Citations

Clear

22 citation(s) found for "Richardson, Mark".

Spike ripples localize the epileptogenic zone best: an international intracranial study
Shi, Wen , Shaw, Dana , Walsh, Katherine G. , Han, Xue , Eden, Uri T. , Gliske, S. , Jacobs, Julia , Brinkmann, Benjamin H. , Worrell, Gregory A. , Kramer, Mark , Chu, Catherine J. , Gliske, Stephen V , Brinkmann, Benjamin H , Worrell, Gregory A , Kramer, Mark A , Chu, Catherine J , Richardson, Robert Mark , Stacey, William C. , Frauscher, Birgit , Thomas, John Paul

Mayo Clinic

Brain | February 7, 2024 | Volume: 147 | Issue: 7 | Pages: 2496-2506

10.1093/brain/awae037 | PMID 38325327 Get It

Abstract We evaluated whether spike ripples, the combination of epileptiform spikes and ripples, provide a reliable and improved biomarker for the epileptogenic zone compared with other leading interictal biomarkers in a multicentre, international study. We first validated an automated spike ripple detector on intracranial EEG recordings. We then applied this detector to subjects from four centres who subsequently underwent surgical resection with known 1-year outcomes. We evaluated the spike ripple rate in subjects cured after resection [International League Against Epilepsy Class 1 outcome (ILAE 1)] and those with persistent seizures (ILAE 2–6) across sites and recording types. We also evaluated available interictal biomarkers: spike, spike-gamma, wideband high frequency oscillation (HFO, 80–500 Hz), ripple (80–250 Hz) and fast ripple (250–500 Hz) rates using previously validated automated detectors. The proportion of resected events was computed and compared across subject outcomes and biomarkers. Overall, 109 subjects were included. Most spike ripples were removed in subjects with ILAE 1 outcome (P < 0.001), and this was qualitatively observed across all sites and for depth and subdural electrodes (P < 0.001 and P < 0.001, respectively). Among ILAE 1 subjects, the mean spike ripple rate was higher in the resected volume (0.66/min) than in the non-removed tissue (0.08/min, P < 0.001). A higher proportion of spike ripples were removed in subjects with ILAE 1 outcomes compared with ILAE 2–6 outcomes (P = 0.06). Among ILAE 1 subjects, the proportion of spike ripples removed was higher than the proportion of spikes (P < 0.001), spike-gamma (P < 0.001), wideband HFOs (P < 0.001), ripples (P = 0.009) and fast ripples (P = 0.009) removed. At the individual level, more subjects with ILAE 1 outcomes had the majority of spike ripples removed (79%, 38/48) than spikes (69%, P = 0.12), spike-gamma (69%, P = 0.12), wideband HFOs (63%, P = 0.03), ripples (45%, P = 0.01) or fast ripples (36%, P < 0.001) removed. Thus, in this large, multicentre cohort, when surgical resection was successful, the majority of spike ripples were removed. Furthermore, automatically detected spike ripples localize the epileptogenic tissue better than spikes, spike-gamma, wideband HFOs, ripples and fast ripples.
Seizure forecasting and detection with wearable devices and subcutaneous EEG - A Practical Seizure Gauge (N2.004)
Grzeskowiak, Caitlin L. , Brinkmann, Benjamin H. , Nurse, Ewan S. , Nasseri, Mona , Viana, Pedro F. , Karoly, Philippa J. , Attia, Tal Pal , Gregg, Nicholas M. , Joseph, Boney , Dümpelmann, Matthias , Cook, Mark , Worrell, Gregory A. , Schulze‐Bonhage, Andreas , Freestone, Dean R. , Richardson, Mark P.

Mayo Clinic

Neurology | December 6, 2023 | Volume: 98 | Issue: 18_supplement | Pages: No page available

10.1212/wnl.98.18_supplement.528 Get It

Perceived seizure risk in epilepsy: Chronic electronic surveys with and without concurrent electroencephalography
Cui, Jie , Balzekas, Irena , Nurse, Ewan S. , Viana, Pedro F. , Gregg, Nicholas M. , Karoly, Philippa J. , Stirling, Rachel E. , Worrell, Gregory A. , Richardson, Mark P. , Brinkmann, Benjamin H. , Nurse, Ewan , Viana, Pedro F , Gregg, Nicholas M , Karoly, Phillipa J , Worrell, Gregory A , Brinkmann, Benjamin H , Richardson, Mark P , Cui, Jie , Stirling, Rachel E , Freestone, Dean R.

