Citations

Clear

3030 citation(s) found for "Susan, M".

Abstract 16138: Chest and Cardiac Compression on CT/MRI and on TEE Predicts Improvement in Right Heart Chamber Size and Right Ventricular Deformation Post Pectus Excavatum Repair Surgery
Jaroszewski, Dawn E. , Lester, S.C., Unzek, Samuel , Wilansky, Susan , Chaliki, Hari P. , Appleton, Christopher P., Mookadam, Farouk , Naqvi, Tasneem Z. , Chao, Chieh‐Ju , Gotway, Michael B. , Lester, Steven

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16138 Get It

Background: Pectus excavatum (PE) deformity involves posterior depression of the sternum and adjacent costal cartilages. The relationship of CT/MRI chest cardiac compression indices used as indications for surgical repair of PE with echocardiographic findings and with improvement in cardiac chamber compression and function post PE repair is unknown. Methods: We evaluated right atrial (RA) size, tricuspid annulus (TA size, right ventricular (RV) outflow tract size as well as RV 2D strain on intra-operative trans-esophageal echocardiography (TEE) immediately pre and post surgical PE repair. Inspiratory and expiratory Haller Index (HI) and cardiac compression indices (CCI) were measured on pre op CT/MR scans (Figure). Offline measurement of chamber dimensions on TEE images was performed and Speckle tracking strain measurements were made using Syngo US Workplace software (Siemens). P<0.05 was considered significant. Results: 60 patients, 73% male, 27% female, age 33.6±10.3 yrs underwent PE repair following CT/MRI from 2010-2014 (Figure). There was a strong correlation between expiratory CT/MRI chest AP diameter and pre-op RA size (panel A). Pre op RA and TA compression on TEE inversely correlated with pre op RV global longitudinal strain rate(RVGLSR) (panels B & C). CCI predicted improvement in RA size post PE repair (panels D & E). In addition pre op RA size on TEE correlated with improvement in RVGLSR post PE repair surgery (panel F). Conclusion: In patients with PE deformity, pre surgical CCI correlated with right-sided cardiac chamber compression on pre op TEE. Severity of chest and cardiac compression also predicted magnitude of improvement in right-sided chamber size and RV longitudinal deformation post PE repair. Our findings provide insight regarding the beneficial effects of PE surgery on right heart chamber compression and improvement in RV function and the important role of intraoperative TEE for patients undergoing PE repair surgery.
Abstract 15693: Comorbidities in Heart Failure: A Population-Based Case-control Study
Boyd, Cynthia M. , Manemann, Sheila M., Killian, Jill M. , Weston, Susan A., Roger, Véronique L. , Chamberlain, Alanna M. , Dunlay, Shannon M. , Gerber, Yariv

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.15693 Get It

Background: Whether age alone explains the comorbidity burden in heart failure (HF) is unclear. In particular, differences in the burden of co-morbid conditions in HF patients compared to population controls has not been well documented. Methods: The prevalence of 17 chronic conditions defined by the US Department of Health and Human Services were obtained in 1746 incident HF patients from 2000-2010 and controls matched 1:1 on sex and age from Olmsted County, MN. Conditions were ascertained requiring 2 occurrences of a diagnostic code. Logistic regression determined associations of each condition with HF. Results: Among the 1746 matched pairs (mean age 76.2 years, 43.5% men), the prevalence was higher in HF cases for all conditions (p<0.05) except dementia and osteoporosis. After adjusting for all conditions, hypertension, coronary artery disease, arrhythmia, asthma, chronic kidney disease, chronic obstructive pulmonary disease, diabetes, hepatitis, and substance abuse were significantly more common in HF (figure). More than a 2-fold increased odds of hepatitis, arrhythmia, and coronary artery disease was observed among HF cases. Arrhythmia (34.2%), hypertension (31.1%), and coronary artery disease (27.8%) had the largest attributable risk of HF; for example, assuming a causal relationship, if arrhythmias were eliminated, 34% of HF would be avoided. Conclusions: Compared to age- and sex-matched controls, HF patients have a higher prevalence of many chronic conditions, indicating the excess comorbidity in HF is not due to age alone. Some cardiovascular conditions, including arrhythmia, coronary artery disease, and hypertension were more common in HF. Of the non-cardiovascular conditions, hepatitis had the strongest association with HF and was an unanticipated finding that deserves additional investigation. It is important to understand comorbidities as they play a key role in the excess mortality and healthcare utilization experienced by HF patients.
Abstract 12443: In-Beam PET Verification of Catheter-free Arrhythmia Ablation by Scanned Carbon-12 Ion Beam Irradiation
Fiedler, F. , Helmbrecht, S. , Constantinescu, A., Lugenbiel, Patrick , Prall, Matthias, Kaderka, Robert, Takami, Mitsuru , Eichhorn, Anna, Thomas, Dierk , Katus, Hugo A. , Johnson, Susan B., Parker, Kay, Asirvatham, Samuel, Packer, Douglas L. , Lehmann, H. Immo , Graeff, Christian , Prall, M. W., Richter, Daniel , Parker, Kay, Debus, Jürgen , Bert, Christoph , Durante, Marco

