Citations

Clear

162 citation(s) found for "Fletcher, Joel G".

Low‐dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
Bartley, Adam C. , Carter, Rickey E. , Chen, Baiyu , Drees, Tammy A., Edwards, Phillip K , Holmes, David R. , Huang, Alice E. , Khan, Farhana, McMillan, Kyle, Michalak, Gregory J. , Nunez, Kristina M., Yu, Lifeng , Edwards, Phillip, McMillan, Kyle L, Carter, Rickey E , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng , Fletcher, Joel G.

Mayo Clinic

Medical Physics | October 13, 2017 | Volume: 44 | Issue: 10 | Pages: No page available

10.1002/mp.12345 | PMID 29027235 Get It

Purpose Using common datasets, to estimate and compare the diagnostic performance of image‐based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases. Methods Datasets from contrast‐enhanced CT scans of the liver were provided to participants in an NIH ‐, AAPM ‐ and Mayo Clinic‐sponsored Low Dose CT Grand Challenge. Training data included full‐dose and quarter‐dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data. Projection data were supplied in a vendor‐neutral standardized format ( DICOM ‐ CT ‐ PD ). Twenty quarter‐dose patient datasets were provided to each participant for testing the performance of their technique. Images were provided to sites intending to perform denoising in the image domain. Fully preprocessed projection data and statistical noise maps were provided to sites intending to perform iterative reconstruction. Upon return of the denoised or iteratively reconstructed quarter‐dose images, randomized, blinded evaluation of the cases was performed using a Latin Square study design by 11 senior radiology residents or fellows, who marked the locations of identified hepatic metastases. Markings were scored against reference locations of clinically or pathologically demonstrated metastases to determine a per‐lesion normalized score and a per‐case normalized score (a faculty abdominal radiologist established the reference location using clinical and pathological information). Scores increased for correct detections; scores decreased for missed or incorrect detections. The winner for the competition was the entry that produced the highest total score (mean of the per‐lesion and per‐case normalized score). Reader confidence was used to compute a Jackknife alternative free‐response receiver operating characteristic ( JAFROC ) figure of merit, which was used for breaking ties. Results 103 participants from 90 sites and 26 countries registered to participate. Training data were shared with 77 sites that completed the data sharing agreements. Subsequently, 41 sites downloaded the 20 test cases, which included only the 25% dose data ( CTDI vol = 3.0 ± 1.8 mG y, SSDE = 3.5 ± 1.3 mG y). 22 sites submitted results for evaluation. One site provided binary images and one site provided images with severe artifacts; cases from these sites were excluded from review and the participants removed from the challenge. The mean (range) per‐lesion and per‐case normalized scores were −24.2% (−75.8%, 3%) and 47% (10%, 70%), respectively. Compared to reader results for commercially reconstructed quarter‐dose images with no noise reduction, 11 of the 20 sites showed a numeric improvement in the mean JAFROC figure of merit. Notably two sites performed comparably to the reader results for full‐dose commercial images. The study was not designed for these comparisons, so wide confidence intervals surrounded these figures of merit and the results should be used only to motivate future testing. Conclusion Infrastructure and methodology were developed to rapidly estimate observer performance for liver metastasis detection in low‐dose CT examinations of the liver after either image‐based denoising or iterative reconstruction. The results demonstrated large differences in detection and classification performance between noise reduction methods, although the majority of methods provided some improvement in performance relative to the commercial quarter‐dose images with no noise reduction applied.
Crohn’s Disease of the Pouch: A True Diagnosis or an Oversubscribed Diagnosis of Exclusion?
Lightner, Amy L., Pembérton, John H., Mathis, Kellie L. , Raffals, Laura E., Smyrk, Thomas, Lightner, Amy L. , Fletcher, Joel G. , Raffals, Laura E.

