Citations

Clear

201 citation(s) found for "Lieske, John C".

Shock Wave Lithotripsy is Not Predictive of Hypertension Among Community Stone Formers at Long-Term Followup
Krambeck, Amy E. , Li, Xujian, Bergstralh, Eric J., Gettman, Matthew T., Rule, Andrew D. , Lieske, John C.

Mayo Clinic

Journal of Urology | November 14, 2010 | Volume: 185 | Issue: 1 | Pages: 164-169

10.1016/j.juro.2010.09.033 | PMID 21074794 Get It

Cardiac Abnormalities in Primary Hyperoxaluria
Mookadam, Farouk , Smith, Travis , Jiamsripong, Panupong, Moustafa, Sherif E, Monico, Carla G., Milliner, Dawn S. , Moustafa, Sherif E, Lieske, John C.

Mayo Clinic

Circulation Journal | September 29, 2010 | Volume: 74 | Issue: 11 | Pages: 2403-2409

10.1253/circj.cj-10-0107 | PMID 20921818 Get It

Decursin Prevents Cisplatin-Induced Apoptosis via the Enhancement of Antioxidant Enzymes in Human Renal Epithelial Cells
Kim, Jeong Hwan , Jeong, Soo‐Jin , Kwon, Hee Young , Lee, Hyo‐Jeong , Kim, Sung‐Hoon , Park, Sang Yoon , Lee, Hyo‐Jung , Lieske, John C.

Mayo Clinic

Biological and Pharmaceutical Bulletin | August 2, 2010 | Volume: 33 | Issue: 8 | Pages: 1279-1284

10.1248/bpb.33.1279 | PMID 20686219 Get It

Progressive renal papillary calcification and ureteral stone formation in mice deficient for Tamm-Horsfall protein
Liu, Yan , Mo, Lan , Goldfarb, David S. , Evan, Andrew P., Liang, Feng‐Xia , Khan, Saeed R. , Wu, Xue‐Ru , Lieske, John C. , Goldfarb, David S

Mayo Clinic

American Journal of Physiology-Renal Physiology | July 12, 2010 | Volume: 299 | Issue: 3 | Pages: F469-F478

10.1152/ajprenal.00243.2010 | PMID 20591941 Get It

Mammalian urine contains a range of macromolecule proteins that play critical roles in renal stone formation, among which Tamm-Horsfall protein (THP) is by far the most abundant. While THP is a potent inhibitor of crystal aggregation in vitro and its ablation in vivo predisposes one of the two existing mouse models to spontaneous intrarenal calcium crystallization, key controversies remain regarding the role of THP in nephrolithiasis. By carrying out a long-range follow-up of more than 250 THP-null mice and their wild-type controls, we demonstrate here that renal calcification is a highly consistent phenotype of the THP-null mice that is age and partially gene dosage dependent, but is gender and genetic background independent. Renal calcification in THP-null mice is progressive, and by 15 mo over 85% of all the THP-null mice develop spontaneous intrarenal crystals. The crystals consist primarily of calcium phosphate in the form of hydroxyapatite, are located more frequently in the interstitial space of the renal papillae than intratubularly, particularly in older animals, and lack accompanying inflammatory cell infiltration. The interstitial deposits of hydroxyapatite observed in THP-null mice bear strong resemblances to the renal crystals found in human kidneys bearing idiopathic calcium oxalate stones. Compared with 24-h urine from the wild-type mice, that of THP-null mice is supersaturated with brushite (calcium phosphate), a stone precursor, and has reduced urinary excretion of citrate, a stone inhibitor. While less frequent than renal calcinosis, renal pelvic and ureteral stones and hydronephrosis occur in the aged THP-null mice. These results provide direct in vivo evidence indicating that normal THP plays an important role in defending the urinary system against calcification and suggest that reduced expression and/or decreased function of THP could contribute to nephrolithiasis.
Iothalamate Quantification by Tandem Mass Spectrometry to Measure Glomerular Filtration Rate
Seegmiller, Jesse C. , Burns, Bradley E., Fauq, Abdul H. , Mukhtar, Naveen, Larson, Timothy S., Lieske, John C.

