B-150 Chromatographic Separation and Quantitation of Human Insulin and Lispro Analog in Serum Using Liquid Chromatography High-Resolution Mass Spectrometry
Campbell, M, Moehnke, Kayla , Grebe, S K, Campbell, M, Maus, Anthony

Mayo Clinic

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.510 Get It

Abstract Background Factitious hypoglycemia, a deliberate attempt to induce low blood glucose levels occurring secondary to the surreptitious administration of exogenous insulin, can be difficult to diagnose due to a variety of factors including the increased use of synthetic insulin analogs in clinical practice. Traditional insulin immunoassays demonstrate variable cross-reactivity with commonly prescribed insulin analogues and their metabolites, making it difficult to measure specific analogs. The development of liquid chromatography high resolution accurate mass (LC-HRAM)-mass spectrometry (MS) assays has largely circumvented the limitations of traditional immunoassays for detection and quantitation of insulin analogs. Analytical challenges remain, however, specifically in differentiating lispro, an isomeric human insulin analog formed by the transposition of proline and lysine near the C-terminal end of the B chain, from human insulin in patient samples due to the equivalent mass-to-charge ratios of their precursor ions. Methods Immunoaffinity purification of insulin from calibrators and quality control material prepared by spiking insulin-depleted serum with pharmaceutical insulin preparations, as well as patient samples, was performed using tips coupled with anti-insulin monoclonal antibody. An automated liquid handler was programmed to perform aspiration and dispense cycles. Eluate from the purification protocol was submitted for analysis using a TLX-2 multiplex LC system paired with a Thermo Scientific Q Exactive Plus mass spectrometer. Various HPLC column chemistries were evaluated, a column passivation procedure was established, and column heater temperature was optimized to identify a combination of parameters yielding the best chromatographic separation of human insulin and lispro. Additionally, parallel reaction monitoring (PRM) targeted tandem mass spectrometry (MS/MS) analysis was utilized in combination with the full scan data to increase specificity through the monitoring of fragment ions produced from human insulin and each insulin analog. Results We found that a 1000 Å Diphenyl, 2.7 µm, 2.1 x 100 mm analytical column in a column heater maintained at a temperature of 80°C allowed for human insulin and lispro to be differentiated as two chromatographically separated extracted ion chromatographic peaks (XICs) and quantified down to 2.5 mcIU/mL with near-baseline separation. Before use, the column required passivation with a high protein buffer (0.05% bovine serum albumin in 20% acetonitrile [ACN] + 0.2% acetic acid) followed by increasingly organic buffers (20% ACN + 0.2% acetic acid and 50% ACN + 0.2% acetic acid). MS/MS was used to confirm the presence of analogs detected. Conclusions The LC-HRAM-MS method described here, coupled with optimized column chemistry, column passivation, and proper column temperature control allows for chromatographic separation of human insulin and lispro. Incorporating a PRM scan into the mass spectrometry full scan method provides confirmation of the insulin detected in the XICs. The results obtained from preliminary studies suggest this method is appropriate for use to facilitate the clinical investigation of suspected factitious hypoglycemia with the ability to differentiate isomeric compounds, such as human insulin and lispro.
B-151 Development and Validation of Plasma Catecholamines by Mass Spectrometry
Grebe, S K, Kemp, J, Taylor, R, Maus, Anthony

