Citations

Clear

151 citation(s) found for "Beltran, H".

Clinical efficacy and safety of a highly conformal, supine, hybrid forward and inverse planned intensity modulated radiation therapy technique for craniospinal irradiation
Kruse, Jon J. , Bradley, Thomas B., Beltran, Chris , Laack, Nadia N. , Ahmed, Safia K. , Beltran, Chris J., Laack, Nadia N Issa , Beltran, Chris J

Mayo Clinic

Acta Oncologica | November 13, 2017 | Volume: 57 | Issue: 5 | Pages: 629-636

10.1080/0284186x.2017.1400686 | PMID 29129125 Get It

MICRODOSIMETRIC APPLICATIONS IN PROTON AND HEAVY ION THERAPY USING SILICON MICRODOSIMETERS
Chartier, Lachlan, Tran, Linh T. , Bolst, David , Guatelli, Susanna , Pogossov, A, Prokopovich, Dale A., Reinhard, Mark I., Perevertaylo, Vladimir L. , Anderson, Sarah , Beltran, Chris , Matsufuji, Naruhiro, Jackson, Michael , Rosenfeld, Anatoly , Guatelli, S , Rosenfeld, A B , Beltran, Chris J , Anderson, S

Mayo Clinic

Radiation Protection Dosimetry | October 10, 2017 | Volume: 180 | Issue: 1-4 | Pages: 365-371

10.1093/rpd/ncx226 | PMID 29069515 Get It

Microdosimetric measurements of a clinical proton beam with micrometer‐sized solid‐state detector
Anderson, Sarah , Tran, Linh T. , Chartier, Lachlan, Petasecca, Marco , Lerch, Michael , Prokopovich, Dale A., Reinhard, Mark I., Perevertaylo, Vladimir L. , Rosenfeld, Anatoly , Herman, Michael , Beltran, Chris , Anderson, Sarah E, Furutani, Keith M. , Herman, Michael G., Rosenfeld, A B , Beltran, Chris J , Anderson, Sarah E.

Mayo Clinic

Medical Physics | September 14, 2017 | Volume: 44 | Issue: 11 | Pages: 6029-6037

10.1002/mp.12583 | PMID 28905399 Get It

PurposeMicrodosimetry is a vital tool for assessing the microscopic patterns of energy deposition by radiation, which ultimately govern biological effect. Solid‐state, silicon‐on‐insulator microdosimeters offer an approach for making microdosimetric measurements with high spatial resolution (on the order of tens of micrometers). These high‐resolution, solid‐state microdosimeters may therefore play a useful role in characterizing proton radiotherapy fields, particularly for making highly resolved measurements within the Bragg peak region. In this work, we obtain microdosimetric measurements with a solid‐state microdosimeter (MicroPlus probe) in a clinical, spot‐scanning proton beam of small spot size.MethodsThe MicroPlus probe had a 3D single sensitive volume on top of silicon oxide. The sensitive volume had an active cross‐sectional area of 250 μm × 10 μm and thickness of 10 μm. The proton facility was a synchrotron‐based, spot‐scanning system with small spot size (σ ≈ 2 mm). We performed measurements with the clinical beam current (≈1 nA) and had no detected pulse pile‐up. Measurements were made in a water‐equivalent phantom in water‐equivalent depth (WED) increments of 0.25 mm or 1.0 mm along pristine Bragg peaks of energies 71.3 MeV and 159.9 MeV, respectively. For each depth, we measured lineal energy distributions and then calculated the dose‐weighted mean lineal energy, . The measurements were repeated for two field sizes: 4 × 4 cm2 and 20 × 20 cm2.ResultsFor both 71.3 MeV and 159.9 MeV and for both field sizes, increased with depth toward the distal edge of the Bragg peak, a result consistent with Monte Carlo calculations and measurements performed elsewhere. For the 71.3 MeV, 4 × 4 cm2 beam (range at 80% distal falloff, R80 = 3.99 cm), we measured keV/μm at WED = 2 cm, and keV/μm at WED = 3.95 cm. For the 71.3 MeV, 20 × 20 cm2 beam, we measured keV/μm at WED = 2.6 cm, and keV/μm at WED = 3 cm. For the 159.9 MeV, 4 × 4 cm2 beam (R80 = 17.7 cm), keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm. For the 159.9 MeV, 20 × 20 cm2 beam, keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm.ConclusionsWe performed microdosimetric measurements with a novel solid‐state, silicon‐on‐insulator microdosimeter in a clinical spot‐scanning proton beam of small spot size and unmodified beam current. For all of the proton field sizes and energies considered, the measurements of were in agreement with expected trends. Furthermore, we obtained measurements with a spatial resolution of 10 μm in the beam direction. This spatial resolution greatly exceeded that possible with a conventional gaseous tissue‐equivalent proportional counter and allowed us to perform a high‐resolution investigation within the Bragg peak region. The MicroPlus probe is therefore suitable for applications in proton radiotherapy.
Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid‐state microdosimeter
Tran, Linh T. , Chartier, Lachlan, Bolst, David , Pogossov, Alex , Guatelli, Susanna , Petasecca, Marco , Lerch, Michael , Prokopovich, Dale A., Reinhard, Mark I., Clasie, B. , Depauw, Nicolas , Kooy, Hanne M., Flanz, J., McNamara, Aimee L. , Beltran, Chris , Perevertaylo, Vladimir L. , Jackson, Michael , Rosenfeld, Anatoly , Furutani, Keith, Guatelli, S , Rosenfeld, A B , Beltran, Chris J , Paganetti, Harald , Furutani, Keith M.

