Citations

Clear

2939 citation(s) found for "Ryan, S".

Comparing associations of Alzheimer’s disease plasma biomarkers with remote self‐administered cognitive measures versus in‐person neuropsychological tests
Frank, Ryan D. , Fan, Winnie Z. , Christianson, Teresa J., Karstens, Aimee J. , Stricker, John L. , Fields, Julie A. , Graff‐Radford, Jonathan, Petersen, Ronald C. , Boots, Elizabeth A. , Karstens, Aimee James , Kremers, Walter K. , Machulda, Mary M. , Hassenstab, Jason , Graff‐Radford, Jonathan , Vemuri, Prashanthi , Jack, Clifford R. , Knopman, David S. , Mielke, Michelle M. , Stricker, Nikki H.

Mayo Clinic

Alzheimer's & Dementia | December 25, 2023 | Volume: 19 | Issue: S11 | Pages: No page available

10.1002/alz.082087 Get It

Abstract Background Brief self‐administered cognitive assessments deployed remotely and combined with plasma biomarkers of Alzheimer’s disease (AD) are well suited to assess clinical symptoms and underlying biology in large‐scale decentralized studies. We investigated whether associations of self‐administered cognitive measures and plasma biomarkers were comparable to associations of in‐person cognitive measures and plasma biomarkers. Method Participants included 327 adults from the Mayo Clinic Study of Aging (mean age = 70.8; 48% female; mean education = 16.0 years; 96.9% white). Most (94.5%) were cognitively unimpaired; 5.5% had consensus diagnosis of mild cognitive impairment. Participants completed Mayo Test Drive (MTD; Stricker et al., 2022), a remote, self‐administered, multi‐device compatible web‐based cognitive assessment comprised of the Stricker Learning Span (SLS) and Symbols test that are combined into a MTD composite. Participants also completed in‐person neuropsychological assessment (global‐z; Mayo Preclinical Alzheimer’s disease Cognitive Composite [Mayo‐PACC]) and fasting venipuncture. Plasma was assayed via HD‐X simoa platform for amyloid‐beta (Aß)‐42 and Aß‐40 to create an Aß42/40 ratio, glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL) using the N4PE Quanterix kit as well as phosphorylated‐tau protein 181 (p‐tau181). P‐tau181, GFAP, and NfL were log10‐transformed. Multiple regression analyses adjusting for age, sex, and education examined associations between plasma biomarkers and composite and subtest scores from remote and in‐person measures. Davidson‐Mackinnon J‐test compared R‐squared values of models with remote versus in‐person composites. Result Lower performances on MTD, global‐z, and Mayo‐PACC (Table 1) were associated with higher GFAP (p’s = .02), NfL (p’s = .003), and p‐tau181 (p’s = .04). For memory, worse SLS and AVLT sum of trials were associated with higher GFAP (p’s = .01) and NfL (p’s = .03). For processing speed/executive function, worse Symbols and Trails B were associated with higher p‐tau181 (p’s = .02). Worse Trails B and Digit Symbol Coding were associated with higher NfL (p’s = .02), and worse Digit Symbol Coding was associated with lower Aß42/40 (p = 0.03; Table 2). A multivariable model with MTD explained significantly more variance (p = .04) for NfL (adjusted R‐squared = 0.461) than a multivariable model with Mayo‐PACC (adjusted R‐squared = 0.447); remote and in‐person composite measures were comparable for other associations (p’s>.05). Conclusion Remote and in‐person composite measures showed comparable associations with AD‐related plasma biomarkers, supporting MTD’s criterion validity.
Acute effects of an isometric neck warm-up programme on neck performance characteristics and ultrasound-based morphology
Schilaty, Nathan D. , Wong, Hanwen, Keller, Valerie, Stiennon, Sean T., Chang, Ryan W.B, Schilaty, Nathan D , Keller, Valerie C, Nagai, Takashi , Stuart, Michael J. , Krause, David A.

