Citations

Clear

192 citation(s) found for "Johnson, Bruce".

The Effect of Diuresis on Extravascular Lung Water and Pulmonary Function in Acute Decompensated Heart Failure
Chase, Steven C. , Fermoyle, Caitlin C. , Wheatley, Courtney M. , Schaefer, Jacob J. , Olson, Lyle J. , Johnson, Bruce D.

Mayo Clinic

ESC Heart Failure | January 18, 2018 | Volume: 5 | Issue: 2 | Pages: 364-371

10.1002/ehf2.12253 | PMID 29345431 Get It

Abstract Aims The effect of extravascular lung water (EVLW) and relationship to functional status as a result of acute decompensated heart failure (ADHF) are not well understood. We sought to quantify changes in clinical variables, EVLW, airway anatomy, spirometry, and diffusing capacity for carbon monoxide before and after treatment for ADHF. Methods and results Fifteen patients were recruited within 24 h of hospital admission. Spirometry, diffusing capacity for carbon monoxide, and surrogates of EVLW by computed tomography were measured and were then repeated within 24 h of discharge. From the computed tomography (CT) scan, surrogates of EVLW were calculated from the distribution of CT attenuation of the lung tissue. Airways were segmented using the Vida Apollo software. Patients were hospitalized for 4.6 ± 2.1 days, had 10 ± 4.8 L of fluid removed (7.0 ± 4.2 L between study visits), and lost 7.1 ± 4.9 kg. Patients had significant clearance of fluid from the lungs (per cent change: mean, 4.2 ± 6.1%; skew, 17.5 ± 27.0%; kurtosis, 37.6 ± 56.7%; full-width half-maximum, 10.2 ± 13.5%). Static lung volumes and maximal flows improved significantly (per cent change: forced vital capacity, 14.5 ± 13.6%; forced expiratory volume in 1 s, 15.9 ± 14.0%; forced expiratory flow at 25–75% of forced vital capacity, 27.2 ± 42.9%). The ratio of membrane conductance to capillary blood volume improved significantly (per cent change: alveolar–capillary membrane conductance/capillary blood volume, 23.4 ± 22.8%). Weight loss during hospitalization was significantly correlated with improved spirometry and diffusing capacity. Conclusions Extravascular lung water contributes to the pulmonary congestive syndrome in ADHF patients, and its clearance is an important component of the improvement in pulmonary function as a result of inpatient treatment.
Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick
Johnson, Bruce D., Beck, Kenneth C., Dietz, Niki M., Proctor, David N. , Miller, Jordan D. , Joyner, Michael J.

Mayo Clinic

Journal of Applied Physiology | December 23, 2017 | Volume: 88 | Issue: 5 | Pages: 1650-1658

10.1152/jappl.2000.88.5.1650 | PMID 10797126 Get It

An open-circuit (OpCirc) acetylene uptake cardiac output (Q˙t) method was modified for use during exercise. Two computational techniques were used. OpCirc1 was based on the integrated uptake vs. end-tidal change in acetylene, and OpCirc2 was based on an iterative finite difference modeling method. Six subjects [28–44 yr, peak oxygen consumption (V˙o2) = 120% predicted] performed cycle ergometry exercise to compareQ˙t using OpCirc and direct Fick methods. An incremental protocol was repeated twice, separated by a 10-min rest, and subsequently subjects exercised at 85–90% of their peak work rate. Coefficient of variation of the OpCirc methods and Fick were highest at rest (OpCirc1, 7%, OpCirc2, 12%, Fick, 10%) but were lower at moderate to high exercise intensities (OpCirc1, 3%, OpCirc2, 3%, Fick, 5%). OpCirc1 and OpCirc2 Q˙t correlated highly with Fick Q˙t( R2= 0.90 and 0.89, respectively). There were minimal differences between OpCirc1 and OpCirc2 compared with Fick up to moderate-intensity exercise (<70% peakV˙o2); however, both techniques tended to underestimate Fick at >70% peakV˙o2. These differences became significant for OpCirc1 only. Part of the differences between Fick and OpCirc methods at the higher exercise intensities are likely related to inhomogeneities in ventilation and perfusion matching ( R2= 0.36 for Fick − OpCirc1 vs. alveolar-to-arterial oxygen tension difference). In conclusion, both OpCirc methods provided reproducible, reliable measurements ofQ˙t during mild to moderate exercise. However, only OpCirc2 appeared to approximate FickQ˙t at the higher work intensities.
Hypothyroidism alters diaphragm muscle development
Wilson, Louise, Johnson, Bruce D. , Zhan, Wen-Zhi, Sieck, Gary C. , Zhan, Wen‐Zhi

