Citations

Clear

6056 citation(s) found for "Wu, Peter".

Comparison of da Vinci Single Port vs Si Systems for Transoral Robotic-Assisted Surgery
Oberhelman, Nicholas J., Bruening, Jennifer , Abel, Kathryn M. Van , Sumer, Baran D. , Andersen, Peter E. , Li, Ryan J. , Van Abel, Kathryn M , Jackson, Ryan S. , Holsinger, F. Christopher , Chan, Jason Y. K. , Gross, Neil D , Clayburgh, Daniel

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | December 21, 2023 | Volume: 150 | Issue: 2 | Pages: 165

10.1001/jamaoto.2023.3994 | PMID 38127360 Get It

Importance Transoral robot-assisted surgery (TORS) continues to have a major role in the treatment of oropharyngeal cancer. As new iterations of robotic technology are increasingly utilized, it is important to share learning experiences and clinical outcomes data, to optimize technical efficiency and clinical care. Observations This was a retrospective review of a large academic institution’s initial clinical use of the da Vinci Single Port (SP) compared with the da Vinci Si (Si) system. A total of 205 TORS cases were reviewed: 109 in the SP group (November 22, 2018, through September 30, 2020), and 96 in the Si group (January 1, 2016, through November 12, 2018). Both groups had comparable operative times, rates of postoperative pharyngeal hemorrhage, length of hospital stay, and duration of nasogastric feeding tube use. There was no difference in pathological characteristics, rates of positive margins, or indications for or time to initiation of adjuvant therapy between the groups. The collective experience of 6 faculty members—who have trained 139 TORS surgeons for the SP system rollout—was compiled to provide a summary of learning experiences and technical notes on safe and efficient operation of the SP system. Conclusions and Relevance This Review found that the functional and oncologic outcomes were comparable between TORS cases performed with the Si and SP systems, and they had similar complication rates. Recognized advantages of the SP over the Si system include the availability of bipolar-energized instruments, a usable third surgical arm, and improved camera image quality.
The Concise Guide to PHARMACOLOGY 2023/24: Catalytic receptors
Alexander, S P H , Fabbro, Doriano , Mathie, Alistair , Peters, John A. , Veale, Emma L. , Armstrong, Jane F , Faccenda, Elena , Harding, Simon D , Davies, Jamie A. , Beuve, Annie , Brouckaert, Peter, Burnett, John C. , Friebe, Andreas , Garthwaite, John , Koesling, Doris , Kühn, Michaela , Potter, Lincoln R. , Stasch, Johannes‐Peter, Alexander, Stephen P H , Mathie, Alistair A , Peters, John A , Veale, Emma L , Armstrong, Jane F , Faccenda, Elena , Harding, Simon D , Davies, Jamie A , Bryant, Clare , Farndale, Richard W , Jarvis, Gavin E , MacEwan, David , Monie, Tom P , Kelly, Eamonn , Hobbs, Adrian J , Russwurm, Michael , Schmidt, Harald , Waldman, Scott A.

Mayo Clinic

British Journal of Pharmacology | December 21, 2023 | Volume: 180 | Issue: S2 | Pages: No page available

10.1111/bph.16180 | PMID 38123155 Get It

The Concise Guide to PHARMACOLOGY 2023/24 is the sixth in this series of biennial publications. The Concise Guide provides concise overviews, mostly in tabular format, of the key properties of approximately 1800 drug targets, and nearly 6000 interactions with about 3900 ligands. There is an emphasis on selective pharmacology (where available), plus links to the open access knowledgebase source of drug targets and their ligands (https://www.guidetopharmacology.org/), which provides more detailed views of target and ligand properties. Although the Concise Guide constitutes almost 500 pages, the material presented is substantially reduced compared to information and links presented on the website. It provides a permanent, citable, point‐in‐time record that will survive database updates. The full contents of this section can be found at http://onlinelibrary.wiley.com/doi/10.1111/bph.16180. Catalytic receptors are one of the six major pharmacological targets into which the Guide is divided, with the others being: G protein‐coupled receptors, ion channels, nuclear hormone receptors, enzymes and transporters. These are presented with nomenclature guidance and summary information on the best available pharmacological tools, alongside key references and suggestions for further reading. The landscape format of the Concise Guide is designed to facilitate comparison of related targets from material contemporary to mid‐2023, and supersedes data presented in the 2021/22, 2019/20, 2017/18, 2015/16 and 2013/14 Concise Guides and previous Guides to Receptors and Channels. It is produced in close conjunction with the Nomenclature and Standards Committee of the International Union of Basic and Clinical Pharmacology (NC‐IUPHAR), therefore, providing official IUPHAR classification and nomenclature for human drug targets, where appropriate.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Mayo Clinic

