ABSTRACT Objective Weight loss is frequently considered a cardinal presenting symptom for patients with Zenker diverticulum (ZD). We hypothesized that weight loss in patients with cricopharyngeal muscle dysfunction (CPMD), with or without diverticula, was associated with the length of symptoms and size of diverticulum. Methods Prospective, multicenter observational study of CPMD patients with and without diverticula reporting unintentional weight loss (+WL) or no weight loss (−WL) prior to enrollment in the Prospective Outcomes of Cricopharyngeal Hypertonicity (POuCH) database. Complications and symptom response using a patient reported outcome measure, the Eating Assessment Tool (EAT‐10), were compared. Results Of 427 patients, 101 (23.6%) were +WL. Median weight loss was 14 pounds (interquartile range [IQR] 10–25). +WL cohort had a mean age of 71.5 (standard deviation [SD] 11.5) vs. 67.9 in −WL (SD 11.6, p = 0.007). Mean preoperative EAT‐10 score was 24.7 in +WL (SD 9.7) and 14.8 in −WL (SD 8.8, p < 0.0001). Higher preoperative weight loss was associated with higher preoperative EAT‐10 ( p < 0.0001, Spearman's ρ = 0.43). Size of diverticulum was associated with WL ( p = 0.003), but weight loss was highest in both large diverticula and CP bars. Duration of symptoms was not associated with weight loss ( p = 0.30). Postoperative complications in +WL and −WL patients were similar ( p = 0.78). Conclusion Unintentional weight loss is common with ZD. Patients with worse dysphagia are more likely to have more weight loss. Weight loss does not increase with the size of the diverticulum or length of symptoms. Surgery has a similar safety profile with greater improvement in dysphagia in patients reporting weight loss. Level of Evidence 3.
Digital biomarkers in cardiovascular medicine: a scientific statement of the ESC Working Group on e-Cardiology, the ESC Working Group on Cardiovascular Pharmacotherapy, the European Heart Rhythm Association (EHRA) of the ESC, the Association for Acute Card
Abstract Cardiovascular disease is the leading cause of morbidity and mortality globally, imposing a substantial patient burden. Digital biomarkers derived from digital health technologies enable quantifiable, near-continuous, real-world capture of pathophysiological signals and are increasingly used across cardiovascular medicine. Their growth is often supported by big data analytics, artificial intelligence and connected sensors within the Internet of Things. This scientific statement systematically reviews digital biomarkers, their clinical utility across the cardiovascular care continuum, and summarizes major methodological and implementation challenges. We searched PubMed/MEDLINE, Embase and Scopus for phase III–IV cardiovascular trials published between 1 January 2019 and 1 August 2024 that collected digital biomarkers. We identified 541 records and included 32 trials (40 reports) enrolling 32 246 participants (44.71% women; mean age 66.2 ± 11.0 years). Heart failure was the most frequent target condition (16 trials, 50%), followed by cardiac implantable electronic devices trials (12 trials, 38%). Digital biomarkers included cardiac rhythm and heart rate, blood pressure, body weight, impedance-based measures, haemodynamic pressures, and physical activity and sleep patterns captured using diverse sensor technologies. Methodological quality was good (modal quality score 5; range 3–7), although most trials were unblinded. Current studies suggest potential clinical utility in selected cardiovascular conditions. Implementation remains challenging because of measurement variability, privacy and regulatory requirements, affordability and reimbursement barriers and inequities in access. Robust validation and outcome- and cost-effectiveness evidence are still needed. Registration number: CRD42024573879.
Consensus Guidelines for Staging and Surveillance Imaging in Cutaneous Squamous Cell Carcinoma
Importance There is no consensus on staging and surveillance imaging for cutaneous squamous cell carcinoma (CSCC). Although imaging has been shown to affect management, broad recommendations from the National Comprehensive Cancer Network have led to variability in clinical practice. Objective To develop multidisciplinary consensus recommendations on the use of staging and surveillance imaging of localized CSCC. Evidence Review A multidisciplinary expert panel across academic and clinical practice settings convened a Delphi consensus, with 3 iterative survey rounds from January to June 2025. Data were analyzed from February 2025 to January 2026. Eligibility defined by at least 1 to 2 CSCC publications during the previous 5 years, involvement in a relevant clinical trial, experience treating at least 3 patients monthly with CSCC, and/or 5 years or longer of clinical practice. Fifty-four experts were invited and 45 (83%) completed all 3 rounds and were included in the final analysis. Structured Delphi surveys evaluated clinical scenarios, imaging modalities, and surveillance strategies for CSCC. Consensus and near-consensus recommendations were generated, defined as 80% or greater and 70% to 79% agreement, respectively. Findings The 45 participants (21 female individuals [47%] and 24 male individuals [53%]; 14 Asian individuals [31%], 1 multiracial individual [2%], and 30 White individuals [67%]) consisted of dermatology (15 [33%]), medical oncology (7 [16%]), radiation oncology (9 [20%]), radiology (9 [20%]), surgery (3 [7%]), and otolaryngology specialists (2 [4%]). The Delphi panel recommended staging and surveillance for CSCCs with at least a 15% risk of metastasis. Consensus or near consensus was reached to recommend staging and surveillance imaging for tumors with a concern for metastasis, bone invasion, invasion beyond subcutaneous fat, large-caliber nerve invasion, or a diameter of 4 cm or larger or the combination of tumors with poorly differentiated histology and any of the following: diameter of 2 cm or larger, lymphovascular invasion and subcutaneous fat invasion, or lymphovascular invasion and small-caliber perineural invasion. Computed tomography imaging was the preferred modality for nodal staging (38 [84%]) and surveillance (35 [78%]). For surveillance duration, consensus was reached to provide imaging for at least 2 years, and near consensus was reached for at least 3 years. Conclusions and Relevance This study provides an expert consensus–based framework to standardize imaging in localized CSCC that may inform future guidelines.
