Citations

Clear

201 citation(s) found for "Lieske, John C".

Looking for a Better Creatinine
Meeusen, Jeffrey W. , Lieske, John C.

Mayo Clinic

Clinical Chemistry | February 27, 2014 | Volume: 60 | Issue: 8 | Pages: 1036-1039

10.1373/clinchem.2013.220764 | PMID 24573605 Get It

State of the Art for Measurement of Urine Albumin: Comparison of Routine Measurement Procedures to Isotope Dilution Tandem Mass Spectrometry
Bachmann, Lorin M, Nilsson, Göran , Bruns, David E., McQueen, Matthew, Zakowski, Jack, Miller, W. Greg , Lieske, John C.

Mayo Clinic

Clinical Chemistry | November 26, 2013 | Volume: 60 | Issue: 3 | Pages: 471-480

10.1373/clinchem.2013.210302 | PMID 24281781 Get It

Abstract BACKGROUND Urine albumin is the primary biomarker for detection and monitoring of kidney damage. Because fixed decision criteria are used to identify patients with increased values, we investigated if commonly used routine measurement procedures gave comparable results. METHODS Results from 17 commercially available urine albumin measurement procedures were investigated vs an isotope dilution mass spectrometry (IDMS) procedure. Nonfrozen aliquots of freshly collected urine from 332 patients with chronic kidney disease, diabetes, cardiovascular disease, and hypertension were distributed to manufacturers to perform urine albumin measurements according to the respective instructions for use for each procedure. Frozen aliquots were used for measurements by the IDMS procedure. An error model was used to determine imprecision and bias components. RESULTS Median differences between the largest positive and negative biases vs IDMS were 45%, 37%, and 42% in the concentration intervals of 12–30 mg/L, 31–200 mg/L, and 201–1064 mg/L, respectively. Biases varied with concentration for most procedures and exceeded ±10% over the concentration interval for 14 of 16 quantitative procedures. Mean biases ranged from −35% to 34% at 15 mg/L. Dilution of samples with high concentrations introduced bias for 4 procedures. The combined CV was >10% for 5 procedures. It was not possible to estimate total error due to dependence of bias on concentration. CVs for sample-specific influences were 0% to 15.2%. CONCLUSIONS Bias was the dominant source of disagreement among routine measurement procedures. Consequently, standardization efforts will improve agreement among results. Variation of bias with concentration needs to be addressed by manufacturers.
Biomarkers for Acute Kidney Injury: Where Are We Today? Where Should We Go?
Chawla, Lakhmir S. , Kellum, John A. , Mehta, Ravindra L. , Lieske, John C. , Kashani, Kianoush , Koyner, Jay L. , Mehta, Ravindra L , Kellum, John A

Mayo Clinic

Clinical Chemistry | August 19, 2013 | Volume: 60 | Issue: 2 | Pages: 294-300

10.1373/clinchem.2012.201988 | PMID 23958848 Get It

Commentary
Lieske, John C.

Mayo Clinic

Clinical Chemistry | May 29, 2013 | Volume: 59 | Issue: 6 | Pages: 890-890

10.1373/clinchem.2012.199307 | PMID 23719824 Get It

Effect of Age on the Clinical Presentation of Incident Symptomatic Urolithiasis in the General Population
Krambeck, Amy E. , Li, Xujian, Bergstralh, Eric J., Melton, L. Joseph, Lieske, John C. , Rule, Andrew D.

Mayo Clinic

Journal of Urology | November 16, 2012 | Volume: 189 | Issue: 1 | Pages: 158-164

10.1016/j.juro.2012.09.023 | PMID 23164393 Get It

Differentiation of Calcium Oxalate Monohydrate and Calcium Oxalate Dihydrate Stones Using Quantitative Morphological Information from Micro-Computerized and Clinical Computerized Tomography
Duan, Xinhui , Qu, Mingliang , Wang, Jia , Trevathan, James K. , Vrtiska, Terri J., Williams, James C. , Krambeck, Amy E. , Lieske, John C. , McCollough, Cynthia H. , Trevathan, James K

Mayo Clinic

Journal of Urology | November 7, 2012 | Volume: 189 | Issue: 6 | Pages: 2350-2356

10.1016/j.juro.2012.11.004 | PMID 23142201 Get It

Temporal Trends in Incidence of Kidney Stones Among Children: A 25-Year Population Based Study
Dwyer, Moira , Krambeck, Amy E. , Bergstralh, Eric J., Milliner, Dawn S. , Lieske, John C. , Rule, Andrew D.

Mayo Clinic

Journal of Urology | May 15, 2012 | Volume: 188 | Issue: 1 | Pages: 247-252

10.1016/j.juro.2012.03.021 | PMID 22595060 Get It

Gallotannin Suppresses Calcium Oxalate Crystal Binding and Oxalate-Induced Oxidative Stress in Renal Epithelial Cells
Jeong, Soo-Jin, Linnes, Michael , Han, Hee Jeoung, Kim, Sung‐Hoon , Lee, Hyo‐Jung , Jeong, Soo‐Jin , Park, Moon Nyeo , Kim, Jin Hyoung , Lieske, John C.

Mayo Clinic

Biological and Pharmaceutical Bulletin | April 2, 2012 | Volume: 35 | Issue: 4 | Pages: 539-544

10.1248/bpb.35.539 | PMID 22466558 Get It

Importance of Cystatin C Assay Standardization
Voskoboev, Nikolay, Larson, Timothy S., Rule, Andrew D. , Lieske, John C.

Mayo Clinic

Clinical Chemistry | June 11, 2011 | Volume: 57 | Issue: 8 | Pages: 1209-1211

10.1373/clinchem.2011.164798 | PMID 21666068 Get It

Dual-Energy Dual-Source CT With Additional Spectral Filtration Can Improve the Differentiation of Non–Uric Acid Renal Stones: An Ex Vivo Phantom Study
Qu, Mingliang , Ramírez-Giraldo, Juan Carlos , Williams, James C. , Vrtiska, Terri J., Leng, Shuai , Lieske, John C. , McCollough, Cynthia H.

Mayo Clinic

American Journal of Roentgenology | May 23, 2011 | Volume: 196 | Issue: 6 | Pages: 1279-1287

10.2214/ajr.10.5041 | PMID 21606290 Get It