0789 Mask Magnets May Interact with Pacemakers and Implantable Cardioverter-Defibrillators
Ruoff, Chad , Tashman, Yasemin, Miller, Bernie, Cheema, Kamal, Haley, Caitlin, Petersen, Ann, Lizak, Matthew, Goswami, Umesh , Lizak, Trevor, Krahn, Lois E., Ruoff, Chad M , Miller, Bernie, Houser, Ryan Scott , Cheema, Kamal Preet, Haley, Caitlin C., Petersen, Ann, Goswami, Umesh, Srivathsan, Komandoor

Mayo Clinic

Sleep | May 31, 2022 | Volume: 45 | Issue: Supplement_1 | Pages: A342-A343

10.1093/sleep/zsac079.785 Get It

Abstract Introduction Placing a magnet over a Permanent Pacemaker (PPM) or Implanted Cardioverter-Defibrillator (ICD) may cause the device to pace asynchronously or inhibit tachyarrhythmia detection, respectively, potentially preventing delivery of electrical shocks. Manufacturers for masks used with positive airway pressure devices have started using magnets in place of more traditional headgear clips to connect the headgear to mask. Mask manufactures do not list presence of a PPM/ICD as a contraindication to use of a mask with magnet but do recommend keeping the mask some distance away from PPM/ICD. A published case series describes two patients with magnet response events captured during PPM/ICD interrogation that correlated with nightly use of CPAP. The authors were able to replicate the response by placing the mask with magnet directly over the patient’s pulse generate site. Although we advise all patients with implanted device to avoid use of masks with magnets, select patients refuse to stop using mask with magnets regardless of our policy. We, therefore, started offering these patients referral for PPM/ICD interrogation to evaluate for an interaction between mask with magnet and PPM/ICD as next best alternative. Methods We retrospectively reviewed all patients (n=10) referred for routine PPM/ICD interrogation to test whether the mask with magnet interacted with PPM/ICD when mask on face as during normal use (i.e., simulated normal use) or magnetic area of mask placed directly over the PPM/ICD (i.e., direct contact). Results Although no interaction was detected in any patient (n=10) with simulated normal use (0 %), one interaction was documented with direct contact (10 %). Conclusion Although simulated normal use of masks with magnets did not demonstrate any interactions, it is concerning that one patient (10 % of patients) demonstrated an interaction with direct contact of magnetic area of mask over the PPM/ICD. It is not uncommon for patients to remove a mask during the night while sleeping. This preliminary data along with the published case series calls for further research and increased awareness of this potential interaction for both sleep and cardiac health care providers. Support (If Any) None
Kidney Allograft and Recipient Survival After Heart Transplantation by Induction Type in the United States
Riad, Samy , Alexy, Tamás , Jackson, Scott , Goswami, Umesh , Martin, Cindy M. , Riad, Samy M. , Goswami, Umesh

Mayo Clinic

Transplantation | March 20, 2021 | Volume: 106 | Issue: 3 | Pages: 633-640

10.1097/tp.0000000000003758 | PMID 33741841 Get It

Background. Induction choices for kidney-after-heart transplant recipients are variable. We examined the impact of kidney induction types on kidney graft and patient survival in heart transplant recipients. Methods. We analyzed the Scientific Registry of Transplant Recipient database from inception through the end of 2018 to study kidney and patient outcomes in the United States after heart transplantation. We only included recipients who were discharged on tacrolimus and mycophenolate maintenance. We grouped recipients by induction type into 3 groups: depletional (N = 307), nondepletional (n = 253), and no-induction (steroid only) (n = 57). We studied patients and kidney survival using Cox PH regression, with transplant centers included as a random effect. We adjusted the models for heart induction, recipient and donor age, gender, time between heart and kidney transplant, heart transplant indication, HLA mismatches, payor, live-donor kidney, transplant year, dialysis status, and diabetes mellitus at the time of kidney transplant. Results. The 1-y kidney rejection rates and creatinine levels were similar in all groups. The 1-y rehospitalization rate was higher in the depletional group (51.7%) and nondepletional group (50.7%) than in the no-induction group (39.1%) although this was not statistically significant. There were no differences in recipient or kidney survival by kidney induction type. Live-donor kidney was associated with improved patient (hazard ratio, 0.74; 95% confidence interval, 0.54-1.0; P = 0.05) and kidney survival (hazard ratio, 0.45; 95% confidence interval, 0.24-0.84; P = 0.012]. Conclusions. Type of kidney induction did not influence patient or kidney graft survival in heart transplant recipients. No-induction may be the preferred choice due to the lack of clinical benefits associated with induction use.