Citations

Clear

18 citation(s) found for "Tang, Yi‐Wei".

Identification of Coryneform Bacterial Isolates by Ribosomal DNA Sequence Analysis
Graevenitz, Alexander von, Waddington, Michael, Hopkins, Marlene K., Smith, Douglas H. , Li, Haijing , Kolbert, Christopher P., Montgomery, Stacy O., Persing, David H., Tang, Yi‐Wei

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 4 | Pages: 1676-1678

10.1128/jcm.38.4.1676-1678.2000 | PMID 10747168 Get It

ABSTRACT Identification of coryneform bacteria to the species level is important in certain circumstances for differentiating contamination and/or colonization from infection, which influences decisions regarding clinical intervention. However, methods currently used in clinical microbiology laboratories for the species identification of coryneform bacteria are often inadequate. We evaluated the MicroSeq 500 16S bacterial sequencing kit (Perkin-Elmer Biosystems, Foster City, Calif.), which is designed to sequence the first 527 bp of the 16S rRNA gene for bacterial identification, by using 52 coryneform gram-positive bacilli from clinical specimens isolated from January through June 1993 at the Mayo Clinic. Compared to conventional and supplemented phenotypic methods, MicroSeq provided concordant results for identification to the genus level for all isolates. At the species level, MicroSeq provided concordant results for 27 of 42 (64.3%) Corynebacterium isolates and 5 of 6 (83.3%) Corynebacterium -related isolates, respectively. Within the Corynebacterium genus, MicroSeq gave identical species-level identifications for the clinically significant Corynebacterium diphtheriae (4 of 4) and Corynebacterium jeikeium (8 of 8), but it identified only 50.0% (15 of 30) of other species ( P < 0.01). Four isolates from the genera Arthrobacter , Brevibacterium , and Microbacterium , which could not be identified to the species level by conventional methods, were assigned a species-level identification by MicroSeq. The total elapsed time for running a MicroSeq identification was 15.5 to 18.5 h. These data demonstrate that the MicroSeq 500 16S bacterial sequencing kit provides a potentially powerful method for the definitive identification of clinical coryneform bacterium isolates.
Comparison of Protein A Gene Sequencing with Pulsed-Field Gel Electrophoresis and Epidemiologic Data for Molecular Typing of Methicillin-Resistant Staphylococcus aureus
Waddington, Michael, Smith, Douglas H. , Manahan, Janice M., Kohner, Peggy C., Highsmith, Leanne M., Li, Haijing , Cockerill, Franklin R., Thompson, Rodney L., Montgomery, Stacy O., Persing, David H., Tang, Yi‐Wei

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 4 | Pages: 1347-1351

10.1128/jcm.38.4.1347-1351.2000 | PMID 10747105 Get It

ABSTRACT The epidemiologic relatedness of methicillin-resistant Staphylococcus aureus (MRSA) isolates is currently determined by analysis of chromosomal DNA restriction patterns by pulsed-field gel electrophoresis (PFGE). We have evaluated an alternative typing system (MicroSeq StaphTrack Kit; Perkin-Elmer Biosystems) based on the sequence analysis of the chromosomally encoded polymorphic repeat X region of the S. aureus protein A ( spa ) gene. A total of 69 clinical MRSA isolates were divided into 18 groups according to the number and nucleotide sequences of the spa repeats. Molecular typing results obtained both by spa sequencing and from the PFGE patterns were concordant except for one group, which contained 20 isolates recovered over a 2-year period from hospitalized patients at the Mayo Clinic. Although the spa typing patterns were indistinguishable for those isolates, PFGE analysis yielded seven related but distinguishable patterns. Further coagulase gene sequence analysis subtyped those 20 strains into four groups which followed distinct temporal and geographic distributions. During a 2-year epidemic period there were up to 7 fragment changes in PFGE patterns among epidemiologically related isolates, suggesting that PFGE may be unsuitable for long-term typing of strains involved in epidemics. Although more limited than PFGE in discriminatory power, spa sequencing analysis could be used as a screening method for typing of MRSA strains because of the shorter turnaround time, ease of use, and the inherent advantages of sequence analysis, storage, and sharing of information.
Molecular Diagnosis of Herpes Simplex Virus Infections in the Central Nervous System
Mitchell, P. Shawn, Espy, Mark J., Smith, Thomas F., Persing, David H., Tang, Yi‐Wei

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 7 | Pages: 2127-2136

10.1128/jcm.37.7.2127-2136.1999 | PMID 10364574 Get It

Comparative Evaluation of Colorimetric Microtiter Plate Systems for Detection of Herpes Simplex Virus in Cerebrospinal Fluid
Rys, Paul N., RUTLEDGE, BARBARA J., Mitchell, P. Shawn, Smith, Thomas F., Persing, David H., Tang, Yi‐Wei

