Citations

Clear

385 citation(s) found for "Holmes, David R".

Nanoparticle-Mediated Cell Capture Enables Rapid Endothelialization of a Novel Bare Metal Stent
Tefft, Brandon J. , Uthamaraj, Susheil , Harbuzariu, Adriana , Harburn, J. Jonathan, Witt, Tyra A. , Newman, B., Psaltis, Peter J. , Hlinomaz, Ota , Holmes, David R. , Gulati, Rajiv , Simari, Robert D., Dragomir‐Daescu, Dan , Sandhu, Gurpreet S. , Newman, Brant

Mayo Clinic

Tissue Engineering Part A | February 12, 2018 | Volume: 24 | Issue: 13-14 | Pages: 1157-1166

10.1089/ten.tea.2017.0404 | PMID 29431053 Get It

Association Between Left Atrial Appendage Occlusion and Readmission for Thromboembolism Among Patients With Atrial Fibrillation Undergoing Concomitant Cardiac Surgery
Piccini, Jonathan P. , Wang, Tongrong, Malaisrie, S. Chris, Holmes, David R. , Suri, Rakesh M. , Mack, Michael J. , Badhwar, Vinay , Gaca, Jeffrey G., Chow, Shein‐Chung, Brennan, James M. , Malaisrie, S. Chris , Friedman, Daniel J , Zheng, Jiayin , Jacobs, Jeffrey P. , Peterson, Eric D.

Mayo Clinic

JAMA | January 23, 2018 | Volume: 319 | Issue: 4 | Pages: 365

10.1001/jama.2017.20125 | PMID 29362794 Get It

Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification
Sabbagh, Abdallah El , Eleid, Mackram F. , Matsumoto, Jane M., Anavekar, Nandan S., Al‐Hijji, Mohammed , Said, Sameh M. , Holmes, David R. , Rihal, Charanjit S. , Foley, Thomas A. , El Sabbagh, Abdallah , Al-Hijji, Mohammed A , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 | PMID 29359388 Get It

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
The Heart-Brain Team—Towards Optimal Team-Based Coordinated Care
Graff‐Radford, Jonathan , Holmes, David R. , Alkhouli, Mohamad

Mayo Clinic

JAMA Cardiology | January 17, 2018 | Volume: 3 | Issue: 3 | Pages: 187

10.1001/jamacardio.2017.5072 | PMID 29344618 Get It

Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
Thaden, Jeremy J. , Malouf, Joseph F., Pislaru, Sorin V. , Holmes, David R. , Reeder, Guy S., Rihal, Charanjit S. , Eleid, Mackram F. , Sabbah, Michael S. , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Mayo Clinic

Journal of the American Heart Association | January 13, 2018 | Volume: 7 | Issue: 2 | Pages: No page available

10.1161/jaha.117.007315 | PMID 29331957 Get It

Background Mitral regurgitation is a heterogeneous disease. Determining which patients derive optimal outcomes from transcatheter edge‐to‐edge mitral valve repair (TMVR) remains challenging. We sought to determine whether baseline mitral valve anatomic characteristics are predictive of left atrial pressure (LAP) changes during TMVR with MitraClip. Methods and Results Consecutive patients with severe mitral regurgitation undergoing TMVR (n=112) underwent continuous intraprocedural LAP monitoring and retrospective echocardiographic analysis for specific mitral anatomic characteristics. Procedural success (optimal LAP reduction) was defined as ≥40% reduction in left atrial V‐wave pressure compared with baseline. Echocardiographic predictors of optimal LAP reduction and increased postprocedure mean diastolic gradient were evaluated. Mean age was 79±14 years, and 36 patients (32%) were women. Primary, mixed, and secondary mitral regurgitation were present in 78 patients (70%), 22 patients (20%), and 12 patients (10%), respectively. Baseline mean LAP and V‐wave were 22±6 and 38±13 mm Hg; after TMVR, these decreased to 19±5 and 27±10 mm Hg, respectively ( P <0.0001 for both). Independent predictors of optimal LAP reduction were the presence of a flail scallop, mitral regurgitation localized to a single scallop, and high‐quality 3‐dimensional echocardiographic imaging. Independent predictors of elevated postprocedure mean diastolic gradient were elevated preprocedure mean diastolic gradient, mitral annular calcification, and implantation of multiple clips. Conclusions Mitral valve pathoanatomic features, including a flail leaflet and single jet, are predictive of optimal LAP reduction with TMVR. High‐quality 3‐dimensional imaging may help select patients with the highest likelihood of optimal hemodynamic results with TMVR. These data expand current knowledge about patient selection for TMVR and deserve further study in larger cohorts.
Analysis of Brain SPECT Images Coregistered with MRI in Patients with Epilepsy: Comparison of Three Methods
Long, Zaiyang , Mullan, Brian P., Holmes, David R. , Brinkmann, Benjamin H. , O’Connor, Michael K. , Hanson, Dennis P. , Hunt, Christopher H. , O'Connor, Michael K, Brinkmann, Benjamin H

