Citations

Clear

212 citation(s) found for "Deng, J".

Evaluation of a Thermal-Based Flow Meter for Assessment of Mobile Resting Metabolic Rate Measures
Liu, Nai-Yuan , Deng, Yue , Tsow, Francis , Bridgeman, Devon, Dean, Jane J., Wilson, Janet, Tao, Nongjian , Kulick, Doina , Forzani, Erica , Forzani, Erica S , Xian, Xiaojun , Wilson, Janet L.

Mayo Clinic

Journal of Sensors | October 9, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-8

10.1155/2018/9186475 Get It

This work evaluates the use of a new flow meter to assess exhalation rate. A mobile indirect calorimeter (MIC) was designed and used to measure resting metabolic rate (RMR), which relies on the measure of O2 consumption rate (VO2) and CO2 production rate (VCO2). The device was produced from a commercially available and well-established indirect calorimeter and implemented with a new flow meter for the purpose of this study. VO2 and VCO2 were assessed by measuring exhalation rates using the new flow meter and O2 and CO2 concentrations in breath using the original colorimetric sensors of the indirect calorimeter. The new flow meter was based on a thermal flow meter (TFM) affixed to an orifice with a diameter of 6.8 mm used as a passage for exhaled breath from 16 subjects. The results were compared with a metabolic cart (Medical Graphics), which was connected in series to the modified device. We found that 69% of the results had more than a 10% difference between the modified MIC device and the reference instrument, suggesting that the sensitivity of the thermal flow meter changed over time, which precluded its use as a flow meter for breath flow rate measurement.
Phase 3 trial of momelotinib (MMB) vs ruxolitinib (RUX) in JAK inhibitor (JAKi) naive patients with myelofibrosis (MF).
Catalano, John, Egyed, Miklós , Hellman, Andrzei, Winton, Elliott F., Dubowy, Ronald L., Maltzman, Julia D., Cervantes, Francisco , Mesa, Ruben A. , Kiladjian, Jean‐Jacques , Devos, Timothy , McLornan, Donal P. , Shimoda, Kazuya , Deng, Wei, Gotlib, Jason

Mayo Clinic

Journal of Clinical Oncology | September 6, 2018 | Volume: 35 | Issue: 15_suppl | Pages: 7000-7000

10.1200/jco.2017.35.15_suppl.7000 Get It

7000 Background: MMB, an oral JAKi, has been shown in early trials to reduce spleen volume, improve disease associated symptoms (Sx) and improve RBC transfusion (Tx) requirements in patients (pts) with MF. This study was designed to test non-inferiority of MMB vs RUX in splenic volume reduction and Sx amelioration, and superiority in Tx requirement, in JAKi naïve MF pts. Methods: Eligibility: MF, IPSS high risk, Int-2, or symptomatic Int-1; palpable spleen ≥5cm; platelets ≥ 50 K/μl, and no Gr ≥2 peripheral neuropathy (PN). Stratification by Tx dependency and platelets (<100, 100-200 and >200 K/μl). Pts were randomized 1:1 to 24 wks of MMB 200 mg qd + RUX placebo or RUX 20 mg bid (or modified per label) + MMB placebo, after which all pts could receive open label MMB. Assessments: spleen volume by MRI, and pt reported Sx using a daily eDiary of modified MPN-SAF Total Sx Score (TSS). Primary endpoint was splenic response rate (SRR; ≥35% reduction in volume from baseline) at 24 wks. Secondary endpoints, evaluated sequentially at 24 wks, were rates of TSS response (≥50% reduction from baseline), RBC Tx independence (TI), RBC Tx dependence (TD) and of RBC Tx . Results: 175 of 215 (81%) and 201 of 217 (93%) pts randomized to MMB and RUX, respectively, completed the 24 wk DB phase. Efficacy results are shown in Table. Most common Gr ≥3 AEs in the DB phase with MMB were thrombocytopenia (7%) and anemia (6%), and with RUX were anemia (23%), thrombocytopenia (5%) and neutropenia (5%). Gr ≥3 infections occurred in 7% of MMB and 3% of RUX pts. Treatment emergent PN occurred in 22 (10%) of MMB (all Gr ≤2) and 10 (5%) of RUX (9 Gr ≤2, 1 Gr 3) pts in DB phase, none discontinuing study drug for PN. Overall, AEs led to study drug D/C in 13% of MMB and 6% of RUX pts in DB phase. Conclusions: In pts with JAKi naive MF, 24 weeks of MMB is non-inferior to RUX for spleen response but not for symptom response. MMB treatment is associated with a reduced transfusion requirement. NCT01969838. [Table: see text]
Prognostic and predictive blood-based biomarkers (BMs) in patients (pts) with advanced epithelial ovarian cancer (EOC) treated with carboplatin–paclitaxel (CP) ± bevacizumab (BEV): Results from GOG-0218.
Tritchler, David , Starr, Mark D. , Brady, John C. , Hurwitz, Herbert I. , Mannel, Robert S., Tewari, Krishnansu S. , Gray, Heidi J. , Boente, Matthew, Deng, Wei , Burger, Robert A. , Birrer, Michael J. , Secord, Angeles Alvarez , Liu, Yingmiao , Lankes, Heather A. , O’Malley, David M. , Bakkum‐Gamez, Jamie N. , Fujiwara, Keiichi , Deng, Wei, Nixon, Andrew B.

