Citations

Clear

168 citation(s) found for "Cha, Yong‐Mei".

Outcomes of Lead Revision for Myocardial Perforation After Cardiac Implantable Electronic Device Placement
Huang, Xinmiao , Fu, Hai‐Xia , Zhong, Li , Osborn, Michael J., Asirvatham, Samuel J. , Sinak, Lawrence J., Cao, Jiang, Friedman, Paul A. , Cha, Yong‐Mei , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | May 26, 2014 | Volume: 25 | Issue: 10 | Pages: 1119-1124

10.1111/jce.12457 | PMID 24863054 Get It

Percutaneous Lead Revision for Cardiac PerforationIntroductionCardiac perforation is an infrequent but potentially life‐threatening complication associated with placement of a cardiac implantable electronic device (CIED). The objective of this study was to determine the outcomes of percutaneous lead revision in patients who had lead perforation of the myocardium after CIED placement.Methods and ResultsWe reviewed records of 1,458 patients who underwent CIED lead extraction or repositioning. Of these, 31 (2.1%) had the procedure performed for lead perforation as a complication of CIED placement. Demographic, clinical, and follow‐up characteristics of the patients were analyzed. Mean (SD) patient age was 65 (23) years. Cardiac perforation was detected within 24 hours after implantation in 9 patients, within 1 month in 17, and greater than 1 month in 5. Pericardiocentesis was performed with a pigtail drainage catheter in place before the lead revision in 17 patients (55%) who had pericardial effusion, with or without hemodynamic compromise. All culprit leads were successfully managed with percutaneous lead removal (n = 3 [10%]), new lead placement (n = 12 [38%]), or lead repositioning (n = 16 [52%]). Of the 17 patients with pericardiocentesis before the reoperation, none had tamponade develop; in contrast, 3 of the remaining 14 patients had tamponade develop and required urgent pericardiocentesis. All patients survived without requiring open chest surgery.ConclusionPercutaneous removal or repositioning of the perforating lead is feasible and appears effective. Placement of a prophylactic pericardial drain catheter may reduce the incidence of urgent pericardiocentesis during or after a procedure.
Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads
Higgins, John V., Gard, Joseph J., Espinosa, Raúl E. , Wood, Christopher P. , Felmlee, Joel P. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Dalzell, Connie, Acker, Nancy, Watson, Robert E. , Friedman, Paul A. , Sheldon, Seth H. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591 Get It

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Hu, Tiffany , Ebrille, Elisa , Syed, Faisal F. , Vaidya, Vaibhav R. , Cha, Yong‐Mei , Valverde, Arturo M. , Friedman, Paul A. , Suri, Rakesh M. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975

10.1111/jce.12439 | PMID 24758402 Get It

Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Performance of an Automatic Arrhythmia Classification Algorithm: Comparison to the ALTITUDE Electrophysiologist Panel Adjudications
Mahajan, Deepa, Dong, Yanting , Saxon, Leslie A. , Cha, Yong‐Mei , Gilliam, F. Roosevelt, Asirvatham, Samuel J. , Cesario, David A., Jones, Paul W. , Seth, Milan, Powell, Brian D. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | February 17, 2014 | Volume: 37 | Issue: 7 | Pages: 889-899

