Adding an extension piece to the end of the purge side arm of the Impella device can prevent the incidence of the cassette breaking and decrease the Impella device failure rate: Impact of practice change on patient outcome
Background: Impella 5.5® with Smart Assist is a minimally invasive Left Ventricular Assist Devices (LVAD) approved by the Food and Drug Administration (FDA) for treating ongoing cardiogenic shock for up to 14 days. The Impella® intends to reduce ventricular workload and provide the circulatory support necessary for myocardial recovery. Research Question: Compared to standard practice, does adding an extension piece to the purge tube side arm of the Impella® Device decrease the incidence of device failure and positively impact the health outcome of adult patients receiving Impella® support? Study Design and Methods: A retrospective chart review of ICU patients was done at a tertiary care center from August 2018 to August 2022 to assess the differences in patient outcomes related to Impella® Device utilization before and after the implementation of the extension piece to the purge tube sidearm. Among patients reviewed, a total of 20 were included in our review, with seven not having the purge tube side arm extension added, while 13 patients had the extension. Results: The two study groups had no significant difference in patient health outcomes. Additionally, there were no instances of device failure requiring explanation without the extension tubing. However, there were no cases of the purge cassette cracking with the addition of the extension tubing. Conclusion: The addition of extension tubing to the purge cassette of the Impella® Device did not impact patient health outcomes or the incidence of device failure. There was a complete reduction in the incidence of the purge cassette cracking, which could reduce the potential for infection or device failure over a long period of mechanical support. There is a need for long-term prospective studies to confirm the results.
Assessment of the Patient Experience Across All Phases of Migraine (4636)
Introduction: ISB 1342 is a humanized CD38xCD3 bispecific T-cell engager using Ichnos proprietary Bispecific Engagement by Antibodies based on the T cell receptor (BEAT ®) platform, designed to simultaneously bind CD38 on multiple myeloma (MM) cells and CD3ε on T cells, to induce tumor killing. This mechanism of action is different from existing monospecific CD38 targeting therapies and was designed to overcome resistance to daratumumab in MM. ISB 1342 exhibits potent killing of the primary MM cells and MM cell lines with low sensitivity to daratumumab ( Pouleau B. et al. Blood 2023; 142 (3): 260-273). We report here, the updated findings from the weekly dose-escalations of intravenous (IV) and subcutaneous (SC) injections of an ongoing, single-agent phase 1 study (NCT03309111) of ISB 1342 in patients with RRMM. Methods: Adult patients with RRMM that relapsed after or were refractory to prior therapies, including a proteasome inhibitor, an immunomodulatory drug, and an anti-CD38 antibody; received ISB 1342 on a weekly (QW) schedule by IV or SC injection with a priming dose on the first day in 2 parallel dose-escalation schemas. Patients had measurable disease per the International Myeloma Working Group (IMWG) criteria (2016). Dose escalation in the QW schedule began at 0.2/0.3 mg/kg priming/treatment dose and followed a “3 + 3” design. The primary study objectives are to determine the maximum tolerated dose (MTD) and select a recommended phase 2 dose (RP2D) of ISB 1342. Secondary objectives includ evaluation of anti-myeloma activity, pharmacokinetics (PK), pharmacodynamics, and immunogenicity of ISB 1342. Results: As of July 18, 2023, based on ongoing clinical database, 39 subjects had received weekly IV infusions of ISB 1342 in 8 dose-escalation groups from 0.2/0.3 mg/kg to 4.0/16.0 mg/kg as priming/treatment dose; and 7 additional subjects had received weekly SC injections at 2.0/8.0 mg/kg. Two different formulations have been tested in SC group. Median number of cycles administered was 2. The majority were male (57%) and white (74%); 13% were Black or African American. The median age was 69 years (range, 54-76) and the median time since diagnosis was 6.6 years (range, 2.8-22.2). The median number of prior anti-myeloma lines of therapy was 6 (range 1-12). Twenty-one (67%) subjects were considered to be triple-class refractory and 18 (48%) penta-drug refractory. Forty-one (89%) subjects experienced treatment-related adverse events (TRAEs) of any grade. Most TRAEs were grade 1-2, including infusion related reactions (37%), cytokine release syndrome (CRS, 34%, all grade 1or 2), anemia (24%), neutropenia (24%), and thrombocytopenia (17%). Five subjects in SC group (71% of SC) had injection site reaction, all grade 1 or 2. Grade 3 or higher TRAEs occurring in more than 5% of subjects were infusion related reaction (no grade 4), anemia (no grade 4), neutropenia, leukopenia. No Grade 5 TRAE was observed. After QW IV infusion, ISB 1342 serum concentration peaked at the end of infusion and then showed bi-exponential decline. ISB 1342 serum exposures increased in a dose linear fashion across the tested IV infusion dose range. The limited PK data after SC injection suggest slow presentation of ISB 1342 into the systemic circulation leading to lower C max and delayed T max relative to IV. Transient increases in serum cytokines were observed within 24 hours after ISB 1342 dosing, including IFNg, TNFa, IL-2, IL-6 and IL-10. Transient increases in T-cell activation were observed by flow cytometry at 24-48 hours after ISB 1342 dosing at 1.0 / 4.0 μg/kg and above, based on increased expression of CD69 on peripheral blood CD4+ and CD8+ T-cell populations (Figure 1). Comparison of the available data from subjects treated at 2 / 8 μg/kg (Cohort 109) indicated reduced T-cell activation following SC compared to IV administration of ISB 1342. The efficacy signals observed in Cohorts 108 and 109 are consistent with the estimates of the lower boundary of the predicted efficacious dose range using a quantitative systems pharmacology (QSP) model based on preclinical data. Updated clinical data, including response rates and safety data, will be present at the meeting. Conclusions: Treatment with ISB 1342 was well tolerated at higher dose levels evaluated. Observed CRS events were moderate. No increased risk of infection has been observed . Updated safety, efficacy, biomarker and PK data will be presented.
Comparing in vivo wave-based elastography with ex vivo mechanical testing in porcine vessels
Arterial stiffness predicts cardiovascular disease, the leading cause of death worldwide. Ultrasound elastography methods that measure wave velocity have promise for evaluating the stiffness of blood vessels in vivo. However, vessel geometry modulates wave velocity by inducing geometric dispersion. Here, we compare Young's modulus E estimates obtained using in vivo wave velocity measurements and techniques that either do or do not consider geometry to ex vivo reference E values from mechanical testing . An acoustic radiation force was applied to generate propagating waves in the right common carotid artery (N = 9) and external jugular vein (N = 10) of anesthetized pigs. Vessels were imaged with ultrafast ultrasound to measure wave motion. Group velocity cg was estimated from wave motion using a Radon transform. E was estimated from cg using a bulk media assumption which neglects geometry, as well as the Moens–Korteweg equation and a semi-analytical finite element model, which consider geometry. Pigs were euthanized and vessels were excised. Ring-shaped samples were extracted and tested in a uniaxial tension setup to obtain reference E values for comparison with E values obtained from wave-based techniques. Techniques considering geometry exhibited higher correlation with reference E values, underscoring the need to incorporate geometry for accurate vascular elastography assessments.