Citations

Clear

188 citation(s) found for "Kadirvel, Ramanathan".

Abstract TP54: Machine-Learned Characterization of Acute Ischemic Stroke Clots Reveals a Correlation Between Clot Composition and Density on CT
Wang, Shunli , Murphree, Dennis H. , Douglas, Andrew , Kadirvel, Ramanathan , Brinjikji, Waleed , Kallmes, David F. , Karen, Doyle M, Fitzgerald, Seán , Dai, Daying , Pandit, Abhay

Mayo Clinic

Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available

10.1161/str.49.suppl_1.tp54 Get It

Introduction: The composition of acute ischemic stroke (AIS) blood clots can impact their successful removal via endovascular therapy. Identification of the clot composition prior to endovascular treatment may influence the optimal treatment strategy. In this study, we aimed to investigate the relationship between the Hounsfield Unit intensity on CT and machine-learned characterization of clot composition. Methods: Prior to endovascular treatment, each patient had a non-contrast CT performed. Histopathological analysis of the clots was performed and clot composition was quantified via standard thresholding techniques using Adobe Photoshop. In addition, following representative cell labeling by an expert pathologist, image segmentation algorithms (Orbital Image Analysis, Actelion Ltd.) were trained on each case to quantify composition by cell type. The clots were categorized into 3 groups: red blood cell (RBC) dominant (>50%), RBC proportion equal to fibrin and fibrin dominant (>50%). Correlations between clot composition and Hounsfield Units (HU) density on CT were assessed. A positive Hyperdense Artery Sign was defined as ≥50 HU. Results: Twenty patients were included in the study. There was a significant correlation between clots quantified using Adobe Photoshop Image-Pro and Orbit image analysis ( ρ = 0.837, p < 0.001). A significant relationship was found between clot composition and the presence of a HAS sign, ( X 2 (2) = 6.496, p = 0.039). There is a significant positive correlation between percentage of RBC in the clot and the presence of a HAS sign ( ρ = 0.632, p = 0.002**). There is also a significant positive correlation between the presence of fibrin-rich and the absence of a HAS sign ( ρ = 0.600, p = 0.004**). Conclusion: Machine learning software can accurately quantify AIS clot composition. The Hounsfield unit density of an AIS clot on a non-contrast CT correlates with the composition of the clot. Measuring the HU of the clot on CT prior to endovascular intervention may inform the clinician of the clot type and help to determine the most appropriate treatment strategy for that clot.
Hemodynamic characteristics of stable and unstable vertebrobasilar dolichoectatic and fusiform aneurysms
Brinjikji, Waleed , Chung, BongJae, Yong-Hong, Ding, Wald, John T. , Mut, Fernando , Kadirvel, Ramanathan , Kallmes, David F. , Rouchaud, Aymeric , Yong-Hong, Ding, Lanzino, Giuseppe , Cebral, Juan R. , Rouchaud, Aymeric

Mayo Clinic

Journal of NeuroInterventional Surgery | March 16, 2018 | Volume: 10 | Issue: 11 | Pages: 1102-1107

10.1136/neurintsurg-2018-013756 | PMID 29549120 Get It

Background and purpose Vertebrobasilar dolichoectatic and fusiform aneurysms (VBDAs) are known to have a poor natural history, with high rates of growth, rupture, and stroke. The purpose of this study was to identify hemodynamic characteristics that differ between VBDAs associated with growth, rupture, and stroke. Materials and methods VBDAs with CT angiography or MR angiography followed longitudinally without treatment were studied. Unstable aneurysms were defined as those that grew or ruptured during follow-up. Aneurysms associated with stroke were defined as those associated with posterior circulation infarct at follow-up. Baseline data, including demographics, comorbidities, and aneurysm morphology and size were collected. Image based computational fluid dynamics models were created and run under pulsatile flow conditions. Relevant hemodynamic and geometric variables were calculated and compared between groups (stable vs unstable and no stroke vs stroke) using the Wilcoxon test. Results A total of 37 VBDAs were included (24 stable, 13 unstable; 30 no stroke, 7 stroke). Unstable aneurysms had lower shear rates (P=0.05), blood flow velocity (P=0.03), and lower vorticity (P=0.049) than stable aneurysms. In addition, unstable aneurysms had higher mean oscillatory shear indices (P=0.001). There were no differences in the hemodynamic characteristics of aneurysms in the stroke group compared with the non-stroke group. Conclusion This small study suggests there may be hemodynamic differences between unstable and stable VBDAs. Unstable VBDAs appear to be under lower flow conditions with lower velocity, vorticity, and shear rates, and have more oscillatory flow. There was no difference in the hemodynamic characteristics of aneurysms in the stroke and no stroke group.
Assessment of endothelialization of aneurysm wall over time in a rabbit model through CD31 scoring
Parameswaran, Praveen Kolumam, Ding, Yong-Hong, Gunderson, Tina M. , Kallmes, David F. , Kadirvel, Ramanathan , Kolumam Parameswaran, Praveen, Dai, Daying , Gunderson, Tina, Ding, Yonghong

