Citations

Clear

122 citation(s) found for "Murray, David".

Clonotypic Light Chain Peptides Identified for Monitoring Minimal Residual Disease in Multiple Myeloma without Bone Marrow Aspiration
Bergen, H. Robert, Dasari, Surendra , Dispenzieri, Angela , Mills, John R. , Ramı́rez-Alvarado, Marina , Tschumper, Renee C. , Jelinek, Diane F., Barnidge, David R. , Murray, David , Dispenzieri, Angela , Ramirez-Alvarado, Marina

Mayo Clinic

Clinical Chemistry | October 1, 2015 | Volume: 62 | Issue: 1 | Pages: 243-251

10.1373/clinchem.2015.242651 | PMID 26430073 Get It

Abstract BACKGROUND Analytically sensitive techniques for measuring minimal residual disease (MRD) in multiple myeloma (MM) currently require invasive and costly bone marrow aspiration. These methods include immunohistochemistry (IHC), flow cytometry, quantitative PCR, and next-generation sequencing. An ideal MM MRD test would be a serum-based test sensitive enough to detect low concentrations of Ig secreted from multifocal lesions. METHODS Patient serum with abundant M-protein before treatment was separated on a 1-dimensional SDS-PAGE gel, and the Ig light-chain (LC) band was excised, trypsin digested, and analyzed on a Q Exactive mass spectrometer by LC-MS/MS. We used the peptide's abundance and sequence to identify tryptic peptides that mapped to complementary determining regions of Ig LCs. The clonotypic target tryptic peptides were used to monitor MRD in subsequent serum samples with prior affinity enrichment. RESULTS Sixty-two patients were tested, 20 with no detectable disease by IHC and 42 with no detectable disease by 6-color flow cytometry. A target peptide that could be monitored was identified in 57 patients (91%). Of these 57, detectable disease by LC-MS/MS was found in 52 (91%). CONCLUSIONS The ability to use LC-MS/MS to measure disease in patients who are negative by bone marrow–based methodologies indicates that a serum-based approach has more analytical sensitivity and may be useful for measuring deeper responses to MM treatment. The method requires no bone marrow aspiration.
Using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry to detect monoclonal immunoglobulin light chains in serum and urine
Barnidge, David R. , Krick, Thomas P., Griffin, Timothy J. , Murray, David , Murray, David L., Griffin, Timothy J

Mayo Clinic

Rapid Communications in Mass Spectrometry | October 1, 2015 | Volume: 29 | Issue: 21 | Pages: 2057-2060

10.1002/rcm.7314 | PMID 26443406 Get It

Rationale Use of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) to monitor serum and urine samples for endogenous monoclonal immunoglobulins. MALDI‐TOFMS is faster, fully automatable, and provides superior specificity compared to protein gel electrophoresis (PEL). Methods Samples were enriched for immunoglobulins in 5 min using Melon Gel™ followed by reduction with dithiothreitol for 15 min to separate immunoglobulin light chains and heavy chains. Samples were then desalted using C4 ZipTips, mixed with sinapinic acid matrix, and analyzed on a Bruker Biflex III MALDI‐TOF mass spectrometer. Results Monoclonal immunoglobulin light chains were identified in serum and urine samples from patients with a known monoclonal gammopathy using MALDI‐TOFMS with minimal sample preparation. Conclusions MALDI‐TOFMS can identify a monoclonal immunoglobulin in serum and urine samples. The molecular mass of the monoclonal immunoglobulin light chain is obtained providing unprecedented specificity compared to PEL. In addition, the methodology can be automated, making it a practical alternative to PEL. Copyright © 2015 John Wiley & Sons, Ltd.
Abstract 5093: Pre-clinical assessment of a novel anti-invasion nanoparticle therapeutic in combination with bevacizumab for the treatment of glioblastoma
Murray, David W. , MacCarthy, Brian , Symons, Marc , Murray, David W., O’Halloran, Philip J. , Jarzabek, Monika A. , Sarkaria, Jann N. , Schiffelers, Raymond Michel , Byrne, Annette T.

Mayo Clinic

Cancer Research | August 5, 2015 | Volume: 75 | Issue: 15_Supplement | Pages: 5093-5093