10.1111/pace.12367 | PMID 24527748 Get It

IntroductionAdjudication of thousands of implantable cardioverter defibrillator (ICD)‐treated arrhythmia episodes is labor intensive and, as a result, is most often left undone. The objective of this study was to evaluate an automatic classification algorithm for adjudication of ICD‐treated arrhythmia episodes.MethodsThe algorithm uses a machine learning algorithm and was developed using 776 arrhythmia episodes. The algorithm was validated on 131 dual‐chamber ICD shock episodes from 127 patients adjudicated by seven electrophysiologists (EPs). Episodes were classified by panel consensus as ventricular tachycardia/ventricular fibrillation (VT/VF) or non‐VT/VF, with the resulting classifications used as the reference. Subsequently, each episode electrogram (EGM) data was randomly assigned to three EPs without the atrial lead information, and to three EPs with the atrial lead information. Those episodes were also classified by the automatic algorithm with and without atrial information. Agreement with the reference was compared between the three EPs consensus group and the algorithm.ResultsThe overall agreement with the reference was similar between three‐EP consensus and the algorithm for both with atrial EGM (94% vs 95%, P = 0.87) and without atrial EGM (90% vs 91%, P = 0.91). The odds of accurate adjudication, after adjusting for covariates, did not significantly differ between the algorithm and EP consensus (odds ratio 1.02, 95% confidence interval: 0.97–1.06).ConclusionsThis algorithm performs at a level comparable to an EP panel in the adjudication of arrhythmia episodes treated by both dual‐ and single‐chamber ICDs. This type of algorithm has the potential for automated analysis of clinical ICD episodes, and adjudication of EGMs for research studies and quality analyses.
Distinguishing Ventricular Arrhythmia Originating from the Right Coronary Cusp, Peripulmonic Valve Area, and the Right Ventricular Outflow Tract: Utility of Lead I
Ebrille, Elisa , Chandra, Vishnu , Syed, Faisal F. , Muñoz, Freddy Del Carpio, Nanda, Sudip , Hai, Jo Jo , Cha, Yong‐Mei , Friedman, Paul A. , Hammill, Stephen C., Munger, Thomas M. , Venkatachalam, K, Packer, Douglas L. , Asirvatham, Samuel J. , Syed, Faisal, Del Carpio Munoz, Freddy, Munoz, Freddy Del‐Carpio , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 25, 2013 | Volume: 25 | Issue: 4 | Pages: 404-410

10.1111/jce.12330 | PMID 24806530 Get It

ECG Lead I and Outflow Tract ArrhythmiaIntroductionOutflow tract ventricular arrhythmia (OTVA) can be complicated to target for ablation when originating from either the periaortic or pulmonary valve (PV) region. Both sites may present with a small R wave in lead V1. However, the utility of lead I in distinguishing these arrhythmia locations is unknown.Methods and ResultsThirty‐six consecutive patients (mean age 41 ± 14 years, 13 male) underwent catheter ablation for OTVA. OTVA origin was determined from intracardiac electrogram tracings and electroanatomic maps. Observers blinded to results measured QRS waveform amplitude and duration from standard 12‐lead ECG tracings. Measurements with highest diagnostic performance were modeled into an algorithm. Sites of successful ablation were anterior right ventricular outflow tract (RVOT; n = 6), posterior RVOT (n = 4), PV (n = 18), and right coronary cusp (RCC; n = 8). Highest performing surface ECG discriminators were from lead I to V1 vectors: RCC, lead I R wave ≥ 1.5 mV, and V1 R wave ≥2.0 mV (sensitivity 87%, specificity 93%); PV, V1 R wave > 0 mV, and lead I R/(R+S) ≤ 0.75 (sensitivity 78%, specificity 72%); anterior RVOT, V1 R wave = 0 mV, and lead I R/(R+S) <0.4 (sensitivity 67%, specificity 97%); posterior RVOT, V1 R wave > 0 mV, and lead I R/(R+S) > 0.75 (sensitivity 75%, specificity 84%). Sequential algorithmic application of these criteria resulted in an overall accuracy of 72% in predicting site of OTVA origin.ConclusionsA relatively large R wave in lead I is seen with RCC origin but not PV origin. A sequential algorithm has limited but potentially significant value beyond assessment of lead I in approaching OTVA.
e0624 The effect of cardiac resynchronisation therapy on novel neurohormones in heart failure
Dong, Yun-xu, Burnett, J.C., Chen, H. H., Sandberg, S. M., Zhang, Yanhua, Chen, P.-S., Cha, Yong‐Mei , Sandberg, Sharon M., Zhang, Yanhua

