Citations

Clear

234 citation(s) found for "Abdel, Matthew".

Vancomycin elution kinetics from porous tantalum metal
Sautet, Pierre, Mékidèche, Thibaut, Guilhaumou, Romain , Parratte, Sébastien , Ollivier, Matthieu , Abdel, Matthew P. , Argenson, Jean‐Noël

Mayo Clinic

Journal of Orthopaedic Research | October 16, 2018 | Volume: 37 | Issue: 2 | Pages: 308-312

10.1002/jor.24160 | PMID 30325073 Get It

ABSTRACTRevisions TKAs are being completed with uncemented constructs more frequently. We hypothesized that tantalum cones could be an efficient carrier of antibiotics in uncemented procedures. We aimed to compare the release of vancomycin between (i) tantalum and smooth stainless cylinders; (ii) different concentrations of vancomycin; and (iii) different durations of bathing. Specifically designed tantalum cylinders were bathed in a vancomycin solution with various durations of baths. We investigated rinses between each interval as well as the dose of vancomycin. Vancomycin concentrations were determined in each group by fluorescence polarization immunoassay at different intervals (1 h, days 1, 2, 3, 5). At 1 h, the mean vancomycin concentration for the 1‐hour soaking group was 3,172 μg/ml, whereas mean concentration for the smooth stainless steel group was 39.37 μg/ml (p < 0.001). The rinsing group showed a significantly lower concentration at 1 h and 1 day (p < 0.05). The 2‐gram vancomycin group showed no difference at days 1, 2, and 3 compared to the 1‐hour group. The 5, 15, and 30‐minute bathing groups showed significantly lower vancomycin concentrations at all‐time points. All vancomycin concentrations at day 3 were superior to the minimal inhibitory concentration of Staphyloccocus aureus. The mean concentration of vancomycin depends on the material, duration of bathing, the rinsing effect, and the drug dose. Our in‐vitro study is the first to show that porous tantalum cylinders allow antibiotic carriage and progressive release. If appearing in vivo, in a similar extent, this intrinsic property might be useful to prevent and/or treat peri‐prosthetic joint infection. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:308–312, 2019.
Two-Stage Exchange and Marlex-Mesh Reconstruction for Infection with Extensor Mechanism Disruption After Total Knee Arthroplasty
Perry, Kevin I. , Salib, Christopher G. , Larson, Dirk R. , Pagnano, Mark W. , Abdel, Matthew P. , Hanssen, Arlen D. , Abdel, Matthew P , Larson, Dirk

Mayo Clinic

Journal of Bone and Joint Surgery | September 5, 2018 | Volume: 100 | Issue: 17 | Pages: 1482-1489

10.2106/jbjs.17.01439 | PMID 30180056 Get It

Background: Periprosthetic joint infection (PJI) of the knee with concurrent disruption of the extensor mechanism is a devastating complication. Historically, knees with such complications have been salvaged with use of an arthrodesis or amputation. The purpose of this study was to assess the survival and functional outcomes of a 2-stage exchange arthroplasty combined with knitted monofilament polypropylene (Marlex; C.R. Bard) mesh reconstruction of the extensor mechanism. Methods: From 2000 to 2015, 16 patients underwent a 2-stage exchange arthroplasty and Marlex-mesh reconstruction for PJI with an extensor mechanism disruption. The study included 9 male patients and 7 female patients with a mean age at the time of reimplantation and mesh reconstruction of 64 years. The mean follow-up was 4 years. PJI was diagnosed on the basis of the Musculoskeletal Infection Society criteria. Clinical outcomes, including survivorship, Knee Society Score (KSS) results, and complications, were assessed. Results: Of 16 reconstructions, 13 were in place at the time of the latest follow-up. At 2 years, survivorship free of mesh failure was 86%, survivorship free of PJI was 87%, and survivorship free of PJI or mesh failure was 75%. The mean KSS improved from 48 prior to resection to 74 after mesh reconstruction and reimplantation. The mean extensor lag improved from 31° prior to resection to 3° after mesh reconstruction. Two patients required mesh revision, 1 patient required an above-the-knee amputation for complex wound complications related to reinfection, 1 patient developed a reinfection requiring irrigation and debridement, and 1 patient developed a superficial infection that required debridement. Conclusions: Two-stage exchange arthroplasty combined with Marlex-mesh reconstruction of the extensor mechanism is a viable alternative to knee arthrodesis or amputation. At 2 years, 75% of mesh reconstructions were in place and without evidence of PJI. Moreover, the functional outcomes were improved, with a negligible extensor lag. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Extensor Mechanism Reconstruction with Use of Marlex Mesh
Abdel, Matthew P. , Salib, Christopher G. , Mara, Kristin C. , Pagnano, Mark W. , Perry, Kevin I. , Hanssen, Arlen D. , Mara, Kristin C. , Abdel, Matthew P , Mara, Kristin C , Mara, Kristin C.