10.1158/1538-7445.am2015-5093 Get It

Abstract Glioblastoma (GBM), a highly invasive primary brain tumour, remains an incurable disease (1). Angiogenesis, the formation of new blood vessels, is a defining feature of GBM (2). Targeting GBM angiogenesis with Bevacizumab (Bev) is associated with improved progression free survival, but may also significantly enhance local tumour invasion (3). RhoGTPases and their activators, guanine nucleotide exchange factors (GEFs), play central roles in the invasive process (4). Herein, we sought to identify and target GEFs of importance in meditating GBM invasion with a view to improving Bev response. We report a novel strategy by which GBM tumours invade and proliferate via overexpression of the GEF beta-PIX which was shown to be increased at the invasive edge in 74% of GBM tumours assessed (n = 19) compared with tumour core (5). We have further shown that siRNA-mediated knockdown of beta-PIX in GBM patient-derived xenograft cell cultures and cell lines resulted in decreased cell invasion in 3D, cell proliferation and survival assays in vitro. Furthermore, we have uncovered a role for beta-PIX expression in endothelial cell function, as knockdown of beta-PIX inhibits HUVEC cell migration in vitro. To interrogate in vivo effects, we established an imagable orthotopic model of invasive GBM in mice, by stereotactically implanting GBM cells stably overexpressing firefly luciferase (U87R-GFP-luc2). beta-PIX-(human and mouse) specific siRNA or scrambled control siRNA (2 × 10 μg i.c.) were delivered to tumours using an alphaVbeta3 integrin targeting-(RGD peptide conjugated)-nanoparticle (InVivoPlex Aparna Bio Corp, Rockville, MD). Animals were treated with- or without- Bev (6 × 10mg/kg i.p. over 12 days). Initial data has shown that animals treated with beta-PIX siRNA nanoparticles in combination with Bev had an improved median survival of 100 days compared with Bev- alone treated mice (median: 88 days). Our data may support the future clinical use of a beta-PIX-targeting nanoparticle therapeutic, to improve Bev outcomes in GBM. 1. Kohler BA et al J Natl Cancer Inst. 2011; 103, 714-736 2. Jain RK et al Nat Rev Neurosci. 2007; 8(8):610-22 3. Norden AD et al Neurology 2008; 70: 779-787 4. Murray D et al Brit J Can 2014; 110(5):1307-15 5. Hoelzinger DB et al Neoplasia 2005; 7(1): 7-16 Citation Format: David W. Murray, Philip O'Halloran, Monika Jarzabek, Brian MacCarthy, Jann N. Sarkaria, Raymond M. Schiffelers, Marc Symons, Annette T. Byrne. Pre-clinical assessment of a novel anti-invasion nanoparticle therapeutic in combination with bevacizumab for the treatment of glioblastoma. [abstract]. In: Proceedings of the 106th Annual Meeting of the American Association for Cancer Research; 2015 Apr 18-22; Philadelphia, PA. Philadelphia (PA): AACR; Cancer Res 2015;75(15 Suppl):Abstract nr 5093. doi:10.1158/1538-7445.AM2015-5093
Monitoring IgA Multiple Myeloma: Immunoglobulin Heavy/Light Chain Assays
Katzmann, Jerry A., Kohlhagen, Mindy , Kyle, Robert A. , Murray, David , Snyder, Melissa R, Dispenzieri, Angela , Willrich, Maria Alice V. , Snyder, Melissa R, Rajkumar, S. Vincent , Dispenzieri, Angela

Mayo Clinic

Clinical Chemistry | December 2, 2014 | Volume: 61 | Issue: 2 | Pages: 360-367

10.1373/clinchem.2014.231985 | PMID 25451866 Get It

AbstractBACKGROUNDThe use of electrophoresis to monitor monoclonal immunoglobulins migrating in the β fraction may be difficult because of their comigration with transferrin and complement proteins.METHODSImmunoassays specific for IgGκ, IgGλ, IgAκ, IgAλ, IgMκ, and IgMλ heavy/light chain (HLC) were validated for use in the clinical laboratory. We assessed sample stability, inter- and intraassay variability, linearity, accuracy, and reference intervals for all 6 assays. We tested accuracy by verifying that the sum of the concentrations for the HLC-pairs accounted for the total immunoglobulins in each of 129 healthy sera, and that the HLC-pair ratios (rHLCs) were outside the reference interval in 97% of 518 diagnostic multiple myeloma (MM) samples.RESULTSWe assessed diagnostic samples and posttreatment sera in 32 IgG and 30 IgA patients for HLC concentrations, rHLC, and total immunoglobulins and compared these nephelometry results with serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). In sample sets from patients with IgG MM, the sensitivity of SPEP was almost the same as for rHLC, and no additional advantage was conferred by running HLC assays. In pre- and posttreatment samples from patients with IgA MM, the SPEP, rHLC, and IFE identified clonality in 28%, 56%, and 61%, respectively. In addition, when M-spikes were quantifiable, the concentration of the involved HLC was linearly related to that of the SPEP M-spike, with a slope near 1.CONCLUSIONSThe use of IgA HLC assays for monitoring β-migrating IgA monoclonal proteins can substitute for the combination of SPEP, IFE, and total IgA quantification.
Phenotyping Polyclonal Kappa and Lambda Light Chain Molecular Mass Distributions in Patient Serum Using Mass Spectrometry
Barnidge, David R. , Dasari, Surendra , Ramı́rez-Alvarado, Marina , Fontan, Adrian, Tschumper, Renee C. , Jelinek, Diane F., Snyder, Melissa R., Dispenzieri, Angela , Katzmann, Jerry A., Murray, David , Willrich, Maria Alice V. , Snyder, Melissa R., Dispenzieri, Angela , Ramirez-Alvarado, Marina