Mayo Clinic

Journal of Neuroimaging | January 10, 2018 | Volume: 28 | Issue: 3 | Pages: 307-312

10.1111/jon.12496 | PMID 29319202 Get It

ABSTRACT BACKGROUND AND PURPOSE SISCOM and STATISCOM were clinically proved to be effective for ictal/inter‐ictal single‐photon emission computed tomography (SPECT) analysis coregistered with magnetic resonance imaging (MRI) for seizure localization. Recently, a software package also became available for this analysis. This study aimed to investigate and compare the performance of these analysis methods for seizure localization. METHODS A total of 378 patients who underwent 99m Tc‐ethyl cysteinate dimer (ECD) SPECT scans were retrospectively reviewed and 28 remained after applying exclusion criteria. Their SPECT and MRI images were analyzed with SISCOM (with z ‐score of 1.5 and 2), STATISCOM, and MIMneuro, resulting in a total of 112 image data sets. Two experienced radiologists participated in the blind review process using a custom tool and they can mark up to two hyper‐ and/or hypoperfusion regions. Their review results were analyzed using the Jackknife Free Response Receiver‐Operating Characteristics (JAFROC) test and the JAFROC figure‐of‐merit (FoM) was reported for each method. The interobserver agreement was also assessed using Cohen's kappa test. RESULTS Based on the readers’ two choices, averaged FoM was 85.7%, 83.9%, 66.1%, and 51.8% for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. The average confidence rating was 2.5, 2.3, 1.6, and 1.1 for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. For interobserver agreement, kappa was .742 for STATISCOM, .816 for MIMneuro, .517 for SISCOM ( z ‐score = 2), and .441 for SISCOM ( z ‐score = 1.5; all P < .001). CONCLUSION Our study demonstrated that STATISCOM showed the best performance for seizure localization, which was closely followed by MIMneuro. In addition, MIMneuro was not inferior to SISCOM with either z ‐score.
Pregnancy history, coronary artery calcification and bone mineral density in menopausal women
Beckman, John , Camp, Jon J. , Lahr, Brian D. , Bailey, Kent R. , Kearns, Ann E. , Jayachandran, Muthuvel , Miller, Virginia M. , Holmes, David R. , Garovic, Vesna D.

Mayo Clinic

Climacteric | November 30, 2017 | Volume: 21 | Issue: 1 | Pages: 53-59

10.1080/13697137.2017.1406910 | PMID 29189095 Get It

Clinical Impact of Diabetes Mellitus on Outcomes After Transcatheter Aortic Valve Replacement
Abramowitz, Yigal, Vemulapalli, Sreekanth , Chakravarty, Tarun , Li, Zhuokai , Holmes, David R. , Wang, Alice , Cheng, Wen , Forrester, James S. , Smalling, Richard W. , Thourani, Vinod H. , Mack, Michael J. , Leon, Martin B. , Makkar, Raj , Douglas, Pamela S. , Matsouaka, Roland A, Smalling, Richard, Thourani, Vinod, Mack, Michael, Leon, Martin, Makkar, Raj R., Douglas, Pamela S , Kapadia, Samir , Matsouaka, Roland