Mayo Clinic

Journal of Applied Physiology | December 22, 2017 | Volume: 81 | Issue: 5 | Pages: 1965-1972

10.1152/jappl.1996.81.5.1965 | PMID 8941517 Get It

Sieck, Gary C., Louise E. Wilson, Bruce D. Johnson, and Wen-Zhi Zhan. Hypothyroidism alters diaphragm muscle development. J. Appl. Physiol. 81(5): 1965–1972, 1996.—The impact of hypothyroidism (Hyp) on myosin heavy chain (MHC) isoform expression, maximum specific force (Po), fatigability, and maximum unloaded shortening velocity ( Vo) was determined in the rat diaphragm muscle (Dia) at 0, 7, 14, 21, and 28 days of age. Hyp was induced by treating pregnant rats with 6- n-propyl-2-thiouracil (0.05% in drinking water) beginning at gestational day 10 and was confirmed by reduced plasma levels of 3,5,3′-triiodothyronine and thyroxine. MHC isoforms were separated on sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels and analyzed by densitometry. Isometric Poand fatigue resistance of the Dia were measured in vitro at 26°C, and Vowas determined at 15°C with the slack test. Compared with control muscles, expression of MHC-slow was higher and expression of adult fast MHC isoforms was lower in Hyp Dia at all ages. The neonatal isoform of MHC continued to be expressed in the Hyp Dia until day 28. At each age, Poand fatigability were reduced and Vowas slower in the Hyp Dia. We conclude that Hyp-induced alterations in MHC isoform expression do not fully predict the changes in Dia contractile properties.
Differential susceptibility of diaphragm muscle fibers to neuromuscular transmission failure
Johnson, Bruce D., Sieck, Gary C.

Mayo Clinic

Journal of Applied Physiology | December 21, 2017 | Volume: 75 | Issue: 1 | Pages: 341-348

10.1152/jappl.1993.75.1.341 | PMID 8397179 Get It

The pattern of glycogen utilization was used to determine whether various muscle fiber types in the rat diaphragm are differentially susceptible to neuromuscular transmission failure. Muscle segments from the midcostal region were repetitively stimulated directly or via the phrenic nerve at 10 or 75 Hz. Muscle fiber types were classified histochemically as type I, IIa, or IIb. The amount of muscle fiber glycogen depletion with direct stimulation depended on stimulation rate (75 Hz > 10 Hz) and fiber type (IIb > IIa > I). However, with nerve stimulation, muscle fiber glycogen depletion did not display the same dependency on stimulation rate (10 Hz > 75 Hz), although with stimulation at 10 Hz, the same rank order of fiber depletion was observed (IIb > IIa > I). This rank order of depletion was reversed (I > IIa > IIb) during repetitive stimulation of the nerve at 75 Hz. By intermittently stimulating the muscle directly during continuous nerve stimulation, we determined that neuromuscular transmission failure contributed significantly to the force decline after 2 min of stimulation at 75 Hz but relatively little to the force decline after 2 min of stimulation at 10 Hz. A significantly greater fraction of the force decline could be attributed to neuromuscular transmission failure with repetitive bouts of stimulation at 10 Hz. We conclude that neuromuscular transmission failure causes a significant portion of the force decline after 8 min of stimulation at 10 and 75 Hz, that all diaphragm fiber types are susceptible to neuromuscular transmission failure, but that type IIb fibers are particularly susceptible at higher frequencies of stimulation.
Objective Versus Self-Reported Sleep Quality at High Altitude
Anderson, Paul J., Wood‐Wentz, Christina M. , Bailey, Kent R., Johnson, Bruce D.