Mayo Clinic

Diseases of the Colon & Rectum | October 5, 2017 | Volume: 60 | Issue: 11 | Pages: 1201-1208

10.1097/dcr.0000000000000918 | PMID 28991085 Get It

BACKGROUND: After IPAA, 8% of patients with ulcerative colitis are later diagnosed with Crohn’s disease of the pouch, associated with an increased rate of pouch failure. No study has reported on how often the clinical diagnosis is correlated with histologic findings of Crohn’s disease in the excised pouch. OBJECTIVE: The purpose of this study was to determine whether the clinical diagnosis is consistent with pathologic confirmation at pouch excision. SETTINGS: The study was conducted at a tertiary IBD referral center. PATIENTS: Patients with chronic ulcerative colitis who underwent pouch excision for presumed Crohn’s disease of the pouch were included. MAIN OUTCOME MEASURES: Preoperative evaluation and pathologic variables at the time of pouch excision were measured. RESULTS: A total of 35 patients underwent pouch excision for Crohn’s disease of the pouch based on a combination of clinical, radiographic, and endoscopic findings. Seven (20%) had surgical pathology consistent with Crohn’s disease at pouch excision. There were no differences in those 7 patients and the remaining 28 in terms of diagnosis at colectomy, primary pouch symptoms, prepouch inflammation, ulceration, or granulomas at endoscopy. In the nonpathology-confirmed Crohn’s disease, 40% (n = 11) had an anastomotic leak at time of IPAA versus 0% in the Crohn’s disease group, and 86% (n = 24) had symptoms of pouch dysfunction within 5 months of ileostomy reversal versus 13 months in the Crohn’s disease group. Of 28 without pathology-confirmed Crohn’s disease, 100% (n = 28) were treated with antibiotics, 68% (n = 19) with steroids, 59% (n = 16) with immunomodulators, and 57% (n = 15) with biologic therapy for Crohn’s disease of the pouch. LIMITATIONS: The study was limited by its single-center scope and lack of an established definition for Crohn’s disease of the pouch. CONCLUSIONS: Pathologic confirmation of Crohn’s disease was given to only one fifth of patients who underwent pouch excision for Crohn’s disease of the pouch. Given the histologic variability in Crohn’s disease, it may be unreasonable to expect histologic confirmation in every case; still, the diagnosis of Crohn’s disease of the pouch may be overly ascribed, resulting in unnecessary immunosuppressive medications and exclusion from consideration for pouch reconstructive surgery. See Video Abstract at http://links.lww.com/DCRA432.
Endoscopic Skipping of the Terminal Ileum in Pediatric Crohn Disease
Mansuri, Ishrat , Bruining, David H. , Kolbe, Amy B. , Fidler, Jeff L. , Samuel, Sunil, Tung, Jeanne , Fletcher, Joel G. , Fidler, Jeff L.

Mayo Clinic

American Journal of Roentgenology | April 5, 2017 | Volume: 208 | Issue: 6 | Pages: W216-W224

10.2214/ajr.16.16575 | PMID 28379745 Get It

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT
Yu, Lifeng , Hu, Qiyuan , Koo, Chi Wan , Takahashi, Edwin A. , Levin, David L. , Johnson, Tucker F. , Hora, Megan J., Dirks, Shane, Chen, Baiyu , McMillan, Kyle, Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H. , Takahashi, Edwin A

Mayo Clinic

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101321R

10.1117/12.2255593 | PMID 28392614 Get It

A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Wells, Michael , Froemming, Adam T. , Vrtiska, Terri J., Hartman, Robert P. , Holmes, David R. , Carter, Rickey E. , Bartley, Adam C. , Wells, Michael L, Kawashima, Akira , Kim, Bohyun , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Carter, Rickey E

Mayo Clinic

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736 Get It

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
MR Imaging of Perianal Crohn Disease
Sheedy, Shannon P. , Bruining, David H. , Dozois, Eric J. , Faubion, William A. , Fletcher, Joel G.

Mayo Clinic

Radiology | February 28, 2017 | Volume: 282 | Issue: 3 | Pages: 628-645

10.1148/radiol.2016151491 | PMID 28218881 Get It

Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality
Vasconcelos, Rogerio N., Vrtiska, Terri J., Foley, Thomas A. , Macedo, Thanila A. , Cardona, Juan C. Montoya, Williamson, Eric E. , Vasconcelos, Rogerio, McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 | PMID 28225687 Get It

Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction
Stinson, Eric G. , Trzasko, Joshua D. , Riederer, Stephen J. , Fletcher, Joel G.