Mayo Clinic

Medical Physics | September 9, 2017 | Volume: 44 | Issue: 11 | Pages: 6085-6095

10.1002/mp.12563 | PMID 28887837 Get It

PurposeThis work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well‐defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam.MethodsA novel silicon microdosimeter with well‐defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15 keV/μm. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread‐out Bragg peak (SOBP) in 0.5 mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth‐dose distribution from the treatment planning system (TPS) and to compare the simulated dose‐mean lineal energy to the experimental results.ResultsFor a 131 MeV PBS spot (124.6 mm R90 range in water), the measured dose‐mean lineal energy increased from 2 keV/μm at the entrance to 8 keV/μm in the BP, with a maximum value of 10 keV/μm at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.97 ± 0.14 at the entrance to 1.04 ± 0.09 proximal to the BP, then to 1.1 ± 0.08 in the BP, and steeply rose to 1.57 ± 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 ± 0.16 to 1.01 ± 0.16 at shallow depths, and 1.01 ± 0.16 to 1.28 ± 0.17 within the SOBP. The RBE significantly increased from 1.29 ± 0.17 to 1.43 ± 0.18 at the distal edge of the SOBP.ConclusionsThe SOI microdosimeter with its well‐defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82 Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy.
Abstract 3093: Expression of DLL3 in metastatic melanoma, glioblastoma and high-grade extrapulmonary neuroendocrine carcinomas as potential indications for rovalpituzumab tesirine (Rova-T; SC16LD6.5), a delta-like protein 3 (DLL3)-targeted antibody drug co
Saunders, Laura R. , Bheddah, Sheila, Isse, Kumiko, Fong, Sarah , Pysz, Marybeth A. , Beltran, Himisha , Sailer, Verena , Yin, Yu Zhi, Koshkin, Vadim S. , Grivas, Petros , Kosari, Farhad , Cheville, John C. , Moser, Justin C. , Flotte, Thomas J. , Hálfdánarson, Þorvarður R. , Leventakos, Konstantinos , Molina, Julian R. , Ball, Douglas W., Nelkin, Barry D. , Scaife, Courtney L. , Dylla, Scott J., Williams, Samuel A. , Puca, Loredana , Mosquera, Juan Miguel , Huang, Jiaoti , Armstrong, Andrew J. , García, Jorge , Magi‐Galluzzi, Cristina , Mansfield, Aaron S. , Shea, Jill , Halfdanarson, Thorvardur R

Mayo Clinic

Cancer Research | July 31, 2017 | Volume: 77 | Issue: 13_Supplement | Pages: 3093-3093