Mayo Clinic

High Altitude Medicine & Biology | November 27, 2017 | Volume: 24 | Issue: 2 | Pages: 144-148

10.1089/ham.2017.0078 | PMID 29172727 Get It

Anderson, Paul J., Christina M. Wood-Wentz, Kent R. Bailey, and Bruce D. Johnson. Objective versus self-reported sleep quality at high altitude. High Alt Med Biol . 24:144–148, 2023. Background: Previous studies have found little relationship between polysomnography and a diagnosis of acute mountain sickness (AMS) using the Lake Louise Symptom Questionnaire (LLSQ). The correlation between sleep question responses on the LLSQ and polysomnography results has not been explored. We compared LLSQ sleep responses and polysomnography data from our previous study of workers rapidly transported to the South Pole. Methods: Sixty-three subjects completed a 3-hour flight from sea level to the South Pole (3200 m, 9800 ft). Participants completed limited overnight polysomnography on their first night and completed LLSQ upon awakening. We compared polysomnography results at the South Pole with sleep question responses on the LLSQ to assess their degree of correspondence. Results: Twenty-two (30%) individuals reported no sleep problems whereas 20 (32%) reported some problems and 20 (33%) individuals reported poor sleep and 1 reported no sleep ( n = 1). Median sleep efficiency was (94%) among response groups and mean overnight oxygen saturation was 81%. Median apnea hypopnea index (AHI; events/hour) was 10.2 in those who reported no problems sleeping, 5.1 in those reporting some problems sleeping, and 13.7 in those who reported poor sleep. These differences were not statistically significant. Conclusion: Self-reported sleep quality varied but there were no associated significant differences in sleep efficiency, overnight oxygen saturation, nor AHI. Studies that explore the role of objective sleep quality in the development of AMS should remove the sleep question on the LLSQ from AMS scoring algorithms.
The Design and Development of Active Compression Garments for Orthostatic Intolerance
Duvall, Julia, Granberry, Rachael , Dunne, Lucy E. , Holschuh, Brad , Kelly, Kevin L. , Johnson, Bruce , Johnson, Christopher D. , Joyner, Michael J.

Mayo Clinic

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3480 Get It

Current compression garments are often made from a spandex-type elastic material with static levels of compression and can become uncomfortable and difficult to don/doff [1]. This limits their usability, especially for unhealthy or aging populations. The only current alternative to elastic compression stockings are inflatable compression sleeves that are controllable, but highly immobile and must be tethered to an inflation source [2]. Neither design offers a solution that is simultaneously low profile, mobile, and controllable. Here we present the design and development of compression garments with embedded shape-changing materials that can produce controllable compression without the need for a bulky inflation system. This active materials approach enables dynamic control over the degree, timing and location of compression, and allows for graded, synchronized, pulsed, and peristaltic compression patterns, which provide the medical benefit of moving fluid in the body [2]. Such a design combines the best features of both elastic and inflatable compression garments: a slim, low-profile form factor that is easy to don/doff and provides dynamic control. Shape memory alloy (SMA) coil actuators, as described by Holschuh et al., [3] have the ability to apply compressive forces to the body when paired with passive textiles and wrapped circumferentially around the body. These actuators are engineered to contract when heated, creating controllable forces and displacements that are modulated through an applied current. SMA compression garments (SMA-CG) have important applications, from consumer uses to clinical interventions, including: augmenting venous return for conditions of orthostatic intolerance (e.g., postural orthostatic tachycardia syndrome (POTS)); cardiac rehabilitation in heart failure patients; lymphedema venous insufficiency; reducing deep vein thrombosis (DVT) risk; sports performance; and countermeasures for flight or space flight. While the potential uses for this technology are broad, the basic design is similar across many conditions. Key research areas include: 1) identifying and addressing design considerations relevant to prototype development of SMA-CG; 2) determining the compression thresholds needed to dynamically oppose orthostatic changes; and 3) evaluating the effectiveness of the prototypes for augmented venous return by synchronizing compression during cardiac diastole. Here, we focus on the first question: design of SMA-CG prototypes.
Alveolar air and oxidative metabolic demand during exercise in healthy adults: the role of single-nucleotide polymorphisms of the β 2 AR gene
Iterson, Erik H. Van , Snyder, Eric M., Johnson, Bruce D., Van Iterson, Erik H

