Plasma levels of an N‐terminal tau fragment predict core AD and neurodegenerative biomarkers in autosomal dominant Alzheimer’s disease: Findings from DIAN
AbstractBackgroundBlood based biomarkers that predict cognitive decline and Alzheimer’s disease (AD) pathology have the potential to accelerate AD therapeutic development and improve clinical care. Prior work suggests that plasma biomarkers of tau pathology (particularly post‐translational modifications of tau) may be highly useful in diagnosis and risk stratification for AD‐related neurodegeneration and cognitive decline. Levels of tau species lacking truncation of the N‐terminal region, particularly plasma and cerebrospinal fluid (CSF) levels of N‐terminal tau fragment 1 (NT1), have previously been shown to predict cognitive decline, neurodegeneration, and tau pathology in preclinical and symptomatic late‐onset AD. Here we examined plasma NT1 as a possible predictor of cognitive, clinical, pathologic, and neurodegenerative trajectories in autosomal dominant AD (ADAD) using data from the Dominantly Inherited Alzheimer Network Observational Study (DIAN‐Obs).MethodsAssociations between plasma NT1 levels and Mini‐Mental State Exam (MMSE), Clinical Dementia Rating SumBox® (CDR‐SB), hippocampal volume (HV), estimated years to symptom onset (EYO), Pittsburgh‐Compound‐B PET, and CSF Aβ42, and p‐tau181 were assessed using linear regression (150 pathogenic variant carriers, 81 non‐carriers; mean[SD] carrier age = 40.1 [10.4] years and EYO = ‐5.4 [10.4]). Plasma NT1 was measured using the Quanterix HD‐X platform. PET, MRI, clinical, and biofluid measures were derived using previously described procedures in DIAN‐Obs.ResultsCross‐sectional plasma NT1 levels in ADAD carriers were significantly associated with MMSE, CDR‐SB, HV, and p‐tau181 even after adjusting for EYO (Table 1; Figure 1). NT1 levels statistically diverged between carriers and non‐carriers 6.8 years before estimated symptom onset (Figure 2). In contrast, plasma NT1 levels were not significantly correlated with measures of β‐amyloid pathology after adjusting for EYO.ConclusionPlasma NT1 levels mirrored changes in clinical, cognitive, and neurodegenerative measures in ADAD, particularly in late asymptomatic and early symptomatic phases of disease. NT1 levels correlated with CSF measures of tau pathology, but NT1 levels were not strongly associated with CSF or PET measures of β‐amyloid pathology, unlike some previously‐studied plasma tau measures. Together with previous supportive findings in preclinical and symptomatic sporadic AD, these results suggest that plasma NT1 may be a useful biomarker of AD‐related tau pathology and neurodegeneration across a broad spectrum of disease.
A new flortaucipir PET biomarker based on graph theory for early detection of CTE in former American football players
AbstractBackgroundChronic traumatic encephalopathy (CTE) is a neurodegenerative disease that is characterized by perivascular foci of phosphorylated tau (p‐tau) notably in the depths of sulci, with varying patterns in the cerebral cortex. Prior studies show elevated flortaucipir (FTP) PET binding in former American professional football players(PRO). However, the association of p‐tau with clinical measures remains unclear using regional FTP SUVR as early signs of CTE related tau pathology. Graph theory (GT) takes advantages of the spatial variability in p‐tau load and allows the integration of regional measures to define GT based measures. Here we examine the GT based measures in two CTE cohorts to evaluate their utility in assessing p‐tau related pathology in CTE.MethodThe graph procedure was optimized in FTP PET images in a group of 26 PRO with reported cognitive and/or behavorial symptoms and 30 asymptomatic controls without a history of traumatic brain injury (the DETECT Study) and identified the GT measure, entorhinal tau strength, as the target metric with the best group separation between PRO and controls. The optimized graph procedures were then applied to the DIAGNOSE CTE Research Project dataset (99 former PRO, 51 former college football players [COL], and 52 controls without exposure to repetitive head impacts [CTL]) and we examined entorhinal tau strength’s ability to differentiate the exposure groups and relationship to consensus based diagnoses of Traumatic Encephalopathy Syndrome (TES), the clinical syndrome associated with CTE.ResultEntorhinal tau strength was significantly different among the three exposure groups (p=0.0001) similar to regional SUVR measures (Figure 1). Regional SUVR did not differentiate players (PRO+COL) with and without TES, while entorhinal tau strength approached although did not reach significance (Figure 2). Entorhinal tau strength is the only FTP measure that showed significant differences (p=0.006) between those players with cognitive impairment and players without (Figure 3).ConclusionWhile there is still considerable overlap in between‐group measurements, GT based entorhinal tau strength, is potentially more sensitive in detecting tau changes in players with and without TES. Additional studies are necessary to clarify the value of this new measure in detecting underlying CTE pathology.