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12443 Get It

Introduction: Highly precise irradiation using carbon-12 (12C) ions is a new means for catheter-free ablation. Besides energy deposition leading to the dose distribution, nuclear interactions lead to by-product β+-activity that can be measured using positron-emission-tomography (PET). Hypothesis: In-beam PET scanning during focused myocardial irradiation using 12C can adequately depict 12C dose deposition. Methods: Pigs were irradiated with 25, 40, and 55 Gy for AV node (AVN), LA-PV junction, and local LV freewall ablations. PET measurement was performed by means of a double head camera system installed at irradiation site. Coincidences were captured in end-expiration during beam extraction pauses of the accelerator. Results: Evaluation of PET images was qualitatively performed using the coronal plane of the activity distribution superimposed on the contrast-CT in the center of the target contour. Strong β+-activities were measured in AVN and LV ablations. In AVN ablations, activity was localized to the target location, without target activity spreading to the level of the aortic root or coronary sinus (Figure A). Local LV irradiations revealed strong activity in the target location, slightly extending into left lung and chest wall (Figure B). In 55 Gy animals, the cardiac entry channel showed increased activity, decreasing in 40 Gy and more so in 25 Gy animals. Conclusion: This is the first study applying in-beam PET to track 12C dose-deposition into the target location for catheter-free ablation in intact animals. Correlation of β+-activity to electrophysiological outcome, lesion induction, and potential side-effects may be critically important in dosing therapy and predicting outcomes.
Abstract P442: Apparently Healthy Fit Asymptomatic Adults Are Not Immune To Sub-clinical Atherosclerosis
Scales, Robert , Cornella, Kathryn A, Vardhini, Mohan, Wu, Qing , Halli, Susan, Hurst, R. Todd, Akalan, Cengiz

Mayo Clinic

Circulation | July 3, 2021 | Volume: 129 | Issue: suppl_1 | Pages: No page available

10.1161/circ.129.suppl_1.p442 Get It

Evidence suggests that cardiovascular (CV) fitness below the 20 th percentile for age and gender is associated with increased cardiac death and all cause mortality. This study assessed the association between CV fitness and sub-clinical atherosclerosis (SCA) in a self-selected group of participants in a cardiology-based prevention program. The study involved a single visit observation of participants. 240 apparently healthy asymptomatic adults <65 years (69% male) received a maximal graded exercise stress test and a carotid intima-media thickness (CIMT) evaluation with B-mode ultrasound. CV fitness was classified based on age-gender norms (very poor=1-19 th , poor=20-39 th , fair=40-59 th , good=60-79 th , excellent/superior=80-100 th percentile). CIMT was used to define CV health based on age-gender-race norms. SCA was considered present when there was non-occlusive carotid artery plaque (>1.5mm and >50% of the surrounding intima-media) or CIMT >75 th percentile. Anyone with a prior history of clinically apparent atherosclerosis or diabetes was excluded from the study. The mean age of participants was 50 yrs (SD= 8.7). 113 participants (47%) had excellent/superior CV fitness. 41 (17%) were classified good, 36 (15%) fair, 20 (8%) poor and 30 (12%) very poor. 69 (61%) participants with excellent/superior CV fitness had advanced atherosclerosis (plaque=43%; n=49 or CIMT >75 th percentile=l7%; n=20). In the good classification there were 26 (64%) with plaque (49%; n=20) or CIMT >75 th percentile (15%; n=6). There were 23 (63%) in the fair classification with plaque (44%; n=16) or CIMT >75 th percentile (19%; n=7), 11 (55%) in the poor classification with plaque (45%; n=9) or CIMT >75 th percentile (10%; n=2) and 17 (56%) in the very poor classification with plaque (53%; n=16) or CIMT >75 th percentile (3%; n=1). 58 (24%) of the total number of participants were classified with superior CV fitness (95-100 th percentile); of which 36 (62%) had SCA (plaque=45%; n=26 or CIMT >75 th percentile=17%; n=10). In this self-selected population, CIMT testing detected evidence of SCA across all age-gender fitness classifications, which included very fit individuals. Further investigation is needed to identify other factors that may be associated with increased CV risk in apparently healthy fit asymptomatic adults.
Abstract P351: Inflammation and Stroke Risk in the Reasons for Geographic and Racial Differences in Stroke (REGARDS) Study
Jenny, Nancy S., Lakoski, Susan G., CALLAS, PETER W. , Zakai, Neil A. , McClure, Leslie A. , Judd, Suzanne E. , Kissela, Brett , Meschia, James F. , Cushman, Mary