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 9 | Pages: 2714-2717

10.1128/jcm.36.9.2714-2717.1998 | PMID 9705419 Get It

ABSTRACT In the past few years, application of the PCR to the detection of herpes simplex virus (HSV) DNA in the cerebrospinal fluid (CSF) from patients with encephalitis and meningitis has become standard laboratory practice. However, from an operational perspective, the true diagnostic value of PCR in this setting is yet to be realized because most laboratories subject the amplification products to lengthy probe hybridization procedures by Southern blotting. As alternatives to Southern blotting, we evaluated colorimetric microtiter plate (MTP) systems from ViroMed Laboratories, Inc. (PrimeCapture), CPG, Inc. (Quanti-PATH), and Incstar Corp. (GEN-ETI-K), in addition to a system developed at the Mayo Clinic with the PCR ELISA system (Boehringer Mannheim Corp.). We tested PCR products from 86 clinical CSF specimens submitted to our Molecular Microbiology Laboratory. The CSF specimens used had to have sufficient volume for comparative analysis. By conventional Southern blotting methods, 54 were positive and 32 were negative for HSV DNA. Compared with Southern blotting, the sensitivity and specificity were 63.0 and 100.0%, respectively, for the PrimeCapture system, 98.2 and 96.9%, respectively, for the Quanti-PATH system, 98.2 and 100.0%, respectively, for the GEN-ETI-K system, and 100.0 and 96.9%, respectively, for the Mayo system. All four MTP systems had turnaround times 12 to 24 h less than that for Southern blotting. There were no significant differences in costs or technologist time between the Mayo system and Southern blotting. Other features of the Mayo system include type-specific genotypic identification of HSV and the potential for determination of drug resistance by DNA sequencing. Overall, we found that colorimetric MTP systems were likely to improve test turnaround times and patient care at no additional cost.
Comparison of Phenotypic and Genotypic Techniques for Identification of Unusual Aerobic Pathogenic Gram-Negative Bacilli
Ellis, Nicole M., Hopkins, Marlene K., Smith, Douglas H. , Dodge, Deborah E., Persing, David H., Tang, Yi‐Wei

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 12 | Pages: 3674-3679

10.1128/jcm.36.12.3674-3679.1998 | PMID 9817894 Get It

ABSTRACT Rapid and accurate identification of bacterial pathogens is a fundamental goal of clinical microbiology, but one that is difficult or impossible for many slow-growing and fastidious organisms. We used identification systems based on cellular fatty acid profiles (Sherlock; MIDI, Inc., Newark, Del.), carbon source utilization (Microlog; Biolog, Inc., Hayward, Calif.), and 16S rRNA gene sequence (MicroSeq; Perkin-Elmer Applied Biosystems Division, Foster City, Calif.) to evaluate 72 unusual aerobic gram-negative bacilli isolated from clinical specimens at the Mayo Clinic. Compared to lengthy conventional methods, Sherlock, Microlog, and MicroSeq were able to identify 56 of 72 (77.8%), 63 of 72 (87.5%), and 70 of 72 (97.2%) isolates to the genus level ( P = 0.002) and 44 to 65 (67.7%), 55 of 65 (84.6%), and 58 of 65 (89.2%) isolates to the species level ( P = 0.005), respectively. Four Acinetobacter and three Bordetella isolates which could not be identified to the species level by conventional methods were identified by MicroSeq. In comparison to the full 16S rDNA sequences, the first 527 bp provided identical genus information for all 72 isolates and identical species information for 67 (93.1%) isolates. These data show that MicroSeq provides rapid, unambiguous identification of clinical bacterial isolates. The improved turnaround time provided by genotypic identification systems may translate into improved clinical outcomes.
Role of Genotypic Analysis of the Thymidine Kinase Gene of Herpes Simplex Virus for Determination of Neurovirulence and Resistance to Acyclovir
Lee, N. Y., Espy, Mark J., Kolbert, C. P., Rys, Paul N., Mitchell, P. Shawn, Henry, Semakula, Persing, David H., Smith, Thomas F., Tang, Yi‐Wei , Day, S. P.