Mayo Clinic

Annals of Medicine | December 24, 2023 | Volume: 55 | Issue: 2 | Pages: No page available

10.1080/07853890.2023.2295402 | PMID 38142049 Get It

Comparison of da Vinci Single Port vs Si Systems for Transoral Robotic-Assisted Surgery
Oberhelman, Nicholas J., Bruening, Jennifer , Abel, Kathryn M. Van , Sumer, Baran D. , Andersen, Peter E. , Li, Ryan J. , Van Abel, Kathryn M , Jackson, Ryan S. , Holsinger, F. Christopher , Chan, Jason Y. K. , Gross, Neil D , Clayburgh, Daniel

Mayo Clinic

JAMA Otolaryngology–Head & Neck Surgery | December 21, 2023 | Volume: 150 | Issue: 2 | Pages: 165

10.1001/jamaoto.2023.3994 | PMID 38127360 Get It

Importance Transoral robot-assisted surgery (TORS) continues to have a major role in the treatment of oropharyngeal cancer. As new iterations of robotic technology are increasingly utilized, it is important to share learning experiences and clinical outcomes data, to optimize technical efficiency and clinical care. Observations This was a retrospective review of a large academic institution’s initial clinical use of the da Vinci Single Port (SP) compared with the da Vinci Si (Si) system. A total of 205 TORS cases were reviewed: 109 in the SP group (November 22, 2018, through September 30, 2020), and 96 in the Si group (January 1, 2016, through November 12, 2018). Both groups had comparable operative times, rates of postoperative pharyngeal hemorrhage, length of hospital stay, and duration of nasogastric feeding tube use. There was no difference in pathological characteristics, rates of positive margins, or indications for or time to initiation of adjuvant therapy between the groups. The collective experience of 6 faculty members—who have trained 139 TORS surgeons for the SP system rollout—was compiled to provide a summary of learning experiences and technical notes on safe and efficient operation of the SP system. Conclusions and Relevance This Review found that the functional and oncologic outcomes were comparable between TORS cases performed with the Si and SP systems, and they had similar complication rates. Recognized advantages of the SP over the Si system include the availability of bipolar-energized instruments, a usable third surgical arm, and improved camera image quality.
Single‐use versus reusable rhinolaryngoscopes for inpatient otorhinolaryngology consults: Resident and patient experience
Bowen, Andrew J. , Macielak, Robert J. , Fussell, Wanda L., Yeakel, Sarah, McMillan, Ryan A. , Goates, Andrew J. , Awadallah, Andrew S. , Ekbom, Dale C. , Bowen, Andrew Jay , Macielak, Robert James , Fussell, Wanda, McMillan, Ryan, Goates, Andrew, Awadallah, Andrew

Mayo Clinic

Laryngoscope Investigative Otolaryngology | December 19, 2023 | Volume: 9 | Issue: 1 | Pages: No page available

10.1002/lio2.1203 | PMID 38362188 Get It

AbstractObjectivesSingle‐use rhinolaryngoscopes were brought to market in 2019 as an alternative to traditional reusable scopes and have garnered interest across settings given portability and potential cost advantages. While single‐use was previously evaluated compared to traditional devices, the overall impact to the consult experience for both users and patients has not been captured.MethodsEighteen residents performed consults with both single‐use and reusable rhinolaryngoscope systems on alternating weeks. A five‐question cumulative survey administered across three assessment points over a 12‐week period using a five‐point rating system to rate favorability. Residents and patients also completed four‐point scale surveys following procedure(s) to capture the consult experience. Statistical analyses were performed to measure significance differences between survey responses between the two systems.ResultsSingle‐use rhinolaryngoscopes received higher overall ratings compared with reusables across each metric captured including overall consult time (4.3 vs. 2.2, p < .001), multiscope consults (4.4 vs. 3.1, p < .001), patient communication (4.6 vs. 2.1, p < .001), teaching opportunities (4.6 vs. 2.1, p < .001), and overall ease of use (4.7 vs. 2.6, p < .001). Residents rated single‐use higher than reusable after each procedure in terms of ease of use (1.07 vs. 2.68, p < .001) and visual clarity (1.27 vs. 1.89, p = .003), while patients rated single‐use higher for understanding of illness (3.9 vs. 3.1, p < .001) and understanding of treatment rationale (3.9 vs. 3.1, p < .001).ConclusionResident and patient experience feedback favored single‐use rhinolaryngoscopes compared to reusable scope technology across multiple surveyed measurables. Single‐use rhinolaryngoscopes provide a viable tool for otorhinolaryngologist and other clinicians to perform rhinolaryngoscopy consults.Level of Evidence4.
Abstract 17144: Pi3 Kinase Activation by Platelet-Derived Purified Exosome Product to Induce Angiogenesis
Rizzo, Skylar A. , Mahlberg, Ryan , Amontree, Ashley, Peterson, Timothy E., Witt, Tyra A. , Nagel, Mary, Bagwell, Monique, Becher, Laura , Park, Sungjo , Sabbah, Michael S. , Arrell, D. Kent , Li, Mark , Kargaran, Parisa K, Li, Jialun , Kim, Yoha, Stalboerger, Paul G., Moran, Steven L. , Nagel, Mary, Bagwell, Monique S , Li, Mark , Lucien, Fabrice , Terzic, André , Behfar, Atta

