Citations

Clear

89 citation(s) found for "Simard, T".

Clinical Outcomes of Mitral Regurgitation Severity and Transcatheter Edge‐to‐Edge Repair in Atrial Functional Mitral Regurgitation
Naser, Jwan A. , Massad, Faysal, Borlaug, Barry A. , Simard, Trevor , Siontis, Konstantinos C. , Kennedy, Austin M , Thaden, Jeremy J. , Eleid, Mackram F. , Borlaug, Barry A , Simard, Trevor , Eleid, Mackram F , Naser, Jwan A , Scott, Christopher G. , Michelena, Héctor I. , Pellikka, Patricia A. , Nkomo, Vuyisile T. , Pislaru, Sorin V.

Mayo Clinic

Catheterization and Cardiovascular Interventions | May 5, 2025 | Volume: 106 | Issue: 1 | Pages: 494-503

10.1002/ccd.31567 | PMID 40320723 Get It

ABSTRACT Background Incident atrial functional mitral regurgitation (AFMR) is associated with mortality. Transcatheter edge‐to‐edge repair (TEER) has shown effectiveness in improving MR and symptoms in AFMR, but previous studies lacked comparison to conservative management. We aimed to study the association of AFMR severity and mitral TEER with symptoms, heart failure hospitalizations (HFH) and all‐cause mortality in moderate/severe AFMR. Methods Consecutive adults with moderate/severe AFMR managed conservatively or with TEER 2010−2023 were identified retrospectively. To ensure similar technique in evaluation in the two groups, variables were obtained from the closest transthoracic echocardiogram before TEER in the TEER group. In addition to multivariable analysis, the association of TEER (vs. conservative management) with HFH and mortality was assessed using propensity‐score matched analyses; the propensity score was based on age, sex, EuroSCORE II, effective regurgitant orifice area, integrative MR severity, and NYHA class III/IV (vs. I/II). Results Among 230 patients with moderate/severe AFMR [mean age 77; 56% females], 46 were managed with TEER. Severe (vs. moderate) AFMR was independently associated with baseline NYHA class III/IV (multivariable OR 2.18 [95% CI 1.13−4.26]) and HFH [multivariable HR 2.75 (95% CI 1.25−6.03)] but not mortality ( p = 0.26). TEER improved MR to ≤ moderate in 93% but was not associated with lower HFH or death rates versus conservative management on multivariable or matched analysis. However, 1‐year NYHA improved more with TEER versus conservative management in patients with baseline NYHA class III/IV (62% vs. 27%, p = 0.03). Rhythm control was associated with improved survival (HR 0.38 [0.15−0.98]). Conclusions AFMR severity was associated with symptoms and HFH but not mortality. MR severity and NYHA class improved with TEER, but the association of TEER with HF hospitalizations or death remains unproven. Randomized studies are needed to evaluate the potential role of TEER and rhythm control on outcomes in AFMR.
Exercise Mildly Increases Transaortic Gradients in Aortic Stenosis With Preserved Ejection Fraction: An Invasive Hemodynamic Study
Al‐Abcha, Abdullah , Jain, C. Charles , Nishimura, Rick A., Simard, Trevor , Eleid, Mackram F. , Hibbert, Benjamin , Oh, Jae K., Carabello, Blasé A. , Miranda, William R. , Simard, Trevor , Hibbert, Benjamin , Al-Abcha, Abdulah , Oh, Jae K.

Mayo Clinic

Catheterization and Cardiovascular Interventions | April 9, 2025 | Volume: 106 | Issue: 1 | Pages: 181-188