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 | PMID 38115695 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
On the optimization of 3D inflow‐based vascular‐space‐occupancy (iVASO) MRI for the quantification of arterial cerebral blood volume (CBVa)
Gu, Chunming , Li, Yinghao , Cao, Di , Miao, Xinyuan , Paez, Adrian , Sun, Yuanqi, Cai, Jitong, Li, Wenbo , Pillai, Jay J. , Earley, Christopher J. , Sun, Yuanqi , Pillai, Jay J , Gu, Chunming , Li, Xu , Zijl, Peter C.M. van

Mayo Clinic

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1893-1907

10.1002/mrm.29971 | PMID 38115573 Get It

AbstractPurposeThe inflow‐based vascular‐space‐occupancy (iVASO) MRI was originally developed in a single‐slice mode to measure arterial cerebral blood volume (CBVa). When vascular crushers are applied in iVASO, the signals can be sensitized predominantly to small pial arteries and arterioles. The purpose of this study is to perform a systematic optimization and evaluation of a 3D iVASO sequence on both 3 T and 7 T for the quantification of CBVa values in the human brain.MethodsThree sets of experiments were performed in three separate cohorts. (1) 3D iVASO MRI protocols were compared to single‐slice iVASO, and the reproducibility of whole‐brain 3D iVASO MRI was evaluated. (2) The effects from different vascular crushers in iVASO were assessed. (3) 3D iVASO MRI results were evaluated in arterial and venous blood vessels identified using ultrasmall‐superparamagnetic‐iron‐oxides–enhanced MRI to validate its arterial origin.Results3D iVASO scans showed signal‐to‐noise ratio (SNR) and CBVa measures consistent with single‐slice iVASO with reasonable intrasubject reproducibility. Among the iVASO scans performed with different vascular crushers, the whole‐brain 3D iVASO scan with a motion‐sensitized‐driven‐equilibrium preparation with two binomial refocusing pulses and an effective TE of 50 ms showed the best suppression of macrovascular signals, with a relatively low specific absorption rate. When no vascular crusher was applied, the CBVa maps from 3D iVASO scans showed large CBVa values in arterial vessels but well‐suppressed signals in venous vessels.ConclusionA whole‐brain 3D iVASO MRI scan was optimized for CBVa measurement in the human brain. When only microvascular signals are desired, a motion‐sensitized‐driven‐equilibrium–based vascular crusher with binomial refocusing pulses can be applied in 3D iVASO.
Screening Performance of S100 Calcium-Binding Protein B, Glial Fibrillary Acidic Protein, and Ubiquitin C-Terminal Hydrolase L1 for Intracranial Injury Within Six Hours of Injury and Beyond
Trivedi, Dhanisha , Forssten, Maximilian Peter , Czeiter, Endre , Amrein, Krisztina , Büki, András , DeSoucy, Erik, Cao, Yang , Ismail, Ahmad Mohammad , Kobeissy, Firas , Wang, Kevin , DeSoucy, Erik S. , Mohseni, Shahin

Mayo Clinic

Journal of Neurotrauma | December 20, 2023 | Volume: 41 | Issue: 3-4 | Pages: 349-358

10.1089/neu.2023.0322 | PMID 38115670 Get It

Abstract 19083: AI-Enabled ECG Detection of Atrial and Ventricular Septal Defects in Pediatric Patients
Greason, Grace , O’Sullivan, Donnchadh , Anjewierden, Scott , Lopez‐Jimenez, Francisco, Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.19083 Get It

Background: Atrial septal defects (ASD) and ventricular septal defects (VSD) are among the most common forms of congenital heart disease (CHD). Early detection and intervention for these defects are crucial to prevent complications. Given advancements in AI technology, the development of AI-enabled ECG models for detecting these defects is of significant interest. Aims: This study aimed to create AI models using pediatric ECG data for the detection of ASD, VSD, and a combined model detecting either ASD or VSD. Methods: We analyzed a dataset of 7,795 pediatric patients from Mayo Clinic who had undergone echocardiography between 2002 and 2022, with corresponding 10-second, 12-lead surface ECGs taken within 14 days of echocardiography. This dataset included 259 patients with ASDs and 139 patients with VSDs (single or multiple). The control group was comprised of 7,397 patients without significant or complex CHD. For cases and controls, we included patients with all forms of electrocardiographic abnormalities and those with valvular lesions who had less than moderate stenosis or regurgitation. The dataset was divided into training, validation, and testing subsets to develop convolutional neural network (CNN) models for ASD, VSD, and either ASD or VSD detection. Results: Our ASD and VSD detection models achieved test AUCs of 0.82 (95% CI 0.76, 0.88) and 0.80 (95% CI 0.70, 0.90), respectively. Meanwhile, a combined model that detected either ASD or VSD demonstrated a test AUC of 0.81 (95% CI, 0.76, 0.86), sensitivity of 0.73, specificity of 0.76, PPV of 0.14, and NPV of 0.98 (Figure 1). Conclusions: AI-enabled ECG models demonstrate promising performance in detecting ASD and VSD in pediatric patients. A combined model that detects either ASD or VSD also shows robust results. Future research should focus on multi-center validation of these models, refining their diagnostic capacities, and investigating their potential for early intervention in CHDs.
Abstract 18819: Detection of Systolic Dysfunction in Pediatric Patients Using an Artificial Intelligence-Enabled Electrocardiogram
Anjewierden, Scott , O’Sullivan, Donnchadh , Greason, Grace , Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18819 Get It

