Citations

Clear

1417 citation(s) found for "Li, Simon".

Left Lateral Thoracotomy for Centrifugal Continuous-Flow Left Ventricular Assist Device Placement: An Analysis from the Mechanical Circulatory Support Research Network
Maltais, Simon, Anwer, Lucman A. , Tchantchaleishvili, Vakhtang , Haglund, Nicholas, Cowger, Jennifer , Salerno, Christopher T. , Shah, Palak , Khalpey, Zain , Schmitto, Jan D. , Stulak, John M., Dunlay, Shannon M. , Tchantchaleishvili, Vakhtang , Aaronson, Keith D. , Pagani, Francis D. , Shah, Palak

Mayo Clinic

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 6 | Pages: 715-720

10.1097/mat.0000000000000714 | PMID 29095733 Get It

Continuous-flow left ventricular assist devices (CF-LVADs) have revolutionized the management of patients with advanced heart failure. Alternative implant strategies are increasingly used for device placement. We reviewed our experience from the Mechanical Circulatory Support Research Network registry with the HeartWare centrifugal CF-LVAD (HVAD). From May 2004 to August 2015, 1,150 patients underwent primary CF-LVAD implantation at our institutions. Within this group, a total of 283 patients (25%) were implanted with the HVAD. A minimally invasive left lateral thoracotomy (MILT) implant strategy was used in 53 patients (20%), of which 22 (42%) were implanted off-pump. Median age at implant was 59 years and 183 patients (65%) were implanted as bridge-to-transplantation. Follow-up was 100% complete for a total of 302 patient-years of support. In-hospital mortality was 4.9% (14 patients), and was comparable between the conventional sternotomy (CS) and MILT cohorts (p = 0.15). Patients in the MILT cohort had a shorter median length of stay (p < 0.01) and had a lower incidence of postimplant pump thrombus (p = 0.02). Cumulative survival at the end of follow-up reached 84%, and was comparable between the two groups (p = 0.298). Multivariate analysis identified preoperative bilirubin level as the only independent predictor of survival. Surgical technique had no impact on survival. In this large, multicenter experience, data demonstrate excellent survival and adverse event profiles for patients supported with the HVAD technology, regardless of surgical implant technique. With constant advancements in device technology along with our increasing clinical experience with the newer techniques, minimally invasive LVAD implantation continues to evolve as a valuable alternative to CS in selected patients.
Atrial Fibrillation Should Guide Prophylactic Tricuspid Procedures During Left Ventricular Assist Device Implantation
Anwer, Lucman A. , Tchantchaleishvili, Vakhtang , Poddi, Salvatore , Daly, Richard C. , Joyce, Lyle D., Kushwaha, Sudhir S. , Topilsky, Yan , Stulak, John M., Maltais, Simon, Topilsky, Yan , Tchantchaleishvili, Vakhtang , Topilsky, Yan

Mayo Clinic

ASAIO Journal | October 31, 2017 | Volume: 64 | Issue: 5 | Pages: 586-593

10.1097/mat.0000000000000698 | PMID 29088022 Get It

Atrial fibrillation (AF) and tricuspid regurgitation (TR) are common in patients undergoing left ventricular assist device (LVAD) implantation. TR progression is associated with the presence of AF, and questions remain as to who benefits from tricuspid valve procedures (TVPs). We examined the impact of preoperative AF on TR progression after LVAD implantation. From February 2007 to May 2014, 250 patients underwent LVAD implantation at our institution. Patients with concomitant TVP were excluded from this analysis (113 patients). The indication for LVAD was destination therapy in 80 patients (58%) and the etiology of heart failure was ischemic in 73 (53%). Follow-up was available in all early survivors for a total of 393 patient-years of support. Of the 137 non-TVP patients, 52 (38%) had AF preoperatively. Observed overall survival at 1, 3, and 5 years was 82%, 67%, and 55%, respectively. Median grade of TR increased from 2 preoperatively to 3 (p = 0.04) in the AF group and 2.2 (p = 0.75) in the non-AF group at 5 years of follow-up. We also observed a significant difference in the degree of TR between groups at 3 months (p = 0.03) and 12 months (p = 0.01) postimplantation, and a trend toward significance at 18 (p = 0.06) and 24 (p = 0.07) months. The presence of AF is associated with early progression of TR after LVAD implantation. Addition of concomitant TVP in patients with preoperative AF may be considered in patients with less than severe TR. The impact of these findings on right ventricular failure/remodeling remains to be evaluated.
Concise Review: Multifaceted Characterization of Human Mesenchymal Stem Cells for Use in Regenerative Medicine
Samsonraj, Rebekah M. , Raghunath, Michael , Nurcombe, Victor , Hui, James Hoi Po , Wijnen, André J. van , Cool, Simon M. , van Wijnen, Andre J

