Temporal Occurrence of Arrhythmic Complications After Alcohol Septal Ablation
El‐Sabawi, Bassim , Barsness, Gregory W. , Cha, Yong‐Mei , Geske, Jeffrey B. , Eleid, Mackram F. , Geske, Jeffrey B , Nishimura, Rick A.

Mayo Clinic

Circulation: Cardiovascular Interventions | January 24, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circinterventions.119.008540 | PMID 31973555 Get It

Background: The temporal occurrence of arrhythmic complications after alcohol septal ablation (ASA) is unclear. As a result, the appropriate time to monitor patients after ASA is controversial. The purpose of this study is to determine the temporal occurrence of complete heart block (CHB) and ventricular tachyarrhythmia (VT) after ASA to better understand when patients can be safely discharged. Methods: Consecutive patients treated with ASA for hypertrophic cardiomyopathy from 2003 to 2019 at a tertiary referral center were reviewed retrospectively. The incidence and timing of CHB or sustained VT within 30 days post-ASA were assessed. Results: A total of 243 patients were included in this study. Mean maximal septal thickness was 19.0±3.9 mm, and total volume of ethanol injected was 1.7±0.6 mL. CHB occurred in 59 (24.3%) patients, including transient CHB in 33 (13.6%) and permanent in 26 (10.7%). The initial episode of CHB occurred within 24 hours post-ASA in 51 (21.0%) patients, between 24 and 48 hours in 3 (1.2%), between 48 and 72 hours in 3 (1.2%), and after 72 hours in 2 (0.8%). New permanent pacemaker was placed in 46 (18.3%). Presence of baseline bundle branch block and age ≥70 were significantly associated with CHB but not CHB presenting after 24 hours. VT occurred in 3 (1.2%) patients, including 1 (0.4%) within 24 hours, 1 (0.4%) between 24 and 48 hours, and 1 (0.4%) after 72 hours. VT required cardioversion in 2 patients and new implantable cardioverter-defibrillator placement in 2. Conclusions: The incidence of CHB or VT presenting after 72 hours post-ASA was low. These findings suggest that timely discharge of patients without evidence of early conduction disturbances after ASA can be considered as a potentially safe management strategy, especially in patients without preexisting conduction abnormalities.
Utility of 30-Day Continuous Ambulatory Monitoring to Identify Patients With Delayed Occurrence of Atrioventricular Block After Transcatheter Aortic Valve Replacement
Tian, Ying , Padmanabhan, Deepak , Xiao, Peilin, Sandhu, Gurpreet S. , Greason, Kevin L. , Gulati, Rajiv , Rihal, Charanjit S. , Polk, Lynn, Sanvick, Carrie, Liu, Xing-Peng , Friedman, Paul A. , Cha, Yong‐Mei , Polk, Lynn E, McLeod, Christopher J. , Zhang, Pei , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Sanvick, Carrie

Mayo Clinic

Circulation: Cardiovascular Interventions | December 13, 2019 | Volume: 12 | Issue: 12 | Pages: No page available

10.1161/circinterventions.118.007635 | PMID 31833417 Get It

Background: Mechanical injury in the conduction system requiring permanent pacemaker (PPM) associated with transcatheter aortic valve replacement (TAVR) procedure is a common complication. The objective of this study was to use ambulatory monitor BodyGuardian to assess late occurrence of atrioventricular block (AVB) after TAVR. Methods: This prospective study evaluated 365 patients who underwent TAVR at Mayo Clinic, Rochester, Minnesota between June 2016 and August 2017. Patients who received PPM for bradycardia after TAVR before discharge were considered as the PPM group. Those not requiring PPM received a BodyGuardian system (BodyGuardian group) for 30 days of continuous monitoring. Primary end point was Mobitz II or third-degree atrioventricular block (II/III AVB) at 30-day follow-up. Results: Of 365 patients, 74 who had a PPM or an implantable cardioverter-defibrillator before TAVR and 94 who were enrolled in other studies were excluded. Of 197 patients enrolled in the study, 70 (35.5%) received PPM and 127 had BodyGuardian before the hospital dismissal. Eleven of 127 (8.6%) BodyGuardian group required PPM within 30 days after TAVR for late occurrence of symptomatic bradycardia. In total, 33 of 197 (16.7%) patients developed II/III AVB (24 before and 9 after discharge). Thirty-four patients had preexisting right bundle branch block. Of them, 16 (47%) developed II/III AVB. Of 53 patients who developed new left bundle branch block after TAVR, 14% progressed to II/III AVB within 30 days. Conclusions: In patients without a standard post-TAVR pacing indication, yet a potential risk to develop AVB, a strategy of 30-day monitoring identifies additional patients who require permanent pacing.
Analysis of Temporal Trends and Variation in the Use of Defibrillation Testing in Contemporary Practice
Borne, Ryan T. , Randolph, Tiffany C., Wang, Yongfei , Curtis, Jeptha P. , Peterson, Pamela N., Masoudi, Frederick A. , Sandhu, Amneet , Zipse, Matthew M. , Thomas, Kevin L. , Kutyifa, V., Cha, Yong‐Mei , Hsu, Jonathan C. , Russo, Andrea M. , Hsu, Jonathan C , Peterson, Pamela N. , Desai, Nihar R.