Mayo Clinic

Circulation | July 3, 2021 | Volume: 129 | Issue: suppl_1 | Pages: No page available

10.1161/circ.129.suppl_1.p351 Get It

Background: Levels of the pro-inflammatory cytokines interleukin (IL)-6 and IL-8 and the anti-inflammatory cytokine IL-10 are altered in acute stroke patients compared to controls. However, results for IL-10 are inconsistent (higher in stroke patients compared to controls in some studies and decreased in others) and very few studies have examined associations of these biomarkers with risk of incident stroke. Methods: We examined associations of baseline levels of IL-6, IL-8 and IL-10 with stroke risk factors and risk of incident stroke in 1,572 white and black men and women from the REGARDS Study; an observational cohort of 30,239 adults followed for 5 years. Among those without prebaseline stroke, stroke cases (n=592, 53% men, 59% white, mean age 70 years) were compared to a cohort random sample (n=980, 44% men, 58% white, mean age 65 years). We used Cox proportional hazards models to examine associations of biomarkers with incident stroke. Hazard ratios (HR; 95% confidence intervals) for highest compared to lowest quartile for each biomarker are presented. Results: Baseline IL-6 was significantly higher in incident stroke cases compared to the cohort sample (p<0.001) while IL-8 and IL-10 levels did not vary significantly (p>0.05 for both). Adjusting for age, sex and race, IL-6 was higher in blacks compared to whites and higher in current smokers compared to never/former smokers (all p≤0.01). IL-6 was inversely associated with physical activity, alcohol use and education (all p≤0.01). IL-8 and IL-10 did not vary significantly with the risk factors examined. Adjusting for age, sex and race, the HR for risk of incident stroke in those in the highest compared to lowest quartile of IL-6 was 2.4 (1.6-3.4). HRs for IL-8 and IL-10 were 1.5 (1.0-2.1) and 1.4 (1.0-1.9), respectively. Adjusting for Framingham stroke risk factors and history of coronary heart disease, only IL-6 remained significantly associated with stroke risk (HR 2.0; 1.3-3.2). HRs for IL-8 and IL-10 were 1.1 (0.7-1.6) and 1.2 (0.8-1.8), respectively. IL-6 remained significantly associated with stroke risk when C-reactive protein was added to the model (HR 1.7; 1.1-2.7). Associations did not differ by race. Conclusions: In this population-based sample of US black and white adults, IL-6, but not IL-8 or IL-10, was associated with stroke risk factors and risk of incident stroke. Further study is needed on the clinical utility of IL-6 measurement in stroke risk assessment.
Abstract P380: Coronary Artery Disease Extent is Predictive of Heart Failure Incidence After Myocardial Infarction
Weston, Susan A., Manemann, Sheila M., Jiang, Ruoxiang , Roger, Véronique L. , Gerber, Yariv , Enriquez‐Sarano, Maurice , Chamberlain, Alanna M.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 131 | Issue: suppl_1 | Pages: No page available

10.1161/circ.131.suppl_1.p380 Get It

Background: Little is known about the association between coronary artery disease (CAD) and the risk of heart failure (HF) after myocardial infarction (MI), and whether it differs by reduced (HFrEF) or preserved (HFpEF) ejection fraction (EF) has yet to be determined. Subjects and Methods: Olmsted County, Minnesota residents (n=1,924; mean age, 64 years; 66% male) with first MI diagnosed in 1990-2010 and no prior HF were followed through 2013. Framingham Heart Study criteria were used to define HF, which was further classified according to EF (applying a 50% cutoff). The extent of angiographic CAD was defined at index MI according to the number of major epicardial coronary arteries with ≥50% lumen diameter obstruction. Fine & Gray and Cox proportional hazards regression models were used to assess the association of CAD categories with incidence of HF, and multiple imputation methodology was applied to account for the 19% with missing EF data. Results: During a mean (SD) follow-up of 6.7 (5.9) years, 594 patients developed HF. Adjusted for age and sex, with death considered a competing risk, the cumulative incidence rates of HF among patients with 1- (n=581), 2- (n=622), and 3-vessel disease (n=721) were 11.2%, 14.6% and 20.5% at 30 days; and 18.1%, 22.3% and 29.4% at 5 years after MI, respectively. The increased risk of HF with greater number of occluded vessels was only modestly attenuated after further adjustment for patient and MI characteristics, and did not differ materially by EF (Table). Conclusions: The extent of angiographic CAD expressed by the number of diseased vessels is independently associated with HF incidence after MI. The association is evident promptly after MI and applies to both HFrEF and HFpEF.
Abstract P108: Comorbidity Burden in Atrial Fibrillation: A Population-Based Case-Control Study
Byrne, Margaret C., Manemann, Sheila M., Killian, Jill M. , Weston, Susan A., Roger, Véronique L. , Chamberlain, Alanna M. , Byrne, Margaret C, Alonso, Álvaro , Gersh, Bernard J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 131 | Issue: suppl_1 | Pages: No page available