Mayo Clinic

Journal of Bone and Joint Surgery | August 1, 2018 | Volume: 100 | Issue: 15 | Pages: 1309-1318

10.2106/jbjs.17.01165 | PMID 30063593 Get It

Background: Disruption of the extensor mechanism after total knee arthroplasty (TKA) is debilitating, and the reported results of numerous reconstructive options have varied. We previously reported the early results of 13 patients who underwent reconstruction of the extensor mechanism with use of Marlex mesh. The purpose of the current study was to assess results in a larger cohort of patients, with an emphasis on the survivorship of the mesh, clinical results, and complications. Methods: During the period of 2000 to 2015 at a single tertiary care academic institution, 77 patients (77 TKAs) underwent reconstruction with use of Marlex mesh for an extensor mechanism disruption (27 quadriceps tendon disruptions, 40 patellar tendon disruptions, and 10 patellar fractures). The mean patient age at the time of reconstruction was 65 years; 70% of the patients were female. The mean body mass index was 35 kg/m 2 . The mean follow-up was 4 years. Eighteen (23%) of the patients underwent mesh reconstruction with the primary TKA in place, and 59 (77%) had mesh reconstruction at the time of revision TKA. The mean time between disruption and reconstruction was 7 months. Twenty (26%) of the patients had previously undergone attempted extensor mechanism reconstruction at outside institutions. Results: Sixty-five of the 77 mesh reconstructions were in place at the time of the latest follow-up. Twelve patients experienced a failure that required mesh revision: 5 for patellar tendon rupture, 5 for quadriceps tendon rupture, and 2 for symptomatic lengthening. Four additional patients with mesh failure were treated nonoperatively with bracing. The 2-year survivorship free of mesh revision was 86% for patients with no prior reconstruction and 95% for patients with previous reconstructions of the extensor mechanism that did not involve Marlex mesh. Knee Society Score (KSS) results significantly improved following reconstruction (p < 0.001). Extensor lag improved by a mean of 26°, with mean postoperative extensor lag measuring 9° (p < 0.001). Conclusions: Reconstruction of the extensor mechanism with use of Marlex mesh is a viable option in patients with catastrophic disruption after TKA. At the time of the latest follow-up, 84% of the mesh reconstructions were in place and the functional outcomes were excellent, with mean improvement in extensor lag of 26°. Extended follow-up is required, but the results of this large series with a mean follow-up of 4 years are encouraging. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
A randomized controlled trial of fixed- versus mobile-bearing total knee arthroplasty
Tibbo, Meagan E. , Trousdale, R T, Hanssen, Arlen D. , Pagnano, Mark W. , Abdel, Matthew P. , Stuart, Michael J.

