Citations

Clear

124 citation(s) found for "Arunachalam, S P".

Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

Mayo Clinic

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
Multiscale Entropy Technique Discriminates Single Lead ECG’s With Normal Sinus Rhythm and Sleep Apnea
Shivaram, Suganti, Muthyala, Anjani, Meghji, Zahara, Karki, Susan, Arunachalam, S P , Arunachalam, Shivaram P.

Mayo Clinic

2018 Design of Medical Devices Conference | July 30, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2018-6948 Get It

Sleep apnea is characterized by abnormal interruptions in breathing during sleep due to partial or complete airway obstructions affecting middle-aged men and women on an estimated ∼4% of the population [1]. While the disorder is clinically manageable to relieve patients, the challenge occurs with diagnosis, with many patients going undiagnosed leading to further complications such as ischemic heart diseases, stroke etc. Sleep apnea also significantly affects the quality of day to day life causing sleepiness and fatigue. Polysomnography (PSG) technique is currently a used for detecting sleep apnea which is a comprehensive sleep test to diagnose sleep disorders by recording brain waves, the oxygen level in the blood, heart rate, breathing, eye and leg movements during the study. However, PSG test is very expensive, requires patients to stay overnight and is known to cause inconvenience to the patients.
MRI feature tracking strain is prognostic for all-cause mortality in AL amyloidosis
Illman, Jeffery E., Arani, Arvin , Chang, Ian C , Glockner, James F., Grogan, Martha , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Chang, Ian Cheng-Yi , Dispenzieri, Angela , Grogan, Martha , Araoz, Philip A , Arunachalam, Shivaram P. , Dispenzieri, Angela

Mayo Clinic

Amyloid | May 7, 2018 | Volume: 25 | Issue: 2 | Pages: 101-108

10.1080/13506129.2018.1465406 | PMID 29733684 Get It

Improved Multiscale Entropy Technique with Nearest-Neighbor Moving-Average Kernel for Nonlinear and Nonstationary Short-Time Biomedical Signal Analysis
Mulpuru, Siva K. , Friedman, Paul A. , Tolkacheva, Elena G. , Arunachalam, S P , Tolkacheva, E G , Arunachalam, Shivaram P. , Kapa, Suraj

Mayo Clinic

Journal of Healthcare Engineering | March 5, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-13

10.1155/2018/8632436 | PMID 29707188 Get It

Analysis of biomedical signals can yield invaluable information for prognosis, diagnosis, therapy evaluation, risk assessment, and disease prevention which is often recorded as short time series data that challenges existing complexity classification algorithms such as Shannon entropy (SE) and other techniques. The purpose of this study was to improve previously developed multiscale entropy (MSE) technique by incorporating nearest-neighbor moving-average kernel, which can be used for analysis of nonlinear and non-stationary short time series physiological data. The approach was tested for robustness with respect to noise analysis using simulated sinusoidal and ECG waveforms. Feasibility of MSE to discriminate between normal sinus rhythm (NSR) and atrial fibrillation (AF) was tested on a single-lead ECG. In addition, the MSE algorithm was applied to identify pivot points of rotors that were induced in ex vivo isolated rabbit hearts. The improved MSE technique robustly estimated the complexity of the signal compared to that of SE with various noises, discriminated NSR and AF on single-lead ECG, and precisely identified the pivot points of ex vivo rotors by providing better contrast between the rotor core and the peripheral region. The improved MSE technique can provide efficient complexity analysis of variety of nonlinear and nonstationary short-time biomedical signals.
Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Mayo Clinic

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 | PMID 29194738 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Robust Discrimination of Normal Sinus Rhythm and Atrial Fibrillation on ECG Using a Multiscale Frequency Technique
Arunachalam, Shivaram P. , Annoni, Elizabeth M., Mulpuru, Siva K. , Friedman, Paul A. , Tolkacheva, Elena G. , Arunachalam, S P , Kapa, Suraj