10.1002/ccd.31511 | PMID 40202054 Get It

ABSTRACT Background The assessment of aortic stenosis (AS) severity remains a challenge in some patients, and hemodynamic exercise testing has been proposed as a diagnostic tool in this population. However, the current understanding of exercise hemodynamics in AS is limited. Methods Retrospective review of 34 adults (aged ≥ 18 years) with ≥ moderate AS and preserved left ventricular ejection fraction (LVEF) undergoing exercise invasive hemodynamics (supine cycle protocol) with simultaneous measurement of aortic and left ventricular pressures. Results Age was 77.1 (IQR 68.6; 84.1) years, and 50% were female. LVEF was 62.1 ± 6.6%. All patients were symptomatic. Resting aortic valve area (AVA) was 1.0 ± 0.2 cm 2 and aortic valve (AV) systolic mean gradient 22.0 ± 7.3 mmHg. At peak exercise (40 [IQR 30; 60] W), AV systolic mean gradient (Δ3 [0.6; 7] mmHg, p < 0.001) and AVA (Δ0.2 [0; 0.6] cm 2 , p = 0.002) significantly increased, while stroke volume (SV) did not (Δ6.8 ± 19.4 ml; p = 0.07). Exercise‐induced changes in AV systolic mean gradient were directly related to changes in cardiac output ( r = 0.53, p = 0.003), being inversely related to exercise systemic vascular resistance ( r = −0.60, p = 0.002). Elevated pulmonary artery wedge pressure was present in 41.2% at rest (≥ 15 mmHg) and 69.7% during exercise (≥ 25 mmHg). Conclusions Symptomatic patients with ≥ moderate AS and preserved LVEF experience small increases in AV mean gradient with exercise, and unlike the normal physiological response to exercise, there was no significant increase in SV. In most patients, AVA rose during exercise. Exercise‐induced elevation in filling pressures was highly prevalent.
Concomitant Transcatheter Edge-to-Edge Repair and Left Atrial Appendage Occlusion
Prosperi-Porta, Graeme, Dryden, Adam , Nicholson, Donna, Hynes, Mark, Chan, Vincent , Jung, Richard G. , Santo, Pietro Di , Simard, Trevor , Labinaz, Marino , Hibbert, Benjamin , Abdel‐Razek, Omar , Hibbert, Benjamin , Simard, Trevor , Abdel-Razek, Omar , Chan, Vincent , Prosperi‐Porta, Graeme

Mayo Clinic

Journal of Clinical Medicine | March 26, 2025 | Volume: 14 | Issue: 7 | Pages: 2257

10.3390/jcm14072257 | PMID 40217706 Get It

Background/Objectives: Atrial fibrillation is a frequent comorbidity amongst patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) for mitral regurgitation. Left atrial appendage occlusion (LAAO) can be performed to reduce the risk of stroke in patients with atrial fibrillation. Both procedures require large-bore venous access, transseptal puncture, and real-time imaging of the left atrium. However, limited data exist evaluating the safety and feasibility of concomitant M-TEER and LAAO. Methods: We performed a retrospective review of all concomitant M-TEER and LAAO procedures at our institution between May 2019 and September 2024 to evaluate the safety and feasibility of this approach. Results: Concomitant left atrial appendage occlusion was successful in all 15 patients, requiring an additional 15 min (IQR 11–29) of procedural time. No patients died or had a major vascular complication. Routine transesophageal echocardiography performed within 90 days showed no device related thrombus, and no significant peri-device leak in any patients. Conclusions: Concomitant M-TEER and LAAO are feasible but additional prospective studies or randomized trials are needed to evaluate the potential clinical benefit.
A comparison of carbon ions versus protons for integrated mode ion imaging
Simard, Mikaël , Fullarton, Ryan , Robertson, Daniel , Toltz, Allison, Baker, Colin , Graeff, Christian , Collins‐Fekete, Charles‐Antoine , Robertson, Daniel G, Graeff, Christian , Volz, Lennart , Schuy, Christoph , Baker, Colin, Beddar, Sam