Mayo Clinic

Circulation: Cardiovascular Interventions | November 14, 2017 | Volume: 10 | Issue: 11 | Pages: No page available

10.1161/circinterventions.117.005417 | PMID 29138245 Get It

Background— Diabetes mellitus (DM) adversely affects morbidity and mortality for cardiovascular diseases and procedures. Data evaluating the outcomes of transcatheter aortic valve replacement (TAVR) in diabetic patients are limited by small sample size and contradictory results. We aimed to establish the magnitude of risk and the incremental influence of insulin dependency by examining short- and long-term adverse outcomes according to DM status and therapy in the world’s largest TAVR registry. Methods and Results— We analyzed data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. In-hospital mortality, 30-day mortality, and 1-year mortality after TAVR in patients with and without DM were evaluated using multivariate modeling. Among 47 643 patients treated with TAVR from November 2011 through September 2015 at 394 US hospitals, there were 17 849 (37.5%) patients with DM. Overall, 6600 of the diabetic patients were insulin treated (IT). Thirty-day mortality was 5.0% in patients with DM (6.1% in IT DM and 4.4% in non-IT DM; P <0.001) versus 5.9% in patients without DM ( P <0.001). Overall, 1-year mortality was 21.8% in patients with DM (24.8% in IT DM and 20.1% in non-IT DM; P <0.001) versus 21.2% in patients without DM ( P =0.274). In a multivariable model, DM was associated with increased 1-year mortality (hazard ratio, 1.30; 95% confidence interval, 1.13–1.49; P <0.001). Subgroup multivariable analysis showed stronger mortality association in IT diabetics (hazard ratio, 1.57; 95% confidence interval, 1.28–1.91; P <0.001) than in non-IT diabetics (hazard ratio, 1.17; 95% confidence interval, 1.00–1.38; P =0.052). Conclusions— Our data establish the magnitude of short- and long-term risk conferred by DM and the incremental risk conferred by insulin dependency in the performance of TAVR. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Peripheral Artery Disease and Transcatheter Aortic Valve Replacement Outcomes
Fanaroff, Alexander C. , Manandhar, Pratik , Holmes, David R. , Harrison, J. Kevin , Thourani, Vinod H. , Mack, Michael J. , Sherwood, Matthew W. , Vemulapalli, Sreekanth , Douglas, Pamela S. , Hughes, G Chad, Jones, W Schuyler, Douglas, Pamela S , Cohen, David Jonathan , Hughes, George Chad , Jones, W. Schuyler , Fanaroff, Alexander C

Mayo Clinic

Circulation: Cardiovascular Interventions | October 17, 2017 | Volume: 10 | Issue: 10 | Pages: No page available

10.1161/circinterventions.117.005456 | PMID 29042398 Get It

Background— Peripheral artery disease (PAD) is associated with increased cardiovascular mortality, and PAD risk factors overlap with those for aortic stenosis. The prevalence and outcomes associated with PAD in a population undergoing transcatheter aortic valve replacement (TAVR) are unknown. Methods and Results— Using the Society of Thoracic Surgeons/Transcatheter Valve Therapy Registry linked to Medicare claims data, we identified patients ≥65 years old undergoing TAVR from 2011 to 2015. We calculated hazard ratios for 1-year adverse outcomes, including mortality, readmission, and bleeding, for patients with PAD compared with those without, adjusting for baseline characteristics and postprocedure medications. Analyses were performed separately by access site (transfemoral and nontransfemoral). Of 19 660 patients undergoing transfemoral TAVR, 4810 (24.5%) had PAD; 3730 (47.9%) of 7780 patients undergoing nontransfemoral TAVR had PAD. In both groups, patients with PAD were significantly more likely to have coronary and carotid artery diseases. At 1-year follow-up, patients with PAD undergoing TAVR via transfemoral access had a higher incidence of death (16.8% versus 14.4%; adjusted hazard ratio, 1.14; P =0.01), readmission (45.5% versus 42.1%; hazard ratio, 1.11; P <0.001), and bleeding (23.1% versus 19.7%; hazard ratio, 1.18; P <0.001) compared with patients without PAD. Patients with PAD undergoing TAVR via nontransfemoral access did not have significantly higher rates of 1-year mortality or readmission compared with patients without PAD. Conclusions— PAD is common among patients undergoing commercial TAVR via transfemoral and nontransfemoral access. Among patients undergoing transfemoral TAVR, PAD is associated with a higher incidence of 1-year adverse outcomes compared with absence of PAD. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Low‐dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
Bartley, Adam C. , Carter, Rickey E. , Chen, Baiyu , Drees, Tammy A., Edwards, Phillip K , Holmes, David R. , Huang, Alice E. , Khan, Farhana, McMillan, Kyle, Michalak, Gregory J. , Nunez, Kristina M., Yu, Lifeng , Edwards, Phillip, McMillan, Kyle L, Carter, Rickey E , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng , Fletcher, Joel G.

