B-018 Evaluation of a biological safety cabinet enclosed liquid handler for use in automating sterile cell culture preparation for T cell proliferation assays
Abstract Background Lymphocyte function and immune competence can be measured by proliferative response to stimuli and is useful in several clinical contexts including primary (or genetic) and secondary immunodeficiencies (e.g., immunosuppression following transplantation). Proliferation assays have traditionally been prepared manually due to the difficulty in maintaining the sterile environment required to prevent bacterial and fungal impact on cell growth. On most automated liquid handlers, the sample and reagents are placed inside a cabinet whose inner surfaces include rails, pullies, pumps, and circuitry that face the sample and are not amenable to sterilization. The Andrew+ (Waters, MA) is a small surface cleanable liquid handler with all machinery enclosed. We demonstrate here the use of an Andrew+ placed in a biological safety cabinet (BSC) to perform sterile assay setup. Methods Peripheral blood monocytes (PBMCs) from five individuals were manually generated via buffy coat isolation, then brought to standardized concentration. An Andrew+ was placed in a 4’ BSC and all surfaces disinfected with Oxivir Tb (Diversey, SC). The Andrew+ prepared three serial dilutions of two stimulant reagents (phytohemagglutinin (PHA) and pokeweed (PWM)), then dispensed stimulant and control reagents horizontally and PBMCs vertically to a 48 well plate. This process was duplicated manually from the same specimens to create a reference plate. The plates were incubated at 37°C and 5% CO2 for three days, then pulsed with EdU (Thermo Fisher, MA) and incubated for one additional day. Cells were harvested and counted via flow cytometry. Overall time and hands-on time were measured. Results A total of five samples were tested inside a using both manual and automation setup under eight conditions including with isotype control, media without stimulant, three concentrations of PHA, and three concentrations of PWM. The percent proliferation for various cell types as induced by each stimulant was calculated from the difference of the highest stimulant signal from the background (media-only) signal. Comparing the automated and manual method results showed a slope of 1.0217 and R2 of 0.9966. For a simulated run of 6 samples, technologist time for automated steps was under 8 minutes with a total time of 56 minutes. When these steps were performed manually, the time was 30 minutes. Automation increased total time by 26 minutes but saved 22 minutes of technologist hands-on time. Conclusion The Andrew+ was able to perform sterile setup of a cell culture assay. While slower overall than manual processing, technologist time was reduced. Ergonomic, inter-tech variability, and sample transcription error issues were subjectively observed to be less likely. The Andrew+ can work with up to four “dominos” (reagent or tip blocks) in width and up to three dominos in depth. Non-custom, standard depth BSCs from a variety of manufacturers (Labconco, Nuaire, ThermoFisher) have room for one domino in depth so, except for timings performed in this evaluation, all steps were broken down to be performed with a max of four dominos. Efficient sterile use of the system would require an extended depth BSC.
A-368 Point of Care Testing Expedites Treatments Provided by Community Paramedics
Abstract Background Community Paramedic (CP) programs use specially trained paramedics to provide healthcare in the community to increase access to care, reduce unnecessary emergency department visits, and improve timeliness of care. Mayo Clinic in Rochester, MN recently launched a CP Program to provide in-home care for patients who require regular intravenous medications, wound care, diuresis for heart failure, medication reconciliation, care plan compliance/education. CP utilizes i-STAT1 CHEM8+ and Lactate (CG4+) testing (Abbott Point of Care, Abbott Park, IL) to make therapy decisions primarily for heart failure patients based on rapid laboratory results. Having results available at the point of care (POC) eliminates delays between testing and treatments, expediting care for the patient. Prior to using i-STAT, CP traveled to the patient’s residence, drew blood tubes, delivered the tubes to Mayo Clinic, waited for test results, returned to the patient’s home, and provided treatment. In this observational study, we assessed the benefit of in-home POC i-STAT1 testing performed by our CP Program to improve patient care and increase efficiency. Methods Patients within a 40-mile radius of Mayo Clinic were eligible to receive CP service. Whole blood venous specimens were collected and tested using the i-STAT1 CHEM8+ metabolic panel cartridge according to manufacturer instructions to measure: ionized calcium, chloride, glucose, hematocrit, total carbon dioxide, blood urea nitrogen, creatinine, potassium, sodium, anion gap while the i-STAT1 CG4+ cartridge measures lactate. The laboratory information system was used to extract laboratory results, and Excel (Microsoft, Redmond, WA) was used to filter data and perform calculations. Results November 2022 through December 2024, CP performed testing with 353 i-STAT cartridges (3862 tests) on 102 unique patients who each had 1-12 separate orders. Patient ages were 25 to 97 years. 41.2% (1590/3862) of the individual results obtained were outside of our reference intervals (23.0% high, 18.0% low), with 10.8% being ionized calcium, 10.2% chloride, 10.3% glucose, 13.0% hematocrit, 7.6% total carbon dioxide, 18.2% blood urea nitrogen, 16.4% creatinine, 6.7% potassium and 6.9% sodium. Additionally, 0.13% of results were critically high (ionized calcium, potassium, and sodium) and 0.10% were critically low (potassium and ionized calcium). Hypokalemic patients were sent to the infusion therapy center for IV potassium. Patients experiencing hyperkalemia were retested and sent to the emergency department (ED). Hyponatremic and hypercalcemic patients were sent to the ED for further treatment. Abnormal (non-critical) results were reviewed by CP personnel to make treatment recommendations or medication adjustments. Conclusion i-STAT1 home testing performed by CP facilitated rapid therapeutic interventions and expedited decision-making. POC testing has increased the group’s efficiency—alleviating the need to transport specimens to the central laboratory and wait on test results before returning to the patient for treatment. Paramedicine emphasizes a proactive and preventative approach to medicine. We anticipate that this model of care and testing will expand to cover other chronic health conditions due to the program’s early success.