Mayo Clinic

Journal of Clinical Oncology | September 6, 2018 | Volume: 34 | Issue: 15_suppl | Pages: 5521-5521

10.1200/jco.2016.34.15_suppl.5521 Get It

Temporal lobe contusions on computed tomography are associated with impaired 6-month functional recovery after mild traumatic brain injury: a TRACK-TBI study
Yue, John K. , Winkler, Ethan A. , Puffer, Ross C. , Deng, Hansen , Wagle, Sagar, Morrissey, Molly Rose, Rivera, Ernesto J. , Runyon, Sarah J., Vassar, Mary J. , Taylor, Sabrina R. , Cnossen, Maryse C. , Lingsma, Hester F. , Yuh, Esther L. , Schnyer, David M. , Puccio, Ava M. , Valadka, Alex B. , Okonkwo, David O. , Manley, Geoffrey T. , Investigators, the TRACK-TBI, Schnyer, David M , Phelps, Ryan , Mukherjee, Pratik

Mayo Clinic

Neurological Research | September 3, 2018 | Volume: 40 | Issue: 11 | Pages: 972-981

10.1080/01616412.2018.1505416 | PMID 30175944 Get It

Expression of Signaling Molecules Involved in Embryonic Development of the Insertion Site Is Inadequate for Reformation of the Native Enthesis
Deng, Xiang‐Hua , Lebaschi, Amir , Carballo, Camila B. , Coleman, Nathan, Zong, Jianchun, Grawe, Brian M. , Rodeo, Scott A. , Rodeo, Scott A , Camp, Christopher L.

Mayo Clinic

Journal of Bone and Joint Surgery | August 1, 2018 | Volume: 100 | Issue: 15 | Pages: e102

