Citations

Clear

16289 citation(s) found for "Yu, David".

Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Padmanabhan, Deepak , Jondal, Mary Lou, Hodge, David O. , Mehta, Ramila A. , Acker, Nancy G., Dalzell, Connie, Asirvatham, Samuel J. , Cha, Yong‐Mei , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Jondal, Mary L, Dalzell, Connie M, Kapa, Suraj , Asirvatham, Samuel J

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 | PMID 29321191 Get It

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
Tamm-Horsfall protein/uromodulin deficiency elicits tubular compensatory responses leading to hypertension and hyperuricemia
Liu, Yan, Goldfarb, David S. , Wu, Xue‐Ru , El‐Achkar, Tarek M. , Lieske, John C. , Goldfarb, David S

Mayo Clinic

American Journal of Physiology-Renal Physiology | January 10, 2018 | Volume: 314 | Issue: 6 | Pages: F1062-F1076

10.1152/ajprenal.00233.2017 | PMID 29357410 Get It

Expression of Tamm-Horsfall protein (THP or uromodulin) is highly restricted to the kidney thick ascending limb (TAL) of loop of Henle. Despite the unique location and recent association of THP gene mutations with hereditary uromodulin-associated kidney disease and THP single nucleotide polymorphisms with chronic kidney disease and hypertension, the physiological function(s) of THP and its pathological involvement remain incompletely understood. By studying age-dependent changes of THP knockout (KO) mice, we show here that young KO mice had significant salt and water wasting but were partially responsive to furosemide, due to decreased luminal translocation of Na-K-Cl cotransporter 2 (NKCC2) in the TAL. Aged THP KO mice were, however, markedly oliguric and unresponsive to furosemide, and their NKCC2 was localized primarily in the cytoplasm as evidenced by lipid raft floatation assay, cell fractionation, and confocal and immunoelectron microscopy. These aged KO mice responded to metolazone and acetazolamide, known to target distal and proximal tubules, respectively. They also had marked upregulation of renin in juxtaglomerular apparatus and serum, and they were hypertensive. Finally, the aged THP KO mice had significant upregulation of Na-coupled urate transporters Slc5a8 and Slc22a12 as well as sodium-hydrogen exchanger 3 (NHE3) in the proximal tubule and elevated serum uric acid and allantoin. Collectively, our results suggest that THP deficiency can cause progressive disturbances in renal functions via initially NKCC2 dysfunction and later compensatory responses, resulting in prolonged activation of the renin-angiotensin-aldosterone axis and hyperuricemia.
Writing Good True-False Questions: A Brief Guide for Radiologists
DiSantis, David J.

Mayo Clinic

RadioGraphics | January 10, 2018 | Volume: 38 | Issue: 1 | Pages: 107-108

10.1148/rg.2018174015 | PMID 29320321 Get It

Analysis of Brain SPECT Images Coregistered with MRI in Patients with Epilepsy: Comparison of Three Methods
Long, Zaiyang , Mullan, Brian P., Holmes, David R. , Brinkmann, Benjamin H. , O’Connor, Michael K. , Hanson, Dennis P. , Hunt, Christopher H. , O'Connor, Michael K, Brinkmann, Benjamin H

Mayo Clinic

Journal of Neuroimaging | January 10, 2018 | Volume: 28 | Issue: 3 | Pages: 307-312

10.1111/jon.12496 | PMID 29319202 Get It

ABSTRACT BACKGROUND AND PURPOSE SISCOM and STATISCOM were clinically proved to be effective for ictal/inter‐ictal single‐photon emission computed tomography (SPECT) analysis coregistered with magnetic resonance imaging (MRI) for seizure localization. Recently, a software package also became available for this analysis. This study aimed to investigate and compare the performance of these analysis methods for seizure localization. METHODS A total of 378 patients who underwent 99m Tc‐ethyl cysteinate dimer (ECD) SPECT scans were retrospectively reviewed and 28 remained after applying exclusion criteria. Their SPECT and MRI images were analyzed with SISCOM (with z ‐score of 1.5 and 2), STATISCOM, and MIMneuro, resulting in a total of 112 image data sets. Two experienced radiologists participated in the blind review process using a custom tool and they can mark up to two hyper‐ and/or hypoperfusion regions. Their review results were analyzed using the Jackknife Free Response Receiver‐Operating Characteristics (JAFROC) test and the JAFROC figure‐of‐merit (FoM) was reported for each method. The interobserver agreement was also assessed using Cohen's kappa test. RESULTS Based on the readers’ two choices, averaged FoM was 85.7%, 83.9%, 66.1%, and 51.8% for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. The average confidence rating was 2.5, 2.3, 1.6, and 1.1 for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. For interobserver agreement, kappa was .742 for STATISCOM, .816 for MIMneuro, .517 for SISCOM ( z ‐score = 2), and .441 for SISCOM ( z ‐score = 1.5; all P < .001). CONCLUSION Our study demonstrated that STATISCOM showed the best performance for seizure localization, which was closely followed by MIMneuro. In addition, MIMneuro was not inferior to SISCOM with either z ‐score.
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Ryan, J. , Tempel, Nathan D., Engle, Dean D., Hayes, David L. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Ryan, James D , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | January 10, 2018 | Volume: 41 | Issue: 2 | Pages: 161-166