10.1158/1538-7445.am2017-3093 Get It

Abstract Expression of DLL3 was examined in additional tumor types, as it was found to be highly expressed in tumor-initiating cells (TIC) in small cell lung cancer (SCLC), where a DLL3-targeted antibody drug conjugate (ADC), rovalpituzumab tesirine (Rova-T; SC16LD6.5; Saunders et al. 2015 Sci Transl Med 7:302ra136)) exerted clinically meaningful anti-tumor effects in a phase I trial (Spigel et al. 2016 Lancet Oncology; In Press). DLL3 expression was profiled by qRT-PCR, ELISA and immunohistochemistry in multiple tumor types. Patient-derived xenografts (PDX) from melanoma and ovarian small cell carcinoma were established and used for efficacy studies to determine the ability of Rova-T to impact tumor growth and TIC frequency. DLL3 expression was seen in metastatic melanoma (55%), low grade gliomas (90%), glioblastoma (70%), medullary thyroid cancer (65%), carcinoids (33%), dispersed neuroendocrine tumors in the pancreas (9%), bladder (57%) and prostate (24%), testicular cancer (90%), and lung adenocarcinomas with neuroendocrine features (80%). Unlike SCLC, where DLL3 does not predict clinical outcome on standard therapies, DLL3 expression negatively correlates with overall survival in melanoma and small cell bladder cancer. In mice bearing DLL3 positive melanoma PDX, treatment with a single dose of Rova-T resulted in effective and durable responses (>100 days), which correlated with a significant impact on TIC frequency. Similarly, in mice bearing DLL3-positive ovarian small cell PDX, a single dose of Rova-T resulted in effective and durable responses (>100 days). Our results show that DLL3 is expressed in many neuroendocrine tumors (lung, ovarian, prostate, bladder, etc), metastatic melanoma, medullary thyroid cancer, low-grade gliomas and glioblastoma. Given pre-clinical results showing efficacy of Rova-T in melanoma and ovarian small cell carcinoma, as well as encouraging clinical data with Rova-T in patients with recurrent/refractory SCLC, clinical evaluation of Rova-T in DLL3-positive melanoma, glioblastoma, medullary thyroid cancer and other high-grade neuroendocrine carcinomas is warranted. A “basket” trial enrolling patients with DLL3-positive solid tumors is now recruiting patients (NCT02709889). Citation Format: Laura R. Saunders, Samuel A. Williams, Sheila Bheddah, Kumiko Isse, Sarah Fong, Marybeth A. Pysz, Himisha Beltran, Loredana Puca, Verena Sailer, Juan M. Mosquera, Yu Yin, Jiaoti Huang, Andrew J. Armstrong, Jorge Garcia, Cristina Magi-Galluzzi, Vadim Koshkin, Petros Grivas, Farhad Kosari, John Cheville, Justin C. Moser, Thomas J. Flotte, Thorvardur Halfdanarson, Aaron Mansfield, Konstantinos N. Leventakos, Julian R. Molina, Douglas W. Ball, Barry D. Nelkin, Jill E. Shea, Courtney L. Scaife, Scott J. Dylla. Expression of DLL3 in metastatic melanoma, glioblastoma and high-grade extrapulmonary neuroendocrine carcinomas as potential indications for rovalpituzumab tesirine (Rova-T; SC16LD6.5), a delta-like protein 3 (DLL3)-targeted antibody drug conjugate (ADC) [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 3093. doi:10.1158/1538-7445.AM2017-3093
Pathology Imagebase—a reference image database for standardization of pathology
Egevad, Lars , Cheville, John C. , Evans, Andrew , Hörnblad, Jonas, Kench, James G. , Leite, Kátia Ramos Moreira , Pan, Chin‐Chen , Samaratunga, Hemamali , Srigley, John R., True, Lawrence D. , Zhou, Ming , Clements, Mark , Delahunt, Brett , Panel, The ISUP Pathology Imagebase Expert, Cheng, Liang , López-Beltrán, Antonio , Távora, Fábio , Netto, George J. , Tsuzuki, Toyonori , Pan, Chin-Chen , Delahunt, Brett , Kristiansen, Glen , Magi‐Galluzzi, Cristina , Panel, The ISUP Pathology Imagebase Expert, Tsuzuki, Toyonori , Samaratunga, Hemamali , Cheng, Liang