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17144 Get It

Introduction: Platelets are heavily implicated in angiogenesis; however, the underlying mechanism remains relatively uncharacterized. The goal of this study was to evaluate the angiogenic potency of a platelet-derived regenerative exosome product (PEP) in an effort to develop a novel treatment for peripheral arterial disease. Here, we evaluated the mechanistic basis of PEP in angiogenesis and it’s use In Vivo in a rodent hind limb ischemia model. Methods/Results: Under Current Good Manufacturing Practices, conditioned medium from apheresis platelet cultures was purified to acquire the exosomes. PEP, enriched in exosome markers CD63, CD9 and Flotillin, induced human umbilical vein endothelial cell (HUVEC) proliferation, migration, and vascular tube formation In Vitro. Proteomic evaluation of PEP highlighted receptor tyrosine kinase (RTK) pathways and western blot validation demonstrated induction of phospho-MAPK and phospho-AKT following PEP treatment of HUVECs. Systematic evaluation of RTK receptor involvement was performed using small molecule inhibitors and receptor knock-down in HUVECs, ruling out RTK activation as a mode of action. However, small molecule inhibition of PI3 kinase demonstrated elimination of PEP-induced AKT phosphorylation and reduction in PEP-induced angiogenesis In Vitro measured by HUVEC proliferation and migration. In Vivo, evaluation of angiogenesis was performed in a rodent model of hindlimb ischemia treated with PEP embedded in fibrin glue (PEP/TISSEEL). Blood flow was evaluated by SPY angiography on day 0 pre- and post-operation, day 21, and day 28. Animals treated with PEP/TISSEEL showed a significant increase in blood flow compared to sham and TISSEEL treated animals (percent perfusion at 28 days: sham 40.9%, TISSEEL 44.3%, PEP/TISSEEL 100.2%), with significant increase in vascular area on histology (at 28 days vascular area (μm 2 )/muscle area(μm 2 ): healthy control 12.71, sham 4.66, TISSEEL 4.76, PEP/TISSEEL 15.54). Conclusions: Exosome driven activation of PI3 kinase can induce angiogenesis both In Vitro and In Vivo. PEP provides a novel, clinical-grade, off-the-shelf therapy to promote angiogenesis for the treatment of peripheral arterial disease.
Abstract 15922: Integrative Analysis of Extracellular Vesicles in Heart Transplant Rejection: From Biomarker Discovery to Novel Immune Mechanisms
Bagwell, Monique S , Abbas, Mohsin, Siddhartha, Dhivya V Meenakshi, Mahlberg, Ryan , Nagel, Mary, Witt, Tyra A. , Stalboerger, Paul G., Vitto, Humberto De, Nagel, Mary, Behfar, Atta