Mayo Clinic

Journal of NeuroInterventional Surgery | December 29, 2017 | Volume: 10 | Issue: 9 | Pages: 888-891

10.1136/neurintsurg-2017-013381 | PMID 29288193 Get It

Background Intracranial aneurysms represent a significant health concern and are poorly understood despite decades of research. Our study focused on understanding temporal patterns of endothelial cell distribution in different spatial locations within the aneurysm early after creation in a rabbit model. Methods Elastase induced saccular aneurysms were created in rabbits and harvested on day 1 (n=3) and after 2 (n=5), 4 (n=4), 8 (n=5), and 12 (n=6) weeks. Sham operated controls (n=3) were harvested on the same day. Aneurysm and control tissue samples were subjected to en face whole mount CD31 staining for endothelial cells. Semiquantitative scoring was performed on the basis of endothelial coverage of the vessel wall (proximal, middle, and distal portions of the aneurysm dome). Mixed effects models were used to assess the effect of time and aneurysm section on endothelial coverage. Results Aneurysmal segments were near completely de-endothelialized at 4 and 8 weeks but had re-endothelialized by 12 weeks. Compared with controls, aneurysms at all time points showed decreased endothelialization, but the difference was only significant compared with the 4 and 8 week groups. Both time (P=0.03) and aneurysm section (P=0.07) were significantly associated with the degree of endothelialization. Proximal locations showed increased endothelialization compared with distal locations (P=0.03). Conclusion In experimental aneurysms of rabbits, endothelial cells regress during the first month after creation, followed by ascending re-endothelialization that stays incomplete. These findings suggest that re-population of endothelial cells comes from resident cells in the adjacent parent artery and that deranged hemodynamics may affect full reconstitution of endothelial cells long term.
Increased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs
Nash, Landon D., Monroe, Mary, Ding, Yong-Hong, Ezell, Kendal P., Boyle, Anthony, Kadirvel, Ramanathan , Kallmes, David F. , Maitland, Duncan J. , Ding, Yonghong

Mayo Clinic

Polymers | August 21, 2017 | Volume: 9 | Issue: 8 | Pages: 381

10.3390/polym9080381 | PMID 30034862 Get It

Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
Comparison of Gadolinium Concentrations within Multiple Rat Organs after Intravenous Administration of Linear versus Macrocyclic Gadolinium Chelates
McDonald, Robert J. , Schroeder, Dana , Jentoft, Mark E. , Murray, David , Kadirvel, Ramanathan , Eckel, Laurence J. , Kallmes, David F. , Dai, Daying , Murray, David L., McDonald, Jennifer S.

Mayo Clinic

Radiology | June 22, 2017 | Volume: 285 | Issue: 2 | Pages: 536-545

10.1148/radiol.2017161594 | PMID 28640692 Get It

Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
Brinjikji, Waleed , Michalak, Gregory J. , Kadirvel, Ramanathan , Gilvarry, Michael , Duffy, Sharon , Kallmes, David F. , Dai, Daying , McCollough, Cynthia, McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189 Get It

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.
Autologous adipose-derived mesenchymal stem cells improve healing of coiled experimental saccular aneurysms: an angiographic and histopathological study
Rouchaud, Aymeric , Brinjikji, Waleed , Ding, Yong-Hong, Gunderson, Tina M. , Schroeder, Dana , Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Gunderson, Tina, Spelle, Laurent , Rouchaud, Aymeric

Mayo Clinic

Journal of NeuroInterventional Surgery | January 11, 2017 | Volume: 10 | Issue: 1 | Pages: 60-65