Appetite Suppression by
GLP
‐1 Receptor Agonists: Role of Delayed Gastric Emptying
ABSTRACT Objective This study aimed to evaluate relationships between delayed gastric emptying and appetite suppression during treatment with liraglutide, a glucagon‐like peptide‐1 receptor agonist (GLP‐1RA). Methods We conducted a secondary data analysis from a 16‐week randomized, placebo‐controlled liraglutide trial in patients with obesity. We examined correlations between solid food gastric emptying and measurements of satiation and energy intake in the entire cohorts at baseline and end of treatment and separately in placebo‐ and liraglutide‐treated patients who completed the trial. We also compared appetitive measures among liraglutide‐treated participants who displayed either normal, persistently delayed, or transiently delayed emptying during treatment. Results In the entire cohorts at baseline and completion, gastric emptying correlated significantly with energy intake and, at baseline, with one parameter of satiation. Gastric emptying accounted for only 4%–6% of the variance in these appetitive measures. No such correlations were found in the placebo‐ or liraglutide‐treated groups alone. There were no differences in appetitive measures among the subgroups that displayed different gastric emptying patterns during liraglutide treatment. Conclusions Delayed gastric emptying appears to play little direct role in appetite suppression induced by liraglutide. Further research should explore whether delayed emptying or other gastrointestinal effects of other GLP‐1RAs affect appetite directly or indirectly. Trial Registration: ClinicalTrials.gov identifier: NCT02647944
Longitudinal Dynamics of Polyglutamine‐Expanded
ATXN3
in Biofluids of Spinocerebellar Ataxia Type 3
Abstract Introduction Energy harvesters that convert biomechanical energy into electrical power could be used for implantable devices, providing a near-infinite energy solution. While various energy harvesters with piezoelectric or triboelectric elements have been designed and applied to the cardiac environment, none have been successfully integrated into leadless pacemakers due to their size constraints or insufficient energy generation. Purpose This study aimed to test the performance of a novel self-sustaining leadless pacemaker, which operates on a proprietary inertial piezoelectric energy harvester (PEH) capable of generating the energy required for VVI therapy from the beating of the heart. Method A novel autonomous Leadless Pacing System (ALPS), including a leadless implant, a customized delivery tool catheter, and a home monitor, was developed. The leadless implant was designed to operate on the energy generated by a specially designed PEH that could fit inside the implant. The harvester’s energy was used to charge a small rechargeable backup battery, which provided the energy for a VVI single-chamber therapy. The leadless device and its dedicated delivery tool were then tested in vivo in an ovine model, adhering to the principles of laboratory animal care and with local ethical approval. Results The heart contractility creates harmonic movement in the heart tissue, which is transmitted into the PEH, resulting in the PEH acceleration. The leadless PEH components transform these mechanical forces into electric energy. In pre-clinical testing on an AV block ovine model (n=7), the device was able to pace the animals for 3 months, at 100% pacing, with an average pacing capture threshold of 0.9 (+/-0.5)V, with a pulse width of 0.366 msec, an average impedance of 570 (+/- 115) Ohm, and daily communication with the home monitor device. Conclusion This work demonstrates that a novel leadless pacemaker that utilizes a piezoelectric element to harvest the heart's mechanical energy to generate electrical energy successfully sustains VVI therapy. This approach is able to produce enough energy to maintain device longevity and support additional functionality, such as daily wireless communication with a home monitor, overcoming major limitations of leadless cardiac devices.