10.1111/pace.13269 | PMID 29315719 Get It

AbstractBackgroundTransthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.ObjectiveWe report an increased incidence of TIM oversensing.MethodRetrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.ResultsWe have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.ConclusionOversensing with pacing inhibition is apparent with the potential of adverse effects to patients.
A quality improvement project aimed at adapting primary care to ensure the delivery of evidence-based psychotherapy for adult anxiety
Williams, Mark D. , Sawchuk, Craig N. , Shippee, Nathan D. , Somers, Kristin J., Berg, Summer L., Mitchell, Jay D. , Mattson, Angela, Katzelnick, David J., Mattson, Angela B, Shippee, Nathan

Mayo Clinic

BMJ Open Quality | January 9, 2018 | Volume: 7 | Issue: 1 | Pages: e000066

10.1136/bmjoq-2017-000066 | PMID 29333493 Get It

Primary care patients frequently present with anxiety with prevalence ratios up to 30%. Brief cognitive–behavioural therapy (CBT) has been shown in meta-analytic studies to have a strong effect size in the treatment of anxiety. However, in surveys of anxious primary care patients, nearly 80% indicated that they had not received CBT. In 2010, a model of CBT (Coordinated Anxiety Learning and Management (CALM)) adapted to primary care for adult anxiety was published based on results of a randomised controlled trial. This project aimed to integrate an adaptation of CALM into one primary care practice, using results from the published research as a benchmark with the secondary intent to spread a successful model to other practices. A quality improvement approach was used to translate the CALM model of CBT for anxiety into one primary care clinic. Plan-Do-Study-Act steps are highlighted as important steps towards our goal of comparing our outcomes with benchmarks from original research. Patients with anxiety as measured by a score of 10 or higher on the Generalized Anxiety Disorder 7 item scale (GAD-7) were offered CBT as delivered by licensed social workers with support by a PhD psychologist. Outcomes were tracked and entered into an electronic registry, which became a critical tool upon which to adapt and improve our delivery of psychotherapy to our patient population. Challenges and adaptations to the model are discussed. Our 6-month response rates on the GAD-7 were 51%, which was comparable with that of the original research (57%). Quality improvement methods were critical in discovering which adaptations were needed before spread. Among these, embedding a process of measurement and data entry and ongoing feedback to patients and therapists using this data are critical step towards sustaining and improving the delivery of CBT in primary care.
Expanding the Scope of Research Ethics Consultation Services in Safeguarding Research Integrity: Moving Beyond the Ethics of Human Subjects Research
Martinson, Brian C. , Resnik, David B. , Martinson, Brian C , Master, Zubin

Mayo Clinic

The American Journal of Bioethics | January 9, 2018 | Volume: 18 | Issue: 1 | Pages: 55-57

10.1080/15265161.2017.1401167 | PMID 29313786 Get It

Multi-target stool DNA test in the surveillance of inflammatory bowel disease: a cross-sectional cohort study
Klepp, Pasquale , Småstuen, Milada Cvancarova, Røseth, Arne, Andersen, Solveig Norheim, Vatn, Morten H., Ahlquist, David A. , Brackmann, Stephan , Kisiel, John B. , Moum, Bjørn Allan

Mayo Clinic

Scandinavian Journal of Gastroenterology | January 9, 2018 | Volume: 53 | Issue: 3 | Pages: 273-278

10.1080/00365521.2018.1424935 | PMID 29313389 Get It

Up-and-Over Technique for Implantation of Iliac Branch Devices After Prior Aortic Endograft Repair
Dawson, David L. , Sandri, Giuliano de Almeida, Tenorio, Emanuel R. , Tenorio, Emanuel, Tenorio, Emanuel R , Sandri, Giuliano A., Oderich, Gustavo S.

Mayo Clinic

Journal of Endovascular Therapy | January 9, 2018 | Volume: 25 | Issue: 1 | Pages: 21-27

10.1177/1526602817747283 | PMID 29313456 Get It

Purpose: To describe a modified up-and-over access technique for treatment of iliac artery aneurysms in patients with prior bifurcated stent-grafts for endovascular aneurysm repair (EVAR). Technique: This technique uses a coaxial 12-F flexible sheath that is docked with a through-and-through wire into a 7-F sheath advanced from the contralateral femoral approach. This maneuver allows both sheaths to be moved as a unit while maintaining position of the apex of the system as it loops over the flow divider, avoiding damage to or displacing the extant endograft. Once the 12-F sheath is positioned in the iliac limb of the aortic stent-graft and secured in place with the through-and-through wire, the repair is extended into the internal iliac artery using a bridging stent-graft or covered stent introduced via a coaxial sheath. Conclusion: The up-and-over technique with a flexible 12-F sheath mated with a 7-F sheath from the opposite side allows bilateral femoral access to be used for iliac branch device placement after prior aortic endograft procedures that create a higher, acutely angled bifurcation. Use of a through-and-through wire and a coaxial sheath for stent delivery creates a very stable platform for intervention.
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

Mayo Clinic

EP Europace | January 5, 2018 | Volume: 20 | Issue: 1 | Pages: 157-208

10.1093/europace/eux275 | PMID 29016841 Get It