Citations

Clear

1825 citation(s) found for "Yu, Emily".

Genetic screening of a large series of North American sporadic and familial frontotemporal dementia cases
Ramos, Eliana Marisa , Dokuru, Deepika , Berlo, Victoria Van, Wojta, Kevin , Huang, Alden , Deverasetty, Sandeep, Qin, Yue , Blitterswijk, Marka van , Jackson, Jazmyne L. , Bordelon, Yvette , Brannelly, Patrick , Brushaber, Danielle , Dickinson, Susan, Domoto‐Reilly, Kimiko , Faber, Kelley , Fields, Julie A. , Forsberg, Leah K. , Gavrilova, Ralitza H. , Ghoshal, Nupur , Graff‐Radford, Jonathan , Graff‐Radford, Neill R. , Grant, Ian , Heuer, Hilary W. , Hsiung, Ging‐Yuek Robin , Huey, Edward D. , Irwin, David J. , Kantarci, Kejal , Karydas, Anna, Kaufer, Daniel , Kornak, John , Kramer, Joel H. , Kremers, Walter K. , Kukull, Walter A. , Ljubenkov, Peter A. , Lungu, Codrin , Mackenzie, Ian R. , Mendez, Mario F. , Miller, Bruce L. , Onyike, Chiadi U. , Pantelyat, Alexander , Pearlman, Rodney , Petrucelli, Len, Potter, Madeline, Rankin, Katherine P. , Rascovsky, Katya, Roberson, Erik D. , Rogalskı, Emily , Shaw, Leslie M. , Syrjanen, Jeremy A. , Tartaglia, Maria Carmela , Tatton, Nadine , Taylor, Joanne, Trojanowski, John Q. , Weıntraub, Sandra , Wong, Bonnie , Rademakers, Rosa , Rosen, Howard J. , Boxer, Adam L. , Coppola, Giovanni, Jackson, Jazmyne, Brushaber, Danielle E, Boeve, Brad F, van Blitterswijk, Marka , Irwin, David J , Hsiung, Gink-Yuek , Roberson, Erik , Miller, Bruce L , Kantarci, Kejal , Pantelyat, Alex , Tartaglia, Maria Carmela , Kremers, Walter K , Domoto-Reilly, Kimiko , Wang, Qing , Appleby, Brian S. , Dickerson, Bradford Clark , Fong, Jamie , Foroud, Tatiana , Goldman, Jill , Grossman, Murray , Kerwin, Diana , Knopman, David S. , Litvan, Irene , Toga, Arthur W. , Wszołek, Zbigniew K. , Boeve, Bradley F. , Coppola, Giovanni

Mayo Clinic

Alzheimer's & Dementia | January 16, 2020 | Volume: 16 | Issue: 1 | Pages: 118-130

10.1002/alz.12011 | PMID 31914217 Get It

AbstractIntroductionThe Advancing Research and Treatment for Frontotemporal Lobar Degeneration (ARTFL) and Longitudinal Evaluation of Familial Frontotemporal Dementia Subjects (LEFFTDS) consortia are two closely connected studies, involving multiple North American centers that evaluate both sporadic and familial frontotemporal dementia (FTD) participants and study longitudinal changes.MethodsWe screened the major dementia‐associated genes in 302 sporadic and 390 familial (symptomatic or at‐risk) participants enrolled in these studies.ResultsAmong the sporadic patients, 16 (5.3%) carried chromosome 9 open reading frame 72 (C9orf72), microtubule‐associated protein tau (MAPT), and progranulin (GRN) pathogenic variants, whereas in the familial series we identified 207 carriers from 146 families. Of interest, one patient was found to carry a homozygous C9orf72 expansion, while another carried both a C9orf72 expansion and a GRN pathogenic variant. We also identified likely pathogenic variants in the TAR DNA binding protein (TARDBP), presenilin 1 (PSEN1), and valosin containing protein (VCP) genes, and a subset of variants of unknown significance in other rare FTD genes.DiscussionOur study reports the genetic characterization of a large FTD series and supports an unbiased sequencing screen, irrespective of clinical presentation or family history.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Mayo Clinic