10.1136/neurintsurg-2016-012867 | PMID 28077523 Get It

Purpose Long-term occlusion of coiled aneurysms frequently fails, probably because of poor intrasaccular healing and inadequate endothelialization across the aneurysm neck. The purpose of this study was to determine if attachment of autologous mesenchymal stem cells (MSCs) to platinum coils would improve the healing response in an elastase-induced aneurysm model in rabbits. Materials and methods With approval from the institutional animal care and use committee, aneurysms were created in rabbits and embolized with control platinum coils (Axium; Medtronic) (n=6) or coils seeded ex vivo with autologous adipose-tissue MSCs (n=7). Aneurysmal occlusion after embolization was evaluated at 1 month with angiography. Histological samples were analyzed by gross imaging and graded on the basis of neck and dome healing on H&E staining. Fibrosis was evaluated using a ratio of the total area presenting collagen. Endothelialization of the neck was quantitatively analyzed using CD31 immunohistochemistry. χ2 and Student's t-test were used to compare groups. Results Healing score (11.5 vs 8.0, p=0.019), fibrosis ratio (10.3 vs 0.13, p=0.006) and endothelialization (902 262 μm2 vs 31 810 μm2, p=0.041) were significantly greater in the MSC group. The MSC group showed marked cellular proliferation and thrombus organization, with a continuous membrane bridging the neck of the aneurysm. Angiographic stable or progressive occlusion rate was significantly lower in the MSC group (0.00, 95% CI 0.00 to 0.41) compared with controls (0.67, 95% CI 0.22 to 0.96) (p=0.02). Conclusions Autologous MSCs attached to platinum coils significantly improve histological healing, as they result in improved neck endothelialization and collagen matrix formation within the aneurysm sac.
Concomitant aneurysm detection in an intracranial dolichoectasia mouse model using a MicroFil polymer perfusion technique
Zhu, Yue-Qi, Dai, Da-Ying, Xing, H , Ding, Yong-Hong, Kadirvel, Ramanathan , Kallmes, David F. , Xing, Hai-Xia, Zhu, Yue-Qi, Dai, Daying , Ding, Yonghong

Mayo Clinic

Journal of NeuroInterventional Surgery | July 5, 2016 | Volume: 9 | Issue: 8 | Pages: 783-786

10.1136/neurintsurg-2016-012469 | PMID 27382123 Get It

Objective To assess the feasibility of using MicroFil polymer perfusion to detect concomitant saccular aneurysms in an intracranial arterial dolichoectasia (IADE) model in mice, and to report detailed histomorphometric features of these aneurysms. Materials and methods IADE models were created in C57/BL6 mice via microsurgical injection of 25 mU elastase into the cisterna magna. The cerebral vasculature was perfused with MicroFil polymer and harvested at 1, 3, and 7 days, and 2 and 4 weeks (n=8 for each group). IADE was defined by a tortuosity index >10 combined with a 25% increase in diameter of the A1 segment of the anterior cerebral artery (ACA), internal carotid artery (ICA), or basilar artery compared with the baseline of controls, which received heat-inactivated elastase. Saccular aneurysm occurrence rate, location, and morphological parameters were investigated using macroscopic and microscopic analysis. Results IADE was present in 95% (36/38) of the subjects, with a mortality rate of 5% (2/40). Fifteen concomitant saccular aneurysms were detected in 8 (21%) of the 38 surviving mice, including 6 at the posterior communicating artery, 1 along the ACA, 2 along the anterior communicating artery complex, 3 along the ICA, and 3 along the middle cerebral artery. Rupture was confirmed in two aneurysms. Histological examination indicated that the aneurysms develop via arterial-wall remodelling, which is characterized by internal elastic lamina disruptions and muscular layer discontinuity in the media. Conclusions The proportion of subjects developing saccular aneurysms in addition to IADE in our mouse model is similar to the 15% of patients with IADE who have concomitant saccular aneurysms.
P-027 statin use is associated with reduced aneurysm recurrence in small and medium sized ruptured aneurysms
Brinjikji, Waleed , Shahi, Varun, Cloft, Harry J. , Kallmes, D, Kadirvel, Ramanathan , Lanzino, Giuseppe

Mayo Clinic

Oral poster abstracts | June 8, 2016 | Volume: No volume available | Issue: No issue available | Pages: A36.1-A36

10.1136/neurintsurg-2015-011917.66 Get It

O-023 experimental testing of new generation of woven endobridge devices in elastase-induced aneurysms in rabbits
Schroeder, Dana , Kadirvel, Ramanathan , Kallmes, D, Ding, Yonghong , Dai, Daying

Mayo Clinic

Oral abstracts | June 8, 2016 | Volume: No volume available | Issue: No issue available | Pages: A12-A12

10.1136/neurintsurg-2015-011917.23 Get It