Mayo Clinic

Stem Cells Translational Medicine | October 27, 2017 | Volume: 6 | Issue: 12 | Pages: 2173-2185

10.1002/sctm.17-0129 | PMID 29076267 Get It

Abstract Mesenchymal stem cells (MSC) hold great potential for regenerative medicine because of their ability for self-renewal and differentiation into tissue-specific cells such as osteoblasts, chondrocytes, and adipocytes. MSCs orchestrate tissue development, maintenance and repair, and are useful for musculoskeletal regenerative therapies to treat age-related orthopedic degenerative diseases and other clinical conditions. Importantly, MSCs produce secretory factors that play critical roles in tissue repair that support both engraftment and trophic functions (autocrine and paracrine). The development of uniform protocols for both preparation and characterization of MSCs, including standardized functional assays for evaluation of their biological potential, are critical factors contributing to their clinical utility. Quality control and release criteria for MSCs should include cell surface markers, differentiation potential, and other essential cell parameters. For example, cell surface marker profiles (surfactome), bone-forming capacities in ectopic and orthotopic models, as well as cell size and granularity, telomere length, senescence status, trophic factor secretion (secretome), and immunomodulation, should be thoroughly assessed to predict MSC utility for regenerative medicine. We propose that these and other functionalities of MSCs should be characterized prior to use in clinical applications as part of comprehensive and uniform guidelines and release criteria for their clinical-grade production to achieve predictably favorable treatment outcomes for stem cell therapy.
Quantifying infective endocarditis risk in patients with predisposing cardiac conditions
Thornhill, Martin H. , Jones, Simon , Prendergast, Bernard , Chambers, John B. , Lockhart, Peter B. , Thornhill, M H , Baddour, Larry M. , Dayer, Mark

Mayo Clinic

European Heart Journal | October 24, 2017 | Volume: 39 | Issue: 7 | Pages: 586-595

10.1093/eurheartj/ehx655 | PMID 29161405 Get It

Abstract Aims There are scant comparative data quantifying the risk of infective endocarditis (IE) and associated mortality in individuals with predisposing cardiac conditions. Methods and results English hospital admissions for conditions associated with increased IE risk were followed for 5 years to quantify subsequent IE admissions. The 5-year risk of IE or dying during an IE admission was calculated for each condition and compared with the entire English population as a control. Infective endocarditis incidence in the English population was 36.2/million/year. In comparison, patients with a previous history of IE had the highest risk of recurrence or dying during an IE admission [odds ratio (OR) 266 and 215, respectively]. These risks were also high in patients with prosthetic valves (OR 70 and 62) and previous valve repair (OR 77 and 60). Patients with congenital valve anomalies (currently considered ‘moderate risk’) had similar levels of risk (OR 66 and 57) and risks in other ‘moderate-risk’ conditions were not much lower. Congenital heart conditions (CHCs) repaired with prosthetic material (currently considered ‘high risk’ for 6 months following surgery) had lower risk than all ‘moderate-risk’ conditions—even in the first 6 months. Infective endocarditis risk was also significant in patients with cardiovascular implantable electronic devices. Conclusion These data confirm the high IE risk of patients with a history of previous IE, valve replacement, or repair. However, IE risk in some ‘moderate-risk’ patients was similar to that of several ‘high-risk’ conditions and higher than repaired CHC. Guidelines for the risk stratification of conditions predisposing to IE may require re-evaluation.
Determinants of Improvement in Cardiopulmonary Exercise Testing After Left Ventricular Assist Device Implantation
Rosenbaum, Andrew , Pereira, Naveen L. , Allison, Thomas G. , Maltais, Simon, Stulak, John M., Joyce, Lyle D., Kushwaha, Sudhir S. , Rosenbaum, Andrew N , Dunlay, Shannon M.