Mayo Clinic

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.511 Get It

Abstract Background Our established method for measuring plasma catecholamines utilized a Shimadzu HPLC coupled to an ESA Coulochem III electrochemical detector. Chromatographic run times were long, resulting in slow turnaround times. Instrument maintenance was labor intensive, and the assay was prone to interferences. To overcome these limitations, we changed the method to liquid chromatography-tandem mass spectrometry (LC-MS/MS) measurements. Methods After the addition of a labeled internal standard for each analyte, samples are loaded onto 50 mg of activated alumina at pH 8.6, utilizing a Tris-HCl, sodium carbonate and EDTA buffer. After incubation the alumina is then washed with 50% acetonitrile followed by water. Elution off the alumina is performed with 2% acetic acid. Derivatization is then performed on the eluate utilizing acetaldehyde and a cyanoborohydride buffer. Following derivatization, the samples are analyzed for epinephrine, norepinephrine, and dopamine by LC-MS/MS using a Sciex 7500 coupled to a ThermoFisher Scientific TLX-4 equipped with Vanquish pumps. Chromatographic separation was obtained using a Phenomenex Kinetex 2.6 um BiPhenyl 50x3 mm analytical column. Results Runtimes were significantly shorter than with the previous method, and no interferences were observed. Assay validation consisted of: intra/inter assay precision, accuracy, recovery, linearity, carryover, limit of detection (LOD), and interferences. Three levels were assessed for intra assay precision and each of the analytes monitored yielded %CVs of less than 6%. Four levels were assessed for inter assay precision and each of the analytes monitored yielded %CVs of less than 10%. When using linear regression analysis to compare results with the previous clinical assay, the slope, y-intercept and R2 were the following; dopamine: 1.06, 2.74, 0.978; epinephrine: 0.905, 2.20, 0.989; norepinephrine: 0.919, 9.75, 0.953. Spike and recovery from five samples yielded a mean average recovery of 93.4% for dopamine, 100% for epinephrine and 98.1% for norepinephrine. For linearity 4 samples were diluted and the mean % difference from expected was -1.66% for dopamine, -0.25% for epinephrine and 1.78% for norepinephrine. Blanks were injected following the high standard and carryover was negligible. LOD was determined by running a low sample pool along with a blank over 20 assays. The LOD was determined to be less than the LLOQ. Sixty-two common drugs/vitamins along with varying levels of hemolysis, lipemia, and bilirubin were also tested to ensure no interferences were seen. Conclusions The LC-MS/MS method exceeded the performance of the historical Shimdazu HPLC system with ESA Coluochem III electrochemical detector method. We anticipate that the better analytical performance will improve the testing quality of our patients.
Serum Steroid Profiling in the Diagnosis of Adrenocortical Carcinoma: A Prospective Cohort Study
Yu, Kai , Athimulam, Shobana , Saini, Jasmine , Kaur, Ravinder Jeet , Xue, Qingping , McKenzie, Travis J. , Grebe, Stefan K., Grebe, Stefan, Bancos, Irina , Saini, Jasmine , Singh, Ravinder J. , Bancos, Irina

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | September 5, 2024 | Volume: 110 | Issue: 4 | Pages: 1177-1186

10.1210/clinem/dgae604 | PMID 39231247 Get It

Abstract Context Guidelines suggest performing urine steroid profiling in patients with indeterminate adrenal tumors to make a noninvasive diagnosis of adrenocortical carcinoma (ACC). However, urine steroid profiling is not widely available. Objective To determine the accuracy of clinically available serum 11-deoxycortisol, 17OH-progesterone, and 17OH-pregnenolone in diagnosing ACC. Methods We conducted a prospective single-center cohort study of patients with adrenal masses evaluated between 2015 and 2023. Serum was analyzed by liquid chromatography–mass spectrometry for 17OH-pregnenolone, 17OH-progesterone, and 11-deoxycortisol. Reference standard for adrenal mass included histopathology, imaging characteristics, imaging follow up of 2 years, or clinical follow up of 5 years. Localized Generalized Matrix Learning Vector Quantization analysis was used to develop serum steroid score and assessed with area under receiver operating curve. Results Of 263 patients with adrenal masses, 44 (16.7%) were diagnosed with ACC, 161 (61%) with adrenocortical adenomas (ACAs), 27 (10%) with other adrenal malignancies, and 31 (12%) with other. Hounsfield unit ≥ 20 was demonstrated in all ACCs, in all but 1 other adrenal malignancy, and in 58 (31%) ACAs. All 3 steroids were higher in patients with ACCs vs non-ACCs, including when comparing ACCs with functioning ACAs, and with ACAs with Hounsfield unit ≥ 20 (P < .0001 for all). Localized Generalized Matrix Learning Vector Quantization analysis yielded a serum steroid score that discriminated between ACC and non-ACC groups with a mean threshold fixed area under receiver operating curve of 0.823. Conclusion We showed that measurements of 11-deoxycortisol, 17OH-progesterone, and 17OH-pregnenolone could be valuable in diagnosing ACC. After appropriate validation, serum steroid score could be integrated in clinical practice.
Steroid Profiling and Circadian Cortisol Secretion in Patients With Mild Autonomous Cortisol Secretion: A Cross-sectional Study
Saini, Jasmine , Singh, Sumitabh , Ebbehøj, Andreas , Zhang, Catherine D , Nathani, Rohit, Fell, Vanessa , Atkinson, Elizabeth J. , Achenbach, Sara J., Rivard, Ann L, Grebe, Stefan K. , Atkinson, Elizabeth , Achenbach, Sara, Rivard, Ann, Grebe, Stefan K G , Bancos, Irina , Saini, Jasmine , Ebbehøj, Andreas Ladefoged , Nathani, Rohit , Singh, Ravinder , Bancos, Irina

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | July 9, 2024 | Volume: 110 | Issue: 2 | Pages: 542-553

10.1210/clinem/dgae468 | PMID 38981002 Get It

Abstract Context Mild autonomous cortisol secretion (MACS) is diagnosed based on postdexamethasone cortisol >1.8 µg/dL. Scarce evidence exists on steroid circadian secretion and steroid metabolome in MACS. Objective To characterize 24-hour (h) urine steroid metabolome in patients with MACS and determine circadian differences in urine steroid profiling and cortisol concentrations in patients with MACS vs referent subjects. Methods Cross-sectional study, 2018-2023, at a referral center. Patients with MACS and age-, sex-, body mass index–, and menopausal status–matched referent subjects were included. Urine was collected over a 24 hour period as separate daytime and nighttime collections. High-resolution mass spectrometry assay was used to measure 25 steroids. A subgroup of patients and referent subjects was admitted for serum measurements of free and total cortisol every 2 hours. Outcomes were steroids, steroid sums, and ratios. Results Patients with MACS (n = 72) had lower µg/24 hour median androgens (2084 vs 3283, P < .001), higher glucocorticoids (15 754 vs 12936, P < .001), and higher glucocorticoid/androgen ratio (8.7 vs 3.9, P < .001) than referent subjects. Patients also had lower steroid day/night ratios than referent subjects, reflecting a higher relative nocturnal steroid production in MACS. In a subgroup of 12 patients with MACS and 10 referent subjects, the 24-hour areas under the curve for total and free serum cortisol were similar. However, evening mean total (5.3 vs 4.0 µg/dL, P = .056) and free (0.2 vs 0.1 µg/dL, P = .035) cortisol was higher in patients vs referent subjects. Conclusion Patients with MACS demonstrate an abnormal urine steroid metabolome, with a high glucocorticoid to androgen ratio, and a higher nocturnal steroid production.
Commentary on Severe Hypokalaemia Associated with Paralysis after a Large Carbohydrate Intake following Exercise
Grebe, Stefan K. , Grebe, Stefan K G

Mayo Clinic

Clinical Chemistry | April 3, 2024 | Volume: 70 | Issue: 4 | Pages: 587-587

10.1093/clinchem/hvad229 | PMID 38565210 Get It

Identification, Measurement, and Assessment of the Clinical Utility of Human Pancreatic Polypeptide by Liquid Chromatography–Tandem Mass Spectrometry
Maus, Anthony , Fatica, Erica M. , Larson, Bethany J., Grebe, Stefan K. , Maus, Anthony D , Taylor, Robert, Larson, Bethany J., Algeciras‐Schimnich, Alicia , Singh, Ravinder J.

Mayo Clinic

Journal of Proteome Research | March 7, 2023 | Volume: 22 | Issue: 4 | Pages: 1322-1330

10.1021/acs.jproteome.2c00829 | PMID 36880754 Get It

Machine Learning-Based Fragment Selection Improves the Performance of Qualitative PRM Assays
Vanderboom, Patrick M. , Maus, Anthony , Kemp, Jennifer, Gurtner, Kari M., Grebe, Stefan K. , Pandey, Akhilesh , Dasari, Surendra , Renuse, Santosh , Maus, Anthony D , Madugundu, Anil K. , Kemp, Jennifer V, Pandey, Akhilesh , Singh, Ravinder J.