Mayo Clinic

JAMA Network Open | October 18, 2019 | Volume: 2 | Issue: 10 | Pages: e1913553

10.1001/jamanetworkopen.2019.13553 | PMID 31626314 Get It

Stellate ganglion block and cardiac sympathetic denervation in patients with inappropriate sinus tachycardia
Cha, Yong‐Mei , Li, Xuping , Yang, Mei , Han, Jie , Wu, Gang , Noseworthy, Peter A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , Brady, Peter A. , Rho, Richard H., Friedman, Paul A. , Lee, Hon‐Chi, Tian, Ying , Zhou, Shenghua , Munger, Thomas M. , Ackerman, Michael J. , Shen, Win‐Kuang , Kapa, Suraj , Noseworthy, Peter A , Mulpuru, Siva K , Asirvatham, Samuel J , Friedman, Paul A , Zhou, Shenghua , Kapa, Suraj , McLeod, Christopher J. , Zhou, Shenghua

Mayo Clinic

Journal of Cardiovascular Electrophysiology | October 18, 2019 | Volume: 30 | Issue: 12 | Pages: 2920-2928

10.1111/jce.14233 | PMID 31625219 Get It

AbstractBackgroundInappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy.ObjectiveTo study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST.MethodsTwelve consecutive patients who had drug‐refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD.ResultsThe mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement.ConclusionSG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.
Contemporary Management of Antiplatelet and Anticoagulation for Cardiac Implantable Device Procedures
Cha, Yong‐Mei , DeSimone, Christopher V. , DeSimone, Daniel C.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | October 15, 2019 | Volume: 12 | Issue: 10 | Pages: No page available

10.1161/circep.119.007863 | PMID 31610719 Get It

Effective Use of Percutaneous Stellate Ganglion Blockade in Patients With Electrical Storm
Tian, Ying , Wittwer, Erica D. , Xiao, Peilin , Mulpuru, Siva K. , Deshmukh, Abhishek , Lee, Hon-Chi, Ackerman, Michael J. , Asirvatham, Samuel J. , Munger, Thomas M. , Liu, Xing-Peng , Friedman, Paul A. , Cha, Yong‐Mei , Asirvatham, Samuel J , Kapa, Suraj , McLeod, Christopher J. , Noseworthy, Peter A.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | September 13, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.118.007118 | PMID 31514529 Get It

Background: Percutaneous stellate ganglion blockade (SGB) has been used for drug-refractory electrical storm due to ventricular arrhythmia (VA); however, the effects and long-term outcomes have not been well studied. Methods: This study included 30 consecutive patients who had drug-refractory electrical storm and underwent percutaneous SGB between October 1, 2013, and March 31, 2018. Bupivacaine, alone or combined with lidocaine, was injected into the neck with good local anesthetic spread in the vicinity of the left stellate ganglion (n=15) or both stellate ganglia (n=15). Data were collected for patient clinical characteristics, immediate and long-term outcomes, and procedure-related complications. Results: Clinical characteristics included age, 58±14 years; men, 73.3%; and left ventricular ejection fraction, 34±16%. At 24 hours, 60% of patients were free of VA. Patients whose VA was controlled had a lower hospital mortality rate than patients whose VA continued (5.6% versus 50.0%; P =0.009). Implantable cardioverter-defibrillator interrogation showed a significant 92% reduction in VA episodes from 26±41 to 2±4 in the 72 hours after SGB ( P <0.001). Patients who died during the same hospitalization (n=7) were more likely to have ischemic cardiomyopathy (100% versus 43.5%; P =0.03) and recurrent VA within 24 hours (85.7% versus 26.1%; P =0.009). There were no procedure-related major complications. Conclusions: SGB effectively attenuated electrical storm in more than half of patients without procedure-related complications. Percutaneous SGB may be considered for stabilizing ventricular rhythm in patients for whom other therapies have failed.
Incidence and Natural History of Left Bundle Branch Block Induced Cardiomyopathy
Barake, Walid , Witt, Chance M. , Vaidya, Vaibhav R. , Cha, Yong‐Mei

