Citations

Clear

131 citation(s) found for "Morrey, BF".

Revision interposition arthroplasty of the elbow
Larson, A. Noelle , Adams, Robert , Morrey, B.F. , Larson, A Noelle

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | August 26, 2010 | Volume: 92-B | Issue: 9 | Pages: 1273-1277

10.1302/0301-620x.92b9.24039 | PMID 20798447 Get It

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow.
Failure of metal radial head replacement
Riet, R. P. van, Sanchez-Sotelo, Joachin, Morrey, B.F. , Riet, R. P. van, Sanchez-Sotelo, J.

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | April 30, 2010 | Volume: 92-B | Issue: 5 | Pages: 661-667

10.1302/0301-620x.92b5.23067 | PMID 20436003 Get It

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.
Determination of Muscle and Joint Forces: A New Technique to Solve the Indeterminate Problem
An, K.N. , Kwak, B. M. , Chao, E.Y.S., Morrey, B.F., Chao, En

Mayo Clinic

Journal of Biomechanical Engineering | July 7, 2009 | Volume: 106 | Issue: 4 | Pages: 364-367

10.1115/1.3138507 | PMID 6513533 Get It

Analytic determination of muscle force across human joints encounters an indeterminate problem. A new optimization approach, based on minimizing the upper bound of muscle stress, is introduced to obtain a unique solution. Mathematical and physiological justification of this new approach distinguishes it from previously described methods. A complex joint, the elbow, was studied. The results of muscle forces in resisting the elbow flexion moment were obtained and compared with electromyographic observation, as well as with solution from other optimizing techniques. The resultant humero-ulnar joint forces at various elbow joint positions are calculated. In normal daily activities, resultant joint forces of 0.3–0.5 times body weight are commonly encountered.
Electrogoniometer for the Measurement of Human Elbow Joint Rotation
Chao, Edmund Y.S., An, Kai‐Nan , Askew, Linda J., Morrey, B.F.

Mayo Clinic

Journal of Biomechanical Engineering | June 15, 2009 | Volume: 102 | Issue: 4 | Pages: 301-310

10.1115/1.3138227 | PMID 6965193 Get It

Since the electrogoniometric method has been justified for the measurement of lower extremity joint motion, a similar device is developed for the measurement of elbow joint and forearm rotations. In this design, the axis of forearm rotation coincides with the anatomical axis which eliminates the cross talk existing in the regular triaxial goniometer. Although the axis of abduction-adduction is still offset from the elbow joint, special linkage arrangement was used to obtain equivalent motion. Experimental method was used to validate the accuracy of the device and model simulation was performed to emphasize the importance of accurate placement of the instrument on test subjects. Application of the present apparatus to normal subjects was studied to illustrate the range of elbow motion required in performing normal activities of daily living. This device is currently used in the functional evaluation of patients with elbow and forearm problems.
Management and outcome of 103 acute fractures of the coronoid process of the ulna
Morrey, B.F. , Steinmann, Scott P. , Adams, Julie , Adams, Julie E. , Hoskin, Tanya L. , Adams, Julie E

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | April 30, 2009 | Volume: 91-B | Issue: 5 | Pages: 632-635

10.1302/0301-620x.91b5.21755 | PMID 19407298 Get It

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation. At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis.
Neurolysis of the ulnar nerve for neuropathy following total elbow replacement
Rispoli, Damian M., Morrey, B.F. , Athwal, George S.

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | September 30, 2008 | Volume: 90-B | Issue: 10 | Pages: 1348-1351

10.1302/0301-620x.90b10.21133 | PMID 18827246 Get It

Ulnar neuropathy presents as a complication in 5% to 10% of total elbow replacements, but subsequent ulnar neurolysis is rarely performed. Little information is available on the surgical management of persistent ulnar neuropathy after elbow replacement. We describe our experience with the surgical management of this problem. Of 1607 total elbow replacements performed at our institution between January 1969 and December 2004, eight patients (0.5%) had a further operation for persistent or progressive ulnar neuropathy. At a mean follow-up of 9.2 years (3.1 to 21.7) six were clinically improved and satisfied with their outcome, although, only four had complete recovery. When transposition was performed on a previously untransposed nerve the rate of recovery was 75%, but this was reduced to 25% if the nerve had been transposed at the time of the replacement.
Total elbow replacement for the management of the ankylosed or fused elbow
Peden, John P., Morrey, B.F.

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | August 31, 2008 | Volume: 90-B | Issue: 9 | Pages: 1198-1204

10.1302/0301-620x.90b9.19967 | PMID 18757960 Get It

This study reports our experience with total elbow replacement for fused elbows. Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically. A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful. Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations.
Osborne-Cotterill Lesion: An Osseous Defect of the Capitellum Associated with Instability of the Elbow
Micić, Ivan , Yamamoto, Nobuyuki , Morrey, B.F. , Jeon, In‐Ho

Mayo Clinic

American Journal of Roentgenology | August 20, 2008 | Volume: 191 | Issue: 3 | Pages: 727-729

10.2214/ajr.07.3739 | PMID 18716100 Get It

Capsular Properties of the Shoulder.
ITOI, FIJI, Grabowski, John, Morrey, B.F. , An, Kai‐Nan

Mayo Clinic

The Tohoku Journal of Experimental Medicine | March 12, 2008 | Volume: 171 | Issue: 3 | Pages: 203-210

10.1620/tjem.171.203 | PMID 8160176 Get It

Contribution of Axial Arm Rotation to Humeral Head Translation
Motzkin, Neil E., Morrey, B.F. , An, Kai‐Nan , Itoi, Eiji

Mayo Clinic

The American Journal of Sports Medicine | June 21, 2007 | Volume: 22 | Issue: 4 | Pages: 499-503

10.1177/036354659402200411 | PMID 7943515 Get It

The contribution of axial arm rotation to translation of the humeral head with the arm in the hanging position was examined using nine fresh-frozen cadaveric shoulders. Three standard clinical tests were simulated: anterior and posterior translation and sulcus tests. In both the anterior translation and sulcus tests, anterior and infe rior displacements were significantly restricted in inter nal rotation but not in neutral and external rotation. In the posterior translation test, no significant differences in displacement could be observed in internal, neutral, or external rotation. Since anterior and inferior translations of the humeral head were significantly affected by the rotation of the arm, we recommend that the anterior translation and sulcus tests be performed in various rotations.