Mayo Clinic

Epilepsia | June 12, 2023 | Volume: 64 | Issue: 9 | Pages: 2421-2433

10.1111/epi.17678 | PMID 37303239 Get It

Abstract Objective Previous studies suggested that patients with epilepsy might be able to forecast their own seizures. This study aimed to assess the relationships between premonitory symptoms, perceived seizure risk, and future and recent self‐reported and electroencephalographically (EEG)‐confirmed seizures in ambulatory patients with epilepsy in their natural home environments. Methods Long‐term e‐surveys were collected from patients with and without concurrent EEG recordings. Information obtained from the e‐surveys included medication adherence, sleep quality, mood, stress, perceived seizure risk, and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed‐effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with the seizure forecasting classifiers and device forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC). Results Fifty‐four subjects returned 10 269 e‐survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed that increased stress (OR = 2.01, 95% confidence interval [CI] = 1.12–3.61, AUC = .61, p = .02) was associated with increased relative odds of future self‐reported seizures. Multivariate analysis showed that previous self‐reported seizures (OR = 5.37, 95% CI = 3.53–8.16, AUC = .76, p < .001) were most strongly associated with future self‐reported seizures, and high perceived seizure risk (OR = 3.34, 95% CI = 1.87–5.95, AUC = .69, p < .001) remained significant when prior self‐reported seizures were added to the model. No correlation with medication adherence was found. No significant association was found between e‐survey responses and subsequent EEG seizures. Significance Our results suggest that patients may tend to self‐forecast seizures that occur in sequential groupings and that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self‐predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting.
Seizure Forecasting and Detection with Wearable Devices and Subcutaneous EEG – Outcomes from the My Seizure Gauge Trial (PL4.001)
Gregg, Nicholas M. , Gregg, Nicholas M , Brinkmann, Benjamin H. , Nurse, Ewan S. , Viana, Pedro F. , Nasseri, Mona , Kuhlmann, Levin , Karoly, Philippa J. , Attia, Tal Pal , Joseph, Boney , Dümpelmann, Matthias , Cook, Mark , Worrell, Gregory A. , Schulze‐Bonhage, Andreas , Richardson, Mark, Freestone, Dean R.

Mayo Clinic

Neurology | April 28, 2023 | Volume: 100 | Issue: 17_supplement_2 | Pages: No page available

10.1212/wnl.0000000000203901 Get It

Seizure occurrence is linked to multiday cycles in diverse physiological signals
Gregg, Nicholas M. , Attia, Tal Pal , Nasseri, Mona , Karoly, Philippa J. , Cui, Jie , Stirling, Rachel E. , Viana, Pedro F. , Nurse, Ewan S. , Cook, Mark , Richardson, Mark P. , Brinkmann, Benjamin H. , Pal Attia, Tal , Joseph, Boney , Karoly, Phillipa J , Cui, Jie , Stirling, Rachel E , Viana, Pedro F , Richner, Thomas J, Nurse, Ewan , Schulze-Bonhage, Andreas , Cook, Mark J , Worrell, Gregory A , Richardson, Mark P , Freestone, Dean R , Brinkmann, Benjamin H , Gregg, Nicholas M , Joseph, Boney , Richner, Thomas J. , Schulze‐Bonhage, Andreas , Worrell, Gregory A. , Freestone, Dean R.