Introduction: Left and right ventricular systolic dysfunction (LVSD and RVSD respectively) contribute to considerable pediatric morbidity. Both LVSD and RVSD can occur in children before symptom onset, emphasizing the need for early detection. Existing deep-learning algorithms can identify LVSD in adults using 12-lead ECG; however, their efficacy in children is uncertain. Aims: We aimed to create a deep-learning model for LVSD and RVSD detection in pediatric patients using an AI-enabled ECG and compare novel pediatric models to a previously validated adult LVSD model. Methods: We identified 10,214 pediatric patients at the Mayo Clinic with a transthoracic echocardiogram (TTE) and a 10-second, 12-lead surface ECG within 14 days of TTE, performed from 2002 -2022. Our cohort comprised the first TTE-ECG pair from each patient, totaling 138 with EF ≤ 35%, 312 with EF ≤ 50%, 482 with RVSD, and 9,567 without any LVSD or RVSD. The cohort was split into training, validation, and testing datasets to develop neural networks for systolic dysfunction detection. Results: The cohort was 52.3% male, with an average age of 10.3 years. Novel models generated in the pediatric cohort demonstrated excellent performance in systolic dysfunction detection (Figure 1). Pediatric models for EF ≤ 35% and EF ≤ 50% achieved test AUCs of 0.92 (95% CI 0.89, 0.95) and 0.89 (95% CI 0.85, 0.94) respectively. The RVSD model reached a test AUC of 0.91 (95% CI 0.88, 0.94). A combined model for EF ≤ 35% or RVSD exhibited a test AUC of 0.90 (95% CI 0.87, 0.93), sensitivity 0.88, specificity 0.82, PPV 0.20, and NPV 0.95. A combined model for EF ≤ 50% or RVSD exhibited a test AUC of 0.88 (95% CI 0.85, 0.91). The previously validated adult data-derived model achieved an AUC of 0.86 (95% CI 0.83, 0.89) for EF ≤ 50% in children. Conclusions: AI-enabled ECGs demonstrate efficient detection of both LVSD and RVSD in pediatric patients. Future multi-site validation is needed to further establish the reliability of these models.
Abstract 18713: The Impact of ECG-AI Design Choices on Clinical Utility: A Deep Dive Into Left Ventricular Hypertrophy, Hypertrophic Cardiomyopathy, and Cardiac Amyloidosis
Asfahan, Shahir , Anto, Ausath, Verma, Shiva, Friedman, Paul A. , Barve, Rakesh , Siontis, Konstantinos C. , Anto, Ausath G., Gupta, Yash, Noseworthy, Peter A. , Attia, Zachi I. , López-Jiménez, Francisco , Awasthi, Samir

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18713 Get It

Introduction: Artificial intelligence applied to electrocardiograms (ECG-AI) enables early and efficient detection of cardiovascular disease. The technical and clinical impact of different approaches to designing ECG-AI remains under-explored. We consider left ventricular hypertrophy (LVH) and examine the impact of disease-specific labeling of minority etiologies of left ventricular wall thickening- hypertrophic cardiomyopathy (HCM) and cardiac amyloidosis (CA) - on ECG-AI performance. Hypothesis: ECG-AI designed to detect HCM or CA outperforms ECG-AI broadly trained to identify LVH due to differences in attention to key ECG features associated with HCM or CA. Methods: Independent neural networks were trained to identify HCM, CA, and LVH. HCM and CA patients were identified using the full depth of EHR data and validated via clinician adjudication (N = 3,025 and 4,251 patients, respectively). Moderate and severe LVH patients (N = 98,144) were identified using echocardiogram results and international LVH criteria. We compared the ability of disease-specific ECG-AI vs. LVH ECG-AI to detect HCM (or CA) by examining model performance within each of the three test sets. Results: 52.6% of HCM patients and 49.5% of CA patients met LVH criteria. Within the HCM test set, the AUROC, sensitivity, specificity, and positive predictive value (PPV) of the HCM ECG-AI were 0.94, 0.88, 0.85, and 60%, respectively, whereas the same for LVH ECG-AI were 0.83, 0.83, 0.64, and 37%. Within the CA test set, CA ECG-AI achieved AUROC, sensitivity, specificity, and PPV of 0.94, 0.81, 0.91, and 69%, respectively, whereas the same for LVH ECG-AI were 0.75, 0.73, 0.68, and 31%. ECGs positive for HCM exhibited higher P wave area, QRS deflection and R wave amplitude compared to LVH-positive ECGs (Cohen's D > 0.75). ECGs positive for CA exhibited lower R wave amplitude/area, QRS deflection and QRS areas (Cohen's D > 0.6). Conclusion: Models trained using carefully labeled HCM or CA identify distinct signals associated with the diseases, resulting in improved disease discrimination compared to a model trained to identify echocardiographic left ventricular thickening. Labeling choices should be communicated transparently to clinicians to ensure safe and effective use of ECG-AI.
Abstract 18324: Artificial Intelligence ECG as a Novel Method to Detect Cardiotoxicity After Anthracyclines
Jacobs, J. , Greason, Grace , Willems, Rik , Janssens, Stefan , Voigt, Jens‐Uwe , Friedman, Paul A. , Aelst, Lucas Van , Herrmann, Joerg , Jacobs, Johanna E J , Van Aelst, Lucas N L , Voigt, Jens-Uwe , Wildiers, Hans , Noseworthy, Peter A. , López-Jiménez, Francisco , Vandenberk, Bert , Attia, Zachi I.