Mayo Clinic

The Bone & Joint Journal | June 29, 2018 | Volume: 100-B | Issue: 7 | Pages: 925-929

10.1302/0301-620x.100b7.bjj-2017-1473.r1 | PMID 29954199 Get It

AimsIt has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively.Patients and MethodsA total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4).ResultsThere was no difference in durability, as measured by survivorship free of revision for any reason, nor in mean maximal ROM at ten years (p = 0.8). There was also no difference in function, as measured by Knee Society (KS) function scores (p = 0.63) or the prevalence of patellar tilt (p = 0.12).ConclusionIn this clinical RCT, the mobile-bearing design of TKA was found to be reliable and durable, but did not provide better maximum knee flexion, function or durability ten years postoperatively compared with a posterior-stabilized, fixed-bearing design incorporating either an all-polyethylene or a modular-metal-backed tibial component. Cite this article: Bone Joint J 2018;100-B:925–9.
Intravenous Versus Topical Tranexamic Acid in Total Knee Arthroplasty
Abdel, Matthew P. , Taunton, Michael J. , Pagnano, Mark W. , Trousdale, Robert T. , Lee, Yuo-yu, Su, Edwin P. , Haas, Steven B., Figgie, Mark P. , Mayman, David J. , Chalmers, Brian P. , Abdel, Matthew P , Taunton, Michael J , Sierra, Rafael J. , Lee, Yuo-yu , Boettner, Friedrich

Mayo Clinic

Journal of Bone and Joint Surgery | June 20, 2018 | Volume: 100 | Issue: 12 | Pages: 1023-1029

10.2106/jbjs.17.00908 | PMID 29916929 Get It

Background: Tranexamic acid (TXA) reduces bleeding and the need for transfusion after total knee arthroplasty. Most literature has focused on intravenous (IV) administration of TXA, with less data available on the efficacy of topically administered TXA. This multicenter randomized clinical trial specifically assessed the efficacy of topical TXA compared with IV TXA as measured by calculated blood loss, drain output, and transfusion rates. Complications, including venous thromboembolism (VTE), were reported. Methods: A total of 640 patients who underwent primary unilateral total knee arthroplasty for osteoarthritis at 2 large academic centers were randomized to receive 1 g of IV TXA prior to tourniquet inflation and 1 g at closure, or 3 g of TXA diluted in 45 mL of normal saline solution (total volume of 75 mL) and topically applied after cementation. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, and preoperative hemoglobin level were similar between the groups. Univariate, multiple linear regression, and multiple logistic regression analyses were performed. Results: Patients who received topical TXA had significantly greater calculated blood loss compared with those who received IV TXA (mean of 324 compared with 271 mL; p = 0.005). Drain output was significantly higher in the topical TXA group compared with the IV TXA group (mean of 560 compared with 456 mL; p < 0.0001). The rate of transfusion was low in the topical and IV groups, with no significant difference on univariate analysis (1.6% compared with 0.6%, respectively; p = 0.45); however, on multiple logistic regression analysis, patients who received topical TXA were 2.2-fold more likely to receive a transfusion (p < 0.0001). The topical and IV TXA groups did not differ significantly with respect to the rate of thrombotic events (0.6% compared with 1.6%, respectively; p = 0.45). Conclusions: In this large, randomized clinical trial involving patients undergoing total knee arthroplasty, both IV and topical TXA were associated with a low rate of transfusion. While IV TXA was associated with less calculated blood loss, lower drain output, and fewer transfusions, the small differences between the groups may not be clinically important. Given the low prevalence of thrombotic complications, the relative safety of one formulation of TXA over the other cannot be definitely established. Level of Evidence: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Joint contracture is reduced by intra‐articular implantation of rosiglitazone‐loaded hydrogels in a rabbit model of arthrofibrosis
Arsoy, Diren , Salib, Christopher G. , Trousdale, William H. , Tibbo, Meagan E. , Limberg, Afton K. , Lewallen, Eric A. , Reina, Nicolas , Yaszemski, Michael J. , Berry, Daniel J., Wijnen, André J. van , Berry, Daniel J. , Viste, Anthony , Reina, Nicolas , Sanchez-Sotelo, Joaquin, van Wijnen, Andre J , Berry, Daniel J , Berry, Daniel J., Morrey, Mark E. , Sánchez‐Sotelo, Joaquín , Abdel, Matthew P.

