Abstract Aims To develop quality indicators (QIs) that may be used to evaluate the quality of care and outcomes for adults with atrial fibrillation (AF). Methods and results We followed the ESC methodology for QI development. This methodology involved (i) the identification of the domains of AF care for the diagnosis and management of AF (by a group of experts including members of the ESC Clinical Practice Guidelines Task Force for AF); (ii) the construction of candidate QIs (including a systematic review of the literature); and (iii) the selection of the final set of QIs (using a modified Delphi method). Six domains of care for the diagnosis and management of AF were identified: (i) Patient assessment (baseline and follow-up), (ii) Anticoagulation therapy, (iii) Rate control strategy, (iv) Rhythm control strategy, (v) Risk factor management, and (vi) Outcomes measures, including patient-reported outcome measures (PROMs). In total, 17 main and 17 secondary QIs, which covered all six domains of care for the diagnosis and management of AF, were selected. The outcome domain included measures on the consequences and treatment of AF, as well as PROMs. Conclusion This document defines six domains of AF care (patient assessment, anticoagulation, rate control, rhythm control, risk factor management, and outcomes), and provides 17 main and 17 secondary QIs for the diagnosis and management of AF. It is anticipated that implementation of these QIs will improve the quality of AF care.
2018: Year in Review and Message from the Editors to Our Reviewers
EHRA Expert Consensus Statement on the management of cardiovascular implantable electronic devices in patients nearing end of life or requesting withdrawal of therapy
Abstract The purpose of this Consensus Statement is to focus on implantable cardioverter-defibrillator (ICD) deactivation in patients with irreversible or terminal illness. This statement summarizes the opinions of the Task Force members, convened by the European Heart Rhythm Association (EHRA) and the Heart Rhythm Society (HRS), based on ethical and legal principles, as well as their own clinical, scientific, and technical experience. It is directed to all healthcare professionals who treat patients with implanted ICDs, nearing end of life, in order to improve the patient dying process. This statement is not intended to recommend or promote device deactivation. Rather, the ultimate judgement regarding this procedure must be made by the patient (or in special conditions by his/her legal representative) after careful communication about the deactivation's consequences, respecting his/her autonomy and clarifying that he/she has a legal and ethical right to refuse it. Obviously, the physician asked to deactivate the ICD and the industry representative asked to assist can conscientiously object to and refuse to perform device deactivation.