Citations

Clear

215 citation(s) found for "Santo, C".

1274 Identification and characterization of immune checkpoint inhibitor induced immune-related adverse events from electronic health records using natural language processing techniques
Barman, Hannah , Venkateswaran, Sriram, Santo, Antonio , Raghunatha, Bharathwaj, Yoo, Unice, Kottschade, Lisa A. , Block, Matthew S. , Chandler, G. Scott , Wagner, Tyler , Mohindra, Rajat, Venkateswaran, Sriram, Santo, Antonio Del, Rao, Krishna , Wagner, Tyler, Mohindra, Rajat

Mayo Clinic

Regular and Young Investigator Award Abstracts | November 7, 2022 | Volume: No volume available | Issue: No issue available | Pages: A1322-A1322

10.1136/jitc-2022-sitc2022.1274 Get It

Pneumatization of the Sphenoidal Sinus May Affect Endonasal Cranial Base Reconstruction
Ramos, Henrique Faria , Possatti, Lucas Loss, Pinheiro-Neto, Carlos Diogenes, Pinheiro‐Neto, Carlos

Mayo Clinic

Journal of Craniofacial Surgery | October 31, 2022 | Volume: 33 | Issue: 8 | Pages: e808-e810

10.1097/scs.0000000000008690 | PMID 36409852 Get It

Objective: The aim of this study is to verify if the length of the nasoseptal flap is sufficient to cover the tuberculum sellae and planum sphenoidale of sphenoidal sinuses with varied degrees of pneumatization Methods: Retrospective study of paranasal sinus computed tomography comparing the potential length of the nasoseptal flap and the length of the nasoseptal flap required for reconstruction of transtuberculum and transplanum approaches in conchal, presellar, sellar, incomplete postsellar, and complete postsellar sphenoidal sinuses Results: The length of the nasoseptal flap required for reconstruction of transtuberculum and transplanum approaches was directly related to the degree of pneumatization of the sphenoidal sinus. The nasoseptal flap length was adequate to cover the cranial base after transtuberculum approaches of all cases from the conchal, presellar, and sellar groups and the majority of cases from postsellar pneumatization. For transplanum approaches, the nasosseptal flap was sufficient to reconstruct defects in most cases from conchal, pre-sellar, and sellar type sinuses and in 54,9% and 19,2% in incomplete and complete postsellar, respectively. Conclusions: In well pneumatized sphenoidal sinus, the nasoseptal flap may not be sufficient to cover the cranial base after transtuberculum and transplanum approaches.
Adjunctive Dexmedetomidine in Alcohol Withdrawal Syndrome: A Systematic Review and Meta-analysis of Retrospective Cohort Studies and Randomized Controlled Trials
Polintan, Edgar Theodore , Danganan, Lester Mico Lopez , Cruz, Nikki , Macapagal, Sharina , Catahay, Jesus Alfonso , Patarroyo‐Aponte, Gabriel , Lo, Kevin Bryan , Polintan, Edgar Theodore T , Macapagal, Sharina C, Azmaiparashvili, Zurab

Mayo Clinic

Annals of Pharmacotherapy | October 19, 2022 | Volume: 57 | Issue: 6 | Pages: 696-705

10.1177/10600280221130458 | PMID 36258676 Get It

Objective: To investigate whether dexmedetomidine (DEX), as adjunctive therapy to benzodiazepine (BZD), is superior to BZD alone in critically ill patients with alcohol withdrawal syndrome (AWS). Data Sources: PubMed Central, Cochrane CENTRAL, ClinicalTrials.gov and Google Scholar were used as search databases. Specific keywords and MeSH terms were “dexmedetomidine,” “benzodiazepine,” and “alcohol withdrawal syndrome.” The last search was on September 16, 2022. Study Selection and Data Extraction: Randomized controlled trials (RCTs) and nonrandomized/cohort studies exploring the use of DEX in the management of AWS were included. A total of 12 studies were included in the systematic review and 7 in the meta-analysis. Data Synthesis: The intensive care unit length of stay (ICU LOS) was found to have a mean difference (MD) of 48.06 [37.48, 58.64], P = <0.001 for the cohort subgroup, significantly favoring the DEX arm, but, in contrast, pooled RCT data showed a result of –20.07 [–36.86, –3.28], P = 0.02, a shorter ICU LOS for the DEX arm. Bradycardia and hypotension incidence significantly favored the BZD arm in both subgroups. This study compares the effectiveness of adjunctive DEX in clinical practice and aims to help providers in critical decision-making by compiling and analyzing the best current available evidence of its use in AWS. Conclusions: Based on low to very low level of evidence, adjunctive DEX showed no significant difference for ICU LOS when compared with BZD alone. Pooled randomized trials potentially show a benefit but are similarly limited by their low quality of evidence.
The Dense Breast Clinic: Initial Experience of a Patient-Centered Breast Imaging Clinic
Robinson, Kristin A. , Staack, Sasha O., Patel, Bhavika , Lorans, Roxanne, Maimone, Santo , Pizzitola, Victor J. , Patel, Bhavika K , Sharpe, Richard E. , Maimone, Santo , Kling, Juliana M.