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 | PMID 31937608 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c <10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P < 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P < 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
Cockerill, Franklin R., Reed, G S, Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Dale, J C, Roberts, Glenn D., Ilstrup, D M, Henry, Nancy K., Hughes, J G

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 6 | Pages: 1469-1472

10.1128/jcm.35.6.1469-1472.1997 | PMID 9163464 Get It

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.
Clinical comparison of isolator, Septi-Chek, nonvented tryptic soy broth, and direct agar plating combined with thioglycolate broth for diagnosing spontaneous bacterial peritonitis
Hay, J. Eileen, Cockerill, Franklin R., Kaese, D, Vetter, Emily A., Wollan, Peter C. , Rakela, J., Wilhelm, Mark

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 34-37

10.1128/jcm.34.1.34-37.1996 | PMID 8748267 Get It

Spontaneous bacterial peritonitis is a life-threatening complication of cirrhotic ascites. Optimal patient management depends on the isolation of the causal organism from ascitic fluid. To evaluate culture techniques for the diagnosis of spontaneous bacterial peritonitis, we prospectively compared three blood culture system, the Isolator system, a lysis-centrifugation system, the Septi-Chek system, a biphasic culture system, and a nonvented tryptic soy broth system, all inoculated at the bedside, and our standard method of direct inoculation of specimens after transport to the laboratory onto agar plates and into thioglycolate broth. The results showed that the Septi-Chek and nonvented tryptic soy broth systems each recovered statistically significantly more pathogens than either the Isolator system (P = 0.0084) or the standard method (P = 0.00098). The Isolator system recovered more pathogens than the standard plate method, but this difference was not statistically significant. Both the Isolator system and the standard plate method recovered more contaminating microorganisms than the Septi-Chek or nonvented tryptic soy broth system. The Isolator system required the most processing time compared with the processing times required by any other method.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 | PMID 8748264 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Evaluation of an immunoassay for direct detection of Escherichia coli O157 in stool specimens
Dylla, Brenda L., Vetter, Emily A., Cockerill, Franklin R., Hughes, J G

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 1 | Pages: 222-224

10.1128/jcm.33.1.222-224.1995 | PMID 7535313 Get It

An enzyme-linked immunosorbent assay (ELISA) produced by LMD Laboratories, Inc., Carlsbad, Calif., was compared with culture for the detection of Escherichia coli O157. Nine of 185 stool specimens evaluated had positive results by the LMD E. coli O157 ELISA and grew E. coli O157 on culture; 174 had negative by LMD E. coli O157 ELISA results and did not grow E. coli O157 on culture. Of 174 specimens negative by LMD E. coli O157 ELISA, 117 specimens grew other enteric pathogens: Campylobacter spp. (46 isolates), Salmonella spp. (43 isolates), Yersinia spp. (20 isolates), and Shigella spp. (8 isolates). There were two indeterminant results by the LMD E. coli O157 ELISA. One stool specimen did not grow other enteric pathogens on culture, and one grew a Campylobacter sp. on culture. Both had negative LMD E. coli O157 ELISA results upon repeat testing. The LMD E. coli O157 ELISA is an accurate, easy-to-read screening method for the detection of E. coli O157 in fecal specimens.
Diffuse Right Ventricular Fibrosis in Heart Failure with Preserved Ejection Fraction and Pulmonary Hypertension
Patel, Ravi B. , Li, Emily , Benefield, Brandon , Swat, Stanley , Polsinelli, Vincenzo B. , Carr, James , Shah, Sanjiv J. , Markl, Michael , Freed, Benjamin H. , Collins, Jeremy D. , Markl, Michael , Shah, Sanjiv J , Patel, Ravi B , Freed, Benjamin H