Mayo Clinic

Journal of Orthopaedic Research | June 14, 2018 | Volume: 36 | Issue: 11 | Pages: 2949-2955

10.1002/jor.24068 | PMID 29901247 Get It

ABSTRACTTrauma, surgery, and other inflammatory conditions can lead to debilitating joint contractures. Adjunct pharmacologic modalities may permit clinical prevention and treatment of recalcitrant joint contractures. We investigated the therapeutic potential of rosiglitazone by intra‐articular delivery via oligo[poly(ethylene glycol)fumarate] (OPF) hydrogels in an established rabbit model of arthrofibrosis. OPF hydrogels loaded with rosiglitazone were characterized for drug elution properties upon soaking in minimum essential media (MEM) with 10% fetal bovine serum and measurements of drug concentrations via High Performance Liquid Chromatography (HPLC). Drug‐loaded scaffolds were surgically implanted into 24 skeletally mature female New Zealand White rabbits that were divided into equal groups receiving OPF hydrogels loaded with rosiglitazone (1.67 mg), or vehicle control (10 µl DMSO). After 8 weeks of joint immobilization, rabbits were allowed unrestricted cage activity for 16 weeks. Contracture angles of rabbit limbs treated with rosiglitazone showed statistically significant improvements in flexion compared to control animals (mean angles, respectively, 64.4° vs. 53.3°, p < 0.03). At time of sacrifice (week 24), animals in the rosiglitazone group continued to exhibit less joint contracture than controls (119.0° vs. 99.5°, p = 0.014). The intra‐articular delivery of rosiglitazone using implanted OPF hydrogels decreases flexion contractures in a rabbit model of arthrofibrosis without causing adverse effects (e.g., gross inflammation or arthritis). Statement of Clinical Significance: Post‐traumatic joint contractures are common and debilitating, with limited available treatment options. Pharmacologic interventions can potentially prevent and treat such contractures. This study is translational in that a commercially approved medication has been repurposed through a novel delivery device. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2949–2955, 2018.
Direct Detection and Identification of Prosthetic Joint Infection Pathogens in Synovial Fluid by Metagenomic Shotgun Sequencing
Ivy, Morgan I. , Thoendel, Matthew , Jeraldo, Patricio , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Yao, Janet , Tande, Aaron J. , Mandrekar, Jayawant N. , Patel, Robin , Thoendel, Matthew J, Jeraldo, Patricio R , Chia, Nicholas , Yao, Janet Z, Patel, Robin , Tande, Aaron , Abdel, Matthew P. , Chia, Nicholas , Thoendel, Matthew J

Mayo Clinic

Journal of Clinical Microbiology | May 31, 2018 | Volume: 56 | Issue: 9 | Pages: No page available

10.1128/jcm.00402-18 | PMID 29848568 Get It

Metagenomic shotgun sequencing has the potential to transform how serious infections are diagnosed by offering universal, culture-free pathogen detection. This may be especially advantageous for microbial diagnosis of prosthetic joint infection (PJI) by synovial fluid analysis since synovial fluid cultures are not universally positive and since synovial fluid is easily obtained preoperatively.
Peer-to-Peer Collaboration Adds Value for Surgical Colleagues
Elbuluk, Ameer M. , Ast, Michael P. , Stimac, Jeffrey D., Banka, Trevor R., Vigdorchik, Jonathan M. , Vigdorchik, Jonathan M , Abdel, Matthew P.