Mayo Clinic

Journal of Breast Imaging | October 3, 2022 | Volume: 4 | Issue: 6 | Pages: 582-589

10.1093/jbi/wbac063 | PMID 38416998 Get It

Abstract Objective Establish a radiologist-run consultation clinic to review breast density and supplemental screening exams (SSEs) directly with patients in response to breast density reporting laws. Methods Breast radiologists opened and staffed a clinic for formal patient consultations regarding breast density and SSEs. An IRB-approved questionnaire assessed patient knowledge of breast density, SSEs, and encounter satisfaction. Comparative statistical analyses were performed on knowledge-based questions. Results From February 2019 to February 2021, 294 reimbursable consultations were performed with 215 patients completing pre- and post-consultation questionnaires (survey response rate, 73%). Median patient age was 58 years (range, 34–86 years) and 9% (19/210) had a personal history of breast cancer. An increase in patient knowledge of breast density and SSEs was observed as follows: breast density categories (9% correct pre-consultation (20/215), 86% correct post-consultation (185/215), P &lt; 0.001), dense breast effects on cancer risk (39% correct pre-consultation (83/215), 84% post-consultation (180/215)), mammogram sensitivity (90% correct pre-consultation (193/215), 94% post-consultation (201/215)), and increased cancer detection with SSEs (82% correct pre-consultation (177/215), 95% post-consultation (205/215)) (P &lt; 0.001). Post-consultation, 96% (200/209) were satisfied with the usefulness of information, 89% (186/209) strongly agreed they had sufficient knowledge of SSEs, and 81% (167/205) agreed they would like future opportunities to meet with a breast radiologist. Conclusion A consultation clinic staffed by breast radiologists focused on breast density and supplemental breast cancer screening can provide personalized patient counseling, engage patients in shared decision making, assist referring clinicians, and support high quality patient-centered care.
Impact of atrial fibrillation on the risk of major adverse cardiac events following coronary revascularisation
Jung, Richard G. , Abdel‐Razek, Omar , Santo, Pietro Di , Gillmore, Taylor , Stotts, Cameron , Makwana, Dwipen, Soriano, Joelle , Moreland, Robert B. , Verreault‐Julien, Louis , Goh, Cheng Yee , Parlow, Simon , Sypkes, Caleb, Ramirez, Daniel F, Sadek, Mouhannad, Toeg, Hadi , Froeschl, Michael , Labinaz, Marino , Hibbert, Benjamin , Simard, Trevor , Hibbert, Benjamin , Abdel-Razek, Omar , Moreland, Robert, Ramirez, Daniel F., Sadek, Mouhannad M. , Chan, Vincent , Simard, Trevor