Progressive white matter injury in autosomal dominant Alzheimer’s disease is strongly associated with cerebral microbleeds and neurodegeneration
AbstractBackgroundWhite matter (WM) injury visible on MRI is a common finding in Alzheimer’s disease (AD) and is often attributed to small vessel ischemic changes secondary to increased systemic vascular risk. Increased WM injury has been associated with the progression of Autosomal Dominant AD (ADAD), though ADAD pathogenic variant carriers are relatively young and may not have elevated vascular risk factors. We hypothesized that WM injury in ADAD may reflect worsening of cerebral amyloid angiopathy (CAA) and neurodegeneration. Here we examine this hypothesis using cross‐sectional and longitudinal data from the Dominantly Inherited Alzheimer Network observational study (DIAN).MethodMRI data from ADAD pathogenic variant carriers (n=223) and non‐carriers (n=136) were used in the present study (Table 1). We extracted FreeSurfer‐based WM lesion (WML) volume from T1‐weighted images (hypointensities). Cortical microbleed (CMB) burden was assessed visually on susceptibility weighted/T2*‐weighted gradient echo images by experienced radiologists (blineded to the mutation status) at the Mayo Clinic in Rochester. Linear regression models compared WML volume at baseline in people with and without CMB. Linear mixed effect models assessed the relationships between longitudinal WML and both CMBs and FreeSurfer‐based total gray matter (GM) volume. Models were corrected for age and estimated years to symptom onset (EYO).ResultGreater baseline WML volume was seen in ADAD carriers vs. non‐carriers, particularly close to the age of estimated symptom onset. Baseline WML volume was greater in carriers with CMBs compared to those without (t=2.9, p=0.003, Figure 1). Longitudinal increase in WML amongst ADAD pathogenic variant carriers with CMBs was estimated to be 214 mm3/year greater than that amongst carriers without CMBs (t=4.1, p<0.001, Figure 2). Independent of this CMB effect, decreasing GM volume was strongly associated with increasing longitudinal WML volume (t=‐6.2, p<0.001, Figure 3). Similar analyses in the non‐carrier group yielded no significant findings.ConclusionConsistent with prior reports, WML volume was increased in ADAD pathogenic variant carriers. However, the results here suggest WML in ADAD may not solely be due to small vessel ischemic changes, but rather may be a result of worsening CAA and more rapid neurodegeneration.
A standardized protocol for detection of Amyloid Related Imaging Abnormality (ARIA) on 3T Philips Magnetic Resonance Imaging (MRI)
AbstractBackgroundARIA is a common side effect of aducanumab, the first anti‐amyloid pharmacotherapy approved by the US Food and Drug Administration (FDA) to treat Alzheimer’s disease. Regular MRI is required by FDA to detect and monitor different forms of ARIA during initiation of therapy. MRI protocols must be a) high resolution to detect abnormalities with high sensitivity, b) fast to accommodate workflow and ensure patient compliance and c) standardized to maximize data acquisition consistency across sites. Based on a vendor agnostic protocol recommendation by Benzinger et al (CTAD 2021), we propose specific parameters for 3T Philips systems, for an accelerated and enhanced protocol.MethodThe protocol was developed on a 3T Philips Elition X scanner, using 32‐channel head coil, and included 3D T1, 3D FLAIR, 2D DWI, 2D T2* and multi echo 3D Susceptibility Weighted Imaging (SWI) sequences.ResultAcquisition voxel resolution of 3D T1, 3D FLAIR, T2* and DWI matches current recommendations. 3D SWI resolution is 0.7x0.7x2mm. Compressed‐SENSE (C‐SENSE) acceleration is applied on 3D T1, 3D FLAIR, T2* and 3D SWI. SENSE is applied on DWI (Figure 1). Total acquisition time including the additional 3D SWI scan is 11 minutes, 6 minutes faster than the original recommendation. Qualitative assessment of images showed high signal‐to‐noise and contrast‐to‐noise. Images were free of acceleration related artifacts. Automated slice prescription localizer ensures better reproducibility for longitudinal assessment.ConclusionImaging protocol standardization is necessary to ensure consistent accuracy for diagnosing ARIA. Broad recommendations leave room for variability, therefore specific parameters are needed to achieve cross‐platform standardization. Our protocol is applicable for 3T Philips systems with compressed‐SENSE capability and 32‐channel head coil. The recommended C‐SENSE values maintain image quality with shorter exam time. This is more comfortable for patients and easier to fit into the workflow. The higher sensitivity of SWI can improve thresholds for therapy monitoring and provide additional quantitative measurements.