Mayo Clinic

Physiological Reports | October 23, 2017 | Volume: 5 | Issue: 20 | Pages: e13476

10.14814/phy2.13476 | PMID 29061864 Get It

Physiological Dead Space and Arterial Carbon Dioxide Contributions to Exercise Ventilatory Inefficiency in Patients with Reduced or Preserved Ejection Fraction Heart Failure
Iterson, Erik H. Van , Johnson, Bruce D. , Borlaug, Barry A. , Olson, Thomas P. , Van Iterson, Erik H , Borlaug, Barry A

Mayo Clinic

European Journal of Heart Failure | October 8, 2017 | Volume: 19 | Issue: 12 | Pages: 1675-1685

10.1002/ejhf.913 | PMID 28990307 Get It

Abstract Aims Patients with heart failure (HF) with reduced (HFrEF) or preserved (HFpEF) ejection fraction demonstrate an increased ventilatory equivalent for carbon dioxide (V̇E/V̇CO2) slope. The physiological correlates of the V̇E/V̇CO2 slope remain unclear in the two HF phenotypes. We hypothesized that changes in the physiological dead space to tidal volume ratio (VD/VT) and arterial CO2 tension (PaCO2) differentially contribute to the V̇E/V̇CO2 slope in HFrEF vs. HFpEF. Methods and results Adults with HFrEF (n = 32) and HFpEF (n = 27) [mean ± standard deviation (SD) left ventricular ejection fraction: 22 ± 7% and 61 ± 9%, respectively; mean ± SD body mass index: 28 ± 4 kg/m2 and 33 ± 6 kg/m2, respectively; P &lt; 0.01] performed cardiopulmonary exercise testing with breath-by-breath ventilation and gas exchange measurements. PaCO2 was measured via radial arterial catheterization. We calculated the V̇E/V̇CO2 slope via linear regression, and VD/VT = 1 − [(863 × V̇CO2)/(V̇E × PaCO2)]. Resting VD/VT (0.48 ± 0.08 vs. 0.41 ± 0.11; P = 0.04), but not PaCO2 (38 ± 5 mmHg vs. 40 ± 3 mmHg; P = 0.21) differed between HFrEF and HFpEF. Peak exercise VD/VT (0.39 ± 0.08 vs. 0.32 ± 0.12; P = 0.02) and PaCO2 (33 ± 6 mmHg vs. 38 ± 4 mmHg; P &lt; 0.01) differed between HFrEF and HFpEF. The V̇E/V̇CO2 slope was higher in HFrEF compared with HFpEF (44 ± 11 vs. 35 ± 8; P &lt; 0.01). Variance associated with the V̇E/V̇CO2 slope in HFrEF and HFpEF was explained by peak exercise VD/VT (R2 = 0.30 and R2 = 0.50, respectively) and PaCO2 (R2 = 0.64 and R2 = 0.28, respectively), but the relative contributions of each differed (all P &lt; 0.01). Conclusions Relationships between the V̇E/V̇CO2 slope and both VD/VT and PaCO2 are robust, but differ between HFpEF and HFrEF. Increasing V̇E/V̇CO2 slope appears to be strongly explained by mechanisms influential in regulating PaCO2 in HFrEF, which contrasts with the strong role of increased VD/VT in HFpEF.
Gene Variant of the Bradykinin B2 Receptor Influences Pulmonary Arterial Pressures in Heart Failure Patients
Olson, Thomas P. , Bailey, Kent R. , Wood, Christina M., Johnson, Bruce D. , Frantz, Robert P. , Turner, Stephen T.

