Citations

Clear

150 citation(s) found for "Singh, Ravinder".

Recommendations for the Generation, Quantification, Storage, and Handling of Peptides Used for Mass Spectrometry–Based Assays
Hoofnagle, