Citations

Clear

4579 citation(s) found for "Xu, Steven".

Prophylactic lymphaticovenous anastomosis (LVA) for preventing lymphedema after sarcoma resection in the lower limb: A report of three cases and literature review
Wan, Rou , Kuruoglu, Doga , Houdek, Matthew T. , Moran, Steven L. , Kuruoglu, Doga , Houdek, Matthew T , Moran, Steven L , Hussain, Arif

Mayo Clinic

Microsurgery | October 13, 2022 | Volume: 43 | Issue: 3 | Pages: 273-280

10.1002/micr.30975 | PMID 36226524 Get It

AbstractPatients with soft tissue tumors of the lower extremities are at greater risk to develop postoperative disruption of lymphatic vessels. Currently, there is no widely effective cure for lymphatic dysfunction. Therefore, the best strategy is to prevent it and reconstruct efficient drainage as soon as the original pathway is damaged. We present a report of three prophylactic LVA cases after sarcoma resection in the lower limb, and a literature review to show the feasibility of prophylactic LVAs. The patients were 35, 73, and 77 years old, respectively, at the time of the procedure. All three patients had sarcoma in the medial thigh and underwent radiation therapy before the surgery. The locations of the LVAs include the medial thigh and medial and lateral calf. During the surgery, methylene blue and/or indocyanine green were injected to identify lymphatic vessels. Postoperative recovery was uneventful immediately after the surgery. At follow‐up visits, all three patients reported improved functions with no significant swelling in the lower limb. One patient experienced a surgical wound infection that resolved after antibiotic admission. Two patients had a history of cardiac diseases, a major risk factor for developing postoperative lymphedema, but these two patients did not develop lymphedema with the treatment of prophylactic LVAs. These results suggest that prophylactic LVA may be an effective strategy to prevent secondary lymphedema after sarcoma resection. Further investigation is warranted.
Genetic Variant in Nicotinic Receptor α4-Subunit Causes Sleep-Related Hyperkinetic Epilepsy via Increased Channel Opening
Mazzaferro, Simone , Msekela, Deborah J., Cooper, Edward C. , Maheshwari, Atul , Sine, Steven M.

Mayo Clinic

International Journal of Molecular Sciences | October 12, 2022 | Volume: 23 | Issue: 20 | Pages: 12124

10.3390/ijms232012124 | PMID 36292983 Get It

We describe genetic and molecular-level functional alterations in the α4β2 neuronal nicotinic acetylcholine receptor (nAChR) from a patient with sleep-related hyperkinetic epilepsy and a family history of epilepsy. Genetic sequencing revealed a heterozygous variant c.851C>G in the CHRNA4 gene encoding the α4 subunit, resulting in the missense mutation p.Ser284Trp. Patch clamp recordings from genetically engineered nAChRs incorporating the α4-Ser284Trp subunit revealed aberrant channel openings in the absence of agonist and markedly prolonged openings in its presence. Measurements of single channel current amplitude distinguished two pentameric stoichiometries of the variant nAChR containing either two or three copies of the α4-Ser284Trp subunit, each exhibiting aberrant spontaneous and prolonged agonist-elicited channel openings. The α4-Ser284 residue is highly conserved and located within the M2 transmembrane α-helix that lines the ion channel. When mapped onto the receptor’s three-dimensional structure, the larger Trp substitution sterically clashes with the M2 α-helix from the neighboring subunit, promoting expansion of the pore and stabilizing the open relative to the closed conformation of the channel. Together, the clinical, genetic, functional, and structural observations demonstrate that α4-Ser284Trp enhances channel opening, predicting increased membrane excitability and a pathogenic seizure phenotype.
Technical note: Investigation of dose and LETd effect to rectum and bladder by using non‐straight laterals in prostate cancer receiving proton therapy
Yang, Yunze, Rwigema, Jean‐Claude M. , Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Wong, William W. , Shen, Jiajian , Schild, Steven E. , Shen, Jiajian , Bues, Martin , Liu, Wei