Mayo Clinic

Medical Physics | February 4, 2025 | Volume: 52 | Issue: 5 | Pages: 3097-3106

10.1002/mp.17645 | PMID 39904601 Get It

Abstract Background Incorporating image guidance into ion beam therapy is critical for minimizing beam range uncertainties and realizing the modality's potential. One promising avenue for image guidance is to capture transmission ion radiographs (iRads) before and/or during treatment. iRad image quality is typically maximized using a single‐event imaging system, which involves tracking individual ions, albeit the approach is generally not suited to clinical beam settings. An alternative faster and clinically compatible method is integrated mode imaging, where individual pencil beam data is acquired, rather than single ion data. To evaluate the usefulness of transmission ion imaging for image guidance, it is crucial to evaluate the image quality of integrated mode iRad systems. Purpose We report extensive image quality metrics of integrated mode carbon ion radiographs (cRads) and compare them with proton radiographs (pRads). Methods iRads were obtained at the Marburg Ion Beam Therapy Center using a plastic volumetric scintillator equipped with CCD cameras. The detector captures orthogonal views of the 3D energy deposition in the scintillator from individual pencil beams. Four phantoms were scanned using a field of view and a beam spacing of 1 mm. First, 9 tissue‐substitute inserts were used to evaluate water equivalent thickness (WET) accuracy. Radiographs of those inserts were reconstructed for beam spacings ranging from 1 to 7 mm to evaluate the impact of spacing on quantitative accuracy. For spatial resolution, custom 3D printed line pair (lp) modules ranging from 0.5 to 10 lp/cm were scanned. To evaluate low contrast detectability, a custom 3D printed low contrast module consisting of 20 holes with depths ranging from 1 to 8 mm and diameters from 1 to 10 mm was scanned. iRads of an anthropomorphic head phantom were also obtained. Results Spatial resolution and low contrast detection are systematically improved for cRads compared to pRads. Image resolution was 3.7 lp/cm for cRads and 1.7 lp/cm for pRads in the center of the field of view. Spatial resolution was found to vary with the object's location in the field of view. While pRads could mostly resolve low contrast holes of 10 mm in diameter, cRads could resolve holes of up in 4 mm diameter. WET accuracy is similar for both ion species, with a root mean squared error of approximately 1 mm. WET accuracy was stable (maximum of 0.1 mm increase) across beam spacings, although important under‐sampling artifacts were observed for iRads reconstructed using large beam spacings, especially for cRads. iRads of the anthropomorphic head phantom showed improved apparent contrast using cRads, especially to identify bony structures. Conclusions This work is the first investigation of image quality metrics such as spatial resolution and low contrast detectability for integrated mode cRads, with a full comparison with pRads. Enhanced image quality is obtained with cRads compared to pRads, although pRads still maintain high WET accuracy and deliver image quality within acceptable bounds.
Abstract 4139565: Association of transcatheter edge-to-edge repair with clinical outcomes in atrial functional mitral regurgitation
Massad, Faysal, Kennedy, Austin M , Naser, Jwan A. , Scott, Christopher G. , Borlaug, Barry A. , Pellikka, Patricia A. , Simard, Trevor , Enriquez‐Sarano, Maurice , Nkomo, Vuyisile T. , Michelena, Héctor I. , Pislaru, Sorin V.

Mayo Clinic

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4139565 Get It

Background: Atrial functional mitral regurgitation (AFMR) constitutes ~25% of ≥moderate MR and has been associated with a high prevalence and incidence of HFpEF. Transcatheter edge-to-edge repair (TEER) has shown effectiveness in improving symptoms in AFMR, but its impact on mortality and HF hospitalizations is unknown. Objective: Evaluate rates of mortality and HF hospitalizations in patients with ≥moderate AFMR treated with TEER and compare them to conservative management. Methods: Consecutive adults with ≥moderate AFMR (functional MR with left atrial enlargement, ejection fraction≥50%, and absent >mild left ventricular enlargement) were identified retrospectively. Ecxlusion criteria were previous cardiac surgery, ≥moderate aortic regurgitation/stenosis, infiltrative/hypertrophic cardiomyopathy, regional wall motion abnormalities or malignancy. Propensity score matching was performed (1:1 ratio) between patients treated with TEER and patients treated conservatively based on age, sex, EuroScore II, effective regurgitant orifice area, and the integrative MR severity. To ensure similar technique in evaluation in the 2 groups, variables were obtained from the closest transthoracic echocardiogram before TEER in the TEER group [median 65 (IQR 29-111) days]. Results: Overall, 46 patients with ≥moderate AFMR treated by TEER and 46 treated conservatively were included, Table 1 . Patients undergoing TEER had more frequent atrial fibrillation and NYHA class ≥III. MR improved to ≤moderate in 93% of patients undergoing TEER on procedural transesophageal echocardiography, Figure 1 . On 1–3-month post-TEER follow-up, 64% had NYHA class I/II (vs 33% pre-TEER), Figure 1 . Over median 2.2 (IQR 1.2-3.1) years, 32 patients died (rate 13%/year in each group, log-rank p=0.85), Figure 2 . When adjusted for baseline NYHA, rates of HF hospitalizations were not different between the groups (Wald-test p-value=0.48). Residual ≥moderate AFMR in the TEER group was not associated with mortality (log-rank p=0.83), but ≥1 class improvement of NYHA in patients with baseline NYHA >1 was associated with decreased mortality, Figure 2 . Conclusion: MR severity and NYHA class improved with TEER for AFMR, and improved NYHA class was associated with decreased mortality. However, the association of TEER with decreased risk of mortality or HF hospitalization remains unproven, and larger randomized studies are needed to evaluate the potential role of TEER on these outcomes in AFMR.
Imaging lung tumor motion using integrated‐mode proton radiography—A phantom study towards tumor tracking in proton radiotherapy
Fullarton, Ryan , Simard, Mikaël , Toltz, Allison, Chung, Savanna, Schuy, Christoph , Robertson, Daniel , Royle, Gary , Baker, Colin , Graeff, Christian , Collins‐Fekete, Charles‐Antoine , Robertson, Daniel G, Graeff, Christian , Volz, Lennart , Chung, Savanna, Beddar, Sam , Baker, Colin