A-069 Comparison of Three Hemoglobin A1c Methodologies in Variant and Non-Variant Samples
Abstract Background Hemoglobin A1c is used to assess glycemic control to both diagnose and monitor diabetes mellitus. Several different methodologies are available including high performance liquid chromatography (HPLC), capillary electrophoresis (CE), and immunoassay (IA). These methods are standardized and traceable to the Diabetes Control and Complications Trial (DCCT). The aim of this study was to evaluate the difference in HbA1c results between methods and percent of reportable results in variant samples. Methods The HPLC (Bio-Rad Laboratories, Inc; D-100), the CE(Sebia Inc; Capillarys 3), and IA(Roche Diagnostics Inc; Tina-quant Generation 3) were compared using two sets of residual patient samples left after physician ordered testing was complete: 1) samples with an absence of abnormal hemoglobin peaks (i.e. non-variant) detected by HPLC; 2) samples with abnormal hemoglobin peaks (i.e. variant) characterized by hemoglobin electrophoresis performed clinically or lacking an A1c peak by HPLC/CE. The samples were tested within manufacturers stability claims. 317 non-variant samples were compared between the HPLC and CE methods. The absolute difference was calculated for each method using this equation (HbA1c%avg – HbA1c%X) where HbA1c%avg is the average of the methods that produced reportable results and X is the result from each method evaluated. Differences less than or equal to +/-0.3% were considered acceptable. 28 of the 317 non-variant and 47 variant samples were tested by all 3 methodologies. The 47 variant samples grouped into 3 cohorts: common heterozygous variants (HbC, HbD, HbE, HbS and HbF, n=10), uncommon heterozygous variants (n=29) and homozygous variants lacking HbA (n=8). The absolute differences in variant sample results were calculated for samples that did not surpass manufacturer’s claims for producing an accurate result. The frequency of producing a numeric result in variant samples was calculated for each method. Results The HPLC/CE non-variant sample comparison (N=317) had results spanning the measuring range (3.8% - 14.0%) with average(range) of absolute difference=0.1(-0.4to0.6%) with 293/317(92.4%) samples within +/-0.3%. The HPLC/CE/IA non-variant sample comparison (N=28) had a result range=4.0%-9.4%, the average(range) of difference=0.1(-0.2to0.5%) with 25/28 (89.2%) of samples within +/-0.3%. Common heterozygous variant samples gave numeric results with no disqualifying flags in 9 of 10(HPLC), 8 of 10(CE), and 9 of 10(IA) samples tested. The average(range) difference from average=0.0(-0.3,0.5%) for HPLC, 0.0(-0.2,0.3%) for CE, and -0.1(-0.6,0.2%) for IA. Uncommon variant samples gave results in 4 of 29 (HPLC), 20 of 29 (CE), and 26 of 29 (IA) of samples tested. The average(range) difference from average=-0.1(-0.3,0.1%) for HPLC, 0.0(-1.0,1.1%) for CE, and 0.0(-1.1,1.0%) for IA. The homozygous variant (no HbA) samples gave results in 0 of 8 (HPLC), 0 of 8 (CE), and 4 of 8 (IA) of those tested. Conclusion All three methods meet their claims for accurately measuring hemoglobin A1c from non-variant and common hemoglobin variants. The advantage of HPLC and CE is the ability to identify hemoglobin variants that may impact HbA1c quantitation. The IA method provides the most numeric results. IA gave results even when HbA was absent. The lab should understand the capabilities and limitations of their HbA1c method on the population served.