Mayo Clinic

Medical Physics | October 8, 2022 | Volume: 49 | Issue: 12 | Pages: 7428-7437

10.1002/mp.16008 | PMID 36208196 Get It

AbstractBackgroundParallel‐opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated.PurposeTo investigate the dose and dose averaged LET (LETd) impact of using new beam arrangements rotating beams 5°–15° posteriorly to the laterals in prostate cancer treated with pencil‐beam‐scanning (PBS) proton therapy.MethodsTwenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel‐opposed lateral beams. Dose‐volume histograms (DVHs) from posterior oblique beams were analyzed. Dose‐LETd‐volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two‐sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed‐rank test.ResultsRotating beam angles from laterals to slightly posterior by 5°–15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01).ConclusionsPosterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.
The First Survival Score for Patients Aged ≥80 Years Irradiated for Brain Metastases
Rades, Dirk , DELIKANLI, CANSU, Schild, Steven E. , Kristiansen, Charlotte , Tvilsted, Søren, Kristiansen, Charlotte , Schild, Steven , DELIKANLI, CANSU, Janssen, Stefan

Mayo Clinic

Biology | October 8, 2022 | Volume: 11 | Issue: 10 | Pages: 1434

10.3390/biology11101434 | PMID 36290338 Get It

Survival scores facilitate personalized cancer treatment. Due to demographic changes, very elderly patients are more prevalent than in the past. A score was developed in 94 patients aged ≥ 80 years undergoing whole-brain radiotherapy for brain metastases. Dose fractionation, treatment period, age, sex, performance score (ECOG-PS), tumor type, count of lesions, metastases outside the brain, and interval tumor diagnosis to radiotherapy were retrospectively evaluated. Independent predictors of survival were used for the score. Based on individual scoring points obtained from 3-month survival rates, prognostic groups were designed. Additionally, the score was compared to an existing tool developed in patients ≥ 65 years. ECOG-PS, count of lesions, and extra-cranial metastases were independent prognostic factors. Three groups were created (7, 10, and 13–16 points) with 3-month survival of 6%, 25%, and 67% (p < 0.001), respectively. Positive predictive values (PPVs) regarding death ≤ 3 and survival ≥ 3 months were 94% and 67% (new score) vs. 96% and 48% (existing tool), respectively. PPVs for survival ≥1 and ≥2 months were 88% and 79% vs. 63% and 58%, respectively. Both tools were accurate in predicting death ≤2, ≤3, and ≤6 months. The new score was more precise regarding death ≤1 month and survival (all time periods) and appeared preferable. However, it still needs to be validated.
Practice Patterns in Operative Flexor Tendon Laceration Repair: A 15-Year Analysis of Continuous Certification Data from the American Board of Plastic Surgery
Weissman, Joshua P. , Chappell, Ava G. , Moran, Steven L. , Gosain, Arun K. , Sasson, Daniel Cyrus

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | October 7, 2022 | Volume: 10 | Issue: 10 | Pages: e4558

