Citations

Clear

38 citation(s) found for "Thomas, Alexander".

Acute Leukemia Classification Using Transcriptional Profiles From Low-Cost Nanopore mRNA Sequencing
Wang, Jeremy , Bhakta, Nickhill , Miller, Vanessa Ayer , Revsine, Mahler, Litzow, Mark R. , Paietta, Elisabeth, Fedoriw, Yuri, Roberts, Kathryn G., Gu, Zhaohui , Mullighan, Charles G. , Jones, Corbin D. , Ayer Miller, Vanessa , Alexander, Thomas B , Mullighan, Charles G , Wang, Jeremy R , Bhakta, Nickhill , Revsine, Mahler, Litzow, Mark R. , Paietta, Elisabeth, Fedoriw, Yuri, Roberts, Kathryn G., Gu, Zhaohui , Jones, Corbin D.

Mayo Clinic

JCO Precision Oncology | April 20, 2022 | Volume: No volume available | Issue: 6 | Pages: No page available

10.1200/po.21.00326 | PMID 35442720 Get It

PURPOSE Most cases of pediatric acute leukemia occur in low- and middle-income countries, where health centers lack the tools required for accurate diagnosis and disease classification. Recent research shows the robustness of using unbiased short-read RNA sequencing to classify genomic subtypes of acute leukemia. Compared with short-read sequencing, nanopore sequencing has low capital and consumable costs, making it suitable for use in locations with limited health infrastructure. MATERIALS AND METHODS We show the feasibility of nanopore mRNA sequencing on 134 cryopreserved acute leukemia specimens (26 acute myeloid leukemia [AML], 73 B-lineage acute lymphoblastic leukemia [B-ALL], 34 T-lineage acute lymphoblastic leukemia, and one acute undifferentiated leukemia). Using multiple library preparation approaches, we generated long-read transcripts for each sample. We developed a novel composite classification approach to predict acute leukemia lineage and major B-ALL and AML molecular subtypes directly from gene expression profiles. RESULTS We demonstrate accurate classification of acute leukemia samples into AML, B-ALL, or T-lineage acute lymphoblastic leukemia (96.2% of cases are classifiable with a probability of > 0.8, with 100% accuracy) and further classification into clinically actionable genomic subtypes using shallow RNA nanopore sequencing, with 96.2% accuracy for major AML subtypes and 94.1% accuracy for major B-lineage acute lymphoblastic leukemia subtypes. CONCLUSION Transcriptional profiling of acute leukemia samples using nanopore technology for diagnostic classification is feasible and accurate, which has the potential to improve the accuracy of cancer diagnosis in low-resource settings.
The year in cardiovascular medicine 2021: cardio-oncology
Herrmann, Joerg , López‐Fernández, Teresa , Lyon, Alexander R. , López-Fernández, Teresa , Lyon, Alexander R

Mayo Clinic

European Heart Journal | December 21, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/eurheartj/ehab891 | PMID 34974609 Get It

Cervical Alignment and Proximal and Distal Junctional Failure in Posterior Cervical Fusion
Monsef, Jad Bou , Mao, Jennifer Z. , Xiong, Ashley , Bowles, Daniel R. , Conaway, William K. , Reiter, David M, Honig, Rachel , Currier, Bradford L. , Freedman, Brett A. , Bydon, Mohamad , Elder, Benjamin D. , Kaye, I. David , Kepler, Christopher K. , Schroeder, Gregory D. , Wagner, Scott C. , Sebastian, Arjun S. , Bou Monsef, Jad, Pinter, Zachariah W. , Karamian, Brian A. , Reiter, David M, Nassr, Ahmad , Vaccaro, Alexander R.

Mayo Clinic

Clinical Spine Surgery | December 15, 2021 | Volume: 35 | Issue: 5 | Pages: E451-E456