Mayo Clinic

ESC Heart Failure | January 6, 2020 | Volume: 7 | Issue: 1 | Pages: 254-264

10.1002/ehf2.12565 | PMID 31903694 Get It

Abstract Aims While right ventricular (RV) dysfunction is associated with worse prognosis in co-morbid pulmonary hypertension and heart failure with preserved ejection fraction (PH-HFpEF), the mechanisms driving RV dysfunction are unclear. We evaluated the extent and clinical correlates of diffuse RV myocardial fibrosis in PH-HFpEF, as measured by cardiovascular magnetic resonance-derived extracellular volume (ECV). Methods and results We prospectively enrolled participants with PH-HFpEF (n = 14), pulmonary arterial hypertension (PAH; n = 13), and controls (n = 8). All participants underwent high-resolution cardiovascular magnetic resonance, and case subjects (PH-HFpEF and PAH) additionally underwent right heart catheterization. T1 mapping was performed using high-resolution modified look-locker inversion recovery with a 1 × 1 mm2 in-plane resolution. RV free wall T1 values were quantified, and ECV was calculated. Participants with PH-HFpEF were older and carried higher rates of hypertension and obstructive sleep apnoea than those with PAH. While RV ECV was similar between PH-HFpEF and PAH (33.1 ± 8.0 vs. 34.0 ± 4.5%; P = 0.57), total pulmonary resistance was lower in PH-HFpEF compared with PAH [PH-HFpEF: 5.68 WU (4.70, 7.66 WU) vs. PAH: 8.59 WU (8.14, 12.57 WU); P = 0.01]. RV ECV in PH-HFpEF was associated with worse indices of RV structure (RV end-diastolic volume: r = 0.67, P = 0.01) and RV function (RV free wall strain: r = 0.59, P = 0.03) but was not associated with RV afterload (total pulmonary resistance: r = 0.08, P = 0.79). Conversely, there was a strong correlation between RV ECV and RV afterload in PAH (r = 0.57, P = 0.04). Conclusions Diffuse RV fibrosis, as measured by ECV, is present in PH-HFpEF and is associated with adverse RV structural and functional remodelling but not degree of pulmonary vasculopathy. In PH-HFpEF, diffuse RV fibrosis may occur out of proportion to the degree of RV afterload.
Evaluation of two rapid antigen assays, BioStar Strep A OIA and Pacific Biotech CARDS O.S., and culture for detection of group A streptococci in throat swabs
Dale, J C, Vetter, Emily A., Contezac, Joan M., Iverson, L. K., Wollan, Peter C. , Cockerill, Franklin R.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 11 | Pages: 2698-2701

10.1128/jcm.32.11.2698-2701.1994 | PMID 7852559 Get It

Two rapid methods, BioStar Strep A OIA (OIA; BioStar, Inc., Boulder, Colo.), an optical immunoassay, and CARDS O.S. (O.S.; Pacific Biotech, Inc., San Diego, Calif.), a color immunochromographic assay, and two culture methods, one with 5% sheep blood agar (SBA) and one with Todd-Hewitt broth (TH; Remel, Lenexa, Kans.), were evaluated for use in the detection of Streptococcus pyogenes from pharnygeal swabs. Seven hundred forty-six double swabs (Culturette II) were processed, with OIA and SBA culture performed on one swab and O.S. and SBA culture performed on the other swab. The pledget from the Culturette II was incubated overnight in TH and was subcultured onto SBA for an additional 48 h in ambient air. All beta-hemolytic streptococci from culture were tested by a direct fluorescent-antibody test (Difco Laboratories, Detroit, Mich.). Specimens with discordant fluorescent-antibody test and rapid test results were also tested by using the Streptex latex agglutination reagent (Murex Diagnostics Limited, Dartford, England). The results obtained by all testing methods were compared with a combined test result ("gold standard"), which was defined as any positive culture detected by the SBA or TH culture methods and confirmed by Streptex latex agglutination or, in the case of negative results by both culture methods, a concomitant positive result by OIA and O.S. antigen testing. Sensitivity and specificity results for each of the methods were as follows, respectively: OIA, 81.0 and 97.5%; O.S., 74.4 and 99.0%; SBA culture, 92.3 and 98.3%; and TH culture, 86.4 and 100%. Both OIA and O.S. are suitable screening methods for detecting S. pyogenes directly from throat swabs but are of insufficient sensitivity to eliminate the need for backup cultures for specimens with negative OIA and O.S. results.
Comparison of Gen-Probe Group A streptococcus Direct Test with culture for diagnosing streptococcal pharyngitis
Pokorski, S J, Vetter, Emily A., Wollan, Peter C. , Cockerill, Franklin R.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 6 | Pages: 1440-1443