Mayo Clinic

Epilepsia | April 15, 2023 | Volume: 64 | Issue: 6 | Pages: 1627-1639

10.1111/epi.17607 | PMID 37060170 Get It

Abstract Objective The factors that influence seizure timing are poorly understood, and seizure unpredictability remains a major cause of disability. Work in chronobiology has shown that cyclical physiological phenomena are ubiquitous, with daily and multiday cycles evident in immune, endocrine, metabolic, neurological, and cardiovascular function. Additionally, work with chronic brain recordings has identified that seizure risk is linked to daily and multiday cycles in brain activity. Here, we provide the first characterization of the relationships between the cyclical modulation of a diverse set of physiological signals, brain activity, and seizure timing. Methods In this cohort study, 14 subjects underwent chronic ambulatory monitoring with a multimodal wrist‐worn sensor (recording heart rate, accelerometry, electrodermal activity, and temperature) and an implanted responsive neurostimulation system (recording interictal epileptiform abnormalities and electrographic seizures). Wavelet and filter–Hilbert spectral analyses characterized circadian and multiday cycles in brain and wearable recordings. Circular statistics assessed electrographic seizure timing and cycles in physiology. Results Ten subjects met inclusion criteria. The mean recording duration was 232 days. Seven subjects had reliable electroencephalographic seizure detections (mean = 76 seizures). Multiday cycles were present in all wearable device signals across all subjects. Seizure timing was phase locked to multiday cycles in five (temperature), four (heart rate, phasic electrodermal activity), and three (accelerometry, heart rate variability, tonic electrodermal activity) subjects. Notably, after regression of behavioral covariates from heart rate, six of seven subjects had seizure phase locking to the residual heart rate signal. Significance Seizure timing is associated with daily and multiday cycles in multiple physiological processes. Chronic multimodal wearable device recordings can situate rare paroxysmal events, like seizures, within a broader chronobiology context of the individual. Wearable devices may advance the understanding of factors that influence seizure risk and enable personalized time‐varying approaches to epilepsy care.
Towards network-guided neuromodulation for epilepsy
Piper, Rory J. , Carmichael, David W. , Litt, Brian , Tisdall, Martin , Tisdall, Martin M , Richardson, Robert Mark , Worrell, Gregory A. , Baldeweg, Torsten , Denison, Timothy

Mayo Clinic

Brain | June 30, 2022 | Volume: 145 | Issue: 10 | Pages: 3347-3362

10.1093/brain/awac234 | PMID 35771657 Get It

Abstract Epilepsy is well-recognized as a disorder of brain networks. There is a growing body of research to identify critical nodes within dynamic epileptic networks with the aim to target therapies that halt the onset and propagation of seizures. In parallel, intracranial neuromodulation, including deep brain stimulation and responsive neurostimulation, are well-established and expanding as therapies to reduce seizures in adults with focal-onset epilepsy; and there is emerging evidence for their efficacy in children and generalized-onset seizure disorders. The convergence of these advancing fields is driving an era of ‘network-guided neuromodulation’ for epilepsy. In this review, we distil the current literature on network mechanisms underlying neurostimulation for epilepsy. We discuss the modulation of key ‘propagation points’ in the epileptogenic network, focusing primarily on thalamic nuclei targeted in current clinical practice. These include (i) the anterior nucleus of thalamus, now a clinically approved and targeted site for open loop stimulation, and increasingly targeted for responsive neurostimulation; and (ii) the centromedian nucleus of the thalamus, a target for both deep brain stimulation and responsive neurostimulation in generalized-onset epilepsies. We discuss briefly the networks associated with other emerging neuromodulation targets, such as the pulvinar of the thalamus, piriform cortex, septal area, subthalamic nucleus, cerebellum and others. We report synergistic findings garnered from multiple modalities of investigation that have revealed structural and functional networks associated with these propagation points — including scalp and invasive EEG, and diffusion and functional MRI. We also report on intracranial recordings from implanted devices which provide us data on the dynamic networks we are aiming to modulate. Finally, we review the continuing evolution of network-guided neuromodulation for epilepsy to accelerate progress towards two translational goals: (i) to use pre-surgical network analyses to determine patient candidacy for neurostimulation for epilepsy by providing network biomarkers that predict efficacy; and (ii) to deliver precise, personalized and effective antiepileptic stimulation to prevent and arrest seizure propagation through mapping and modulation of each patients’ individual epileptogenic networks.
Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous EEG: Generalizable cross‐patient models
Attia, Tal Pal , Viana, Pedro F. , Nasseri, Mona , Duun‐Henriksen, Jonas , Biondi, Andrea , Winston, Joel S. , Martins, Isabel Pavão , Nurse, Ewan S. , Dümpelmann, Matthias , Worrell, Gregory A. , Schulze‐Bonhage, Andreas , Brinkmann, Benjamin H. , Richardson, Mark P. , Pal Attia, Tal , Pavão Martins, Isabel , Freestone, Dean R , Brinkmann, Benjamin H , Richardson, Mark P , Nurse, Ewan , Schulze-Bonhage, Andreas , Dümpelmann, Matthias , Worrell, Gregory A , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Viana, Pedro F , Freestone, Dean R. , Kjaer, Troels W