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.15922 Get It

Introduction: At the forefront of post-heart transplant care is early detection of transplant rejection. However, the current gold standard for detecting acute cellular transplant rejection is recurrent invasive endomyocardial biopsies (EMB). We aimed at developing a non-invasive biomarker for acute cellular heart transplant rejection (ACR) using a plasma extracellular vesicle (EV) platform. Methods: Peripheral and coronary sinus plasma samples were prospectively collected from 183 (31.7% female) patients from 2020 to 2023 during routine surveillance EMB. A discovery cohort comprised five patients who displayed ISHLT 0-1R biopsy followed by an ISHLT 2R grade rejection event. Plasma EVs were isolated from the baseline (0-1R) and rejection (2R) time points. Subsequently, integrative analysis of plasma EV proteomic, miRNomic, and metabolomics was performed pairwise with the samples. Results: The study collected 943 sample time points from 183 patients. Of these sample collections, 43 (4.5%) cases were 2R rejections. Our proteomic analysis of the plasma EVs identified 28 proteins found explicitly during a grade 2R rejection and 87 differentially expressed proteins during a 2R rejection event. An Ingenuity Pathway Analysis (IPA) analysis of the upregulated proteins highlighted EVs mediated mTOR signaling and antigen presentation as central to rejection events. Although all patients in the discovery cohort were negative for antibody-mediated rejection (AMR), the proteomic findings also revealed increased B-cell receptor signaling, implying a mechanistic intersection of ACR and AMR. Conclusions: A distinct set of proteins were found in plasma EVs during ACR events, providing potentially specific and sensitive biomarkers to reduce the need for EMB that could be exploited for ACR diagnosis. The proteins identified formed an immune signaling network that suggests a novel role for EVs in ACR pathogenesis.
Abstract 11685: Effects of Pectus Excavatum Surgical Repair on Cardiac Volumes and Systolic Function as Assessed by 3D Transesophageal Echocardiography
Mandale, Deepa, Jaroszewski, Dawn E. , Aly, Mohamed R., Botros, Michael, Moosavi, Ryan, Narayanasamy, Hemalatha , Chaliki, Hari P. , Lester, Steven J., Wilansky, Susan , Naqvi, Tasneem Z. , Farina, Juan M. , Larsen, Carolyn , Majdalany, David S , Freeman, William D. , Alsidawi, Said , Arsanjani, Reza

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.11685 Get It

Introduction: The consequences of external cardiovascular compression and cardiac displacement from pectus excavatum (PEx) are debated. The complex geometry of the right (RV) and left ventricle (LV) along with distortion from the extrinsic chest deformity pose significant limitations to reliable assessment of LV and RV volumes and function using transthoracic 2D-echocardiography in this population. Hypothesis: A 3D-echocardiography approach can reliably assess the effects of external cardiac compression and the benefits of surgical correction on RV and LV function in PEx patients. Methods: Adult patients undergoing minimally invasive repair of PEx between Oct-2021 and Feb-2023 were included in this prospective study. Intraoperative transesophageal (TEE) 6 beat full volume video loops incorporating LV and RV were captured and compared before and after surgical correction of the PEx. TomTec Software® was used for offline 3D/4D reconstruction ( Figure 1 shows changes in 3D RV and LV shape pre- and post-surgery). Result: The study included 102 patients (mean age of 32.1 ±11.8 years; Haller index 4.9 ±2.5; 60.8% males). Post PEx repair, there was a significant (p<0.001) increase in the 3D RV volumes, RV ejection fraction (EF), RV stroke volume and RV strain ( Figure 1 ). Additionally, there was a significant improvement in 3D LVEF, 3D LV strain (longitudinal and circumferential), LV twist, and torsion ( Figure 1 ). Conclusion: In this PEx cohort, 3D/4D TEE imaging demonstrated significant increases in RV volumes and in RV and LV systolic function after surgical repair. These findings support the negative cardiovascular consequences of PEx compression and benefits of surgical repair.
Prospective Multicenter Evaluation of Pain Before and After Removal of Nonobstructing Renal Calculi: A CoRE Initiative
Bhojani, Naeem , Wollin, Daniel , Tayeb, Marawan M. El , Scotland, Kymora B. , Knoedler, John, Stern, Karen , Nguyen, David‐Dan , Rivera, Marcelino , Borofsky, Michael S. , Canvasser, Noah, Bechis, Seth K. , Hsi, Ryan S. , Stern, Karen L , Hsi, Ryan

Mayo Clinic

Journal of Urology | December 15, 2023 | Volume: 211 | Issue: 3 | Pages: 436-444

10.1097/ju.0000000000003799 | PMID 38100842 Get It