Mayo Clinic

Open Heart | September 23, 2022 | Volume: 9 | Issue: 2 | Pages: e002012

10.1136/openhrt-2022-002012 | PMID 36150746 Get It

Objective Atrial fibrillation (AF) remains a highly prevalent arrhythmia with significant burden on morbidity and mortality. The impact of AF in the revascularised population remains incompletely described. Given the high prevalence of AF in the revascularised population, we sought to evaluate the incidence and prognosis in patients with pre-existing and new-onset AF following revascularisation. Methods We used the University of Ottawa Heart Institute Revascularisation Registry to identify patients who underwent revascularisation between August 2015 and March 2020, who were prospectively followed for an average of one year. We conducted a retrospective cohort study analysing the association between AF and clinical outcomes. The primary outcome of interest was 1-year major adverse cardiac events (MACE) defined as a composite of death, myocardial infarction, unplanned revascularisation and cerebrovascular accidents. Moreover, secondary outcomes include the individual components of MACE and bleeding. Results A total of 6704 patients underwent revascularisation and completed 1-year clinical follow-up. Median time to follow-up was 12.8 (IQR 11.2–15.9) months. One-year MACE occurred in 166 (21.8%) and 683 (11.5%) patients in AF and non-AF groups, respectively (adjusted HR, 1.61; 95% CI 1.29 to 2.01; p<0.0001). AF was independently predictive of 1-year mortality, myocardial infarction, unplanned revascularisation, cerebrovascular accident and bleeding. Within 1 year, 299 (4.5%) episodes of new-onset AF was observed. New-onset AF following revascularisation was also associated with 1-year MACE, mortality, myocardial infarction, cerebrovascular accident and unplanned revascularisation. Conclusions Preprocedural and new-onset AF following revascularisation remains highly predictive 1-year MACE. AF should be considered in addition to traditional risk factors for adverse outcomes following revascularisation.
Abbreviated Molecular Breast Imaging: Feasibility and Future Considerations
Maimone, Santo , Morozov, Andrey P, Letter, Haley , Robinson, Kristin A. , Wasserman, Martha, Li, Zhuo , Maxwell, Robert W. , Letter, Haley P, Wasserman, Martha C, Maimone, Santo

Mayo Clinic

Journal of Breast Imaging | September 15, 2022 | Volume: 4 | Issue: 6 | Pages: 590-599

10.1093/jbi/wbac060 | PMID 38416994 Get It

Abstract Objective Molecular breast imaging (MBI) is a supplemental screening modality consistently demonstrating incremental cancer detection over mammography alone; however, its lengthy duration may limit widespread utilization. The study purpose was to assess feasibility of an abbreviated MBI protocol, providing readers with mediolateral oblique (MLO) projections only and assessing performance in lesion detection and localization. Methods Retrospective IRB-exempt blinded reader study administered to 5 fellowship-trained breast imaging radiologists. Independent reads performed for 124 screening MBI cases, half abnormal and half negative/normal. Readers determined whether an abnormality was present, side of abnormality, and location of abnormality (medial/lateral). Abnormal cases had confirmatory biopsy or surgical pathology; normal cases had imaging follow-up ensuring true negative results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess performance. A false negative result indicated that a reader failed to detect abnormal uptake; a false positive result indicated a reader incorrectly called an abnormality for a negative case. Tests for association included chi-square, Fisher-exact, and analysis of variance. Results Mean reader performance for detecting abnormal uptake: sensitivity 96.8%, specificity 98.7%, PPV 98.8%, and NPV 96.9%. Accuracy in localizing lesions to the medial or lateral breast was 100%. There were no associations in reader performance with reader experience, reader technique, lesion morphology, or lesion pathology. Median lesion size was 1.0 cm (range: 0.4–8.0 cm). All readers correctly identified 97.7% (42/43) of lesions with malignant or elevated risk pathology. Conclusion An abbreviated MBI protocol (MLO images only) maintained high accuracy in lesion detection and localization.
Clinical applications of heart rhythm monitoring tools in symptomatic patients and for screening in high-risk groups
Carrington, M , Chahal, C. Anwar A. , Epstein, Andrew E. , Gallina, Sabina , Fedorowski, Artur , Sutton, Richard , Khanji, Mohammed Y , Carrington, Mafalda , Fedorowski, Artur , Sutton, Richard , Khanji, Mohammed Yunus , Chahal, Choudhary Anwar A , Providência, Rui , Ricci, Fabrizio