10.2106/jbjs.16.01066 | PMID 30063598 Get It

Background: Since healing of anterior cruciate ligament (ACL) grafts occurs by formation of a fibrovascular scar-tissue interface rather than by reformation of the native fibrocartilage transition zone, the purpose of our study was to examine expression of various signaling molecules and transcription factors that are known to be involved in embryologic insertion-site development following ACL reconstruction. We also aimed to characterize a murine model of ACL reconstruction to allow future study of the molecular mechanisms of healing. Methods: Seventy-nine mice underwent reconstruction of the ACL with autograft. Healing was assessed using histology in 12 mice and quantitative real-time polymerase chain reaction (qRT-PCR) gene-expression analysis in 3 mice at 1 week postoperatively (Group-1 mice) and by biomechanical analysis in 7, histological analysis in 7, immunohistochemical analysis in 5, microcomputed tomography analysis in 5, and qRT-PCR analyses in 8 at 2 weeks (Group-2 mice) and 4 weeks (Group-3 mice) postoperatively. Fifteen additional mice did not undergo surgery and were used for biomechanical (7 mice), qRT-PCR (3 mice), and immunohistochemical (5 mice) analyses to obtain baseline data for the native ACL. Results: Histological analysis demonstrated healing by formation of fibrovascular tissue at the tendon-bone interface. Immunohistochemical analysis showed a positive expression of proteins in the Indian hedgehog, Wnt, and parathyroid hormone-related protein (PTHrP) pathways. There was minimal Sox-9 expression. Gene-expression analysis showed an initial increase in markers of tissue repair and turnover, followed by a subsequent decline. Mean failure force and stiffness of the native ACL were 5.60 N and 3.44 N/mm, respectively. Mean failure force and stiffness were 1.29 N and 2.28 N/mm, respectively, in Group 2 and were 1.79 N and 2.59 N/mm, respectively, in Group 3, with 12 of 14 failures in these study groups occurring by tunnel pull-out. Conclusions: The spatial and temporal pattern of expression of signaling molecules that direct embryologic insertion-site formation was not adequate to restore the structure and composition of the native insertion site. Clinical Relevance: Development of a murine model to study ACL reconstruction will allow the use of transgenic animals to investigate the cellular, molecular, and biomechanical aspects of tendon-to-bone healing following ACL reconstruction, ultimately suggesting methods to improve healing in patients.
DP _DETECTION: An outlier detection algorithm based on density of big data
Li, Xiaodi , Huang, Ming , Li, Dingcheng , Wang, Hongjun , Deng, Ping

Mayo Clinic

Data Science and Knowledge Engineering for Sensing Decision Support | July 31, 2018 | Volume: No volume available | Issue: No issue available | Pages: 534-544

10.1142/9789813273238_0069 Get It

Utility of Antinuclear Antibody Screening by Various Methods in a Clinical Laboratory Patient Cohort
Deng, Xiaoli , Peters, Brian E., Ettore, Michael, Ashworth, Judy, Brunelle, Lynn A, Crowson, Cynthia S. , Moder, Kevin G., Snyder, Melissa R. , Peters, Brian, Ettore, Michael W, Ashworth, Judy

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 1 | Pages: 36-46

10.1373/jalm.2016.020172 | PMID 33626797 Get It

Abstract Background Antinuclear antibody (ANA)5 testing is routinely performed during evaluation of patients with a suspected connective tissue disease (CTD), yet the question of which method is most appropriate remains controversial. The purpose of this study was to evaluate the clinical utility of ANA testing by an enzyme immunoassay (EIA), an immunofluorescence assay (IFA), and a multiplex immunoassay (MIA) in a routine laboratory population. Methods Samples (n = 1000) were collected from specimens submitted for ANA testing by EIA (Bio-Rad). All samples were subsequently analyzed by IFA (Zeus) and MIA (Bio-Rad). The sample cohort was weighted to represent the routine testing population. Diagnostic information was obtained by chart review. Results For the diagnosis of a CTD, ROC curve analysis demonstrated no significant differences between IFA (area under the curve 0.81) and EIA (0.84) (P = 0.25), with overlay of a single point for the MIA. When normalized to a specificity of approximately 90%, the sensitivities of the MIA, EIA, and IFA were 67%, 67%, and 56%, respectively. By varying the clinical cutoff, the IFA could achieve the highest sensitivity of 94%; however, the corresponding specificity was only 43%. In contrast, a strongly positive EIA had a specificity of 97%, although, at this cutoff, the sensitivity was only 40%. Conclusions Although the overall diagnostic performance of the IFA, EIA, and MIA were not statistically different, the clinical sensitivity and specificity varied dramatically based on the positive/negative cutoff. Knowledge about the performance characteristics of each method will significantly aid in the interpretation of ANA testing.
Technical Note: Using dual step wedge and 2D scintillator to achieve highly precise and robust proton range quality assurance
Robertson, Daniel , Keole, Sameer R., Shen, Jiajian , Robertson, Daniel G, Bues, Martin , Shen, Jiajian , Deng, Wei , Liu, Wei , Sio, Terence T.