Mayo Clinic

Medical Physics | November 12, 2024 | Volume: 52 | Issue: 2 | Pages: 1146-1158

10.1002/mp.17508 | PMID 39530503 Get It

AbstractBackgroundMotion of lung tumors during radiotherapy leads to decreased accuracy of the delivered dose distribution. This is especially true for proton radiotherapy due to the finite range of the proton beam. Methods for mitigating motion rely on knowing the position of the tumor during treatment.PurposeProton radiography uses the treatment beam, at an energy high enough to traverse the patient, to produce a radiograph. This work shows the first results of using an integrated‐mode proton radiography system to track the position of moving objects in an experimental phantom study; demonstrating the potential of using this method for measuring tumor motion.MethodsProton radiographs of an anthropomorphic lung phantom, with a motor‐driven tumor insert, were acquired approximately every 1 s, using tumor inserts of 10, 20, and 30 mm undergoing a known periodic motion. The proton radiography system used a monolithic scintillator block and digital cameras to capture the residual range of each pencil beam passing through the phantom. These ranges were then used to produce a water equivalent thickness map of the phantom. The centroid of the tumor insert in the radiographs was used to determine its position. This measured position was then compared to the known motion of the phantom to determine the accuracy.ResultsSubmillimeter accuracy on the measurement of the tumor insert was achieved when using a 30 mm tumor insert with a period of 24 s and was found to be improved for decreasing motion amplitudes with a mean absolute error (MAE) of 1.0, 0.9, and 0.7 mm for 20, 15, and 10 mm respectively. Using smaller tumor inserts reduced the accuracy with a MAE of 1.8 and 1.9 mm for a 20 and 10 mm insert respectively undergoing a periodic motion with an amplitude of 20 mm and a period of 24 s. Using a shorter period resulted in significant motion artifacts reducing the accuracy to a MAE of 2.2 mm for a 12 s period and 3.1 mm for a 6 s period for the 30 mm insert with an amplitude of 20 mm.ConclusionsThis work demonstrates that the position of a lung tumor insert in a realistic anthropomorphic phantom can be measured with high accuracy using proton radiographs. Results show that the accuracy of the position measurement is the highest for slower tumor motions due to a reduction in motion artifacts. This indicates that the primary obstacle to accurate measurement is the speed of the radiograph acquisition. Although the slower tumor motions used in this study are not clinically realistic, this work demonstrates the potential for using proton radiography for measuring tumor motion with an increased scanning speed that results in a decreased acquisition time.
Transcatheter versus surgical aortic valve replacement in patients younger than 65 years: analysis from the national inpatient sample database
Ismayl, Mahmoud , Ahmed, Hussien , Simard, Trevor , Guerrero, Mayra , Ahmed, H