Mayo Clinic

HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery | May 21, 2018 | Volume: 14 | Issue: 3 | Pages: 294-298

10.1007/s11420-018-9616-6 | PMID 30258335 Get It

Background Peer-to-peer advisory among colleagues in orthopedic surgery is commonplace in academic medical centers. In the private practice setting, however, it becomes more difficult for surgeons to discuss complex cases among peers. Purpose/Questions We sought to study the effect of peer-to-peer mentorship on surgeons’ decision-making and on patient care across academic and private adult joint reconstruction practices via the use of group secured messages. Methods From 2013 to 2016, we established a messaging system that was compliant with the Health Insurance Portability and Accountability Act (HIPAA) among five previous adult hip and knee reconstruction co-fellows in order to discuss complex cases. Data collected from each case included patient demographics (age and sex), history and physical examination, relevant imaging in orthogonal planes, and preliminary diagnosis and treatment plans. Data collected from group responses included nature of additional inquiries, literature citations, operative recommendations, and sample imaging of similar cases previously treated. Results The group consisted of two private practice surgeons and three academic surgeons. Data was collected on 283 cases discussed during the study period. None of the patients had any HIPAA violations. The mean number of reviewers who commented on a case was 2.4, with at least one response in 97% of cases. In 33% of the cases, the peers confirmed the initial treatment plan, and in 67% of the cases, an alternative treatment plan was recommended and executed. The case distribution was 94 primary and 189 revision procedures, including 173 hips, 103 knees, three ankles, two shoulders, and two pelvises. Conclusion In the majority of cases exchanged between young surgeons via a group messaging system, a significant impact on patient care was appreciated. In a technology-driven era, peer-to-peer advisory for difficult cases via a rapid feedback method may allow for substantial improvement in patient care, particularly for surgeons not practicing at a large academic medical center with access to several partners and multiple opinions.
Comparison of Diagnostic Accuracy of Periprosthetic Tissue Culture in Blood Culture Bottles to That of Prosthesis Sonication Fluid Culture for Diagnosis of Prosthetic Joint Infection (PJI) by Use of Bayesian Latent Class Modeling and IDSA PJI Criteria for
Yan, Qun , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Osmon, Douglas R. , Patel, Robin , Patel, Robin , Abdel, Matthew P.

Mayo Clinic

Journal of Clinical Microbiology | April 10, 2018 | Volume: 56 | Issue: 6 | Pages: No page available

10.1128/jcm.00319-18 | PMID 29643202 Get It

ABSTRACT We have previously demonstrated that culturing periprosthetic tissue in blood culture bottles (BCBs) improves sensitivity compared to conventional agar and broth culture methods for diagnosis of prosthetic joint infection (PJI). We have also shown that prosthesis sonication culture improves sensitivity compared to periprosthetic tissue culture using conventional agar and broth methods. The purpose of this study was to compare the diagnostic accuracy of tissue culture in BCBs (subsequently referred to as tissue culture) to prosthesis sonication culture (subsequently referred to as sonicate fluid culture). We studied 229 subjects who underwent arthroplasty revision or resection surgery between March 2016 and October 2017 at Mayo Clinic in Rochester, Minnesota. Using the Infectious Diseases Society of America (IDSA) PJI diagnostic criteria (omitting culture criteria) as the gold standard, the sensitivity of tissue culture was similar to that of the sonicate fluid culture (66.4% versus 73.1%, P = 0.07) but was significantly lower than that of the two tests combined (66.4% versus 76.9%, P < 0.001). Using Bayesian latent class modeling, which assumes no gold standard for PJI diagnosis, the sensitivity of tissue culture was slightly lower than that of sonicate fluid culture (86.3% versus 88.7%) and much lower than that of the two tests combined (86.3% versus 99.1%). In conclusion, tissue culture in BCBs reached sensitivity similar to that of prosthesis sonicate fluid culture for diagnosis of PJI, but the two tests combined had the highest sensitivity without compromising specificity. The combination of tissue culture in BCBs and sonicate fluid culture is recommended to achieve the highest level of microbiological diagnosis of PJI.