Mayo Clinic

Clinical Chemistry | February 19, 2010 | Volume: 56 | Issue: 4 | Pages: 568-574

10.1373/clinchem.2009.133751 | PMID 20167698 Get It

Abstract Background: Glomerular filtration rate (GFR) can be determined by measuring renal clearance of the radiocontrast agent iothalamate. Current analytic methods for quantifying iothalamate concentrations in plasma and urine using liquid chromatography or capillary electrophoresis have limitations such as long analysis times and susceptibility to interferences. We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to overcome these limitations. Methods: Urine and plasma samples were deproteinized using acetonitrile and centrifugation. The supernatant was diluted in water and analyzed by LC-MS/MS using a water:methanol gradient. We monitored 4 multiple reaction monitoring transitions: m/z 614.8–487.0, 614.8–456.0, 614.8–361.1, and 614.8–177.1. We compared the results to those obtained via our standard capillary electrophoresis (CE-UV) on samples from 53 patients undergoing clinical GFR testing. Results: Mean recovery was 90%–110% in both urine and plasma matrices. Imprecision was ≤15% for the m/z 614.8–487.0 and 614.8–456.0 transitions over a 10-day period at 1 mg/L. Method comparison for 159 patient samples (53 clearances) provided the following Passing–Bablok regressions: plasma iothalamate LC-MS/MS (y) vs CE-UV (x), y = 0.99x + 0.36; urine iothalamate LC-MS/MS vs CE-UV, y = 1.01x + 0.31; corrected GFR LC-MS/MS vs CE-UV, y = 1.00x + 0.00. Interfering substances prevented accurate iothalamate quantification by CE-UV in 2 patients, whereas these samples could be analyzed by LC-MS/MS. Conclusions: Iothalamate can be quantified by LC-MS/MS for GFR measurement. This method circumvents potential problems with interfering substances that occasionally confound accurate GFR determinations.
Characterization of Biofilm Formed by Human-Derived Nanoparticles
Schwartz, Maria K., Huebner, Marianne , Miller, Virginia M. , Hunter, Larry W. , Lieske, John C.

Mayo Clinic

Nanomedicine | December 4, 2009 | Volume: 4 | Issue: 8 | Pages: 931-941

10.2217/nnm.09.72 | PMID 19958229 Get It

Biologic Nanoparticles and Platelet Reactivity
Miller, Virginia M. , Chu, Kevin, Kaul, Vivasvat, Squillace, Phillip D, Jayachandran, Muthuvel , Hunter, Larry W. , Lieske, John C.

Mayo Clinic

Nanomedicine | October 20, 2009 | Volume: 4 | Issue: 7 | Pages: 725-733

10.2217/nnm.09.61 | PMID 19839809 Get It

Gastric Bypass Procedures and Renal Calculi—How Should We Counsel Patients and Bariatric Surgeons?
Lieske, John C.

Mayo Clinic

Journal of Urology | September 17, 2009 | Volume: 182 | Issue: 5 | Pages: 2105-2106

10.1016/j.juro.2009.08.079 | PMID 19758648 Get It

Comparison of Urinary Albumin Quantification by Immunoturbidimetry, Competitive Immunoassay, and Protein-Cleavage Liquid Chromatography–Tandem Mass Spectrometry
Seegmiller, Jesse C. , Sviridov, Denis, Larson, Timothy S., Borland, Timothy M., Hortin, Glen L. , Lieske, John C.