Mayo Clinic

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.2457 Get It

Abstract Background Data on the relative utilization and outcomes of transcatheter aortic valve replacement (TAVR) versus surgical AVR (SAVR) in patients &lt;65 years are limited. Purpose To compare the relative utilization and outcomes of TAVR versus SAVR in patients &lt;65 years in the United States. Methods We queried the National Inpatient Sample (2016-2020) to identify patients &lt;65 years hospitalized for isolated AVR. In-hospital outcomes of TAVR versus SAVR were compared using multivariable regression and propensity-matching analyses. Results Of 74,155 patients aged &lt;65 years hospitalized for isolated AVR, 17,300 (23.3%) underwent isolated TAVR, and 56,855 (76.7%) underwent isolated SAVR. From 2016-2020, the use of TAVR increased, while the use of SAVR decreased in patients &lt;65 years (both ptrend&lt;0.01). Factors independently associated with TAVR selection in patients &lt;65 years included female sex, congestive heart failure, pulmonary disease, renal failure, liver disease, cancer, and prior revascularization. Factors independently associated with SAVR selection included bicuspid aortic valve. After adjustment for baseline characteristics, TAVR was associated with lower odds of in-hospital mortality (adjusted odds ratio [aOR] 0.61, 95% confidence interval [CI] 0.38-0.97), stroke (aOR 0.58, 95% CI 0.38-0.90), acute kidney injury (aOR 0.41, 95% CI 0.34-0.49), and major bleeding (aOR 0.62, 95% CI 0.38-0.96), and higher vascular complications compared with SAVR (aOR 2.39, 95% CI 1.75-3.24). Length of stay was shorter and nonhome discharges were lower with TAVR (all p&lt;0.01). Similar findings were observed in the propensity-matched cohort. Conclusions This nationwide observational analysis showed that TAVR is a feasible treatment option for patients &lt;65 years with lower in-hospital mortality and resource utilization compared with SAVR.Central Illustration
Left Atrial Appendage Occlusion vs Standard of Care After Ischemic Stroke Despite Anticoagulation
Seiffge, David , Group, STR-OAC LAAO, Macha, Kosmas , Takagi, Masahito, Arihiro, Shoji , Polymeris, Alexandros A. , Yoshimura, Sohei , Venti, Michele , Thilemann, Sebastian , Altavilla, Riccardo , Peters, Nils , Inoue, Manabu, Bobinger, Tobias , Agnelli, Giancarlo , Acciarresi, Monica, Jager, Hans, Bovi, Paolo, Schwab, Stefan , Registry, RAF, RAF-DOAC, CROMIS-2, SAMURAI, NOACISP, Erlangen Registry, and Verona, Aarnink, Errol W. , Fierro, Nicolai, Tondo, Claudio , Zieliński, Kamil , Korsholm, Kasper , Nielsen-Kudsk, Jens Erik, Caneiro‐Queija, Berenice, Benito‐González, Tomás , Holmes, David R. , Almakadma, Abdul H., Álvarez, Xavier Millán, Alla, Venkata , Agarwal, Himanshu , Paitazoglou, Christina , Freixa, Xavier , Cepas‐Guillén, Pedro , Chothia, Rashaad , Badejoko, Solomon O. , Bergmann, Martin , Spoon, Daniel B., Maddux, James T., Ram, Pradhum , Branca, Luca , Dijk, Vincent F. van , Rensing, Benno J. , Paciaroni, Maurizio , Kallmünzer, Bernd , Wilson, Duncan , Jäger, Hans Rolf , Korsholm, Kasper , Seiffge, David , Jäger, Hans Rolf , Cepas-Guillen, Pedro , Maarse, Moniek , Werring, David J. , Boersma, Lucas V.A. , Group, STR-OAC LAAO, Tsivgoulis, Georgios , Bonetti, Bruno , Alberti, Andrea , Ambler, Gareth , Bonati, Leo H. , Muir, Keith W. , Yamagami, Hiroshi, Inoue, Manabu , Brown, Martin M. , Sato, Shoichiro , Lyrer, Philippe A. , Marchis, Gian Marco De , Peper, Joyce , Simard, Trevor , Alkhouli, Mohamad , Registry, RAF, RAF-DOAC, CROMIS-2, SAMURAI, NOACISP, Erlangen Registry, and Verona, Mazzone, Patrizio , Beneduce, Alessandro , Gasperetti, Alessio , Pracoń, Radosław , Demkow, Marcin , Backer, Ole De , Nielsen‐Kudsk, Jens Erik , Estévez‐Loureiro, Rodrigo , Prado, Armando Pérez de , Nombela‐Franco, Luis , Salinas, Pablo , Berti, Sérgio , Romeo, Maria Rita , Arzamendi, Dabit , Eitel, Ingo , Bergmann, Martin W., El‐Chami, Mikhael F. , Adamo, Marianna , Suradi, Hussam , Zietz, Annaelle , Caso, Valeria , Koga, Masatoshi , Toyoda, Ḱazunori , Cappellari, Manuel , Engelter, Stefan T. , Swaans, Martin John