Mayo Clinic

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3171-3174

10.1128/jcm.37.10.3171-3174.1999 | PMID 10488172 Get It

ABSTRACT Mutations in the thymidine kinase (TK) gene of herpes simplex virus (HSV) have been associated with resistance to acyclovir (ACY) and possible recognition of neurotropic strains. We sequenced a 335-bp segment of the TK gene to determine the frequency of mutations in HSV strains recovered from dermal, genital, and cerebrospinal fluid (CSF) specimens ( n = 200; 102 HSV type 1 [HSV-1] 98 HSV-2 strains). Four polymorphic sites were detected in HSV-1 strains; C513T, A528G, C575T, and C672T. Among the polymorphisms, only C575T resulted in a change of amino acid sequence (residue 192, Ala→Val). For HSV-2 strains, only one polymorphism (G420T) which resulted in an amino acid substitution (residue 139, Leu→Phe) was detected. Phenotypic determination of resistance to ACY by a plaque reduction assay of 48 HSV isolates was not correlated with the sequence results of 11 strains in that 7 of these with genotypic polymorphisms were susceptible to the drug in vitro. In addition, of 32 ACY-resistant HSV strains, 28 (87.5%) had no polymorphisms detected in the 335-bp amplicon of the TK gene. There was no statistical difference in the frequency of polymorphisms according to the source of the specimens. We conclude that the detection of nucleic acid polymorphisms in a previously implicated 335-bp segment of the TK gene cannot be interpreted as indicative of either ACY resistance or neurotropism of HSV strains from dermal, genital, and CSF sources.
Practical Guidance for Clinical Microbiology Laboratories: Viruses Causing Acute Respiratory Tract Infections
Charlton, Carmen , Babady, Esther , Ginocchio, Christine C. , Hatchette, Todd F. , Jerris, Robert C. , Loeffelholz, Mike J., McCarter, Yvette S., Novak-Weekley, Susan, Widen, R, Drews, Steven J. , Babady, N. Esther , Tang, Yi-Wei , Li, Yan , Miller, Melissa B. , Schuetz, Audrey N. , Tang, Yi‐Wei

Mayo Clinic

Clinical Microbiology Reviews | December 7, 2018 | Volume: 32 | Issue: 1 | Pages: No page available

10.1128/cmr.00042-18 | PMID 30541871 Get It

Respiratory viral infections are associated with a wide range of acute syndromes and infectious disease processes in children and adults worldwide. Many viruses are implicated in these infections, and these viruses are spread largely via respiratory means between humans but also occasionally from animals to humans.
Direct Identification of Bacteria from Positive Blood Cultures by Amplification and Sequencing of the 16S rRNA Gene: Evaluation of BACTEC 9240 Instrument True- Positive and False-Positive Results
Qian, Qinfang, Kolbert, Christopher P., Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Montgomery, Stacy O., Cockerill, Franklin R., Persing, David H., Tang, Yi‐Wei , Hughes, John

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 10 | Pages: 3578-3582

10.1128/jcm.39.10.3578-3582.2001 | PMID 11574575 Get It

ABSTRACT In a previous study which evaluated the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.), we noted a 1.3% “instrument false-positive” rate. That is, the BACTEC system signaled that a bottle (BACTEC Plus Aerobic/F bottle or BACTEC Anaerobic Lytic/10 bottle) culture was positive but a Gram stain was negative and there was no growth of bacteria or yeasts on subculture to chocolate agar. Furthermore, from the same sample of blood, cultures for fungi using the Isolator blood culture system (Wampole Laboratories, Cranbury, N.J.) were negative for growth. For the present study, we evaluated 76 instrument false-positive samples for the presence of 16S ribosomal DNA using the MicroSeq 500 kit (PE Biosystems, Foster City, Calif.). These samples also were negative for fungi by the Isolator method. This kit has a PCR module and sequencing module for the amplification and sequencing of the 16S RNA gene and provides a database for sequence alignment and identification of bacteria. To optimize the assay, we evaluated the effect of adding 0.5% bovine serum albumin to the sample from blood culture bottles and found that it decreased the effects of inhibitors on the PCR. Two control groups of blood culture specimens were also evaluated. One group ( n = 45) were “instrument true positives”; the instrument signaled positive, and subsequent Gram stains were positive and subcultures on chocolate agar grew bacteria. The other group ( n = 20) were “instrument true negatives”; the instrument signaled negative, the Gram stain was negative, and subcultures on chocolate agar and from the Isolator tube on fungal media showed no growth. None of the 76 instrument false-positive samples had evidence for 16S rRNA gene sequences. All of the instrument true-positive samples and all of the instrument true-negative specimens were positive and negative, respectively, using the MicroSeq 500 kit. Total peripheral white blood cell counts were statistically significantly higher for patients who had instrument false-positive results than for patients who had instrument true-positive or true-negative results ( P = 0.001). We conclude that instrument false positives signaled by the BACTEC 9240 system are not due to bacteria in the blood culture samples.