Citations

Clear

48 citation(s) found for "Kawashima, Akira".

Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI
Riederer, Stephen J. , Borisch, Eric A. , Du, Qingshuo, Froemming, Adam T. , Hulshizer, Thomas C., McGee, Kiaran P. , Robb, Fraser , Rossman, Phillip J. , Takahashi, Naoki , Riederer, Stephen J , Takahashi, Naoki , Kawashima, Akira

Mayo Clinic

Magnetic Resonance in Medicine | September 26, 2024 | Volume: 93 | Issue: 2 | Pages: 850-863

10.1002/mrm.30289 | PMID 39322985 Get It

AbstractPurposeTo study if adaptive image receive (AIR) receiver coil elements can be configured into a 2D array with high (>45% by diameter) element‐to‐element overlap, allowing improved SNR at depth (0.7–1.5× element diameter) versus conventional (20%) overlap.MethodsAn anterior array composed of twenty 10‐cm diameter elements with 45% overlap arranged into a 4 × 5 grid and a similar 3 × 7 twenty‐one‐element posterior array were constructed. SNR and g‐factor were measured in a pelvic phantom using the new high‐density (HD) arrays (41 total elements) and compared to vendor AIR‐based arrays (30 total elements) with conventional overlap. T2‐weighted fast‐spin‐echo (T2SE) images acquired using both arrays were compared in 20 subjects. SNR was estimated in vivo. Results were compared blindly by three uroradiologists using a five‐point scale. Images using the HD arrays were also compared to a set of images acquired over a range of acceleration factors (R = 2.0, 2.5, 3.0) with the conventional arrays.ResultsSNR within the phantom was on average 15% higher for R = 1.0, 1.5, and 2.0 using the HD arrays. Across the 20 subjects SNR within the prostate was 11% higher and assessed radiologically as significantly higher (p < 0.001) for the HD versus conventional arrays. At all acceleration factors the new HD arrays outperformed the conventional arrays (p ≤ 0.01), allowing increased R for similar SNR.ConclusionAIR elements can be configured into 2D arrays with high (45%) element‐to‐element overlap, consistently providing increased SNR at depth versus arrays with conventional (20%) overlap. The SNR improvement allows increased acceleration in T2SE prostate MRI.
Fully Automated Deep Learning Model to Detect Clinically Significant Prostate Cancer at MRI
Cai, Jason , Nakai, Hirotsugu , Kuanar, Shiba , Froemming, Adam T. , Bolan, Candice W. , Kawashima, Akira , Takahashi, Hiroaki , Mynderse, Lance A. , Humphreys, Mitchell R. , Korfiatis, Panagiotis , Bratt, Alex , Takahashi, Naoki , Dora, Chandler D , Humphreys, Mitchell R , Korffiatis, Panagiotis , Rouzrokh, Pouria , Bratt, Alex , Conte, Gian Marco , Erickson, Bradley J , Takahashi, Naoki , Kawashima, Akira , Takahashi, Hiroaki , Dora, Chandler , Rouzrokh, Pouria , Erickson, Bradley J.

Mayo Clinic

Radiology | August 6, 2024 | Volume: 312 | Issue: 2 | Pages: No page available

10.1148/radiol.232635 | PMID 39105640 Get It

The performance of a deep learning model was not different from that of radiologists in the detection of clinically significant prostate cancer at MRI, and gradient-weighted class activation maps localized the tumor.
MRI in Adult Patients with Active and Inactive Implanted MR-conditional, MR-nonconditional, and Other Devices
Harwood, Matthew , Fahrenholtz, Samuel J. , Wellnitz, Clinton V., Kawashima, Akira , Panda, Anshuman , Kawashima, Akira , Harwood, Matthew

Mayo Clinic

RadioGraphics | February 29, 2024 | Volume: 44 | Issue: 3 | Pages: No page available

10.1148/rg.230102 | PMID 38421911 Get It

Urinary Bladder Masses, Rare Subtypes, and Masslike Lesions: Radiologic-Pathologic Correlation
Hoegger, Mark J. , Strnad, Benjamin S. , Ballard, David H. , Siegel, Cary , Shetty, Anup S. , Weimholt, R. Cody, Yano, Motoyo , Stanton, Melissa, Mellnick, Vincent M. , Siegel, Cary Lynn , Stanton, Melissa L, Zulfiqar, Maria , Mellnick, Vincent , Shetty, Anup , Ballard, David H , Kawashima, Akira , Zulfiqar, Maria