10.1161/circ.131.suppl_1.p108 Get It

Background: Differences in the prevalence and duration of co-morbid conditions in atrial fibrillation (AF) patients compared to population controls have not been well documented. Methods: The prevalence and duration of 17 chronic conditions defined by the US Department of Health and Human Services, as well as anxiety, obesity, and smoking status, was obtained in a random sample of 1430 patients with incident AF from 2000-2010 and 1430 controls from Olmsted County, MN. Controls were matched to cases 1:1 on sex and age (within 5 years). Chronic conditions were ascertained electronically requiring 2 occurrences of a diagnostic code; the duration of each condition (up to 25 years) was calculated. Logistic regression determined associations of each condition with AF after adjustment for all other conditions. Results: Among the 1430 matched pairs (median age 76 years, 48.6% men), the prevalence of chronic conditions was higher in AF cases compared to controls for all conditions except asthma, dementia, depression, hepatitis, and osteoporosis (figure). However, the duration of the conditions were similar in AF compared to controls, except for hypertension (median duration 12.3 and 9.9 years in AF cases and controls, respectively; p=0.002). After adjusting for all other conditions, obesity, hypertension, congestive heart failure, coronary artery disease, chronic kidney disease, and chronic obstructive pulmonary disease remained significantly more common in AF compared to controls (figure). Conditions with the largest attributable risk of AF were hypertension (25.4%), coronary artery disease (17.7%), and congestive heart failure (12.3%). Conclusions: AF patients have a higher prevalence of many chronic conditions compared to population controls. However, besides hypertension, these comorbidities do not develop earlier in AF. Nevertheless, the excess comorbidity burden in AF is important to characterize and understand as it may partly explain the excess mortality and healthcare utilization experienced by AF patients.
Abstract 3588: Treatment of Diabetes and Outcome After Myocardial Infarction: A Community Study
Patch, Richard K. , Arruda‐Olson, Adelaide M. , Leibson, Cynthia L., Weston, Susan A., Killian, Jill M. , Frye, Robert L. , Roger, Véronique L. , Vella, Adrian

Mayo Clinic

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_812-c Get It

BACKGROUND Epidemiological cohorts can assist with post-marketing surveillance as they provide community-based outcomes data. Concern was raised about the adverse impact of sulfonylureas (SU) drugs on the outcome of diabetes after myocardial infarction (MI). We evaluated the outcome of MI according to treatment among diabetic persons compared to non-diabetic counterparts in a community-based cohort. METHODS All MIs that occurred in Olmsted County, MN between 1979 and 2002 were validated by standardized epidemiological including cardiac pain, biomarkers and ECG Minnesota coding. Diabetes mellitus (DM) was defined by the National Diabetes Data Group criteria. RESULTS Among 2732 persons with MI (mean age 70 ± 12 years, 44% men), 486 (18%) had DM. Subjects with DM were treated with second generation SU (SU2) (24%), insulin (47%) or diet alone (22%) Diabetic subjects were more likely to be overweight, hyperlipidemic and to receive reperfusion therapy during hospitalization than non-diabetic subjects. One year after the MI, 518 subjects died. Diabetic subjects taking SU2 experienced better survival than subjects without diabetes, while subjects treated with diet alone or insulin experienced worse survival. (Figure ). After adjusting for age, sex, reperfusion and duration of DM, an excess risk of death was detected among persons with insulin-treated DM, particularly those with long-standing DM. No association was found for DM patients treated with SU2 or diet. CONCLUSION These data do not support the concern for an adverse impact of SU2 on survival and underscore the potential role of community studies for population surveillance.
Abstract 3229: First Time Validation of Point to Point NavX Map Registration to 3D Subject-Specific Computed Tomography (CT)
Kolasa, Mark, Johnson, Susan B., Olson, Eric, Schweitzer, Jeffrey S. , Packer, Douglas L. , Okumura, Yasuo , Schweitzer, Jeffrey

