Citations

Clear

1828 citation(s) found for "Su, Emily".

Clinical and biologic implications of recurrent genomic aberrations in myeloma
Fonseca, Rafaël , Blood, Emily, Rué, Montserrat , Harrington, David , Oken, Martin M., Kyle, Robert A. , Dewald, Gordon W., Ness, Brian Van, Wier, Scott A. Van, Henderson, Kimberly J., Bailey, Richard J., Greipp, Philip R., Fonseca, Rafael

Mayo Clinic

Blood | May 19, 2003 | Volume: 101 | Issue: 11 | Pages: 4569-4575

10.1182/blood-2002-10-3017 | PMID 12576322 Get It

Abstract Nonrandom recurrent chromosomal abnormalities are ubiquitous in multiple myeloma (MM) and include, among others, translocations of the immunoglobulin heavy chain locus (IgH). IgH translocations in MM result in the up-regulation of oncogenes, and include more commonly t(11;14)(q13;q32), t(4;14)(p16;q32), and t(14;16)(q32;q23). Based on the recurrent nature of these translocations and their finding since the early stages of the plasma cell (PC) disorders, we hypothesized that they would confer biologic and clinical variability. In addition, deletions of 13q14 and 17p13 have also been associated with a shortened survival. We used cytoplasmic Ig—enhanced interphase fluorescent in situ hybridization to detect deletions (13q14 and 17p13.1), and translocations involving IgH in 351 patients treated with conventional chemotherapy entered into the Eastern Cooperative Oncology Group clinical trial E9486/9487. Translocations were frequently unbalanced with loss of one of the derivative chromosomes. The presence of t(4; 14)(p16;q32) (n = 42; 26 vs 45 months, P < .001), t(14;16)(q32;q23) (n = 15; 16 vs 41 months, P = .003), – 17p13 (n = 37; 23 vs 44 months, P = .005), and – 13q14 (n = 176; 35 vs 51 months, P = .028) were associated with shorter survival. A stratification of patients into 3 distinct categories allowed for prognostication: poor prognosis group (t(4;14)(p16;q32), t(14; 16)(q32;q23), and – 17p13), intermediate prognosis (– 13q14), and good prognosis group (all others), with median survivals of 24.7, 42.3, and 50.5 months, respectively (P < .001). This molecular cytogenetic classification identifies patients into poor, intermediate, and good risk categories. More importantly it provides further compelling evidence that MM is composed of subgroups of patients categorized according to their underlying genomic aberrations.
Comparison of LightCycler PCR, Rapid Antigen Immunoassay, and Culture for Detection of Group A Streptococci from Throat Swabs
Uhl, J. R., Adamson, Steven C., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Iverson, L. K., Santrach, Paula J., Henry, Nancy K., Cockerill, Franklin R.

Mayo Clinic

Journal of Clinical Microbiology | January 7, 2003 | Volume: 41 | Issue: 1 | Pages: 242-249

10.1128/jcm.41.1.242-249.2003 | PMID 12517855 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results ( n = 58) than either culture ( n = 55) or the Directigen immunoassay ( n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted “gold standard,” bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR ( n = 7) or the Directigen method ( n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant ( P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time (∼1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).
Myeloma and the t(11;14)(q13;q32); evidence for a biologically defined unique subset of patients
Fonseca, Rafaël , Blood, Emily, Oken, Martin M., Kyle, Robert A. , Dewald, Gordon W., Bailey, Richard J., Wier, Scott A. Van, Henderson, Kimberly J., Hoyer, James D., Harrington, David , Ness, Brian Van, Greipp, Philip R., Kay, Neil E. , Fonseca, Rafael