Mayo Clinic

Epilepsia | April 20, 2022 | Volume: 64 | Issue: S4 | Pages: No page available

10.1111/epi.17265 | PMID 35441703 Get It

Abstract This study describes a generalized cross‐patient seizure‐forecasting approach using recurrent neural networks with ultra‐long‐term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short‐term memory (LSTM) deep‐learning classifiers. Electrographic seizures were identified by a board‐certified epileptologist. One‐minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise‐added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo‐prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave‐one‐patient‐out cross‐validation method, and the area under the receiver‐operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave‐one‐signal‐out method with repeated training and testing for each classifier. Cross‐patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution ( p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross‐patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two‐channel ultra‐long‐term sqEEG.
Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous electroencephalography: Individualized intrapatient models
Viana, Pedro F. , Attia, Tal Pal , Duun‐Henriksen, Jonas , Biondi, Andrea , Winston, Joel S. , Martins, Isabel Pavão , Nurse, Ewan S. , Dümpelmann, Matthias , Schulze‐Bonhage, Andreas , Richardson, Mark P. , Brinkmann, Benjamin H. , Pal Attia, Tal , Nasseri, Mona , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Pavão Martins, Isabel , Nurse, Ewan , Dümpelmann, Matthias , Schulze-Bonhage, Andreas , Freestone, Dean R , Kjaer, Troels W , Richardson, Mark P , Brinkmann, Benjamin H , Viana, Pedro F , Freestone, Dean R.

Mayo Clinic

Epilepsia | April 8, 2022 | Volume: 64 | Issue: S4 | Pages: No page available

10.1111/epi.17252 | PMID 35395101 Get It

Abstract Objective One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient‐specific seizure forecasting is possible using remote, minimally invasive ultra‐long‐term subcutaneous EEG. Methods We analyzed a two‐center cohort of ultra‐long‐term subcutaneous EEG recordings, including six patients with drug‐resistant focal epilepsy monitored for 46–230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject‐specific long short‐term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation. Results Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65–.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient‐specific circadian patterns of seizure occurrence. Significance This study demonstrates proof‐of‐principle for the possibility of subject‐specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra‐long‐term at‐home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.
A systems‐level analysis highlights microglial activation as a modifying factor in common epilepsies
Altmann, André , Ryten, Mina , Nunzio, Martina Di , Ravizza, Teresa , Reynolds, Regina H. , Somani, Alyma, Bacigaluppi, Marco , Iori, Valentina , Sapia, Rossella Di , Cerovic, Milica , Palma, Eleonora , Ruffolo, Gabriele , Botía, Juan A. , Absil, Julie , Alhusaini, Saud , Alvim, Marina K. M. , Auvinen, Pia, Bartolini, Emanuele , Bender, Benjamin , Bergo, Felipe P. G. , Bernardes, Tauana, Bernasconi, Andrea , Bernasconi, Neda , Bernhardt, Boris C. , Blackmon, Karen , Braga, Bárbara , Caligiuri, Maria Eugenia , Calvo, Anna, Carr, Sarah J. A. , Cavalleri, Gianpiero L. , Chen, Jian , Chen, Shuai , Cherubini, Andrea , Concha, Luis , David, Philippe, Delanty, Norman, Depondt, Chantal, Doherty, Colin P. , Domín, Martin , Foley, Sonya , França, Wendy, Gambardella, Antonio , Guerrini, Renzo , Hamandi, Khalid , Hibar, Derrek P., Isaev, Dmitry , Jahanshad, Neda , Kälviäinen, Reetta , Keller, Simon S. , Kotikalapudi, Raviteja , Kwan, Patrick , Langner, Sönke , Lenge, Matteo , Martin, Pascal , Meletti, Stefano , Morita‐Sherman, Marcia , Pariente, José C. , Richardson, Mark P. , Rummel, Christian , Saavalainen, Taavi, Semmelroch, Mira , Striano, Pasquale, Thesen, Thomas , Thomas, Rhys H. , Tondelli, Manuela , Vaudano, Anna Elisabetta , Vivash, Lucy , Podewils, Felix von , Wagner, Jan , Weber, Bernd , Wiest, Roland , Yasuda, Clarissa Lin , Zhang, Junsong , Group, ENIGMA‐Epilepsy Working, Leu, Costin , Avberšek, Andreja , Whelan, Christopher D. , Thompson, Paul M. , McDonald, Carrie R. , Di Sapia, Rossella , Bender, Benjamin , Severino, Mariasavina , Thom, Maria , Yasuda, Clarissa L , Doherty, Colin P , Cavalleri, Gianpiero L , Weber, Bernd , Thompson, Paul M , Richardson, Mark P , Guerrini, Renzo , Thomas, Rhys H , Leu, Costin , Tolomeo, Daniele , Micotti, Edoardo , Bargalló, Núria , Carlson, Chad , Cendes, Fernando , Devinsky, Orrin , Focke, Niels K. , Jackson, Graeme D. , Kochunov, Peter V , Kowalczyk, Magdalena A. , Kuzniecky, Ruben , Labate, Angelo , Liu, Min , Mascalchi, Mario , Morita, Márcia Elisabete , O’Brien, Terence J. , Rodríguez‐Cruces, Raúl , Tortora, Domenico , Zhang, Guohao , Group, ENIGMA‐Epilepsy Working, Vezzani, Annamaria , Sisodiya, Sanjay