Microsurgical obliteration of a superior petrosal dural arteriovenous fistula presenting with a symptomatic brainstem cavernous malformation
In this video, the authors present the microsurgical treatment of a superior petrosal dural arteriovenous fistula (dAVF) associated with a symptomatic hemorrhagic brainstem cavernous malformation in a 38-year-old male. The patient underwent a retrosigmoid craniotomy for cavernoma evacuation and fistula disconnection. Intraoperative indocyanine green angiography revealed cortical venous reflux not evident on catheter angiography, prompting reclassification to a higher-grade fistula. Postoperatively, the patient returned to neurological baseline, and follow-up imaging confirmed complete fistula obliteration, cavernoma resection, and new appearance of a developmental venous anomaly (DVA). This case highlights the dynamic nature of dAVF venous drainage and illustrates the rare co-occurrence of dAVF, DVA, and brainstem cavernoma. The video can be found here: https://stream.cadmore.media/r10.3171/2025.7.FOCVID2553
Calibration of multisite raters for prospective visual reads of amyloid PET scans
Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’ κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’ κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen's κ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.
Leptomeningeal Metastatic Disease: Patient Characteristics and Symptom Burden at a Large Tertiary Referral Center
PURPOSE Leptomeningeal metastatic disease (LMD) is associated with poor prognosis and imposes severe symptomatic limitations on functional status and quality of life. In recent years, the range of diagnostic and therapeutic options available to patients with LMD has expanded, but the impact of these innovations on clinical characteristics and outcomes remains unclear. We conducted a retrospective study to define the LMD patient population, symptoms experienced, and the frequency of accessing specialty palliative care (PC) services, at a large tertiary referral center. METHODS We conducted a retrospective electronic medical record review on the basis of a convenience sample of 104 patients diagnosed and treated with LMD with dates of diagnosis between January 1, 2016, and October 1, 2022. Variables were generated on the basis of patient demographics, reported symptoms, and clinical course. Data were analyzed using Stata 16. RESULTS Of 104 patients in the analysis, the most common symptoms reported were headache and extremity weakness (52% of patients reported each). The mean number of weeks between LMD diagnosis and date of death was 41.4, with a median of 27.9 weeks, and a range of 1.4-143.4 weeks. Forty-five percent of patients had at least one documented visit with an inpatient or outpatient PC provider. CONCLUSION Patients with an LMD diagnosis face a high symptom burden. Our findings highlight that prognosis may be longer than what is typically quoted in the literature, but further study would be needed to understand this discrepancy. Fewer than half of the patients in our sample had a documented visit with a PC specialist, suggesting a missed opportunity in this population to connect with providers specialized in managing symptom burden and doing nuanced advance care planning.
International, Multispecialty Expert Consensus on Nomenclature for Facial Paralysis
Background: Variable terminology is used in the literature to describe facial synkinesis and hypertonicity following incomplete recovery from facial paralysis and its associated medical and surgical treatments. Study Objectives: Establish a nomenclature consensus for this condition among a group of facial nerve experts. Design Type: Consensus study. Methods: Using modified Delphi methodology, an international, multidisciplinary group of facial nerve experts reviewed the terminology for the name of the clinical condition and treatments of interest. Online surveys and a virtual discussion were performed to establish consensus, defined a priori as agreement by 80% of the group. Results: Twenty-five facial nerve experts established consensus after three Delphi rounds. Consensus terminology for the condition is “facial synkinesis” with 84% agreement. Medical treatment is termed “chemodenervation” with 100% agreement. Surgical treatments including “selective facial neurectomy,” “selective facial neurotomy,” “selective facial myectomy,” and “selective facial myotomy,” were defined and reached agreement of 100%. Conclusions: This international group of facial nerve experts has recommended standardized nomenclature for the condition of facial synkinesis and its various treatments. While “facial synkinesis” reached consensus as the preferred term, some experts noted it may insufficiently describe the full clinical spectrum, which includes muscle hypertonicity, weakness, and spontaneous twitching.