Mayo Clinic

JAMA Neurology | September 23, 2024 | Volume: 81 | Issue: 11 | Pages: 1150

10.1001/jamaneurol.2024.2882 | PMID 39374446 Get It

ImportancePatients with atrial fibrillation (AF) who have ischemic stroke despite taking oral anticoagulation therapy (OAT) have a very high risk of recurrence. Left atrial appendage occlusion (LAAO) is a mechanical stroke prevention strategy that may provide additional protection in patients with thromboembolic events under OAT.ObjectiveTo compare percutaneous LAAO with continuing OAT alone regarding stroke prevention in patients with AF who had a thromboembolic event despite taking OAT.Design, Setting, and ParticipantsThis cohort study was a propensity score–matched comparison of the STR-OAC LAAO cohort, an international collaboration of 21 sites combining patients from multiple prospective registries of patients who underwent LAAO between 2010 and 2022. STR-OAC LAAO cohort patients who had follow-up longer than 3 months were propensity score–matched to a previously published control cohort comprising patients from an established international collaboration of investigator-initiated prospective studies. This control cohort included patients with nonvalvular AF, recent ischemic stroke or transient ischemic attack, and follow-up longer than 3 months who were taking OAT before the index event. Analyses were adjusted for imbalances in gender, age, hypertension, diabetes, and CHA2 DS2-VASc score.ExposureLeft atrial appendage occlusion vs continuation of oral anticoagulation therapy alone (control group).Main Outcomes and MeasuresThe primary outcome was time to first ischemic stroke.ResultsFour hundred thirty-three patients from the STR-OAC LAAO cohort (mean [SD] age, 72 [9] years; 171 [39%] females and 262 [61%] males; mean [SD] CHA2 DS2-VASc score, 5.0 [1.6]) were matched to 433 of 1140 patients (38%) from the control group. During 2-year follow-up, 50 patients experienced ischemic stroke: an annualized event rate of 2.8% per patient-year in the STR-OAC LAAO group vs 8.9% per patient-year in the control group. Left atrial appendage occlusion was associated with a lower risk of ischemic stroke (hazard ratio, 0.33; 95% CI, 0.19-0.58; P &amp;lt; .001) compared with the control group. After LAAO, OAT was discontinued in 290 patients (67%), and the remaining 143 patients (33%) continued OAT after LAAO as an adjunctive therapy.Conclusions and RelevanceIn patients with nonvalvular AF and a prior thromboembolic event despite taking OAT, LAAO was associated with a lower risk of ischemic stroke compared with continued OAT alone. Randomized clinical trial data are needed to confirm that LAAO may be a promising treatment option for this population with a very high risk of stroke.
Cost-effectiveness of population screening for aortic stenosis
Motazedian, Pouya, Hibbert, Benjamin , Jalal, Hawre , Labinaz, Marino , Burwash, Ian G. , Abdel‐Razek, Omar , Santo, Pietro Di , Wells, George A. , Hibbert, Benjamin , Jalal, Hawre , Abdel-Razek, Omar , Wells, George , Motazedian, Pouya , Prosperi‐Porta, Graeme , Simard, Trevor , Coyle, Doug