Mayo Clinic

Heart | September 12, 2013 | Volume: 96 | Issue: Suppl 3 | Pages: A192.3-A192

10.1136/hrt.2010.208967.624 Get It

Background Neurohormonal dysregulation contributes to heart failure (HF) progression. We sought to determine the effect of cardiac resynchronisation therapy (CRT) on the nerve growth factor (NGF), a biomarker that promotes the maturation, and survival of sympathetic nerve endings, and amino-terminal propeptide of type III procollagen (PIIINP), a marker of type III collagen synthesis. Methods This prospective study enrolled 20 healthy age-matched controls and 45 consecutive patients (pts) who received CRT-D. NYHA class, distance of 6-min walk and echocardiography and plasma concentrations of NGF, PIIINP, b-type natriuretic peptide (BNP), norepinephrine (NE), epinephrine (EPI) and dopamine (DA) were measured before and 6 month after CRT. Response to CRT was defined as ≥15% reduction in left ventricular end-systolic volume index (LVESVI) at 6-month follow-up. Results The baseline BNP (557±692 vs 47±35, p<0.01) and PIIINP (8.22±3.76 vs 5.36±1.47, p<0.01) were elevated in HF compared to controls, while NGF, NE, EPI and DA levels were not different. Twenty two of 45 pts (49%) responded to CRT. The responder group demonstrated significant decrease only in BNP level (p=0.04) at 6-month follow-up, parallelling with the clinical improvements (table 1). The baseline PIIINP was lower in CRT responders than non-responders (p=0.04), and it correlated with the reduction of LVESVI (p=0.01, r=−0.50) after CRT. The further multivariate analysis showed only the plasma PIIINP level among clinic characters and all the biomarkers can predict the improvement of LVESV index (OR=8.33, P=0.01). Conclusion The low PIIINP level, which is consistent with possible less cardiac fibrosis and a more plastic ventricle at baseline, is associated with CRT responsiveness. Contrary to previous reports, the NGF levels were not reduced during HF and that there was no NGF rebound in CRT responders.
Magnetic Resonance Imaging in Patients with Recently Implanted Pacemakers
Friedman, Hannah, Acker, Nancy, Dalzell, Connie, Shen, Win K., Asirvatham, Samuel J. , Cha, Yong‐Mei , Hodge, David O. , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Friedman, Hannah L, Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1090-1095

10.1111/pace.12213 | PMID 23826621 Get It

BackgroundRecent studies have shown that magnetic resonance imaging (MRI) of patients with pacemakers can be safely performed under careful monitoring, but they excluded patients with recently implanted devices. Patients with recent implants may be at a greater risk for complications during MRI imaging due to lack of lead and wound maturity.MethodsWe implemented a clinical protocol for MRI imaging of patients with implanted cardiac devices, and prospectively collected data. For this study, we retrospectively analyzed two groups of patients: those with recently implanted (≤42 days) and nonrecently implanted (>42 days) leads at the time of MRI scanning. All devices were interrogated before and after scanning, and were reprogrammed during the scan as per protocol.ResultsOf the 219 scans (in 171 patients), eight included patients with recently implanted (range: 7–36 days) and 211 with only nonrecently implanted pacemaker leads. During the scan, there were no complications in the early or late group. In one patient imaged 79 days postimplant, frequent premature ventricular complexes were noted during the scan, requiring no action. No patient reported pain during or immediately after the procedure. No clinically significant changes in function were seen at subsequent follow up (average 104 days post‐MRI). Compared to patients with nonrecently implanted leads, there was no difference in any parameter between the two groups.ConclusionsWith a strong clinical indication and with careful monitoring, MRI imaging is feasible in patients with recently implanted pacemakers, although experience is limited.
Cardiac Device Complications in the Cognitively Impaired
Jama, Abdi, Hodge, David O. , Herges, Regina M., Asirvatham, Samuel, Cha, Yong‐Mei , Powell, Brian D. , Rea, Robert F., Friedman, Paul A. , Asirvatham, Samuel J. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1061-1067

10.1111/pace.12205 | PMID 23822919 Get It

BackgroundPatients with preexisting mild cognitive impairment or dementia may be at increased risk for developing cardiac device complications due to an impaired ability to follow postimplant care instructions. We sought to determine whether rates of infection, lead dislodgement, or appropriate or inappropriate implantable cardioverter defibrillator (ICD) shocks are increased in this population.MethodsMedical charts of 561 patients with mild cognitive impairment or dementia who underwent pacemaker (PM) or ICD implantation between January 2002 and October 2009 at Mayo Clinic were identified. A total of 134 patients who were diagnosed with cognitive impairment or dementia before device implantation or within 1 year of implantation were compared with 134 matched controls. Information was collected on patient characteristics, comorbid medical conditions, ejection fraction, complications, device type, device therapy, and mortality. Device information was prospectively entered into a database and retrospectively reviewed.ResultsOf the 134 patients with mild cognitive impairment and dementia, 99 underwent PM implantation and 35 underwent ICD implantation. Compared to controls, there was no difference in patient characteristics, ejection fraction, or comorbidities except for diabetes, which was more prevalent in the cognitively impaired and demented group (18.7% vs 30.6%, P = 0.02). There was no difference in device therapy and complications (14.4% vs 5.8%, P = 0.268). However, there was a decreased survival in patients with cognitive impairment and dementia when compared to the control group (42% vs 67% at 5 years, P = 0.007).ConclusionPatients with cognitive impairment and standard device indications are not at increased risk for device complications and therapy but their survival is much lower than in matched controls. The cause of this lower survival is unknown but may be related to the underlying neurological disease. Presence of cognitive impairment should therefore be considered when contemplating implantation of a cardiac device.
Outcomes of Cardiac Resynchronization Therapy in the Elderly
Killu, Ammar M. , WU, JIA‐HUI, Friedman, Paul A. , Shen, Win-Kuang, Webster, Tracy L., Brooke, Kelly L., Hodge, David O. , Wiste, Heather J. , Cha, Yong‐Mei