Mayo Clinic

Magnetic Resonance in Medicine | February 2, 2017 | Volume: 78 | Issue: 6 | Pages: 2203-2215

10.1002/mrm.26620 | PMID 28150873 Get It

PurposeThe purpose of this work is to derive and demonstrate constrained‐phase dual‐echo Dixon imaging within a maximum likelihood framework solved with a regularized graph‐cuts‐guided optimization.Theory and MethodsDual‐echo Dixon reconstruction is fundamentally underdetermined; however, adopting a constrained‐phase signal model reduces the number of unknowns and the nonlinear problem can be solved under a maximum likelihood framework. Period shifts in the field map (manifesting as fat/water signal swaps) must also be corrected. Here, a regularized cost function promotes a smooth field map and is solved with a graph‐cuts‐guided greedy binary optimization. The reconstruction shown here is compared to two other prevalent Dixon reconstructions in experimental phantom and human studies.ResultsReconstructed images of the water and fat signal are shown for a phantom study, and in vivo studies of foot/ankle, pelvis, and CE‐MRA of the thighs. The method shown here compared favorably with the other two methods. Large field inhomogeneities on the order of 20 ppm were resolved, thereby avoiding the fat and water signal swaps present in images reconstructed with the other methods.ConclusionConstrained‐phase dual‐echo Dixon imaging solved with a regularized graph‐cuts‐guided optimization has been derived and demonstrated to successfully separate water and fat images in the presence of large magnetic field inhomogeneities. Magn Reson Med 78:2203–2215, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
First PET Imaging Studies With 63 Zn-Zinc Citrate in Healthy Human Participants and Patients With Alzheimer Disease
DeGrado, Timothy R. , Kemp, Bradley J. , Pandey, Mukesh K. , Jiang, Huailei , Gunderson, Tina M. , Linscheid, Logan, Woodwick, Allison R., McConnell, Daniel, Johnson, Geoffrey B. , Petersen, Ronald C. , Lowe, Val J. , Linscheid, Logan R, McConnell, Daniel M, Fletcher, Joel G. , Knopman, David S. , Johnson, Geoffrey B , Pandey, Mukesh K , Jiang, Huailei

Mayo Clinic

Molecular Imaging | December 10, 2016 | Volume: 15 | Issue: No issue available | Pages: No page available

10.1177/1536012116673793 | PMID 27941122 Get It

Abnormalities in zinc homeostasis are indicated in many human diseases, including Alzheimer disease (AD). 63 Zn-zinc citrate was developed as a positron emission tomography (PET) imaging probe of zinc transport and used in a first-in-human study in 6 healthy elderly individuals and 6 patients with clinically confirmed AD. Dynamic PET imaging of the brain was performed for 30 minutes following intravenous administration of 63 Zn-zinc citrate (∼330 MBq). Subsequently, body PET images were acquired. Urine and venous blood were analyzed to give information on urinary excretion and pharmacokinetics. Regional cerebral 63 Zn clearances were compared with 11 C-Pittsburgh Compound B ( 11 C-PiB) and 18 F-fluorodeoxyglucose ( 18 F-FDG) imaging data. 63 Zn-zinc citrate was well tolerated in human participants with no adverse events monitored. Tissues of highest uptake were liver, pancreas, and kidney, with moderate uptake being seen in intestines, prostate (in males), thyroid, spleen, stomach, pituitary, and salivary glands. Moderate brain uptake was observed, and regional dependencies were observed in 63 Zn clearance kinetics in relationship with regions of high amyloid-β plaque burden ( 11 C-PiB) and 18 F-FDG hypometabolism. In conclusion, zinc transport was successfully imaged in human participants using the PET probe 63 Zn-zinc citrate. Primary sites of uptake in the digestive system accent the role of zinc in gastrointestinal function. Preliminary information on zinc kinetics in patients with AD evidenced regional differences in clearance rates in correspondence with regional amyloid-β pathology, warranting further imaging studies of zinc homeostasis in patients with AD.
Evaluation of Patient Tolerance and Small-Bowel Distention With a New Small-Bowel Distending Agent for Enterography
Kolbe, Amy B. , Froemming, Adam T. , Sheedy, Shannon P. , Koo, Chi Wan , Pundi, Krishna , Bruining, David H. , Harmsen, William S. , Barlow, John M. , Fidler, Jeff L. , Tung, Jeanne , Fletcher, Joel G. , Fidler, Jeff L. , Pundi, Krishna

Mayo Clinic

American Journal of Roentgenology | March 21, 2016 | Volume: 206 | Issue: 5 | Pages: 994-1002

10.2214/ajr.15.15260 | PMID 26998661 Get It