Mayo Clinic

Medical Physics | October 13, 2017 | Volume: 44 | Issue: 10 | Pages: No page available

10.1002/mp.12345 | PMID 29027235 Get It

Purpose Using common datasets, to estimate and compare the diagnostic performance of image‐based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases. Methods Datasets from contrast‐enhanced CT scans of the liver were provided to participants in an NIH ‐, AAPM ‐ and Mayo Clinic‐sponsored Low Dose CT Grand Challenge. Training data included full‐dose and quarter‐dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data. Projection data were supplied in a vendor‐neutral standardized format ( DICOM ‐ CT ‐ PD ). Twenty quarter‐dose patient datasets were provided to each participant for testing the performance of their technique. Images were provided to sites intending to perform denoising in the image domain. Fully preprocessed projection data and statistical noise maps were provided to sites intending to perform iterative reconstruction. Upon return of the denoised or iteratively reconstructed quarter‐dose images, randomized, blinded evaluation of the cases was performed using a Latin Square study design by 11 senior radiology residents or fellows, who marked the locations of identified hepatic metastases. Markings were scored against reference locations of clinically or pathologically demonstrated metastases to determine a per‐lesion normalized score and a per‐case normalized score (a faculty abdominal radiologist established the reference location using clinical and pathological information). Scores increased for correct detections; scores decreased for missed or incorrect detections. The winner for the competition was the entry that produced the highest total score (mean of the per‐lesion and per‐case normalized score). Reader confidence was used to compute a Jackknife alternative free‐response receiver operating characteristic ( JAFROC ) figure of merit, which was used for breaking ties. Results 103 participants from 90 sites and 26 countries registered to participate. Training data were shared with 77 sites that completed the data sharing agreements. Subsequently, 41 sites downloaded the 20 test cases, which included only the 25% dose data ( CTDI vol = 3.0 ± 1.8 mG y, SSDE = 3.5 ± 1.3 mG y). 22 sites submitted results for evaluation. One site provided binary images and one site provided images with severe artifacts; cases from these sites were excluded from review and the participants removed from the challenge. The mean (range) per‐lesion and per‐case normalized scores were −24.2% (−75.8%, 3%) and 47% (10%, 70%), respectively. Compared to reader results for commercially reconstructed quarter‐dose images with no noise reduction, 11 of the 20 sites showed a numeric improvement in the mean JAFROC figure of merit. Notably two sites performed comparably to the reader results for full‐dose commercial images. The study was not designed for these comparisons, so wide confidence intervals surrounded these figures of merit and the results should be used only to motivate future testing. Conclusion Infrastructure and methodology were developed to rapidly estimate observer performance for liver metastasis detection in low‐dose CT examinations of the liver after either image‐based denoising or iterative reconstruction. The results demonstrated large differences in detection and classification performance between noise reduction methods, although the majority of methods provided some improvement in performance relative to the commercial quarter‐dose images with no noise reduction applied.