carriers had a higher proportion of brain metastasis (27.1%) compared with nonmutation carriers (12.8%). Mutations were significantly enriched in PRAEGNANT patients with mBC compared with patients with nonmetastatic BC (10.4% v 6.6%, P < .01). Mutations did not significantly modify progression-free survival or overall survival for patients with mBC. CONCLUSION Multigene panel testing may be considered in all patients with mBC because of the high frequency of germline mutations in BRCA1/2 and other BC predisposition genes. Although the prognosis of mutation carriers and nonmutation carriers with mBC was similar, differences observed in tumor characteristics have implications for treatment and for future studies of targeted therapies.
Comparison of the investigational device exemption and post‐approval trials of the Melody transcatheter pulmonary valve
Kreutzer, Jacqueline , Armstrong, Aimee K. , Rome, Jonathan J. , Zellers, Thomas M. , Balzer, David T. , Zampi, Jeffrey D. , Javois, Alexander J., Turner, Daniel R. , Gray, Robert G. , Moore, John W. , Weng, Shicheng, Jones, Thomas K. , Khan, Danyal , Vincent, Julie A., Hellenbrand, William E. , Bergersen, Lisa , McElhinney, Doff B. , Cabalka, Allison K. , Gray, Robert G , Moore, John W , Jones, Thomas K , McElhinney, Doff B , Cheatham, John P.

Mayo Clinic

Catheterization and Cardiovascular Interventions | March 29, 2021 | Volume: 98 | Issue: 2 | Pages: No page available

10.1002/ccd.29657 | PMID 33780150 Get It

AbstractObjectiveWe compared 5‐year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post‐approval study (PAS) and the investigational device exemption (IDE) trial.BackgroundAs a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a “real‐world” environment. The 5‐year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared.MethodsThe cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time‐related outcomes and valve‐related adverse events were compared between the two trials with Kaplan–Meier curves and log‐rank testing.Results167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both.ConclusionsHemodynamic and time‐related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real‐world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post‐approval studies as part of the regulatory process for Class III medical devices.
Surgical management of a giant congenital left ventricular aneurysm in a 2-month-old infant.
Egunov, O.A. , Krivoshchekov, Evgeniy, Cetta, Frank , Sviazov, Evgenii A. , Sokolov, Alexander, Egunov, Oleg A , Krivoshchekov, Evgeny V , Sokolov, Alexander

Mayo Clinic

No container title available | March 28, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.161693988.82901421/v1 Get It

This clinical case demonstrated surgical management of a giant congenital left ventricular aneurysm in a 2-month-old female using the Dor procedure. Transthoracic echocardiography performed at 6-month follow-up showed an ejection fraction of 66%.
The American Society of Colon and Rectal Surgeons Clinical Practice Guidelines for the Management of Clostridioides difficile Infection
Boutros, Marylise , Khanna, Sahil , Paquette, Ian M., Poylin, Vitaliy Y. , Hawkins, Alexander T. , Bhama, Anuradha R. , Lightner, Amy L. , Feingold, Daniel L.

Mayo Clinic

Diseases of the Colon & Rectum | March 26, 2021 | Volume: 64 | Issue: 6 | Pages: 650-668

10.1097/dcr.0000000000002047 | PMID 33769319 Get It

Hemodynamic Basis for Dyspnea in Pulmonary Vein Stenosis
Jain, C. Charles , Holmes, David R. , Egbe, Alexander C. , Miranda, William R.

Mayo Clinic

Circulation: Heart Failure | March 25, 2021 | Volume: 14 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.120.007820 | PMID 33761753 Get It