10.1128/jcm.32.6.1440-1443.1994 | PMID 8077386 Get It

The Group A Streptococcus Direct Test (GP-ST test; Gen-Probe, Inc., San Diego, Calif.) was compared with culture for the detection of Streptococcus pyogenes from throat swabs of 767 patients with pharyngitis. Swabs were tested by the GP-ST test after inoculating a 5% sheep blood agar (SBA) plate. SBA plates were incubated at 35 degrees C in room air for 72 h. SBA plates with no evidence of beta-hemolytic colonies after 18 to 24 h of incubation were subcultured by taking a swipe across the primary inoculum from the SBA plate to an agar selective for Streptococcus spp. In a low-prevalence (11.9%) population and in comparison with the number of positive cultures detected by the 72-h single-culture method (SBA plate method), the GP-ST test had a sensitivity of 88.6%, a specificity of 97.8%, a positive predictive value of 83.9%, and a negative predictive value of 98.5%. In comparison with the growth of any colonies of S. pyogenes on the 72-h SBA plates plus a subculture onto selective blood agar, the sensitivities and specificities were as follows: 72-h SBA plate method, 96.7 and 100%, respectively; GP-ST test, 85.7 and 97.8%, respectively. The GP-ST test is an easy-to-perform, reliable test for batch screening of throat swabs for S. pyogenes.
Correlative Analyses of the SARC028 Trial Reveal an Association Between Sarcoma-Associated Immune Infiltrate and Response to Pembrolizumab
Keung, Emily Z. , Salazar, Ruth , Rodrigues-Canales, Jaime, Bolejack, Vanessa , Tine, Brian A. Van , Schuetze, Scott M. , Attia, Steven , Riedel, Richard F. , Hu, James , Okuno, Scott H. , Priebat, Dennis A., Movva, Sujana , Davis, Lara E. , Wang, Wei‐Lien , Wargo, Jennifer A. , Tawbi, Hussein A. , Bolejack, Vanessa , Van Tine, Brian A , Schuetze, Scott M , Riedel, Richard F , Okuno, Scott , Davis, Lara E , Reed, Damon R , Reuben, Alexandre , Lazar, Alexander J , Burgess, Melissa , Parra, Edwin Roger , Reed, Damon R. , Roland, Christina Lynn , Reinke, Denise K. , Lazar, Alexander J.

Mayo Clinic

Clinical Cancer Research | January 3, 2020 | Volume: 26 | Issue: 6 | Pages: 1258-1266

10.1158/1078-0432.ccr-19-1824 | PMID 31900276 Get It

Abstract Purpose: We recently reported a 17.5% objective RECIST 1.1 response rate in a phase II study of pembrolizumab in patients with advanced sarcoma (SARC028). The majority of responses occurred in undifferentiated pleomorphic sarcoma (UPS) and dedifferentiated liposarcoma (DDLPS). We sought to determine whether we can identify immune features that correlate with clinical outcomes from tumor tissues obtained pre- and on-treatment. Patients and Methods: Pretreatment (n = 78) and 8-week on-treatment (n = 68) tumor biopsies were stained for PD-L1 and multiplex immunofluorescence panels. The density of positive cells was quantified to determine associations with anti–PD-1 response. Results: Patients that responded to pembrolizumab were more likely to have higher densities of activated T cells (CD8+ CD3+ PD-1+) and increased percentage of tumor-associated macrophages (TAM) expressing PD-L1 pre-treatment compared with non-responders. Pre-treatment tumors from responders also exhibited higher densities of effector memory cytotoxic T cells and regulatory T cells compared with non-responders. In addition, higher density of cytotoxic tumor-infiltrating T cells at baseline correlated with a better progression-free survival (PFS). Conclusions: We show that quantitative assessments of CD8+ CD3+ PD-1+ T cells, percentage of TAMs expressing PD-L1, and other T-cell densities correlate with sarcoma response to pembrolizumab and improved PFS. Our findings support that multiple cell types present at the start of treatment may enhance tumor regression following anti–PD-1 therapy in specific advanced sarcomas. Efforts to confirm the activity of pembrolizumab in an expansion cohort of patients with UPS/DDLPS are underway.