Citations

Clear

192 citation(s) found for "Johnson, Bruce".

Interaction of hypoxia and vascular occlusion on cardiorespiratory responses during exercise
Keller‐Ross, Manda L. , Sarkinen, Andrielle L., Chantigian, Daniel P. , Johnson, Bruce D., Olson, Thomas P. , Keller-Ross, Manda , Cross, Troy J.

Mayo Clinic

Translational Sports Medicine | November 27, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/tsm2.60 Get It

Pulmonary Function Assessment Post-Left Ventricular Assist Device Implantation
Sajgalik, Pavol , Kim, Chul‐Ho , Stulak, John M., Kushwaha, Sudhir S. , Maltais, Simon, Joyce, David L. , Joyce, Lyle D., Johnson, Bruce D. , Schirger, John A.

Mayo Clinic

ESC Heart Failure | October 12, 2018 | Volume: 6 | Issue: 1 | Pages: 53-61

10.1002/ehf2.12348 | PMID 30311748 Get It

Abstract Aim The lungs—and particularly the alveolar-capillary membrane—may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function. Methods and results We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)] and diffusing capacity of the lung for carbon monoxide (DLCO) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (−23%) since pre-implantation (P < 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P < 0.01) and ΔDLCO to ΔRAP (r = 0.39, P < 0.05). We observed other reductions in FEV1, FVC, and FEV1/FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1/FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28–0.98); P = 0.03]. Conclusions Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.
Age-dependent effects of thoracic and capillary blood volume distribution on pulmonary artery pressure and lung diffusing capacity
Coffman, Kirsten E. , Boeker, Matthew G., Carlson, Alex R. , Johnson, Bruce D.

Mayo Clinic

Physiological Reports | September 2, 2018 | Volume: 6 | Issue: 17 | Pages: e13834

10.14814/phy2.13834 | PMID 30175463 Get It

Tension-Controlled Active Compression Garment for Treatment of Orthostatic Intolerance
Pettys‐Baker, Robert, Schleif, Nicholas, Lee, J. Walter, Utset-Ward, Sophia, Berglund, Mary Ellen, Dunne, Lucy E. , Holschuh, Brad , Kelly, Kevin L. , Johnson, Bruce , Joyner, Michael J. , Joyner, Michael J , Johnson, Christopher D.

Mayo Clinic

2018 Design of Medical Devices Conference | July 30, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2018-6884 Get It

Medical compression garments are used to treat lymphatic disorders or conditions of poor venous return (e.g. orthostatic intolerance). Conventional compression garments, namely elastic compression sleeves and inflatable compression systems, may aid in relief of these conditions but are also limited in usability. Fixed levels of compression in elastic materials may induce challenges in donning/doffing, complicating patient compliance [1]. Compression levels in inflatable systems are customizable, but these garments are also bulky and require a tethered inflation source [2]. We are interested in developing easy-to-don/-doff compression garments using shape memory alloy (SMA) coil actuators that contract with heat from an applied current which can be wrapped around the body to apply compressive forces. More specifically, we use a spring coil formation as described by Holschuh et al. [3]. Further developed in the Wearable Technology Lab at the University of Minnesota, our current SMA compression garment (SMA-CG) design improves upon the work of Duvall et al. [4] presented in previous year’s (2017) Design of Medical Devices Conference, representing a year’s evolution in active compression garment design that integrate actuators made with SMA.
Exhaled Nitric Oxide Changes During Acclimatization to High Altitude: A Descriptive Study
Summerfield, Douglas T. , Coffman, Kirsten E. , Taylor, Bryan J. , Issa, Amine, Johnson, Bruce D., Issa, Amine N, Taylor, Bryan J

Mayo Clinic

High Altitude Medicine & Biology | May 14, 2018 | Volume: 19 | Issue: 3 | Pages: 215-220

10.1089/ham.2017.0109 | PMID 29757001 Get It

Streamlining cardiopulmonary exercise testing for use as a screening and tracking tool in primary care
Kim, Chul‐Ho , Iterson, Erik H. Van , Hansen, James E. , MacCarter, Dean, Johnson, Bruce D. , MacCarter, Dean J, Van Iterson, Erik H