10.1097/bsd.0000000000001281 | PMID 34907934 Get It

Study Design: This was a multicenter retrospective cohort study. Objective: The purpose of this study was to compare the surgical and radiographic outcomes of patients undergoing posterior cervical fusion (PCF) with constructs extending from C2 to T2 to patients with constructs extending from C3 to T1. Summary of Background Data: Limited evidence exists regarding the appropriate level of proximal and distal extension of PCF constructs. Methods: A multicenter retrospective cohort study of patients who underwent PCF between 2012 and 2020 was performed. Surgical and radiographic outcomes were compared between those who had C3–T1 or C2–T2 constructs. Results: A total of 155 patients were included in the study (C2–T2: 106 patients, C3–T1: 49 patients). There were no significant differences in demographics or preoperative symptoms between cohorts. Fusion rates were significantly higher in the C2–T2 (93%) than the C3–T1 (80%, P=0.040) cohort. When comparing the C2–T2 to the C3–T1 cohort, the C3–T1 cohort had a significantly greater rate of proximal junctional failure (2% vs. 10%, P=0.006), distal junctional failure (1% vs. 20%, P<0.001) and distal screw loosening (4% vs. 15%, P=0.02). Although ∆C2–C7 sagittal vertical axis increased significantly in both cohorts (C2–T2: 6.2 mm, P=0.04; C3–T1: 8.4 mm, P<0.001), correction did not significantly differ between groups (P=0.32). The C3–T1 cohort had a significantly greater increase in ∆C2 slope (8.0 vs. 3.1 degrees, P=0.03) and ∆C0–C2 Cobb angle (6.4 vs. 1.2 degrees, P=0.04). Conclusion: In patients undergoing PCF, a C2–T2 construct demonstrated lower rates of pseudarthrosis, distal junctional failure, proximal junctional failure, and compensatory upper cervical hyperextension compared with a C3–T1 construct.
No Difference in Neck Pain or Health-Related Quality Measures Between Patients With or Without Degenerative Cervical Spondylolisthesis
Kaye, I. David , Sebastian, Arjun S. , Wagner, Scott C. , Semenza, Nicholas C. , Bowles, Daniel R. , Schroeder, Gregory D. , Kepler, Chris K., Woods, Barret I., Rihn, Jeff, Anderson, David Greg, Hilibrand, Alan S. , Kepler, Christopher K. , Kaye, Ian David , Semenza, Nicholas , Radcliff, Kris E. , Kurd, Mark F. , Vaccaro, Alexander R.

Mayo Clinic

Global Spine Journal | September 27, 2021 | Volume: 13 | Issue: 6 | Pages: 1641-1645

10.1177/21925682211046906 | PMID 34570993 Get It

Study Design This study is a retrospective case control. Objectives This study aims to determine whether cervical degenerative spondylolisthesis (DS) is associated with increased baseline neck/arm pain and inferior health quality states compared to a similar population without DS. Methods Patient demographics, pre-operative radiographs, and baseline PROMs were reviewed for 315 patients undergoing anterior cervical decompression and fusion (ACDF) with at least 1 year of follow-up. Patients were categorized based on the presence (S) or absence of a spondylolisthesis (NS). Statistically significant variables were further explored using multiple linear regression analysis. Results 49/242 (20%) patients were diagnosed with DS, most commonly at the C4–5 level (27/49). The S group was significantly older than the NS group (58.0 ± 10.7 vs 51.9 ± 9.81, P = .001), but otherwise, no demographic differences were identified. Although a higher degree of C2 slope was found among the S cohort (22.5 ± 8.63 vs 19.8 ± 7.78, P = .044), no differences were identified in terms of preoperative visual analogue scale (VAS) neck pain or NDI. In the univariate analysis, the NS group had significantly increased VAS arm pain relative to the S group (4.93 ± 3.16 vs 3.86 ± 3.30, P = .045), which was no longer significant in the multivariate analysis. Conclusions Although previous reports have suggested an association between cervical DS and neck pain, we could not associate the presence of DS with increased baseline neck or arm pain. Instead, DS appears to be a relatively frequent (20% in this series) age-related condition reflecting radiographic, rather than necessarily clinical, disease.
Defining cardiovascular toxicities of cancer therapies: an International Cardio-Oncology Society (IC-OS) consensus statement
Herrmann, Joerg , Lenihan, Daniel J. , Armenian, Saro H. , Barac, Ana , Blaes, Anne , Cardinale, Daniela , Carver, Joseph R. , Dent, Susan , Ky, Bonnie , Lyon, Alexander R. , Fradley, Michael G. , Ganatra, Sarju , Curigliano, Giuseppe , Mitchell, Joshua D. , Minotti, Giorgio , Lang, Ninian N. , Liu, Jennifer E. , Neilan, Tomas G. , O’Quinn, Rupal, Pusic, Iskra , Porter, Charles , Reynolds, Kerry L. , Ruddy, Kathryn J. , Valent, Peter , Lenihan, Daniel , Armenian, Saro H , Carver, Joseph , López-Fernández, Teresa , Fradley, Michael G , Ganatra, Sarju , Curigliano, Giuseppe , Mitchell, Joshua D , Minotti, Giorgio , Lang, Ninian N , Nohria, Anju , Porter, Charles , Thavendiranathan, Paaladinesh , Barac, Ana , Blaes, Anne H , Ky, Bonnie , Valent, Peter , Lyon, Alexander R , López‐Fernández, Teresa , Dent, Susan

Mayo Clinic

European Heart Journal | September 10, 2021 | Volume: 43 | Issue: 4 | Pages: 280-299