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | September 12, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.119.007393 | PMID 31510788 Get It

Association between the Charlson comorbidity index and outcomes after implantable cardioverter defibrillator generator replacement
Amin, Mustapha M., Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Frey, Rebecca J., Frederick, Nicolette K., Cha, Yong‐Mei , Brenes-Salazar, Jorge A., Madhavan, Malini , Brenes-Salazar, Jorge

Mayo Clinic

Pacing and Clinical Electrophysiology | July 29, 2019 | Volume: 42 | Issue: 9 | Pages: 1236-1242

10.1111/pace.13762 | PMID 31355952 Get It

AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.
Incidence and outcomes of systemic infections in patients with leadless pacemakers: Data from the Micra IDE study
El‐Chami, Mikhael F. , Soejima, Kyoko , Piccini, Jonathan P. , Reynolds, Dwight, Ritter, Philippe , Okabe, Toshimasa , Friedman, Paul A. , Cha, Yong‐Mei , Stromberg, Kurt , Holbrook, Reece , Fagan, Dedra H. , Roberts, Paul R. , El-Chami, Mikhael F , Stromberg, Kurt

Mayo Clinic

Pacing and Clinical Electrophysiology | June 24, 2019 | Volume: 42 | Issue: 8 | Pages: 1105-1110

10.1111/pace.13752 | PMID 31232461 Get It

AbstractBackgroundThe Micra clinical trials have enrolled more than 2500 patients without any reported device‐related infections that required removal during follow‐up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation.ObjectiveTo analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow‐up in patients with history of Micra leadless pacemaker implantation.MethodsSIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow‐up.ResultsAmong patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram‐positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram‐positive bacteria), and gram‐negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow‐upConclusionIn this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.
Electrophysiologic effects and outcomes of sympatholysis in patients with recurrent ventricular arrhythmia and structural heart disease
Cai, Cheng , Dai, Mingyan , Tian, Ying , Zhang, Pei , Wittwer, Erica D. , Rho, Richard H., Mulpuru, Siva K. , Lee, Hon‐Chi, Ackerman, Michael J. , Asirvatham, Samuel J. , Munger, Thomas M. , Friedman, Paul A. , Cha, Yong‐Mei , Dai, Ming-Yan, Kapa, Suraj , Mulpuru, Siva K , Asirvatham, Samuel J , Chen, Ming-Long , Friedman, Paul A , Cha, Yong-Mei , Kapa, Suraj , McLeod, Christopher J.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 14, 2019 | Volume: 30 | Issue: 9 | Pages: 1499-1507

10.1111/jce.14030 | PMID 31199536 Get It

AbstractIntroductionAutonomic modulation has been used as a therapy to control recurrent ventricular arrhythmia (VA). This study was to explore stellate ganglion block (SGB) effect on cardiac electrophysiologic properties and evaluate the long‐term outcome of cardiac sympathetic denervation (CSD) for patients with recurrent VA and structural heart disease (SHD).Materials and MethodsPatients who had recurrent VA due to SHD were enrolled prospectively. Electrophysiologic study and ventricular tachycardia (VT) induction were performed before and after left and right SGB. VA burden and long‐term outcomes were assessed for a separate patient group who underwent left or bilateral CSD for drug‐refractory VA due to SHD.ResultsElectrophysiologic study of nine patients showed that baseline mean (SD) corrected sinus node recovery time (cSNRT) increased from 320.4 (73.3) ms to 402.9 (114.2) ms after left and 482.4 (95.7) ms after bilateral SGB (P = .03). SGB did not significantly change P‐R, QRS, and Q‐T intervals and ventricular effective refractory period, nor did the inducibility of VA. Nineteen patients underwent left (n = 14) or bilateral (n = 5) CSD. CSD reduced VA burden and appropriate ICD therapies from a median (interquartile range) of 2.5 (0.4‐11.6) episodes weekly to 0.1 (0.0‐2.4) episodes weekly at 6‐month follow‐up (P = .002). Three‐year freedom from orthotopic heart transplant (OHT) and death was 52.6%. New York Heart Association functional class III/IV and VT rate less than 160 beats per minute were predictors of recurrent VA, OHT, and death.ConclusionSGB increased cSNRT without changing heart rate. CSD was more beneficial for patients with mild‐to‐moderate heart failure and faster VA.