Mayo Clinic

Histopathology | July 19, 2017 | Volume: 71 | Issue: 5 | Pages: 677-685

10.1111/his.13313 | PMID 28722802 Get It

AimsDespite efforts to standardize histopathology practice through the development of guidelines, the interpretation of morphology is still hampered by subjectivity. We here describe Pathology Imagebase, a novel mechanism for establishing an international standard for the interpretation of pathology specimens.Methods and resultsThe International Society of Urological Pathology (ISUP) established a reference image database through the input of experts in the field. Three panels were formed, one each for prostate, urinary bladder and renal pathology, consisting of 24 international experts. Each of the panel members uploaded microphotographs of cases into a non‐public database. The remaining 23 experts were asked to vote from a multiple‐choice menu. Prior to and while voting, panel members were unable to access the results of voting by the other experts. When a consensus level of at least two‐thirds or 16 votes was reached, cases were automatically transferred to the main database. Consensus was reached in a total of 287 cases across five projects on the grading of prostate, bladder and renal cancer and the classification of renal tumours and flat lesions of the bladder. The full database is available to all ISUP members at www.isupweb.org. Non‐members may access a selected number of cases.ConclusionsIt is anticipated that the database will assist pathologists in calibrating their grading, and will also promote consistency in the diagnosis of difficult cases.
Characterization of relative biological effectiveness for conventional radiation therapy: a comparison of clinical 6 MV X-rays and 137Cs
Howard, Michelle E. , Beltran, Chris , Herman, Michael , Sarkaria, Jann, Herman, Michael G., Sarkaria, Jann N. , Beltran, Chris J

Mayo Clinic

Journal of Radiation Research | April 5, 2017 | Volume: 58 | Issue: 5 | Pages: 608-613

10.1093/jrr/rrx018 | PMID 28444207 Get It

ABSTRACT Various types of radiation are utilized in the treatment of cancer. Equal physical doses of different radiation types do not always result in the same amount of biological damage. In order to account for these differences, a scaling factor known as the relative biological effectiveness (RBE) can be used. 137Cesium (137Cs) has been used as a source of radiation in a significant body of radiation therapy research. However, high-energy X-rays, such as 6 MV X-rays, are currently used clinically to treat patients. To date, there is a gap in the literature regarding the RBE comparison of these two types of radiation. Therefore, the purpose of this study was to investigate the RBE of 137Cs relative to that of 6 MV X-rays. To determine the RBE, five cell lines were irradiated [Chinese hamster ovary (CHO); human lung adenocarcinoma (A549); human glioma (U251); human glioma (T98); and human osteosarcoma (U2OS)] by both types of radiation and assessed for cell survival using a clonogenic assay. Three of the five cell lines resulted in RBE values of ~1.00 to within 11% for all survival fractions, showing the physical and biological dose for these two types of radiation were equivalent. The other two cell lines gave RBE values differing from 1.00 by up to 36%. In conclusion, the results show the range in biological effect seen between cell lines, and therefore cell type must be considered when characterizing RBE.
Novel Treatment of Melanoma: Combined Parasite-Derived Peptide GK-1 and Anti-Programmed Death Ligand 1 Therapy
Vera-Aguilera, Jesús, Beltrán, D. Dualde , Villanueva-Ramos, Cynthia, Wachtel, Mitchell S. , Moreno-Aguilera, Eduardo, Vera-Aguilera, Carlos, Ventolini, Gary , Martı́nez–Zaguilán, Raul, Sennoune, Souad R. , Pérez‐Torres, Armando

Mayo Clinic

Cancer Biotherapy and Radiopharmaceuticals | March 16, 2017 | Volume: 32 | Issue: 2 | Pages: 49-56

10.1089/cbr.2016.2123 | PMID 28301259 Get It

A simplified methodology to produce Monte Carlo dose distributions in proton therapy
Beltran, Chris , Jia, Yingcui, Slopsema, R , Yeung, Daniel , Li, Zuofeng , Beltran, Chris J