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18324 Get It

Introduction: Cardiotoxicity is a serious side effect of anthracycline treatment, most commonly manifesting as a reduction in left ventricular ejection fraction (LVEF) on cardiac imaging. Cost-effective alternatives to cardiac imaging are currently not available. Artificial intelligence (AI) models have been developed to detect a reduced LVEF from 12-lead electrocardiograms (ECGs) in the general population. Hypothesis: AI-ECG model can detect a reduced LVEF after anthracycline therapy (i.e. cardiotoxicity). Methods: We included an unbiased oncological population of 989 female breast cancer patients receiving (neo)adjuvant anthracycline chemotherapy. Average follow-up time was 9.83±4.2 years. Patients with incomplete transthoracic echocardiography (TTE) data, HER-2-directed therapy, significant comorbidities, upfront metastatic disease, second primary malignancy or pre-existing cardiovascular disease were excluded from the analyses. Patients with LVEF decline for reasons other than anthracycline-induced cardiotoxicity were also excluded. Primary readout was the diagnostic performance of AI-ECG by area under the curve (AUC) for various levels of LVEF <50%. Results: Using 1,877 ECGs from 703 unique patients, the AI-ECG model detected an LVEF <50% and ≤35% after anthracycline therapy with an AUC of 0.93 and 0.94, respectively. Conclusions: These data support the use of AI-ECG for cardiomyopathy (cardiotoxicity) screening after anthracycline-based chemotherapy. This technology could serve as a gatekeeper to more costly testing and could enable patients to monitor themselves over long periods of time.
Abstract 18080: Pediatric Sex Detection Through AI-Enabled ECG Analysis: Evaluating Accuracy and the Influence of Pubertal Development
O’Sullivan, Donnchadh , Anjewierden, Scott , Greason, Grace , Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18080 Get It

Introduction: Biologic sex and hormonal concentrations shape ECG parameters due to sex hormone effects on cardiac function. AI-enabled ECGs have previously been shown to accurately predict patient sex in adults and correlate with sex hormone levels. Aims: We aimed to test the ability of AI-enabled ECGs to predict pediatric patient sex and explore the influence of pubertal development. Methods: Two AI-enabled ECG models were created using a convolutional neural network trained on pediatric 10-second, 12-lead surface ECGs. The first model was trained de novo using pediatric data. The second model used transfer learning from a previously validated adult data-derived algorithm. We analyzed the first ECG from 89,063 pediatric patients (aged <19 years) recorded from 1988-2022, and divided the cohort into training, validation, and testing datasets. Subgroup analysis was performed on prepubertal (0-7 years), pubertal (8-14 years), and post-pubertal (15-18 years) patients. Results: The cohort consisted of 46.6% males, with 21,434 prepubertal, 26,300 pubertal, and 41,329 post-pubertal children. No significant performance difference was observed between the two models. Both models demonstrated 81% accuracy and an overall AUC of 0.91 in the testing cohorts, with high discriminatory ability in post-pubertal teenagers (AUC = 0.98). (Figure 1) Conclusions: AI-ECG predicts pediatric patient sex with varying performance across pubertal stages. The highest discriminatory ability is observed post-puberty, decreasing in pubertal and prepubertal children. The results suggest hormonal and physiological changes during puberty may influence cardiac electrophysiology measurably. More research is required to interpret CNN-predicted sex discordance with actual sex and its implications for future cardiovascular risk.