10.1093/eurheartj/ehab674 | PMID 34904661 Get It

Abstract The discipline of Cardio-Oncology has seen tremendous growth over the past decade. It is devoted to the cardiovascular (CV) care of the cancer patient, especially to the mitigation and management of CV complications or toxicities of cancer therapies, which can have profound implications on prognosis. To that effect, many studies have assessed CV toxicities in patients undergoing various types of cancer therapies; however, direct comparisons have proven difficult due to lack of uniformity in CV toxicity endpoints. Similarly, in clinical practice, there can be substantial differences in the understanding of what constitutes CV toxicity, which can lead to significant variation in patient management and outcomes. This document addresses these issues and provides consensus definitions for the most commonly reported CV toxicities, including cardiomyopathy/heart failure and myocarditis, vascular toxicity, and hypertension, as well as arrhythmias and QTc prolongation. The current document reflects a harmonizing review of the current landscape in CV toxicities and the definitions used to define these. This consensus effort aims to provide a structure for definitions of CV toxicity in the clinic and for future research. It will be important to link the definitions outlined herein to outcomes in clinical practice and CV endpoints in clinical trials. It should facilitate communication across various disciplines to improve clinical outcomes for cancer patients with CV diseases.
Ergonomics in Spine Surgery
Wagner, Scott C. , Sebastian, Arjun S. , Kolz, Joshua M. , Vaccaro, Alexander R.

Mayo Clinic

Clinical Spine Surgery | July 29, 2021 | Volume: 35 | Issue: 8 | Pages: 333-340

10.1097/bsd.0000000000001238 | PMID 34321393 Get It

As physician burnout and wellness become increasingly recognized as vital themes for the medical community to address, the topic of chronic work-related conditions in surgeons must be further evaluated. While improving ergonomics and occupational health have been long emphasized in the executive and business worlds, particularly in relation to company morale and productivity, information within the surgical community remains relatively scarce. Chronic peripheral nerve compression syndromes, hand osteoarthritis, cervicalgia and back pain, as well as other repetitive musculoskeletal ailments affect many spinal surgeons. The use of ergonomic training programs, an operating microscope or exoscope, powered instruments for pedicle screw placement, pneumatic Kerrison punches and ultrasonic osteotomes, as well as utilizing multiple surgeons or microbreaks for larger cases comprise several methods by which spinal surgeons can potentially improve workspace health. As such, it is worthwhile exploring these areas to potentially improve operating room ergonomics and overall surgeon longevity.
Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience
Rajendran, Kishore , Petersilka, Martin, Henning, André , Shanblatt, Elisabeth R. , Marsh, Jeffrey F., Thorne, Jamison E. , Schmidt, Bernhard , Flohr, Thomas , Marsh, Jeffrey, Thorne, Jamison, Fletcher, Joel, McCollough, Cynthia, Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Physics in Medicine & Biology | July 16, 2021 | Volume: 66 | Issue: 20 | Pages: 205019

10.1088/1361-6560/ac155e | PMID 34271558 Get It

Abstract We report a comprehensive evaluation of a full field-of-view (FOV) photon-counting detector (PCD) computed tomography (CT) system using phantoms, and qualitatively assess image quality in patient examples. A whole-body PCD-CT system with 50 cm FOV, 5.76 cm z-detector coverage and two acquisition modes (standard: 144 × 0.4 mm collimation and ultra-high resolution (UHR): 120 × 0.2 mm collimation) was used in this study. Phantoms were scanned to assess image uniformity, CT number accuracy, noise power spectrum, spatial resolution, material decomposition and virtual monoenergetic imaging (VMI) performance. Four patients were scanned on the PCD-CT system with matched or lower radiation dose than their prior clinical CT scans performed using energy-integrating detector (EID) CT, and the potential clinical impact of PCD-CT was qualitatively evaluated. Phantom results showed water CT numbers within ±5 HU, and image uniformity measured between peripheral and central regions-of-interests to be within ±5 HU. For the UHR mode using a dedicated sharp kernel, the cut-off spatial frequency was 40 line-pairs cm −1 , which corresponds to a 125 μ m limiting in-plane spatial resolution. The full-width-at-half-maximum for the section sensitivity profile was 0.33 mm for the smallest slice thickness (0.2 mm) using the UHR mode. Material decomposition in a multi-energy CT phantom showed accurate material classification, with a root-mean-squared-error of 0.3 mg cc −1 for iodine concentrations (2–15 mg cc −1 ) and 14.2 mg cc −1 for hydroxyapatite concentrations (200 and 400 mg cc −1 ). The average percent error for CT numbers corresponding to the iodine concentrations in VMI (40–70 keV) was 2.75%. Patient PCD-CT images demonstrated better delineation of anatomy for chest and temporal bone exams performed with the UHR mode, which allowed the use of very sharp kernels not possible with EID-CT. VMI and virtual non-contrast images generated from a patient head CT angiography exam using the standard acquisition mode demonstrated the multi-energy capability of the PCD-CT system.
Energy‐integrating‐detector multi‐energy CT: Implementation and a phantom study
Ren, Liqiang , Allmendinger, Thomas , Halaweish, Ahmed F., Schmidt, Bernhard , Flohr, Thomas , Yu, Lifeng , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Medical Physics | May 14, 2021 | Volume: 48 | Issue: 9 | Pages: 4857-4871