Mayo Clinic

Neuropathology and Applied Neurobiology | August 13, 2021 | Volume: 48 | Issue: 1 | Pages: No page available

10.1111/nan.12758 | PMID 34388852 Get It

Abstract Aims The causes of distinct patterns of reduced cortical thickness in the common human epilepsies, detectable on neuroimaging and with important clinical consequences, are unknown. We investigated the underlying mechanisms of cortical thinning using a systems‐level analysis. Methods Imaging‐based cortical structural maps from a large‐scale epilepsy neuroimaging study were overlaid with highly spatially resolved human brain gene expression data from the Allen Human Brain Atlas. Cell‐type deconvolution, differential expression analysis and cell‐type enrichment analyses were used to identify differences in cell‐type distribution. These differences were followed up in post‐mortem brain tissue from humans with epilepsy using Iba1 immunolabelling. Furthermore, to investigate a causal effect in cortical thinning, cell‐type‐specific depletion was used in a murine model of acquired epilepsy. Results We identified elevated fractions of microglia and endothelial cells in regions of reduced cortical thickness. Differentially expressed genes showed enrichment for microglial markers and, in particular, activated microglial states. Analysis of post‐mortem brain tissue from humans with epilepsy confirmed excess activated microglia. In the murine model, transient depletion of activated microglia during the early phase of the disease development prevented cortical thinning and neuronal cell loss in the temporal cortex. Although the development of chronic seizures was unaffected, the epileptic mice with early depletion of activated microglia did not develop deficits in a non‐spatial memory test seen in epileptic mice not depleted of microglia. Conclusions These convergent data strongly implicate activated microglia in cortical thinning, representing a new dimension for concern and disease modification in the epilepsies, potentially distinct from seizure control.
Signal quality and power spectrum analysis of remote ultra long‐term subcutaneous EEG
Viana, Pedro F. , Remvig, Line Sofie, Duun‐Henriksen, Jonas , Glasstetter, Martin , Dümpelmann, Matthias , Nurse, Ewan S. , Martins, Isabel Pavão , Schulze‐Bonhage, Andreas , Brinkmann, Benjamin H. , Richardson, Mark P. , Brinkmann, Benjamin H , Kjaer, Troels W , Nurse, Ewan , Schulze-Bonhage, Andreas , Dümpelmann, Matthias , Richardson, Mark P , Duun-Henriksen, Jonas , Pavão Martins, Isabel , Viana, Pedro F , Freestone, Dean R.

Mayo Clinic

Epilepsia | July 12, 2021 | Volume: 62 | Issue: 8 | Pages: 1820-1828

10.1111/epi.16969 | PMID 34250608 Get It

Abstract Objective Ultra long‐term subcutaneous electroencephalography (sqEEG) monitoring is a new modality with great potential for both health and disease, including epileptic seizure detection and forecasting. However, little is known about the long‐term quality and consistency of the sqEEG signal, which is the objective of this study. Methods The largest multicenter cohort of sqEEG was analyzed, including 14 patients with epilepsy and 12 healthy subjects, implanted with a sqEEG device (24/7 EEG ™ SubQ), and recorded from 23 to 230 days (median 42 days), with a median data capture rate of 75% (17.9 hours/day). Median power spectral density plots of each subject were examined for physiological peaks, including at diurnal and nocturnal periods. Long‐term temporal trends in signal impedance and power spectral features were investigated with subject‐specific linear regression models and group‐level linear mixed‐effects models. Results sqEEG spectrograms showed an approximate 1/f power distribution. Diurnal peaks in the alpha range (8‐13Hz) and nocturnal peaks in the sigma range (12‐16Hz) were seen in the majority of subjects. Signal impedances remained low, and frequency band powers were highly stable throughout the recording periods. Significance The spectral characteristics of minimally invasive, ultra long‐term sqEEG are similar to scalp EEG, whereas the signal is highly stationary. Our findings reinforce the suitability of this system for chronic implantation on diverse clinical applications, from seizure detection and forecasting to brain‐computer interfaces.