Defining the MYC-regulated transcriptome and kinome that support KRAS- and ERK-dependent growth of pancreatic cancer
Of the thousands of genes and substrates identified in KRAS-mutant signaling networks in pancreatic ductal adenocarcinoma (PDAC), more than 200 are transcription factors, implying extensive and complex transcriptional regulation. However, we observed that genetic suppression of the transcription factor MYC alone was sufficient to phenocopy the effect of KRAS suppression in signaling, growth, and metabolic processes in PDAC cells. We determined the gene transcription changes caused by acute suppression of MYC function in KRAS -mutant PDAC cell lines and performed dependency map and pathway analyses on the affected gene sets. The expression of 1685 genes was increased upon suppression of MYC, and this gene set may comprise the bulk of the MYC-regulated genes essential for PDAC growth. In contrast, the 1325 genes whose expression was inhibited may comprise a compensatory response to oncogenic stress, mediated in part by the GTPase RHO. MYC-dependent transcriptional activity was largely ERK dependent, and almost one-third of ERK-regulated genes were also regulated by MYC in PDAC cells. Furthermore, chemical proteomic profiling revealed MYC-regulated protein kinases that can be targeted therapeutically. Together, these data provide a molecular portrait of MYC-dependent signaling that encompasses potentially exploitable mechanisms for treating PDAC.
Physical activity and molecular subtypes of colorectal cancer: a pooled observational analysis and Mendelian randomization study
Abstract Background Physical activity is associated with lower colorectal cancer (CRC) risk, but its association with molecular subtypes defined by genetic and epigenetic alterations of the disease is unclear. Such information may enhance the understanding of the mechanisms related to the benefits of physical activity. Methods Pooled observational (cases: n = 5386; controls: n = 6798; studies n = 5) and genome-wide association data (cases: n = 8178; controls: n = 10 472; studies n = 5) were used. We used multivariable logistic regression models and Mendelian randomization to assess the association between physical activity and the risk of CRC subtypes defined by individual tumor markers (and marker combinations), namely microsatellite instability status, CpG island methylator phenotype status, and BRAF and KRAS mutations. We used case-only analysis to test for differences between molecular subtypes. We applied Bonferroni correction to account for multiple tests. Results In the pooled observational analysis, higher levels of physical activity were associated with lower CRC risk (Obs-per 1SD, odds ratio [OR] = 0.94, 95% confidence interval [CI] = 0.90 to 0.97), with an association that was stronger in males (Obs-per 1SD, OR = 0.91, 95% CI = 0.87 to 0.96) than in females (Obs-per 1SD, OR = 0.97, 95% CI = 0.91 to 1.03; Pinteraction = .04). Higher physical activity was associated with a lower risk of CRC across all molecular subtypes, especially in males. There was no difference in the associations by subtypes by pooled observational or Mendelian randomization analyses. The findings did not differ by study design, anatomical site, and early or late age onset of CRC. Conclusions Our findings suggest that physical activity is not differentially associated with the 4 major molecular subtypes involved in colorectal carcinogenesis, indicating that its benefits extend broadly across colorectal cancer pathogenesis.
Primary Lateral Sclerosis Natural History Study:
Primary Lateral Sclerosis Functional Rating Scale
and Other Outcomes Assessment
Objective The primary lateral sclerosis ( PLS ) consensus diagnostic criteria and functional rating scale ( PLSFRS ) were recently established to facilitate and optimize future PLS clinical trials. We examined the trajectory of the PLSFRS and other functional outcome measures and biomarkers in the PLS Natural History Study ( PLS NHS ) to understand their performance in this prospective cohort. Methods The PLS NHS is a prospective, longitudinal, multicenter study of people living with PLS in different diagnostic categories: early (disease duration <2 years); probable (2–4 years); and definite PLS (4–15 years). PLSFRS scores and other functional outcome measures were collected at baseline, 3‐, 6‐, 9‐, and 12‐month follow‐up visits. Baseline characteristics were compared between the groups. The slopes of the PLSFRS and other functional outcome measures over 12 months were examined in the overall cohort and subgroups using linear mixed‐effect models. The associations between baseline characteristics and the rate of PLSFRS decline were analyzed with linear regression models. Results A total of 76 participants were included: early (n = 6); probable (n = 26); and definite (n = 44) PLS . Baseline PLSFRS total scores were highest in the early PLS group, followed by the probable and definite PLS groups. In the overall cohort, the PLSFRS total score declined by 0.33 points/month (95% confidence interval [0.27–0.39], adjusted p < 0.05). The rate of decline was steepest in the early PLS group, followed by the probable and definite PLS groups. Baseline neurofilament light chain level was associated with the rate of PLSFRS decline over 1 year ( p = 0.001). Interpretation In PLS, the rate of functional decline, as measured by the PLSFRS total score, is faster during the early phase of the disease. Neurofilament light might serve as a prognostic biomarker in PLS. ANN NEUROL 2026;99:418–428