10.1002/mp.14943 | PMID 33988849 Get It

PurposeMulti‐energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi‐contrast imaging. The purpose of this study was to implement triple‐beam MECT on a traditional energy‐integrating‐detector (EID) CT platform (EID‐MECT).MethodsThis was accomplished by mounting a z‐axis split‐filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual‐source EID CT scanner. With the two split x‐ray beams from Tube A and the third beam from Tube B, three beams with different x‐ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple‐beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three‐material‐decomposition tasks and 1 four‐material‐decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple‐beam configurations. For comparison, the same phantom was also scanned using three other dual‐energy CT (DECT) or MECT technologies: twin‐beam DECT (TB‐DECT), dual‐source DECT (DS‐DECT), and photon‐counting‐detector CT (PCD‐CT), all with optimal x‐ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four‐material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD‐CT only (140 kV with 25, 50, 75, and 90 keV). Image‐based material decomposition was performed to acquire material‐specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple‐beam configurations in EID‐MECT and various DECT/MECT systems.ResultsThe optimal triple‐beam configuration was task‐dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID‐MECT provided comparable or better quantification accuracy in material‐specific images for all three material decomposition tasks, compared to EID‐based DECT and PCD‐CT systems. In terms of noise level comparison, EID‐MECT‐derived material‐specific images showed lower noise levels than TB‐DECT and DS‐DECT, but slightly higher than that from PCD‐CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID‐MECT showed a comparable noise level to DS‐DECT, and a much lower noise level than TB‐DECT and PCD‐CT in all material‐specific images. For the four‐material decomposition task involving I/Gd/Bi/Water, the bismuth‐specific image derived from EID‐MECT was slightly noisier, but both iodine‐ and gadolinium‐specific images showed much lower noise levels in comparison to PCD‐CT.ConclusionsFor the first time, an EID‐based MECT system that can simultaneously acquire three x‐ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.
Transition From an Open to Closed Staffing Model in the Cardiac Intensive Care Unit Improves Clinical Outcomes
Miller, P. Elliott , Chouairi, Fouad , Thomas, Alexander , Aslam, Faisal , Canavan, Maureen , Murphy, Christa, Daggula, Krishna, Metkus, Thomas S. , Vallabhajosyula, Saraschandra , Katz, Jason N. , Brennan, Joseph , Vallabhajosyula, Saraschandra , Kunitomo, Yukiko , Carnicelli, Anthony , Desai, Nihar R. , Ahmad, Tariq , Velazquez, Eric J.

Mayo Clinic

Journal of the American Heart Association | January 8, 2021 | Volume: 10 | Issue: 3 | Pages: No page available

10.1161/jaha.120.018182 | PMID 33412899 Get It

Background Several studies have shown improved outcomes in closed compared with open medical and surgical intensive care units. However, very little is known about the ideal organizational structure in the modern cardiac intensive care unit (CICU). Methods and Results We retrospectively reviewed consecutive unique admissions (n=3996) to our tertiary care CICU from September 2013 to October 2017. The aim of our study was to assess for differences in clinical outcomes between an open compared with a closed CICU. We used multivariable logistic regression adjusting for demographics, comorbidities, and severity of illness. The primary outcome was in‐hospital mortality. We identified 2226 patients in the open unit and 1770 in the closed CICU. The unadjusted in‐hospital mortality in the open compared with closed unit was 9.6% and 8.9%, respectively ( P =0.42). After multivariable adjustment, admission to the closed unit was associated with a lower in‐hospital mortality (odds ratio [OR], 0.69; 95% CI: 0.53–0.90, P =0.007) and CICU mortality (OR, 0.70; 95% CI, 0.52–0.94, P =0.02). In subgroup analysis, admissions for cardiac arrest (OR, 0.42; 95% CI, 0.20–0.88, P =0.02) and respiratory insufficiency (OR, 0.43; 95% CI, 0.22–0.82, P =0.01) were also associated with a lower in‐hospital mortality in the closed unit. We did not find a difference in CICU length of stay or total hospital charges ( P >0.05). Conclusions We found an association between lower in‐hospital and CICU mortality after the transition to a closed CICU. These results may help guide the ongoing redesign in other tertiary care CICUs.