Mayo Clinic

EP Europace | August 19, 2022 | Volume: 24 | Issue: 11 | Pages: 1721-1729

10.1093/europace/euac088 | PMID 35983729 Get It

Abstract Recent technological advances have facilitated and diversified the options available for the diagnosis of cardiac arrhythmias. Ranging from simple resting or exercise electrocardiograms to more sophisticated and expensive smartphones and implantable cardiac monitors. These tests and devices may be used for varying periods of time depending on symptom frequency. The choice of the most appropriate heart rhythm test should be guided by clinical evaluation and optimized following accurate characterization of underlying symptoms, ‘red flags’, risk factors, and consideration of cost-effectiveness of the different tests. This review provides evidence-based guidance for assessing suspected arrhythmia in patients who present with symptoms or in the context of screening, such as atrial fibrillation or advanced conduction disturbances following transcatheter aortic valve implantation in high-risk groups. This is intended to help clinicians choose the most appropriate diagnostic tool to facilitate the management of patients with suspected arrhythmias.
Long coronavirus disease-related persistent poor sleep quality and progression of enlarged perivascular spaces. A longitudinal study
Brutto, Óscar H. Del , Mera, Robertino M. , Costa, Aldo F. , Castillo, Pablo R. , Del Brutto, Oscar H , Castillo, Pablo R , Rumbea, Denisse A. , Recalde, Bettsy Y.

Mayo Clinic

Sleep | July 25, 2022 | Volume: 45 | Issue: 9 | Pages: No page available

10.1093/sleep/zsac168 | PMID 35878737 Get It

Transcatheter edge-to-edge repair in patients with mitral regurgitation and cardiogenic shock: a new therapeutic target
Jung, Richard G. , Santo, Pietro Di , Hibbert, Benjamin , Hibbert, Benjamin , Simard, Trevor

Mayo Clinic

Current Opinion in Critical Care | July 20, 2022 | Volume: 28 | Issue: 4 | Pages: 426-433

10.1097/mcc.0000000000000952 | PMID 35856980 Get It

Purpose of review Cardiogenic shock with significant mitral regurgitation portends a poor prognosis with limited therapeutic options. Herein, we review the available evidence regarding the patient characteristics, management, impact of transcatheter edge-to-edge repair (TEER) on hemodynamics, and clinical outcomes of patients with cardiogenic shock and mitral regurgitation. Recent findings Several observational studies and systematic reviews have demonstrated the feasibility and safety of TEER in cardiogenic shock complicated by degenerative or functional mitral regurgitation. Surgical interventions for mitral regurgitation remain limited owing to the risk profile of patients in cardiogenic shock. TEER has been studied in both degenerative and functional mitral regurgitation and remains feasible in the critically ill population. Moreover, TEER is associated with reduction in mitral regurgitation and improvement in-hospital and long-term mortality. Summary TEER remains a promising therapeutic option in cardiogenic shock complicated by significant mitral regurgitation, but additional research is required to identify patient and procedural characteristics, hemodynamic parameters, and the optimal time for intervention. Moreover, future randomized controlled trials are in progress to evaluate the potential benefit of TEER against medical management in cardiogenic shock and mitral regurgitation.
Dynamic, Tunable, and Conformal Wearable Compression Using Active Textiles
Granberry, Rachael , Clarke, Megan , Pettys‐Baker, Robert, Woelfle, Heidi , Compton, Crystal , Ross, Amy, Johnson, Kirstyn M., Padula, Santo, Shah, Surbhi , Abel, Julianna , Holschuh, Brad

Mayo Clinic

Advanced Materials Technologies | June 29, 2022 | Volume: 7 | Issue: 12 | Pages: No page available

10.1002/admt.202200467 Get It

AbstractNew medical compression technologies that are simultaneously low‐profile, facile to don, and dynamic—applying medical compression only when needed—can expand the use of wearable compression, increase patient compliance, and lead to better medical outcomes. Dynamic and conformal wearable compression devices are presented that can be donned in a low‐stiffness state and transition into a high‐stiffness and, consequently, high‐compression state, on‐demand. These devices are enabled by active textiles developed from custom NiTi filaments that remain inactive at room temperature and accomplish actuation proximal to the human body surface. Further, these compression devices exploit NiTi material hysteresis to sustain a high‐compression state post‐heating and upon equilibrium with the body surface temperature for thermally‐comfortable, on‐body performance. Two case study examples—1) a consumer medical compression device and 2) a custom astronaut compression device—demonstrate the generalizability and flexibility of the engineering and design methods to develop a range of dynamic, tunable, and conformal compression devices with different goals and requirements. Further, this work demonstrates a roadmap for developing wearable systems that can accommodate a range of users without sacrificing system performance. This research opens doors for new NiTi‐based medical and consumer applications that interface with the body surface.