Mayo Clinic

Pacing and Clinical Electrophysiology | December 18, 2012 | Volume: 36 | Issue: 6 | Pages: 664-672

10.1111/pace.12048 | PMID 23252710 Get It

BackgroundOctogenarians (>80 years) have been underrepresented in clinical trials of cardiac resynchronization therapy (CRT).ObjectiveTo determine the benefit of CRT with or without a defibrillator in older elderly patients.MethodsWe retrospectively studied consecutive patients who received CRT at our institution from 2002 through 2008. New York Heart Association (NYHA) class and echocardiographic parameters were assessed before and after CRT. Thirty‐day complications after device implant were collected. Survival data were obtained from the national death and location database. Data were compared between those 80 years and younger and those older than 80 years.ResultsOf 728 patients identified, 90 (12.4%) were older than 80 years. After CRT, older and younger patients had similar improvements in NHYA class (P = 0.41), ejection fraction (P = 0.48), and mitral valve regurgitation (MR) severity (P = 0.42). In the older patients, defibrillator implantation was associated with comparable improvement in NYHA class, ejection fraction, and MR grade severity (P > 0.05), as in those without a defibrillator. Overall survival was worse in octogenarians than in the younger patients by Kaplan‐Meier estimates (P = 0.001). Multivariate analysis showed similar survival between the younger and older subjects (hazard ratio, 1.23; 95% confidence interval, 0.83–1.84; P = 0.31). The observed complication rate in all study subjects was 12.2%, with no difference between the two age groups.ConclusionOctogenarian patients who received CRT with or without a defibrillator for advanced heart failure had similar clinical benefits as younger patients. CRT should not be withheld from octogenarians meeting current selection guidelines.
Left Ventricular Discoordination Index Measured by Speckle Tracking Strain Rate Imaging Predicts Reverse Remodelling and Survival After Cardiac Resynchronization Therapy
Wang, Chun‐Li, Powell, Brian D. , Redfield, Margaret M. , Miyazaki, Chinami , Olson, Lyle J. , Cha, Yong‐Mei , Espinosa, Raúl E. , Hayes, David L. , Hodge, David O. , Lin, Grace , Friedman, Paul A. , Oh, Jae K. , Fine, Nowell Mark

Mayo Clinic

European Journal of Heart Failure | March 12, 2012 | Volume: 14 | Issue: 5 | Pages: 517-525

10.1093/eurjhf/hfs025 | PMID 22411692 Get It

Abstract Aims This study aimed to evaluate the predictive value of a baseline speckle tracking strain rate imaging-derived discoordination index for response to cardiac resynchronization therapy (CRT). Methods and results Ninety-seven patients with QRS ≥120 ms and left ventricular (LV) ejection fraction ≤35% were prospectively followed after CRT in the Mayo CRT Registry. The LV discoordination index (stretch/shortening or thinning/thickening during ejection) was calculated from three types of deformation, radial, circumferential, and longitudinal, using two-dimensional speckle tracking strain rate imaging. The benefit of CRT was evaluated by reverse remodelling (i.e. reduction of LV end-systolic volume ≥15% at 6-month follow-up) and survival. The optimal cut-off value of the baseline discoordination index in discriminating responders from non-responders was determined by receiver operating characteristic curve analysis. Significant differences in baseline indices between responders and non-responders were noted for radial and circumferential discoordination indices. A mid-ventricular radial discoordination index (RDI-M) &gt;38% best predicted responders, especially in patients with ischaemic cardiomyopathy (area under the curve 0.86 for all patients, sensitivity 80%, and specificity 91%). Death occurred in 28 patients over a median follow-up of 3.2 years. When adjusted for confounding variables, lack of significant discoordination (RDI-M &lt;38%) before CRT was associated with a particularly high mortality (hazard ratio 7.05, 95% confidence interval 2.45–26.0). Conclusion LV discoordination assessed by speckle tracking RDI-M imaging was able to predict reverse remodelling at 6 months and survival of patients who received CRT.