Mayo Clinic

Blood | October 1, 2002 | Volume: 99 | Issue: 10 | Pages: 3735-3741

10.1182/blood.v99.10.3735 | PMID 11986230 Get It

The t(11;14)(q13;q32) results in up-regulation of cyclin D1 and is the most common translocation detected in multiple myeloma, where it is also associated with a lymphoplasmacytic morphology. We performed an interphase fluorescent in situ hybridization (FISH) study to determine the clinical and biologic significance of the abnormality when testing a large cohort of myeloma patients. Bone marrow slides from multiple myeloma patients entered into the Eastern Cooperative Oncology Group phase III clinical trial E9486 and associated laboratory correlative study E9487 were analyzed using interphase FISH combined with immune-fluorescent (cytoplasmic immunoglobulin–FISH) detection of clonal plasma cells. We used FISH probes that hybridize to the 14q32 and 11q13 chromosomal loci. The t(11;14)(q13;q32) was correlated with known biologic and prognostic factors. Of 336 evaluable patients, 53 (16%) had abnormal FISH patterns compatible with the t(11;14)(q13;q32). These patients appeared to be more likely to have a serum monoclonal protein of less than 10 g/L (1 g/dL) (28% vs 15%, P = .029) and a lower plasma cell labeling index (P = .09). More strikingly, patients were less likely to be hyperdiploid by DNA content analysis (n = 251, 14% vs 62%, P &lt; .001). Patients with the t(11;14)(q13;q32) appeared to have better survival and response to treatment, although this did not reach statistical significance. Multiple myeloma with the t(11;14)(q13;q32) is a unique subset of patients, not only characterized by cyclin D1 up-regulation and a lymphoplasmacytic morphology, but is also more frequently associated with small serum monoclonal proteins and is much less likely to be hyperdiploid. These patients do not have a worsened prognosis as previously thought.
Culture with BACTEC Peds Plus/F Bottle Compared with Conventional Methods for Detection of Bacteria in Synovial Fluid
Vetter, Emily A., Patel, Robin , Schleck, Cathy D. , Harmsen, Scott, Turgeant, L. Thomas, Cockerill, Franklin R., Hughes, John , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4468-4471

10.1128/jcm.39.12.4468-4471.2001 | PMID 11724863 Get It

ABSTRACT An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens ( n = 62), contaminants ( n = 12), or indeterminate ( n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [ P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [ P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.
Comparison of the BACTEC MYCO/F Lytic Bottle to the Isolator Tube, BACTEC Plus Aerobic F/Bottle, and BACTEC Anaerobic Lytic/10 Bottle and Comparison of the BACTEC Plus Aerobic F/Bottle to the Isolator Tube for Recovery of Bacteria, Mycobacteria, and Fungi
Vetter, Emily A., Torgerson, C A, Feuker, A., Harmsen, Scott, Schleck, Cathy D. , Horstmeier, C D, Roberts, Glenn D., Cockerill, Franklin R., Hughes, John

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4380-4386

10.1128/jcm.39.12.4380-4386.2001 | PMID 11724848 Get It

ABSTRACT The BACTEC MYCO/F Lytic blood culture bottle (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is designed to optimize the recovery of fungi and mycobacteria; however, this bottle also supports the growth of most aerobic bacteria. We compared the MYCO/F Lytic bottle with two other BACTEC bottles and the Isolator system for the recovery of bacteria as well as fungi and mycobacteria from blood. A total of 6,108 blood culture sets were inoculated with blood obtained from adult patients. Twenty-five to 28 ml of blood collected by a phlebotomy team for each blood culture set was randomly distributed into each of four blood culture receptacles: the Isolator tube (Wampole Laboratories, Cranbury, N.J.) and three BACTEC bottles: the MYCO/F Lytic bottle, the BACTEC Plus Aerobic/F bottle, and the BACTEC Anaerobic Lytic/10 bottle. The sediment from the Isolator tube was inoculated onto chocolate agar (CA), brain heart infusion agar (BHI), and Sabouraud dextrose agar (SDA) and into a BACTEC 13A bottle. Incubation durations were as follows: MYCO/F Lytic bottle, 42 days; Plus Aerobic/F bottle, 5 days; Anaerobic Lytic/10 bottle, 5 days; sediment from Isolator tube on CA, 3 days; sediment from Isolator tube on BHI, 30 days; sediment from Isolator tube on SDA, 30 days; and sediment from Isolator tube in a BACTEC 13A bottle, 42 days. Two isolates of Histoplasma capsulatum were recovered from the Isolator tube only. Three isolates of Mycobacterium tuberculosis complex were recovered: two isolates from the MYCO/F Lytic bottle only and one isolate from the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle) only. Two isolates of Cryptococcus neoformans were recovered: one from the MYCO/F Lytic bottle only and the other from the MYCO/F Lytic bottle and the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle). For potential pathogens overall, there was a statistical difference in recovery that favored the Isolator system over the MYCO/F Lytic bottle ( P = 0.0015), including statistically significant differences for Staphylococcus aureus ( P = 0.0001) and Streptococcus pneumoniae ( P = 0.0313). However, there was no statistically significant difference between the two blood culture systems when detection of bloodstream infection was considered. The time to detection for all potential pathogens combined was less for the MYCO/F Lytic bottle than for the Isolator system ( P = 0.0004). Overall, the potential pathogen recovery was greater for the BACTEC Plus Aerobic/F bottle than for either the Isolator system ( P = 0.0003) or the MYCO/F Lytic bottle ( P = 0.0001). However, the BACTEC Plus Aerobic/F bottle did not recover M. tuberculosis , H. capsulatum , or C. neoformans isolates. The combination of the Isolator system and MYCO/F Lytic bottle may be useful as a selective blood culture method to optimize the recovery of fungi and mycobacteria from blood. Compared with the manual Isolator system, the MYCO/F Lytic system has the advantage of less preanalytic processing and continuous automated monitoring of bottles for growth by the BACTEC 9240 instrument.
Direct Identification of Bacteria from Positive Blood Cultures by Amplification and Sequencing of the 16S rRNA Gene: Evaluation of BACTEC 9240 Instrument True- Positive and False-Positive Results
Qian, Qinfang, Kolbert, Christopher P., Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Montgomery, Stacy O., Cockerill, Franklin R., Persing, David H., Tang, Yi‐Wei , Hughes, John