Mayo Clinic

European Heart Journal - Quality of Care and Clinical Outcomes | May 23, 2024 | Volume: 11 | Issue: 4 | Pages: 378-387

10.1093/ehjqcco/qcae043 | PMID 38777625 Get It

Abstract Aims Aortic stenosis (AS) is a progressive disease predominantly affecting elderly patients that carries significant morbidity and mortality without aortic valve replacement, the only proven treatment. Our objective was to determine the cost-effectiveness of AS screening using transthoracic echocardiography (TTE) in a geriatric population from the perspective of the publicly funded healthcare system in Canada. Methods and results Markov models estimating the cost-effectiveness ratio (ICER) for AS screening with a one-time TTE were developed. The model included diagnosed and undiagnosed AS health states, hospitalizations, transcatheter aortic valve replacement (TAVR), and post-TAVR health states. Primary analysis included screening at 70 and 80 years of age with intervention at symptom onset, with scenario analysis included for early intervention at the time of severe asymptomatic AS diagnosis. Monte Carlo simulation of 5000 replications was completed with a lifetime horizon and a 1.5% discount for costs and outcomes.Screening for AS at the age of 70 years was associated with an ICER of $156 722, and screening at 80 years of age was associated with an ICER of $28 005, suggesting that screening at 80 years of age is cost-effective when willingness-to-pay per QALY is $50 000. Scenario analysis with early intervention was not cost-effective, with an ICER of $142 157 at 70 years and $124 651 at 80 years. Conclusion Screening for AS at 80 years of age with a one-time TTE, in a Canadian population, improves quality of life and is cost-effective in a publicly funded healthcare system providing, TAVR is reserved for symptomatic patients.
Abstract 12227: New Insights Into Calcification and Aortic Stenosis Using 4-dimensional Computed Tomography.
Jenkins, William , Simard, Louis, Hourdain, Jérôme , Simard, Louis, Clavel, Marie‐Annick , Enriquez‐Sarano, Maurice

Mayo Clinic

Circulation | April 23, 2024 | Volume: 134 | Issue: suppl_1 | Pages: No page available

10.1161/circ.134.suppl_1.12227 Get It

Background: Aortic Valve Calcification (AVC) is intrinsic to aortic stenosis (AS). While established concepts assume homogeneous calcification causing AS, wide variability in hemodynamic severity at any given AVC burden suggests other operative mechanisms. Multidetector computed tomography (MDCT) now accurately measures global AVC, but AVC spatial distribution remains elusive due to imaging orientation. Methods and Results: We developed ‘en-face’ imaging by re-registration of 4D-MDCT to quantify AVC spatial distribution and analyzed global AVC load and AVC distribution in 418 patients with AS (76±9 years; mean gradient 35±17 mmHg). 4D-volume-rendered MDCT datasets were re-oriented to en-face view of aortic valve for AVC spatial scoring with individual cusp calcification load, cusp-edge calcification and AVC asymmetry. Despite high total AVC load (450 [250-666] AU/cm 2 ), asymmetry was frequent (50%), with a difference between most- and least-calcified cusp of 112 [66-182] AU/cm 2 . Maximum AVC was in the non-coronary cusp in 61% (p<0.001). Cusp edge calcification was none-mild in 26%, moderate in 62% and severe in 12%. Adjusting for total AVC, severe AS (mean gradient >40 mmHg) was more likely with symmetrical AVC (odds ratio [OR] 2.36, p<0.001) and with edge calcification moderate (OR 4.16, p=0.001 vs none-mild) to severe (OR 10.7, p=0.001). Inclusion of AVC distribution improved models predicting AS severity over total AVC (p<0.001). Conclusions: Four-dimensional MDCT en-face re-registration and AVC quantitation provides new insight into AS pathophysiology. Contrary to classical concepts, AVC is frequently inhomogeneous and asymmetric. Hemodynamic AS severity is independently affected not only by global AVC but also by variations in AVC distribution and location within cusps, emphasizing the importance of 4D AVC assessment in AS. Impact of quantified AVC asymmetry and location on outcome of transcutaneous aortic valve replacement should be evaluated.