Mayo Clinic

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3302 Get It

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia affecting approximately 3 million Americans, and is a prognostic marker for stroke, heart failure and even death [1]. 12-lead electrocardiogram (ECG) is used to monitor normal sinus rhythm (NSR) and also detect AF. Although the persistent form of AF can be detected relatively easy, detecting paroxysmal AF is often a challenge since requiring continuous monitoring, which becomes expensive and cumbersome to collect lot of ECG data [1]. Several researchers have attempted to develop new methods to discriminate NSR and AF which are based on R-R interval analysis, linear methods, filtering, spectral analysis, statistical approaches such as entropy etc. which faces limitation of successfully detecting AF of all types with high sensitivity and specificity using short time ECG data [1–3]. The major issues with these approaches is that they often distort the ECG by several pre-processing steps with filters, do not provide reliable discrimination using short ECG time series data and many of them lack real-time capability that makes it difficult to trust the data for diagnosis and treatment. Both clinical and scientific communities recognize these difficulties and the necessity to develop novel methods that can enable accurate monitoring and detection of AF [2]. In addition, robust detection and classification algorithms are essential for delivering appropriate therapy for implantable cardioverter defibrillators (ICD) to provide lifesaving timely action. In this work, the authors propose and demonstrate the application of a multiscale frequency (MSF) approach [4] for accurate detection and discrimination between AF and NSR ECG traces taken from publically available Physionet database. The MSF approach takes into account the contribution from various frequencies in ECG and thus yield valuable information regarding the chaotic nature of AF. Therefore, we demonstrate that MSF can capture the complexity of AF which is associated with higher MSF value compared with NSR thus enabling robust discrimination e AF manifests itself with numerous chaotic frequencies within the body surface ECG,. We validate the feasibility of this technique to discriminate NSR from AF.
Optimizing Emergency Department Workflow Using Radio Frequency Identification Device (RFID) Data Analytics
Arunachalam, Shivaram P. , Sır, Mustafa Y. , Marisamy, Gomathi, Sadosty, Annie T., Nestler, David M. , Hellmich, Thomas , Arunachalam, S P , Pasupathy, Kalyan S.

Mayo Clinic

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3402 Get It

Emergency Department (ED) is a complex care delivery environment in a hospital that provides time sensitive urgent and lifesaving care [1]. Emergency medicine is an unscheduled practice and therefore providers experience extreme fluctuations in their workload. ED crowding is a major concern that affects the efficacy of the ED workflow, which often is challenged by long wait times, overuse of observation units, patients either leaving without being seen by a provider and non-availability of inpatient beds to accommodate patients after diagnosis [2]. Evaluating ED workflow is a challenging task due to its chaotic nature, with some success using time-motion studies and novel capacity management tools are nowadays becoming common in ED to address workflow related issues [3]. Several studies reveal that Electronic Medical Record (EMR) adoption has not resulted in significant ED workflow improvements nor reduced the cost of ED operations. Since raw EMR data does not offer operational and clinical decision making insights, advanced EMR data analytics are often sought to derive actionable intelligence from EMR data that can provide insights to improve ED workflow. Improving ED workflow has been an important topic of research because of its great potential to optimize the urgent care needed for the patients and at the same time save time and cost. Radio Frequency Identification Device (RFID) is a wireless automatic identification and data capture technology device that has the potential for improving safety, preventing errors, saving costs, and increasing security and therefore improving overall organizational performance. RFID technology use in healthcare has opened a new space in healthcare informatics research that provides novel data to identify workflow process pitfalls and provide new directions [4]. The potential advantages of RFID adoption in healthcare and especially in ED has been well recognized to save costs and improve care delivery [5]. However, the large upfront infrastructure costs, need for an integrated health information technology (HIT), advanced analytical tools for big data analysis emerging from RFID and skilled data scientists to tackle the data to derive actionable intelligence discourage many hospitals from adoption RFID technology despite its potential advantages. Our recent pilot study on the RFID data analytics demonstrated the feasibility of quantifying and analyzing two novel variables such as ‘patient alone’ time defined as the total time a patient spends alone without interaction with a health care staff in the ED and ‘provider time’ defined as the total time a patient spends interacting with any health care staff [6]. The study motivated a more comprehensive big data analytics of RFID data which can provide better insights into optimizing ED workflow which can improve the quality of care in the ED and also reduce cost. In this work, the authors attempt to describe the RFID adoption in the ED at the Saint Mary’s Hospital at Mayo Clinic, in Rochester, MN, a level one trauma center both for children and adults as a step towards optimizing ED workflow.
Feasibility study of cardiac magnetic resonance elastography in cardiac amyloidosis
Chang, Ian C , Arani, Arvin , Arunachalam, Shivaram P. , Grogan, Martha , Araoz, Philip A. , Chang, Ian C Y, Poigai Arunachalam, Shivaram, Dispenzieri, Angela , Arunachalam, S P , Arani, Arvin

Mayo Clinic

Amyloid | April 22, 2017 | Volume: 24 | Issue: sup1 | Pages: 161-161

10.1080/13506129.2017.1278689 | PMID 28434361 Get It

Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction
Arunachalam, Shivaram P. , Arani, Arvin , Baffour, Francis , Rysavý, J, Rossman, Phillip J. , Glaser, Kevin J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Rysavy, Joseph A, Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Mayo Clinic

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 | PMID 28382658 Get It

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.