Predicting atrial fibrillation in the real world: head-to-head comparison of five risk scores
Abstract Introduction Atrial fibrillation (AF) is a major contributor to stroke risk, yet many cases remain undiagnosed due to its silent and paroxysmal nature. To address this, multiple risk scores have been developed to predict incident AF. This study aimed to evaluate the predictive accuracy of five widely used clinical AF prediction tools (i.e., CHARGE-AF, CHA2DS2-VASc, mC2HEST, HATCH, and HAVOC) among patients undergoing long-term continuous monitoring with implantable loop recorders (ILRs). Methods We conducted a retrospective cohort study across three major US academic medical centers, including patients with ILRs and no prior diagnosis or ECG evidence of AF. Clinical variables used to calculate each risk score were extracted from electronic health records. Discrimination was assessed using the area under the receiver operating characteristic curve (AUC). Kaplan-Meier survival analysis and Cox proportional hazards models were used to evaluate the association between each score’s risk categories and incident AF (defined as any episode lasting ≥6 minutes). Calibration was assessed using calibration plots and Brier scores. Results A total of 3,895 patients were included (mean age 61 ± 17 yrs.; 51% male). Incident AF was detected in 879 patients (22%) over a median follow up of 17 months (IQR 8-35). Table 1 presents baseline characteristics and device detected AF event data during follow up. CHARGE-AF had the highest AUC (0.68) but also the highest Brier score (Fig. 1). Failure curves showed clear risk stratification across all tools (Fig. 2). Calibration plots (Fig. 3) demonstrated modest agreement between predicted and observed risk across all models. Using CHARGE-AF as the reference, pairwise comparisons of Brier scores via the Wilcoxon signed-rank test showed lower calibration accuracy than CHA2DS2-VASc (p = 0.03), mC2HEST (p = 0.001), and HAVOC (p = 0.001), with no significant difference compared to HATCH (p = 0.15). Conclusions In patients undergoing continuous rhythm monitoring with ILRs, commonly used AF prediction scores demonstrated modest discriminatory ability and similar calibration performance. These findings suggest that existing risk models, which were largely developed in cohorts with clinically diagnosed AF, may not optimally translate to continuously monitored populations. Future work is needed to develop and validate AF prediction models specifically in cohorts undergoing long-term continuous cardiac monitoring.Figure 1Figure 2-3
Quantifying performance of high-density mapping catheters in in-vivo and benchtop models
Abstract Background/Introduction High-density mapping catheters enhance the speed and accuracy of 3-dimensional data collection. However, differences in data acquisition, efficiency, and system processing are not well quantified, even for catheters with similar form factors. Purpose Compare in-vivo and bench performance of the HD Grid X (EnSite X v 5.0.1) and Optrell (Carto v 8.1.1) catheters. Criteria include mapping and modeling efficiency, electrogram (EGM) amplitude dependence on orientation, and resolution of low voltage boundaries. Methods In-vivo: In 6 swine, 5 physicians used each catheter in a randomized order to create models of equivalent detail of the left atrium (LA) and ventricle (LV) during atrial pacing. Comparable mapping parameters were selected between the respective mapping systems. Each mapping catheter was then placed in a stable location at 3 different anatomical sites in the LA and rotated while collecting manual map points. In the right atrium (RA), an independent operator placed groups of 5-6 radiofrequency (RF) lesions with a focal ablation catheter. Each physician, being blinded to the ablated areas, remapped the RA and identified the area(s) they assessed as being ablated. The indicated regions were measured on the mapping system and compared to the actual ablated area(s) observed during necropsy. Bench: Using a wavefront emulator platform, 2 propagation patterns were created—case 1: a single uniform wavefront propagating across the platform, and case 2: two uniform wavefronts colliding in the center of the platform creating a low-voltage region. For both cases, during map collection, the catheter was oriented at 3 different angles (0, 45, and 90 deg.) relative to the propagation direction. For case 1, the EGM amplitudes were compared. For case 2, the spatial resolution of the low-voltage region was defined by the full-width at half max (FWHM), i.e., the measured width of the area containing less than half the max amplitude. Results In-Vivo: Median rate of mapping point acquisition for Grid X was higher than Optrell by 167% (p=0.02; 48,18 points/s) in the LA and 39% (p=0.03; 18,13 points/s) in the LV. Median time for model completion for Grid X was shorter than Optrell by 39% (p=0.047; 318s, 525s) in the LA and 45% (p=0.02; 342s, 620s) in the LV. Grid X measured higher amplitude EGMs in all 3 LA locations (Fig 1). The mean error in the lesion areas identified by Grid X was 25% lower than Optrell (p=0.04; 154, 204 mm²). Bench: In case 1, Grid X recorded a median normalized amplitude which was 58% larger than Optrell (Fig 1). In case 2, Grid X recorded a median voltage resolution which was 34% finer than Optrell (Fig 2). Conclusion Design considerations beyond catheter shape may impact mapping quality and speed. Grid X collects mapping and geometry data faster, is less reliant on catheter orientation to collect high voltage EGMs, and more accurately defines low voltage boundaries compared to Optrell.Figure 1:EGM Amplitude DataFigure 2:Voltage Resolution
Vascular Risk Prediction in Migraine: A Multimodality Risk Score Based on Artificial Intelligence-electrocardiogram Output, Echocardiography, and Detailed Migraine Characteristics (S23.007)
Beyond Atrial Shunt-A Comprehensive Study of Echocardiogram Findings and Their Association with Adverse Vascular Events in Patients with Migraine (S23.008)