Using Community Engagement Studios to Increase Recruitment and Retention of Under‐Resourced Participants in Aging Research
AbstractBackgroundAs the population ages in the United States, the prevalence of many diseases like Alzheimer disease, related dementias, and Parkinson disease disproportionately affect those already at greatest risk for premature morbidity and mortality. Aging research has an opportunity to engage and support patients, communities, and caregivers most impacted by these diseases. However, under‐resourced communities frequently lack representation in research, causing decreased generalizability of study results and health inequities among these communities.MethodsUsing a community and patient engaged framework, we conducted three community engagement studios (studios) with caregivers, patients, providers, researchers, and advocates from the St. Louis community. The studios provide community input and recommendations on project feasibility, design, and cultural appropriateness. Proposed projects were presented during each studio, followed by a facilitated discussion with a neutral facilitator. Themes were derived using traditional qualitative content analysis.ResultsStakeholders included under‐resourced community members, LGBTQIA+ participants, and those without/inadequate health insurance. The main themes included participant commitment to health, culturally appropriate research design, and incentives. In addition, participants desired collaboration between researchers and the community, including connecting with local Alzheimer’s Disease Associations, faith‐based groups, and philanthropic organizations.ConclusionOur community stakeholders provided feedback on how we could modify the research design to increase community involvement, enhance participant recruitment and commitment, and reach populations currently underrepresented in aging research, especially Alzheimer’s disease. The early inclusion of stakeholders in research design and implementation constitutes a preliminary step to building trust within under‐resourced communities and increasing the recruitment and retention of diverse populations.
AD‐causing variants that affect PSEN1 transmembrane domains are associated with faster neurodegeneration and cognitive decline compared to those affecting cytoplasmic domains
AbstractBackgroundRates of cognitive and biomarker change in Autosomal Dominant Alzheimer disease (ADAD) vary substantially across individuals. Prior cross‐sectional work suggests that the location of the pathogenic variant within PSEN1, specifically whether the underlying variant affects transmembrane (TM) or cytoplasmic (CY) domains in PSEN1, may be a key determinant in these differential rates of progression. Here we use longitudinal data from the Dominantly Inherited Alzheimer Network observational study (DIAN‐Obs) to examine whether variants affecting TM versus CY domains in PSEN1 have differential rates of change in key cognitive and neurodegenerative markers, and whether these differences are relevant to ADAD clinical trials.MethodsUsing longitudinal clinical, cognitive, and MRI data from PSEN1 pathogenic variant carriers [TM group N=76 and CY group N=44; Table 1], we assessed rates of change in Mini‐Mental State Exam (MMSE), Clinical Dementia Rating® Sum of Boxes (CDR®‐SOB), and hippocampal volume (HV) using linear mixed effects models accounting for disease stage (estimated years to symptom onset [EYO]). We further assessed how PSEN1 mutation location (TM versus CY) impacts sample size and detectable effect size in a potential ADAD clinical trial (modeled as a 4‐year trial with annual assessments; 80% power; α = 0.05).ResultsPSEN1 TM and PSEN1 CY groups did not differ on baseline age, EYO, or CDR®. The PSEN1 TM group had significantly greater rates of change on MMSE (B[SE] = ‐0.42[0.1], p=0.002), CDR®‐SOB (B[SE] = 0.23[0.1], p=0.001), and HV atrophy (B[SE] = ‐58.93[14.3], p=0.0006 compared to the PSEN1 CY group (Fig.1). Consistent with these differential rates of change, power analyses indicated the required sample size to detect a 30% treatment effect on MMSE or HV would be reduced by 59.6% for MMSE and 91.0% for HV for a trial population comprised of PSEN1 TM versus CY carriers (Fig.2).ConclusionsIndividuals who had a variant affecting the transmembrane domains of PSEN1 had greater rates of cognitive decline and neurodegeneration compared to those with variants affecting cytoplasmic domains. In addition to having implications for ADAD pathophysiology, these results suggest that incorporating information regarding the location of PSEN1 variants may be beneficial in analyzing and designing stratification approaches for ADAD trials.
AD‐causing variants that affect PSEN1 transmembrane domains are associated with faster neurodegeneration and cognitive decline compared to those affecting cytoplasmic domains.