10.1097/gox.0000000000004558 | PMID 36225846 Get It

Background: The American Board of Plastic Surgery has been collecting practice data on operative repair of flexor tendon lacerations since 2006, as part of its Continuous Certification program. Methods: Data on operative repair of flexor tendon lacerations from 2006 to 2014 were reviewed and compared with those from 2015 to 2020. National practice trends observed in these data were evaluated and reviewed alongside published literature and evidence-based medicine. Results: In total, 780 patients with flexor tendon laceration injuries were included. Mean patient age was 38 years; mean time between tendon injury and first evaluation was 4 days, and the mean time from injury to operative repair was 12 days. Four-strand sutures remain the most common technique of tendon repair (57%). In the recent cohort, there were significant decreases in tourniquet use (94% versus 89%), general anesthesia (88% versus 74%), and monofilament sutures (44% versus 35%), with a significant increase reported in preserving the A1 pulley (20% versus 29%). Postoperative movement was described as “almost full range of motion” or “good” in 70% of cases, and 74% of patients were satisfied with their results. Postoperative adverse events were reported in 26% of cases, with the most common complications being tendon adhesions (14%) and rupture (3%). Conclusions: Review of The American Board of Plastic Surgery tracer data for operative repair of flexor tendon lacerations establishes a framework by which surgeons can evaluate how their current practice aligns with that of their peers, and whether their practice patterns remain current relative to recommendations from evidence-based medicine.
Three-Year Interval for the Multi-Target Stool DNA Test for Colorectal Cancer Screening: A Longitudinal Study
Imperiale, Thomas F. , Lavin, Philip T. , Marti, Tara N. , Jakubowski, Debbie , Itzkowitz, Steven H. , May, Folasade P. , Limburg, Paul J. , Sweetser, Seth , Daghestani, Anas , Berger, Barry M. , Limburg, Paul J

Mayo Clinic

Cancer Prevention Research | October 7, 2022 | Volume: 16 | Issue: 2 | Pages: 89-97

10.1158/1940-6207.capr-22-0238 | PMID 36205504 Get It

Abstract Data supporting the clinical utility of multi-target stool DNA (mt-sDNA) at the guideline-recommended 3-year interval have not been reported. Between April 2015 and July 2016, candidates for colorectal cancer screening whose providers prescribed the mt-sDNA test were enrolled. Participants with a positive baseline test were recommended for colonoscopy and completed the study. Those with a negative baseline test were followed annually for 3 years. In year 3, the mt-sDNA test was repeated and colonoscopy was recommended independent of results. Data were analyzed using the Predictive Summary Index (PSI), a measure of the gain in certainty for dichotomous diagnostic tests (where a positive value indicates a net gain), and by comparing observed versus expected colorectal cancers and advanced precancerous lesions. Of 2,404 enrolled subjects, 2,044 (85%) had a valid baseline mt-sDNA result [284 (13.9%) positive and 1,760 (86.1%) negative]. Following participant attrition, the year 3 intention to screen cohort included 591 of 1,760 (33.6%) subjects with valid mt-sDNA and colonoscopy results, with no colorectal cancers and 63 advanced precancerous lesions [22 (34.9%) detected by mt-sDNA] and respective PSI values of 0% (P = 1) and 9.3% (P = 0.01). The observed 3-year colorectal cancer yield was lower than expected (one-sided P = 0.09), while that for advanced precancerous lesions was higher than expected (two-sided P = 0.009). Repeat mt-sDNA screening at a 3-year interval resulted in a statistically significant gain in detection of advanced precancerous lesions. Due to absence of year 3 colorectal cancers, the PSI estimate for colorectal cancer was underpowered and could not be reliably quantified. Larger studies are required to assess the colorectal cancer study findings. Prevention Relevance: Understanding the 3-year yield of mt-sDNA for colorectal cancer and advanced precancerous polyps is required to ensure the clinical appropriateness of the 3-year interval and to optimize mt-sDNA's screening effectiveness.
A Prospective Study of Lumbar Facet Arthroplasty in the Treatment of Degenerative Spondylolisthesis and Stenosis
Freedman, Brett A. , Sebastian, Arjun S. , Coric, Domagoj , Welch, William C. , Steinmetz, Michael P. , Robbins, Stephen E. , Ament, Jared D. , Anand, Neel , Baron, Eli M. , Whitmore, Robert G. , Whiting, Donald, Tahernia, David, Chahlavi, Ali, Chi, John, Pirris, Stephen M. , Groff, Michael W. , Fabi, Alain Y., Meyer, Scott A., Kushwaha, Vivek, Kent, Roland , DeLuca, Steven, Smorgick, Yossi , Anekstein, Yoram , Group, TOPS Study, Pinter, Zachariah W. , Nassr, Ahmad , Arnold, Paul M. , Huang, Jason Haitao , Sandhu, Faheem A. , Cheng, Joseph S. , Group, TOPS Study