Mayo Clinic

Pulmonary Circulation | April 25, 2018 | Volume: 8 | Issue: 2 | Pages: 1-8

10.1177/2045894018776489 | PMID 29693481 Get It

Cardiopulmonary exercise testing (CPET) using a spectrum of different approaches demonstrates usefulness for objectively assessing patient disease severity in clinical and research settings. Still, an absence of trained specialists and/or improper data interpretation techniques can pose major limitations to the effective use of CPET for the clinical classification of patients. This study aimed to test an automated disease likelihood scoring algorithm system based on cardiopulmonary responses during a simplified step‐test protocol. For patients with heart failure (HF), pulmonary hypertension (PAH), obstructive lung disease (OLD), or restrictive lung disease (RLD), we compared patient scores stratified into one of four “silos” generated from our novel algorithm system against patient evaluations provided by expert clinicians. Patients with HF (n = 12), PAH (n = 9), OLD (n = 16), or RLD (n = 10) performed baseline pulmonary function testing followed by submaximal step‐testing. Breath‐by‐breath measures of ventilation and gas exchange, in addition to oxygen saturation and heart rate were collected continuously throughout testing. The algorithm demonstrated close alignment with patient assessments provided by clinical specialists: HF (r = 0.89, P < 0.01); PAH (r = 0.88, P < 0.01); OLD (r = 0.70, P < 0.01); and RLD (r = 0.88, P < 0.01). Furthermore, the algorithm was capable of differentiating major disease from other disease pathologies. Thus, in a clinically relevant manner, these data suggest this simplified automated disease algorithm scoring system used during step‐testing to identify the likelihood that patients have HF, PAH, OLD, or RLD closely correlates with patient assessments conducted by trained clinicians.
Resistive and elastic work of breathing in older and younger adults during exercise
Smith, Joshua R. , Cross, Troy J. , Iterson, Erik H. Van , Johnson, Bruce D. , Olson, Thomas P. , Van Iterson, Erik H , Smith, Joshua R , Cross, Troy James

Mayo Clinic

Journal of Applied Physiology | April 19, 2018 | Volume: 125 | Issue: 1 | Pages: 190-197

10.1152/japplphysiol.01105.2017 | PMID 29672228 Get It

It is unknown whether the greater total work of breathing (WOB) with aging is due to greater elastic and/or resistive WOB. We hypothesized that older compared with younger adults would exhibit a greater total WOB at matched ventilations (V̇e) during graded exercise, secondary to greater inspiratory resistive and elastic as well as expiratory resistive WOB. Older (OA: 60 ± 8 yr; n = 9) and younger (YA: 38 ± 7 yr; n = 9) adults performed an incremental cycling test to volitional fatigue. Esophageal pressure, inspiratory (IRV) and expiratory reserve volumes (ERV), expiratory flow limitation (EFL), and ventilatory variables were measured at matched V̇e (i.e., 25, 50, and 75 l/min) during exercise. The inspiratory resistive and elastic as well as expiratory resistive WOB were quantified using the Otis method. At V̇e of 75 l/min, older adults had greater %EFL and larger tidal volumes to inspiratory capacity but smaller relative IRV ( P ≤ 0.03) than younger adults. Older compared with younger adults had greater total WOB at V̇Eof 50 and 75 l/min (OA: 90 ± 43 vs. YA: 49 ± 21 J/min; P < 0.04 for both). At V̇e of 75 l/min, older adults had greater inspiratory elastic and resistive WOB (OA: 44 ± 27 vs. YA: 24 ± 22 and OA: 23 ± 15 vs. YA: 11 ± 3 J/min, respectively, P < 0.03 for both) and expiratory resistive WOB (OA: 23 ± 19 vs. YA: 14 ± 9 J/min, P = 0.02) than younger adults. These data demonstrate that aging-induced pulmonary alterations result in greater inspiratory elastic and resistive as well as expiratory resistive WOB, which may have implications for the integrated response during exercise.NEW & NOTEWORTHY Aging-induced changes to the pulmonary system result in increased work of breathing (WOB) during exercise. However, it is not known whether this higher WOB with aging is due to differences in elastic and/or resistive WOB. Herein, we demonstrate that older adults exhibited greater inspiratory elastic and resistive as well as expiratory resistive WOB during exercise.
The influence of thoracic gas compression and airflow density dependence on the assessment of pulmonary function at high altitude
Cross, Troy J. , Wheatley, Courtney M. , Stewart, Glenn M. , Coffman, Kirsten E. , Carlson, Alex R. , Morris, Norman , Johnson, Bruce D. , Wheatley, Courtney, Coffman, Kirsten, Carlson, Alex, Stepánek, Jan , Cross, Troy James , Stepánek, Jan

Mayo Clinic

Physiological Reports | April 1, 2018 | Volume: 6 | Issue: 6 | Pages: e13576

10.14814/phy2.13576 | PMID 29595881 Get It

Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
Sajgalik, Pavol , Křemen, Václav , Fabián, Vratislav , Maltais, Simon, Stulak, John M., Kushwaha, Sudhir S. , Joyce, Lyle D., Schirger, John A., Johnson, Bruce D. , Kremen, Vaclav

Mayo Clinic

ASAIO Journal | March 14, 2018 | Volume: 65 | Issue: 2 | Pages: 127-133

10.1097/mat.0000000000000775 | PMID 29538016 Get It

The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland–Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement “success rate” expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
The influence of pulmonary vascular pressures on lung diffusing capacity during incremental exercise in healthy aging
Coffman, Kirsten E. , Curry, Timothy B. , Dietz, Niki M., Chase, Steven C. , Carlson, Alex R. , Ziegler, Briana, Johnson, Bruce D. , Ziegler, Briana L

Mayo Clinic

Physiological Reports | January 30, 2018 | Volume: 6 | Issue: 2 | Pages: e13565

10.14814/phy2.13565 | PMID 29368799 Get It