Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
Histological grades and prognostic markers of well-differentiated pancreatic neuroendocrine tumor (WDPNET)
Abstract Pancreatic neuroendocrine tumors (PNETs) are the second most common neoplasm of the pancreas after ductal adenocarcinoma. The clinical behavior of PNETs is very difficult to predict, especially for well-differentiated PNETs. Several classification systems have been developed to differentiate benign from malignant PNETs. The current 5th edition WHO (2019) updated the grading system of PNETs which is now entirely based on proliferative rate (either mitotic count or Ki-67 index). In this article, we systemically reviewed the evolution of the histologic classification and grading systems for well-differentiated PNETs. Meanwhile, we also report a comprehensive summary of immunohistochemical and molecular prognostic factors for PNETs patients, including CK19, KIT, PD-L1/PD-L1, UCH-L1 and CNPY2. We believe that more reliable grading systems and prognostic markers are emerging and will change the landscape of treatment for well-differentiated PNETs.
Effect of intensive versus standard blood pressure control on cerebral blood flow in SPRINT
AbstractBackgroundHypertension is a major risk factor for cardiovascular and cerebrovascular disease including stroke, small vessel disease, and dementia. The Systolic blood PRessure INTervention (SPRINT) randomized trial prospectively evaluated the effects of intensive systolic blood pressure (SBP) control (target SBP<120mmHg) versus standard control (SBP<140mmHg) on cardiovascular outcomes in individuals without baseline diabetes or stroke, and included cerebral blood flow (CBF) measurements. Previous studies with much smaller sample sizes and shorter duration suggested stable CBF in response to intensive treatment (SBP<125mmHg) [1], but long term effects are unknown. We evaluated the long‐term effects of intensive blood pressure treatment on CBF.MethodWhole brain CBF was measured at 3T using pseudocontinuous arterial spin labeled (ASL) perfusion MRI at baseline and after 3.9±0.3 years. Total white matter lesion (WML) load was measured from Fluid Attenuated Inversion Recovery T2 MRI. Data from 324 subjects with adequate ASL scan quality acquired from 6 sites were included.ResultDemographics and scanner specific CBF values are provided in Table 1. The intensive treatment group was older (p=0.01), but was otherwise similar to the standard group at baseline. There was a significant effect on the longitudinal CBF change (p=0.006) of the intensive treatment (5.7% increase) compared to the standard treatment (4.0% decrease, Fig 1). Secondary analysis showed a significant increase in age‐adjusted fractional CBF for the intensive treatment group (p<0.001) with no change (p=0.24) in the standard treatment group. Change in CBF was not associated with change in WML.ConclusionSustained intensive antihypertensive treatment does not reduce whole brain CBF, in fact it showed an increase in whole brain CBF relative to standard therapy. While improved CBF might contribute to the reduced WML progression observed in the intensive‐therapy group versus standard therapy in SPRINT[2], we did not observe a direct correlation between CBF changes and WML changes. References: (1) Croall et al. JAMA‐Neurol,2018; (2) Nasrallah et al., JAMA‐Neurol, 2019.
Avoidable Acute Care Use Associated with Nausea and Vomiting Among Patients Receiving Highly Emetogenic Chemotherapy or Oxaliplatin
Abstract Purpose Chemotherapy-induced nausea and vomiting (CINV) contributes to avoidable acute care, a metric now tracked in Medicare's oncology outcome measure. CINV is preventable, yet guidelines are often not followed. We sought to quantify acute care involving CINV and other avoidable toxicities after highly emetogenic chemotherapy (HEC) to identify excess risk and assess clinician adherence to antiemesis guidelines for HEC. Materials and Methods We retrospectively evaluated U.S. electronic health records (2012-2018) using Medicare's OP-35 outcome measure to identify avoidable acute care involving any of 10 toxicities, including CINV, after HEC regimens relative to non-HEC. Antiemetic guideline adherence was defined as use ofneurokinin-1 (NKl) receptor antagonists Q5 (RAs) plus 5-hydroxytryptamine type 3 RA+ dexamethasone at HEC initiation. Results Among 17,609 patients receiving HEC, acute care rates associated with HEC chemotherapy included 32% cisplatin, 31% carboplatin, and 21% anthracycline/cyclosphospharnide (AC), with 76% meeting the criteria as avoidable events. Oxaliplatin rates were 29%. Avoidable acute care occurred 1.83 times (95% confidence interval, 1.76-1.91, p < .0001) as often after HEC versus non-HEC excluding oxaliplatin; CINV-related acute care occurred 2.29 times as often. Nonadherence to antiemesis guidelines occurred in 34% and 24% of cisplatin and AC courses, respectively, because of omission of a NKl RA. Conclusions Patients treated with HEC regimens experienced high avoidable acute care use, 1.8 times the risk seen for other chemotherapy. Nonadherence to guideline-directed antiemetic prophylaxis highlights the need to ensure adherence to antiemetic guidelines, including the use of NKl RA in HEC. Implications for Practice After survival, perhaps the most important goal in oncology is limiting avoidable acute care, a goal now used by Medicare to impact cancer reimbursement. This study found that patients treated with highly emetogenic chemotherapy (HEC) regimens had high rates of avoidable acute care use, 1.8 times the risk seen for other chemotherapy. A substantial proportion of the avoidable acute care involved chemotherapy-induced nausea and vomiting. Results showed that incomplete adherence to national antiemetic guidelines for HEC regimens primarily driven by omission of upfront neurokinin-1 receptor antagonist use, suggesting that improved adherence can meaningfully resolve this gap in quality and cost of care.
Evaluation of Concordance Between Original Death Certifications and an Expert Panel Process in the Determination of Sudden Unexplained Death in Childhood
Vascular contributions to cognitive impairment and dementia (VCID): A report from the 2018 National Heart, Lung, and Blood Institute and National Institute of Neurological Disorders and Stroke Workshop
Abstract Vascular contributions to cognitive impairment and dementia (VCID) are characterized by the aging neurovascular unit being confronted with and failing to cope with biological insults due to systemic and cerebral vascular disease, proteinopathy including Alzheimer's biology, metabolic disease, or immune response, resulting in cognitive decline. This report summarizes the discussion and recommendations from a working group convened by the National Heart, Lung, and Blood Institute and the National Institute of Neurological Disorders and Stroke to evaluate the state of the field in VCID research, identify research priorities, and foster collaborations. As discussed in this report, advances in understanding the biological mechanisms of VCID across the wide spectrum of pathologies, chronic systemic comorbidities, and other risk factors may lead to potential prevention and new treatment strategies to decrease the burden of dementia. Better understanding of the social determinants of health that affect risks for both vascular disease and VCID could provide insight into strategies to reduce racial and ethnic disparities in VCID.
CT for Pre- and Postprocedural Evaluation of Transcatheter Mitral Valve Replacement