Mayo Clinic

Medical Physics | May 13, 2018 | Volume: 45 | Issue: 7 | Pages: 2947-2951

10.1002/mp.12951 | PMID 29754455 Get It

PurposeThe purpose of this study was to develop a fast method for proton range quality assurance (QA) using a dual step wedge and two‐dimensional (2D) scintillator and to evaluate the robustness, sensitivity, and long‐term reproducibility of this method.MethodsAn in‐house customized dual step wedge and a 2D scintillator were developed to measure proton ranges. Proton beams with homogenous fluence were delivered through wedge, and the images captured by the scintillator were used to calculate the proton ranges by a simple trigonometric method. The range measurements of 97 energies, comprising all clinically available synchrotron energies at our facility (ranges varying from 4 to 32 cm) were repeated ten times in all four gantry rooms for range baseline values. They were then used for evaluating room‐to‐room range consistencies. The robustness to setup uncertainty was evaluated by measuring ranges with ±2 mm setup deviations in the x, y, and z directions. The long‐term reproducibility was evaluated by 1 month of daily range measurements by this method.ResultsRanges of all 97 energies were measured in less than 10 minutes including setup time. The reproducibility in a single day and daily over 1 month is within 0.1 and 0.15 mm, respectively. The method was very robust to setup uncertainty, with measured range consistencies within 0.15 mm for ±2 mm couch shifts. The method was also sensitive enough for validating range consistencies among gantry rooms and for detecting small range variations.ConclusionsThe new method of using a dual step wedge and scintillator for proton range QA was efficient, highly reproducible, and robust. This method of proton range QA was highly feasible and appealing from a workflow point of view.
A Disposable Tear Glucose Biosensor—Part 5: Improvements in Reagents and Tear Sampling Component
Lin, Chi, Ito, Yuka , Deng, Anna, Johns, Jared, Matloff, Daniel S., Sode, Koji , Belle, Jeffrey T. La , Cook, Curtiss B. , La Belle, Jeffrey T, Sode, Koji

Mayo Clinic

Journal of Diabetes Science and Technology | April 18, 2018 | Volume: 12 | Issue: 4 | Pages: 842-846

10.1177/1932296818769944 | PMID 29667855 Get It

A tear glucose (TG) sensor with an integrated tear sampler can provide a noninvasive method for calibrating the continuous TG contact lens and monitoring glucose. Expanding from previous work, an improved TG sensor that implements dried reagents, genetically modified glucose dehydrogenase (GDH), and a tear sampler was developed and compared against the TG sensor prepared with commercial GDH. It was found that neither sensor was affected by the tear interferents: ascorbic acid, acetaminophen, and uric acid. The sensor prepared with commercial GDH generated higher current. This suggests that using enzymes with lower K m may be advantageous when operating in low glucose environments like tears. The improved TG sensor also demonstrated the potential of integrating Schirmer’s test strip as a tear sampler for self-monitoring of TG.
Assessing metabolic rate and indoor air quality with passive environmental sensors
Sprowls, Mark , Deng, Yue , Kulick, Doina , Destaillats, Hugo , Forzani, Erica , Deng, Yue , Forzani, Erica S , Ruiz, Iván

Mayo Clinic

Journal of Breath Research | February 13, 2018 | Volume: 12 | Issue: 3 | Pages: 036012

10.1088/1752-7163/aaaec9 | PMID 29434055 Get It

Abstract The present work introduces the use of environmental sensors to assess indoor air quality (IAQ) in combination with human biometrics. The sensor array included temperature, relative humidity, carbon dioxide, and noise monitors. The array was used in a classroom as well as in a vehicle cabin to assess the carbon dioxide production rate of individuals in a closed ventilation environment. Analysis of carbon dioxide production allowed for the quantification of the average metabolic rate of the group of individuals in the classroom, and for one individual in the vehicle cabin. These results yielded a mere 5% difference from the values assessed using commercial metabolic rate instruments, and averaged values from epidemiological studies. The results presented in this work verify the feasibility of determining an individual’s metabolic rate using passive environmental sensors; these same sensors are able to provide a metric of IAQ that helps characterize the safety of the environment in which the individual is present.