Mayo Clinic

Clinical Chemistry | September 10, 2009 | Volume: 55 | Issue: 11 | Pages: 1991-1994

10.1373/clinchem.2009.129833 | PMID 19745060 Get It

Abstract Background: Increased urinary albumin excretion is a well-documented diagnostic and prognostic biomarker for renal disease. Urinary albumin is typically measured in clinical settings by immunoassay methods. However, neither a reference method nor a urine albumin calibration reference material is currently available. Methods: We quantified urinary albumin in patient samples by using 3 commercially available reagent systems: DiaSorin SPQ™ and Beckman Coulter LX® 20 (immunoturbidimetric), and Siemens Immulite® (competitive immunoassay). Results were compared to values obtained by protein-cleavage liquid chromatography–tandem mass spectrometry (LC-MS/MS). Results: In general, results from the 3 immunoassays agreed with results from LC-MS/MS. However, the SPQ results showed a negative bias across all ranges of albuminuria [(0–200 mg/L, y = 0.91x – 3.74 (CI 0.86–0.96); > 200 mg/L, y = 0.88x – 40.30 (CI 0.76–1.00)], whereas the LX 20 showed minimal bias in the 0–200 mg/L range [y = 0.97x − 88 (CI 0.92–1.02)] and the Immulite assay showed positive bias in the 0–200 mg/L range [y = 1.15x – 4.38 (CI 1.09–1.20)]. Conclusions: These results showed a reasonable quantification of urinary albumin by representative polyclonal and monoclonal immunoassays compared to an LC-MS/MS assay. In addition, the results do not suggest the presence of nonimmunoreactive albumin in urine. However, differences in analytic performance between assays support the need for a reference calibration material and reference method to standardize clinical laboratory measurements of urinary albumin.
Quantification of Urinary Albumin by Using Protein Cleavage and LC-MS/MS
Seegmiller, Jesse C. , Barnidge, David R. , Burns, Bradley E., Larson, Timothy S., Kumar, Rajiv , Lieske, John C. , Kumar, Rajiv

Mayo Clinic

Clinical Chemistry | March 27, 2009 | Volume: 55 | Issue: 6 | Pages: 1100-1107

10.1373/clinchem.2008.115543 | PMID 19325011 Get It

Abstract Background: Urinary albumin excretion is a sensitive diagnostic and prognostic marker for renal disease. Therefore, measurement of urinary albumin must be accurate and precise. We have developed a method to quantify intact urinary albumin with a low limit of quantification (LOQ). Methods: We constructed an external calibration curve using purified human serum albumin (HSA) added to a charcoal-stripped urine matrix. We then added an internal standard, 15N-labeled recombinant HSA (15NrHSA), to the calibrators, controls, and patient urine samples. The samples were reduced, alkylated, and digested with trypsin. The concentration of albumin in each sample was determined by liquid chromatography–tandem mass spectrometry (LC-MS/MS) and linear regression analysis, in which the relative abundance area ratio of the tryptic peptides 42LVNEVTEFAK51 and 526QTALVELVK534 from albumin and 15NrHSA were referenced to the calibration curve. Results: The lower limit of quantification was 3.13 mg/L, and the linear dynamic range was 3.13–200 mg/L. Replicate digests from low, medium, and high controls (n = 5) gave intraassay imprecision CVs of 2.8%–11.0% for the peptide 42LVNEVTEFAK51, and 1.9%–12.3% for the 526QTALVELVK534 peptide. Interassay imprecision of the controls for a period of 10 consecutive days (n = 10) yielded CVs of 1.5%–14.8% for the 42LVNEVTEFAK51 peptide, and 6.4%–14.1% for the 526QTALVELVK534 peptide. For the 42LVNEVTEFAK51 peptide, a method comparison between LC-MS/MS and an immunoturbidometric method for 138 patient samples gave an R2 value of 0.97 and a regression line of y = 0.99x + 23.16. Conclusions: Urinary albumin can be quantified by a protein cleavage LC-MS/MS method using a 15NrHSA internal standard. This method provides improved analytical performance in the clinically relevant range compared to a commercially available immunoturbidometric assay.