AbstractBackgroundRates of cognitive and biomarker change in Autosomal Dominant Alzheimer disease (ADAD) vary substantially across individuals. Prior cross‐sectional work suggests that the location of the pathogenic variant within PSEN1, specifically whether the underlying variant affects transmembrane (TM) or cytoplasmic (CY) domains in PSEN1, may be a key determinant in these differential rates of progression. Here we use longitudinal data from the Dominantly Inherited Alzheimer Network observational study (DIAN‐Obs) to examine whether variants affecting TM versus CY domains in PSEN1 have differential rates of change in key cognitive and neurodegenerative markers, and whether these differences are relevant to ADAD clinical trials.MethodsUsing longitudinal clinical, cognitive, and MRI data from PSEN1 pathogenic variant carriers [TM group N=76 and CY group N=44; Table 1], we assessed rates of change in Mini‐Mental State Exam (MMSE), Clinical Dementia Rating® Sum of Boxes (CDR®‐SOB), and hippocampal volume (HV) using linear mixed effects models accounting for disease stage (estimated years to symptom onset [EYO]). We further assessed how PSEN1 mutation location (TM versus CY) impacts sample size and detectable effect size in a potential ADAD clinical trial (modeled as a 4‐year trial with annual assessments; 80% power; α = 0.05).Results PSEN1 TM and PSEN1 CY groups did not differ on baseline age, EYO, or CDR®. The PSEN1 TM group had significantly greater rates of change on MMSE (B[SE] = ‐0.42[0.1], p=0.002), CDR®‐SOB (B[SE] = 0.23[0.1], p=0.001), and HV atrophy (B[SE] = ‐58.93[14.3], p=0.0006 compared to the PSEN1 CY group (Fig.1). Consistent with these differential rates of change, power analyses indicated the required sample size to detect a 30% treatment effect on MMSE or HV would be reduced by 59.6% for MMSE and 91.0% for HV for a trial population comprised of PSEN1 TM versus CY carriers (Fig.2).ConclusionsIndividuals who had a variant affecting the transmembrane domains of PSEN1 had greater rates of cognitive decline and neurodegeneration compared to those with variants affecting cytoplasmic domains. In addition to having implications for ADAD pathophysiology, these results suggest that incorporating information regarding the location of PSEN1 variants may be beneficial in analyzing and designing stratification approaches for ADAD trials.
A standardized protocol for detection of Amyloid Related Imaging Abnormality (ARIA) on 3T Philips Magnetic Resonance Imaging (MRI)
AbstractBackgroundARIA is a common side effect of aducanumab, the first anti‐amyloid pharmacotherapy approved by the US Food and Drug Administration (FDA) to treat Alzheimer’s disease. Regular MRI is required by FDA to detect and monitor different forms of ARIA during initiation of therapy. MRI protocols must be a) high resolution to detect abnormalities with high sensitivity, b) fast to accommodate workflow and ensure patient compliance and c) standardized to maximize data acquisition consistency across sites. Based on a vendor agnostic protocol recommendation by Benzinger et al (CTAD 2021), we propose specific parameters for 3T Philips systems, for an accelerated and enhanced protocol.MethodThe protocol was developed on a 3T Philips Elition X scanner, using 32‐channel head coil, and included 3D T1, 3D FLAIR, 2D DWI, 2D T2* and multi echo 3D Susceptibility Weighted Imaging (SWI) sequences.ResultAcquisition voxel resolution of 3D T1, 3D FLAIR, T2* and DWI matches current recommendations. 3D SWI resolution is 0.7x0.7x2mm. Compressed‐SENSE (C‐SENSE) acceleration is applied on 3D T1, 3D FLAIR, T2* and 3D SWI. SENSE is applied on DWI (Figure 1). Total acquisition time including the additional 3D SWI scan is 11 minutes, 6 minutes faster than the original recommendation. Qualitative assessment of images showed high signal‐to‐noise and contrast‐to‐noise. Images were free of acceleration related artifacts. Automated slice prescription localizer ensures better reproducibility for longitudinal assessment.ConclusionImaging protocol standardization is necessary to ensure consistent accuracy for diagnosing ARIA. Broad recommendations leave room for variability, therefore specific parameters are needed to achieve cross‐platform standardization. Our protocol is applicable for 3T Philips systems with compressed‐SENSE capability and 32‐channel head coil. The recommended C‐SENSE values maintain image quality with shorter exam time. This is more comfortable for patients and easier to fit into the workflow. The higher sensitivity of SWI can improve thresholds for therapy monitoring and provide additional quantitative measurements.
Paging the Clinical Informatics Community: Respond STAT to Dobbs v. Jackson's Women's Health Organization