Mayo Clinic

Journal of Proteome Research | August 19, 2014 | Volume: 13 | Issue: 11 | Pages: 5198-5205

10.1021/pr5005967 | PMID 25134970 Get It

Detecting monoclonal light chains in urine: microLC‐ESI‐Q‐TOF mass spectrometry compared to immunofixation electrophoresis
Botz, Chad M. , Barnidge, David R. , Murray, David , Katzmann, Jerry A.

Mayo Clinic

British Journal of Haematology | July 7, 2014 | Volume: 167 | Issue: 3 | Pages: 437-438

10.1111/bjh.13003 | PMID 25039602 Get It

Quantification of Serum IgG Subclasses by Use of Subclass-Specific Tryptic Peptides and Liquid Chromatography–Tandem Mass Spectrometry
Ladwig, Paula M. , Barnidge, David R. , Snyder, Melissa R. , Katzmann, Jerry A., Murray, David , Murray, David L.

Mayo Clinic

Clinical Chemistry | May 6, 2014 | Volume: 60 | Issue: 8 | Pages: 1080-1088

10.1373/clinchem.2014.222208 | PMID 24799527 Get It

AbstractBACKGROUNDMeasurement of IgG subclasses is a useful tool for investigation of humoral immune deficiency in the presence of total IgG within reference intervals and IgG4-related disease. Nephelometry has been the method of choice for quantification. We describe an LC-MS/MS method that can multiplex all 4 subclasses along with total IgG by use of either IgG subclass-specific peptide stable isotope–labeled internal standards or a surrogate digest standard for quantification and does not rely on antigen/antibody reactions.METHODSWe combined serum with labeled internal peptide standards and intact purified horse IgG. Samples were denatured, reduced, alkylated, and digested. We analyzed the digested serum by LC-MS/MS for IgG subclasses 1–4 and total IgG.RESULTSWe assayed 112 patient sera by LC-MS/MS and immunonephelometry. The mean of the slopes and R2 values for IgG1, IgG2, IgG3, IgG4, and IgG were 1.18 and 0.93, respectively. Interassay imprecision for the LC-MS/MS method was <15% for total IgG and subclasses and was slightly improved by use of a calibrator peptide from an exogenous horse IgG. Summed total IgG correlated with the measured total IgG within 10%. Reference intervals and analytical measuring range were all similar to our previous validation data for the immunonephelometry assays.CONCLUSIONSTotal IgG and IgG subclasses 1, 2, 3, and 4 can be quantified by LC-MS/MS with performance comparable to nephelometry.
Monitoring M-Proteins in Patients with Multiple Myeloma Using Heavy-Chain Variable Region Clonotypic Peptides and LC–MS/MS
Barnidge, David R. , Tschumper, Renee C. , Theis, Jason D. , Snyder, Melissa R., Jelinek, Diane F., Katzmann, Jerry A., Dispenzieri, Angela , Murray, David , Snyder, Melissa R., Dispenzieri, Angela

Mayo Clinic

Journal of Proteome Research | February 20, 2014 | Volume: 13 | Issue: 4 | Pages: 1905-1910

10.1021/pr5000544 | PMID 24552626 Get It

Using Mass Spectrometry to Monitor Monoclonal Immunoglobulins in Patients with a Monoclonal Gammopathy
Barnidge, David R. , Dasari, Surendra , Botz, Chad M. , Murray, Danelle H., Murray, Danelle H., Katzmann, Jerry A., Dispenzieri, Angela , Murray, David , Murray, Danelle H., Snyder, Michael , Dispenzieri, Angela

Mayo Clinic

Journal of Proteome Research | January 27, 2014 | Volume: 13 | Issue: 3 | Pages: 1419-1427

10.1021/pr400985k | PMID 24467232 Get It

Laboratory Persistence and Clinical Progression of Small Monoclonal Abnormalities
Murray, David , Seningen, Justin L., Dispenzieri, Angela , Snyder, Melissa R., Kyle, Robert A. , Rajkumar, S. Vincent , Katzmann, Jerry A., Snyder, Melissa R., Rajkumar, S Vincent , Dispenzieri, Angela

Mayo Clinic

American Journal of Clinical Pathology | September 24, 2012 | Volume: 138 | Issue: 4 | Pages: 609-613

10.1309/ajcpt6owwmhita1y | PMID 23010717 Get It