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 4 | Pages: 2-10

10.1120/jacmp.v15i4.4413 | PMID 25207391 Get It

The purpose of this study was to develop a simplified methodology that will produce Monte Carlo (MC) dose distribution for proton therapy which can be used as a clinical aid in determining the adequacy of proton plans produced from the treatment planning system (TPS). The Geant4 Monte Carlo toolkit was used for all simulations. The geometry of the double scatter nozzle in the simulation was a simplification of the treatment nozzle. The proton source was modeled as discrete energy layers, each with a unique energy distribution and weighting factor. The simplified MC system was designed to give the same dose distribution as the measured data used to commission the TPS. After the simplified MC system was finalized, a series of verification comparisons were made between it, measurements, and the clinically used TPS. Comparisons included the lateral profile of a stair‐shaped compensator that simulated a sharp lateral heterogeneity and depth‐dose measurements through heterogeneous materials. The simplified MC system matched measurements to within 2% or 2 mm for all commissioning data under investigation; moreover, the distal edge and lateral penumbra was within 1 mm of the measurements. The simplified MC system was able to better reproduce the measured profiles for a stair‐shaped compensator than the TPS. Both MC and TPS matched the measured depth dose through heterogeneous materials to within 2% or 2 mm. The simplified MC system was straightforward to implement, and produced accurate results when compared to measurements. Therefore, it holds promise as a clinically useful methodology to validate the relative dose distribution of patient treatment plans produced by the treatment planning systems.PACS number: 87.55.K‐, 87.55.ne
A cyclin-D1 interaction with BAX underlies its oncogenic role and potential as a therapeutic target in mantle cell lymphoma
Beltrán, Elena, Fresquet, Vicente , Martínez‐Useros, Javier , Richter-Larrea, Jose A., Sagardoy, Ainara, Sesma, Izaskun, Almada, Luciana L. , Montes‐Moreno, Santiago , Siebert, Reiner , Gesk, Stefan, Calasanz, Marı́a José , Malumbres, Raquel, Rieger, Melissa, Prósper, Felipe , Lossos, Izidore S. , Piris, Miguel Á. , Fernández-Zapico, Martín E. , Martinez‐Climent, José A. , Piris, Miguel , Martinez-Climent, Jose Angel , Prosper, Felipe , Montes-Moreno, Santiago

Mayo Clinic

Proceedings of the National Academy of Sciences | July 12, 2011 | Volume: 108 | Issue: 30 | Pages: 12461-12466

10.1073/pnas.1018941108 | PMID 21746927 Get It

The chromosomal translocation t (11;14)(q13;q32) leading to cyclin-D1 overexpression plays an essential role in the development of mantle cell lymphoma (MCL), an aggressive tumor that remains incurable with current treatment strategies. Cyclin-D1 has been postulated as an effective therapeutic target, but the evaluation of this target has been hampered by our incomplete understanding of its oncogenic functions and by the lack of valid MCL murine models. To address these issues, we generated a cyclin-D1–driven mouse model in which cyclin-D1 expression can be regulated externally. These mice developed cyclin-D1–expressing lymphomas capable of recapitulating features of human MCL. We found that cyclin-D1 inactivation was not sufficient to induce lymphoma regression in vivo; however, using a combination of in vitro and in vivo assays, we identified a novel prosurvival cyclin-D1 function in MCL cells. Specifically, we found that cyclin-D1, besides increasing cell proliferation through deregulation of the cell cycle at the G 1 –S transition, sequestrates the proapoptotic protein BAX in the cytoplasm, thereby favoring BCL2’s antiapoptotic function. Accordingly, cyclin-D1 inhibition sensitized the lymphoma cells to apoptosis through BAX release. Thus, genetic or pharmacologic targeting of cyclin-D1 combined with a proapoptotic BH3 mimetic synergistically killed the cyclin-D1–expressing murine lymphomas, human MCL cell lines, and primary lymphoma cells. Our study identifies a role of cyclin-D1 in deregulating apoptosis in MCL cells, and highlights the potential benefit of simultaneously targeting cyclin-D1 and survival pathways in patients with MCL. This effective combination therapy also might be exploited in other cyclin-D1–expressing tumors.