Mayo Clinic

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_726-c Get It

Background: Current mapping systems use simultaneous displays of overlapping 3D maps and pre-acquired CT images of the LA to “pseudo-register” data sets rather than specifically “register” each point of one mapping data set to the other. The appropriateness of the 2 data set match has not been validated. Since significant surface to surface mismatch errors may occur, this study was undertaken to quanititatively validate NavX map to CT registration and determine its suitability for guiding AF ablation. Methods: Sixty-four slice, multidetector CT scans were acquired in 8 dogs and segmented to establish subject-specific LA/PV volumes for importation into the EnSite mapping system. A detailed multi-surface geometry (NavX map) was collected by navigating a mapping catheter in target LA and PVs. Using a novel developmental registration algorithm the map was registered to LA/PV CT volume. Validation was performed using the registered 3D CT model for the guidance of ablation at the location of multiple implanted radio-opaque markers. Results: A total of 39 radio-opaque markers were implanted before CT including 9 LSPV, 8 RSPV, 7 RIPV, 9 LIPV, 3 roof, and 3 LAA locations. Subsequent registration of individual NavX maps to acquired 3D CT volume was successfully completed in all animals. RF ablations were performed at the predicted 3D registered model locations of the radio-opaque markers using 5 mm tip RF ablation catheter. Resulting mean lesion size was 5.3 x 6.5 mm. The lesions enveloped the point of marker attachment to the myocardium in 31/36 (86%) ablations. The average distance from the center of the RF lesion to the targeted site was 2.5 ± 1.5mm. 47 points were successfully navigated under fluorscopic and ICE guidance. All points were accurately portrayed on the 3D registered model. 3 points in the region of the RSPV floor did have minor offsets on the model due to technically difficult segmentation of the RSPV from the right pulmonary artery. Conclusion: These data demonstrate the feasibility of registering NavX derived geometries to CT data sets accommodating sources of cardiac, respiratory, and translational cycle dependent error. Catheter navigation precisely conducted using the registered model demonstrates accuracy within the range required for RF ablation.
Abstract 3223: Feasibility and Safety of the Integrated 3D Image and Contact Force-Guided Ablation for Atrial Fibrillation with the Hansen Robotic Catheter Sheath System
Henz, Benhur Davi , Johnson, Susa B, Packer, Douglas L. , Okumura, Yasuo , Johnson, Susan B.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_725-a Get It

Background: Current technologies to fully “register” surrogate maps onto 3D CT (CartoMerge, NavxMerge) or 3D ICE images (CartoSound) have emerged to guide ablation. The feasibility of navigation with the Hansen Robotic Catheter Sheath System (HRCS) has also been reported. Integrated 3D Image and contact force sensor with this robotic system may allow for feasibility and safety for guiding complex anatomic-based ablation. Methods: Circumferential pulmonary vein (PV) ablation with the robotic system guided by integrated 3D images (CartoMerge, NavxMerge or CartoSound) (n=3), were done and compared to manual manipulation guided by the integrated 3D images (CartoSound) (n=8). Each ablation was performed using contact force ranges of 10 –20 grams (20W, 17 ml/min flow, 30 seconds). Accuracy of PV ablation was assessed by comparing distance from the PV ostia (specific 4 sites) to the ablative points on the 3D image structures, and the corresponding distances of the actual ablative lesions at pathologic exam. Results: Using three integrated 3D image systems, circumferential PV ablation was successfully guided in 6 PVs (3 RSPVs and 3 LSPVs) with the robotic system. During all ablations with contact forces of 10 –20 grams, no impedance rises, pops or type 2 microbubbles were seen. Accuracy of the PV ablation was 0.22±0.84 mm (range 0 –2). The PV rings were 100% circumferential by electroanatomic mapping, yielding an 86±7% (range 80 –98%) uninterrupted circumferential ablative ring around each PV with 1.1 ± 0.4 gaps (3.0 ± 0.9 mm). These resulting parameters were equal to those in the integrated 3D image-based manual navigation (Accuracy: 0.5±0.9 (range 0 –2.5) mm, Gaps:1.3 ± 0.9 ( 2.6 ± 0.9 mm), circumferential lesions 88 ± 10% (range 70 –100). Conclusions: This feasibility study demonstrated successful integrated 3D image and contact force-guided robotic ablation. Contact sensor guided 3D volume construction and real time 3D images accurately replicated atrial and venous anatomy, resulting in successful circumferential ablation.