Mayo Clinic

Clinical medicine. Circulatory, respiratory and pulmonary medicine | September 13, 2017 | Volume: 3 | Issue: No issue available | Pages: CCRPM.S2147

10.4137/ccrpm.s2147 Get It

Background Pulmonary arterial pressure (PAP) varies considerably in heart failure (HF) despite similar degrees of left ventricular (LV) dysfunction. Bradykinin alters vascular tone and common variations in the kinin B2 receptor (BDKRB2) gene exists. We hypothesized that genetic variation in this receptor would influence PAP in HF. Methods 131 HF patients (>1yr history systolic HF), without COPD, not currently smoking, BMI < 40, without atrial fibrillation completed the study which included a blood draw for genotyping and neurohormones (ACE, A-II, Bradykinin, ANP, BNP, and catecholamines), an echocardiogram for cardiac function and systolic PAP (PAPsys). Results Mean LVEF was 29% ∓ 12%, NYHA class 2 ∓ 1, age 56 ∓ 12 yr, BMI 28 ∓ 5 kg/m 2 . Forty-six patients (35%) were homozygous for the +9 allele, 58 (44%) were heterozygous (+9/-9) and 27 (21%) were homozygous for the -9 allele of the BDKRB2. PAPsys averaged 42 ∓ 13, 38 ∓ 12, and 35 ∓ 11 mmHg for +9/+9, +9/-9 and -9/-9, respectively (p = 0.03). There was a trend towards gene effect for plasma ACE with the highest values in +9/+9 and lowest in -9/-9 patients (9.5 ∓ 10.7, 7.1 ∓ 8.7, and 5.4 ∓ 6.4 U/L, respectively, p = 0.06). There were no differences in plasma bradykinin or A-II, LVEF, or NYHA across genotypes. Conclusion These data suggest the +9/+9 polymorphism of the BDKRB2 receptor influences pulmonary vascular tone in stable HF.
The Usefulness of Submaximal Exercise Gas Exchange in Pulmonary Arterial Hypertension: A Case Series
Woods, Paul R., Johnson, Bruce D. , Frantz, Robert P.

Mayo Clinic

Clinical Medicine Insights: Circulatory, Respiratory and Pulmonary Medicine | September 13, 2017 | Volume: 4 | Issue: No issue available | Pages: 117954842020100

10.1177/117954842020100402 Get It

Introduction Submaximal exercise gas exchange may be a useful tool to track responses to therapy in pulmonary arterial hypertension (PAH) patients. Methods Three patients diagnosed with idiopathic PAH, on differing therapies, were included. Standard clinical tests (echocardiography; 6 minute walk) were performed pre and 3-5 months after treatment. Gas exchange was measured during 3 minutes of step exercise at both time points. Results Gas exchange variables, end tidal CO 2 (P ET CO 2 ) and the ratio of ventilation to CO 2 production (V E /VCO 2 ), during submaximal exercise were able to track patient responses to therapy over a 3-5 month period. Two patients demonstrated positive improvements, with an increased P ET CO 2 and decreased V E /VCO 2 during light exercise, in response to an altered therapeutic regime. The third patient had a worsening of gas exchange (decreased P ET CO 2 and increased V E /VCO 2 ) following no changes in the medical regime from the baseline visit. Conclusion Gas exchange variables measured during light submaximal exercise, such as P ET CO 2 and V E /VCO 2 , may be able to better detect small changes in functional status following treatment and could, therefore, be a useful tool to track disease severity in PAH patients. Further study is required to determine the clinical usefulness of these gas exchange variables.