Mayo Clinic

Journal of Proteome Research | July 18, 2022 | Volume: 21 | Issue: 8 | Pages: 2045-2054

10.1021/acs.jproteome.2c00156 | PMID 35849720 Get It

Targeted Detection of SARS-CoV-2 Nucleocapsid Sequence Variants by Mass Spectrometric Analysis of Tryptic Peptides
Maus, Anthony , Renuse, Santosh , Kemp, Jennifer, Madugundu, Anil K. , Vanderboom, Patrick M. , Blommel, Joseph H. , Jerde, Calvin R. , Dasari, Surendra , Kipp, Benjamin R. , Grebe, Stefan K. , Pandey, Akhilesh , Blommel, Joseph, Jerde, Calvin, Pandey, Akhilesh , Pandey, Akhilesh , Maus, Anthony D , Singh, Ravinder J.

Mayo Clinic

Journal of Proteome Research | November 15, 2021 | Volume: 21 | Issue: 1 | Pages: 142-150

10.1021/acs.jproteome.1c00613 | PMID 34779632 Get It

Interpretation of Abnormal Dexamethasone Suppression Test is Enhanced With Use of Synchronous Free Cortisol Assessment
Genere, Natalia , Kaur, Ravinder Jeet , Athimulam, Shobana , Thomas, Melinda, Nippoldt, Todd B., Norman, Molly Van, Grebe, Stefan K., Thomas, Melinda A, Nippoldt, Todd, Van Norman, Molly, Grebe, Stefan, Bancos, Irina , Singh, Ravinder J. , Bancos, Irina

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | October 19, 2021 | Volume: 107 | Issue: 3 | Pages: e1221-e1230

10.1210/clinem/dgab724 | PMID 34648626 Get It

Abstract Context Interpretation of dexamethasone suppression test (DST) may be influenced by dexamethasone absorption and metabolism and by the altered cortisol binding. Objective We aimed to determine the normal ranges of free cortisol during DST in participants without adrenal disorders and to identify the population of patients where post-DST free cortisol measurements add value to the diagnostic workup. Design and Setting Cross-sectional study conducted in a tertiary medical center. Participants Adult volunteers without adrenal disorders (n = 168; 47 women on oral contraceptive therapy [OCP], 66 women not on OCP, 55 men) and patients undergoing evaluation for hypercortisolism (n = 196; 16 women on OCP). Measurements Post-DST dexamethasone and free cortisol (mass spectrometry) and total cortisol (immunoassay). Main Outcome Measures Reference range for post-DST free cortisol, diagnostic accuracy of post-DST total cortisol. Results Adequate dexamethasone concentrations (≥0.1 mcg/dL) were seen in 97.6% volunteers and 96.3% patients. Only 25.5% of women volunteers on OCP had abnormal post-DST total cortisol (>1.8 mcg/dL). In volunteers, the upper post-DST free cortisol range was 48 ng/dL in men and women not on OCP, and 79 ng/dL in women on OCP. When compared with post-DST free cortisol, diagnostic accuracy of post-DST total cortisol was 87.3% (95% CI, 81.7-91.7); all false-positive results occurred in patients with post-DST cortisol between 1.8 and 5 mcg/dL. OCP use was the only factor associated with false-positive results (21.1% vs 4.9%, P = 0.02). Conclusions Post-DST free cortisol measurements are valuable in patients with optimal dexamethasone concentrations and post-DST total cortisol between 1.8 and 5 mcg/dL.
Isotopic Distribution Calibration for Mass Spectrometry
Maus, Anthony , Kemp, Jennifer, Hoffmann, Todd J., Ramsay, Steven L., Grebe, Stefan K., Maus, Anthony D , Kemp, Jennifer V, Grebe, Stefan K G

Mayo Clinic

Analytical Chemistry | September 7, 2021 | Volume: 93 | Issue: 37 | Pages: 12532-12540

10.1021/acs.analchem.1c01672 | PMID 34490782 Get It