Mayo Clinic

RadioGraphics | December 9, 2022 | Volume: 43 | Issue: 1 | Pages: No page available

10.1148/rg.220034 | PMID 36490210 Get It

Imaging of the Bulbourethral (Cowper) Gland: Abnormalities and Differential Diagnosis
Takahashi, Hiroaki , Potretzke, Theodora A. , Kawashima, Akira , Cheville, John C. , Masuoka, Sota , Kawashima, Akira , Potretzke, Theodora , Takahashi, Hiroaki , Kim, Bohyun

Mayo Clinic

RadioGraphics | September 23, 2022 | Volume: 42 | Issue: 7 | Pages: 2037-2053

10.1148/rg.220099 | PMID 36149823 Get It

Model‐based image reconstruction with wavelet sparsity regularization for through‐plane resolution restoration in T2‐weighted spin‐echo prostate MRI
Borisch, Eric A. , Froemming, Adam T. , Grimm, Roger C., Trzasko, Joshua D. , Riederer, Stephen J. , Riederer, Stephen J , Kawashima, Akira

Mayo Clinic

Magnetic Resonance in Medicine | September 12, 2022 | Volume: 89 | Issue: 1 | Pages: 454-468

10.1002/mrm.29447 | PMID 36093998 Get It

PurposeThe purpose is to develop a model‐based image‐reconstruction method using wavelet sparsity regularization for maintaining restoration of through‐plane resolution but with improved retention of SNR versus linear reconstruction using Tikhonov (TK) regularization in high through‐plane resolution (1 mm) T2‐weighted spin‐echo (T2SE) images of the prostate.MethodsA wavelet sparsity (WS)–regularized image reconstruction was developed that takes as input a set of ≈80 overlapped 3‐mm‐thick slices acquired using a T2SE multislice scan and typically 30 coil elements. After testing in contrast and resolution phantoms and calibration in 6 subjects, the WS reconstruction was evaluated in 16 consecutive prostate T2SE MRI exams. Results reconstructed with nominal 1‐mm thickness were compared with those from the TK reconstruction with the same raw data. Results were evaluated radiologically. The ratio of magnitude of prostate signal to periprostatic muscle signal was used to assess the presence of noise reduction. Technical performance was also compared with a commercial 3D‐T2SE sequence.ResultsThe new WS reconstruction was assessed as superior statistically to TK for overall SNR, contrast, and multiple evaluation criteria related to sharpness while retaining the high (1 mm) through‐plane resolution. Wavelet sparsity tended to provide improved overall diagnostic quality versus TK, but not significantly so. In all 16 studies, the prostate‐to‐muscle signal ratio increased.ConclusionsModel‐based WS‐regularized reconstruction consistently provides improved SNR in high (1 mm) through‐plane resolution images of prostate T2SE MRI versus linear reconstruction using TK regularization.
Long-Term Risk of Clinical Progression Utilizing Magnetic Resonance Imaging Findings of Locally Recurrent Prostate Cancer in Patients with Biochemical Recurrence following Radical Prostatectomy
Tanaka, Takashi , Kawashima, Akira, Rangel, Laureano J., Schulte, Phillip J., Froemming, Adam T., King, Bernard F., Mynderse, Lance A., Karnes, R. Jeffrey, Tanaka, Takashi , Kawashima, Akira, Rangel, Laureano J., Schulte, Phillip J., Froemming, Adam T., King, Bernard F., Mynderse, Lance A., Karnes, R. Jeffrey

Mayo Clinic

Journal of Urology | January 4, 2022 | Volume: 207 | Issue: 5 | Pages: 1038-1047

10.1097/ju.0000000000002421 | PMID 34981952 Get It

MRI Evaluation of Patients Before and After Interventions for Benign Prostatic Hyperplasia: An Update
Diaz, Teresa A., Benson, Benjamin , Clinkenbeard, Alexander, Long, Jeremiah R. , Yano, Motoyo , Kawashima, Akira

Mayo Clinic

American Journal of Roentgenology | July 14, 2021 | Volume: 218 | Issue: 1 | Pages: 88-99

10.2214/ajr.21.26278 | PMID 34259037 Get It