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 10 | Pages: 3578-3582

10.1128/jcm.39.10.3578-3582.2001 | PMID 11574575 Get It

ABSTRACT In a previous study which evaluated the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.), we noted a 1.3% “instrument false-positive” rate. That is, the BACTEC system signaled that a bottle (BACTEC Plus Aerobic/F bottle or BACTEC Anaerobic Lytic/10 bottle) culture was positive but a Gram stain was negative and there was no growth of bacteria or yeasts on subculture to chocolate agar. Furthermore, from the same sample of blood, cultures for fungi using the Isolator blood culture system (Wampole Laboratories, Cranbury, N.J.) were negative for growth. For the present study, we evaluated 76 instrument false-positive samples for the presence of 16S ribosomal DNA using the MicroSeq 500 kit (PE Biosystems, Foster City, Calif.). These samples also were negative for fungi by the Isolator method. This kit has a PCR module and sequencing module for the amplification and sequencing of the 16S RNA gene and provides a database for sequence alignment and identification of bacteria. To optimize the assay, we evaluated the effect of adding 0.5% bovine serum albumin to the sample from blood culture bottles and found that it decreased the effects of inhibitors on the PCR. Two control groups of blood culture specimens were also evaluated. One group ( n = 45) were “instrument true positives”; the instrument signaled positive, and subsequent Gram stains were positive and subcultures on chocolate agar grew bacteria. The other group ( n = 20) were “instrument true negatives”; the instrument signaled negative, the Gram stain was negative, and subcultures on chocolate agar and from the Isolator tube on fungal media showed no growth. None of the 76 instrument false-positive samples had evidence for 16S rRNA gene sequences. All of the instrument true-positive samples and all of the instrument true-negative specimens were positive and negative, respectively, using the MicroSeq 500 kit. Total peripheral white blood cell counts were statistically significantly higher for patients who had instrument false-positive results than for patients who had instrument true-positive or true-negative results ( P = 0.001). We conclude that instrument false positives signaled by the BACTEC 9240 system are not due to bacteria in the blood culture samples.
Frequency of Isolation of Staphylococcus lugdunensis in Consecutive Urine Cultures and Relationship to Urinary Tract Infection
Haile, Dawit T. , Vetter, Emily A., Kohner, Peggy C., Patel, Robin , Cockerill, Franklin R., Hughes, John , Snyder, Richard V. , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 2 | Pages: 654-656

10.1128/jcm.40.2.654-656.2002 | PMID 11825988 Get It

ABSTRACT Recent reports associate Staphylococcus lugdunensis with severe infection in humans. The frequency of this microorganism in urine cultures is unknown. Five hundred isolates of coagulase-negative staphylococci (CoNS) were recovered from 4,652 consecutive urine specimens submitted for culture to the Mayo Clinic Microbiology Laboratory. Thirty-one (6%) of 500 isolates of CoNS were identified as S. lugdunensis . In no case was S. lugdunensis isolated in pure culture; 29 (94%) of 31 S. lugdunensis isolates were part of mixed nonpathogenic flora. Medical records were reviewed for 30 of the 31 patients from whom these 31 isolates were isolated. Twenty-one (70%) of the 30 evaluable patients were not treated with antibiotics; the remaining 9 (30%) of 30 patients were treated with antibiotics that may be effective against S. lugdunensis. S. lugdunensis may be an unrecognized yet infrequent cause of urinary tract infection.
Multiplex LightCycler PCR Assay for Detection and Differentiation of Bordetella pertussis and Bordetella parapertussis in Nasopharyngeal Specimens
Sloan, Lynne M., Hopkins, Marlene K., Mitchell, P. Shawn, Vetter, Emily A., Rosenblatt, Jon E., Harmsen, William S. , Cockerill, Franklin R., Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 1 | Pages: 96-100

10.1128/jcm.40.1.96-100.2002 | PMID 11773099 Get It

ABSTRACT A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS 481 and IS 1001 of B. pertussis and B. parapertussis , respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis ) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS 481 ) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens ( n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different ( P = 0.0654). The insertion sequence IS 481 is also present in Bordetella holmesii ; specimens containing B . holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B . pertussis and B . parapertussis in nasopharyngeal specimens.