Mayo Clinic

Clinical Spine Surgery | October 3, 2022 | Volume: 36 | Issue: 2 | Pages: E59-E69

10.1097/bsd.0000000000001365 | PMID 36191093 Get It

Study Design: Prospective randomized Food and Drug Administration investigational device exemption clinical trial. Objective: The purpose of the present study is to report the 1-year clinical and radiographic outcomes and safety profile of patients who underwent lumbar facet arthroplasty through implantation of the Total Posterior Spine System (TOPS) device. Summary of Background Data: Lumbar facet arthroplasty is one proposed method of dynamic stabilization to treat grade-1 spondylolisthesis with stenosis; however, there are currently no Food and Drug Administration-approved devices for facet arthroplasty. Methods: Standard demographic information was collected for each patient. Radiographic parameters and patient-reported outcome measures were assessed preoperatively and at regular postoperative intervals. Complication and reoperation data were also collected for each patient. Results: At the time of this study, 153 patients had undergone implantation of the TOPS device. The mean surgical time was 187.8 minutes and the mean estimated blood loss was 205.7cc. The mean length of hospital stay was 3.0 days. Mean Oswestry Disability Index, Visual Analog Score leg and back, and Zurich Claudication Questionnaire scores improved significantly at all postoperative time points (P>0.001). There were no clinically significant changes in radiographic parameters, and all operative segments remained mobile at 1-year follow-up. Postoperative complications occurred in 11 patients out of the 153 patients (7.2%) who underwent implantation of the TOPS device. Nine patients (5.9%) underwent a total of 13 reoperations, 1 (0.6%) of which was for device-related failure owing to bilateral L5 pedicle screw loosening. Conclusions: Lumbar facet arthroplasty with the TOPS device demonstrated a statistically significant improvement in all patient-reported outcome measures and the ability to maintain motion at the index level while limiting sagittal translation with a low complication rate.
Restoration of hamstring function following sciatic nerve resection at the greater sciatic foramen with reconstruction involving acellular nerve allograft and vascularized sural nerve autograft: A case report
Sarcon, Aida K. , Li, Neill Y. , Houdek, Matthew T. , Moran, Steven L. , Houdek, Matthew T

Mayo Clinic

Microsurgery | September 30, 2022 | Volume: 42 | Issue: 8 | Pages: 824-828

10.1002/micr.30970 | PMID 36177748 Get It

AbstractSegmental loss of the sciatic nerve secondary to oncologic resection or trauma is detrimental to hamstring and leg function. The diameter of this nerve and the length of its axons spanning the lower extremity create significant challenges in reconstruction and optimizing return of sensory or motor function. The purpose of this report is to describe outcomes of a free vascularized sural nerve graft to preserve hamstring function in a large proximal sciatic nerve defect beginning at the greater sciatic foramen. A 44‐year‐old female underwent neoadjuvant chemotherapy and radiation for treatment of a left sciatic nerve synovial cell sarcoma. The patient underwent R0 resection of the proximal left sciatic nerve resulting in a 15 cm defect. An ipsilateral vascularized sural nerve graft was used to reconstruct the medial aspect of the sciatic nerve, prioritizing the tibial division, in an effort to restore hamstring function and plantar sensation. A 5 cm allograft nerve was added to the cutaneous branches of the sural nerve graft to better span the large defect and reconstruct the lateral aspect of the nerve. The patient's postoperative course was uneventful. At 1‐year follow‐up, the patient showed MRC grade 4/5 strength with knee flexion and steady gait pattern with a left ankle‐foot orthosis. Outcomes support the use of a single vascularized nerve graft alongside acellular nerve allograft to restore motor function in large diameter and large defect mixed nerve injuries.