Mayo Clinic

ASAIO Journal | October 18, 2017 | Volume: 64 | Issue: 5 | Pages: 610-615

10.1097/mat.0000000000000693 | PMID 29045277 Get It

Although improvement in cardiac output and hemodynamic parameters is routinely demonstrated in patients implanted with continuous-flow left ventricular assist devices (CF-LVADs), improvement in exercise capacity is inconsistently seen. Our purpose was to determine whether native cardiac factors, LVAD factors, or comorbid factors were associated with lack of improvement. Review of all patients undergoing preimplant cardiopulmonary exercise testing (CPET) and CPET on LVAD therapy at one institution was performed between 2007 and 2014 (n = 49). Comprehensive assessment of echocardiographic parameters, right heart catheterization data, medications, and comorbid illness was undertaken. There was no mean improvement in peak oxygen consumption (VO2; 11.8–12.4 ml/kg/min; p = 0.26), although exercise time (5.1 [46% predicted] to 5.8 min [56% predicted]; p = 0.02) and nadir of the ratio of minute ventilation to carbon dioxide production slope (VE/VCO2; 39–36; p = 0.001) improved. Factors most strongly associated with improvement in VO2 were Heartmate II pulsatility index (PI; R = 0.48; p = 0.001), power (R = −0.40; p = 0.009), pump flow (R = −0.40; p = 0.008), and pump speed (R = −0.32; p = 0.04). Peak heart rate (HR) was also associated with improvement in VO2 (R = 0.41; p = 0.004). Left ventricular ejection fraction (LVEF; R = 0.004; p = 0.77), right ventricular (RV) function (R = 0.22; p = 0.28), and aortic valve opening (R = 0.20; p = 0.57) were not associated with improvement in VO2. Our data suggest that less reliance on LVAD support was modestly associated with improvement in exercise capacity. Further studies should seek to determine the optimal level of device support prospectively in relation to exercise capacity.
Extracellular Cl− regulates electrical slow waves and setting of smooth muscle membrane potential by interstitial cells of Cajal in mouse jejunum
Saravanaperumal, Siva Arumugam , Gibbons, Simon J. , Malysz, John , Sha, Lei , Szurszewski, Joseph H., Farrugia, Gianrico , Farrugia, Gianrico , Gibbons, S J , Linden, David R.

Mayo Clinic

Experimental Physiology | October 3, 2017 | Volume: 103 | Issue: 1 | Pages: 40-57

10.1113/ep086367 | PMID 28971566 Get It

New Findings What is the central question of this study? The aim was to investigate the roles of extracellular chloride in electrical slow waves and resting membrane potential of mouse jejunal smooth muscle by replacing chloride with the impermeant anions gluconate and isethionate. What is the main finding and its importance? The main finding was that in smooth muscle cells, the resting Cl− conductance is low, whereas transmembrane Cl− movement in interstitial cells of Cajal (ICCs) is a major contributor to the shape of electrical slow waves. Furthermore, the data confirm that ICCs set the smooth muscle membrane potential and that altering Cl− homeostasis in ICCs can alter the smooth muscle membrane potential. Intracellular Cl− homeostasis is regulated by anion‐permeable channels and transporters and contributes to excitability of many cell types, including smooth muscle and interstitial cells of Cajal (ICCs). Our aims were to investigate the effects on electrical activity in mouse jejunal muscle strips of replacing extracellular Cl− (Cl−o) with the impermeant anions gluconate and isethionate. On reducing Cl−o, effects were observed on electrical slow waves, with small effects on smooth muscle membrane voltage (Em). Restoration of Cl− hyperpolarized smooth muscle Em proportional to the change in Cl−o concentration. Replacement of 90% of Cl−o with gluconate reversibly abolished slow waves in five of nine preparations. Slow waves were maintained in isethionate. Gluconate and isethionate substitution had similar concentration‐dependent effects on peak amplitude, frequency, width at half peak amplitude, rise time and decay time of residual slow waves. Gluconate reduced free ionized Ca2+ in Krebs solutions to 0.13 mm. In Krebs solutions containing normal Cl− and 0.13 mm free Ca2+, slow wave frequency was lower, width at half peak amplitude was smaller, and decay time was faster. The transient hyperpolarization following restoration of Cl−o was not observed in W/Wv mice, which lack pacemaker ICCs in the small intestine. We conclude that in smooth muscle cells, the resting Cl− conductance is low, whereas transmembrane Cl− movement in ICCs plays a major role in generation or propagation of slow waves. Furthermore, these data support a role for ICCs in setting smooth muscle Em and that altering Cl− homeostasis in ICCs can alter smooth muscle Em.
Paper #110: Unexplained Pain Following Total Knee Arthroplasty is Rotational Malalignment the Problem?
Young, Simon W. , Spangehl, Mark J. , Clarke, Henry D.

Mayo Clinic

Arthroscopy | September 29, 2017 | Volume: 33 | Issue: 10S | Pages: No page available

10.1016/j.arthro.2017.08.087 Get It

Seven tips for developing and maintaining a high performance sports medicine team
Gabbett, Tim J. , Kearney, Simon, Bisson, Leslie J. , Sikka, Robby , Winder, Nathan, Sedgwick, Craig, Hollis, Ed , Bettle, Jeremy M., Collins, Joe T.

Mayo Clinic

British Journal of Sports Medicine | September 27, 2017 | Volume: 52 | Issue: 10 | Pages: 626-627

10.1136/bjsports-2017-098426 | PMID 28954792 Get It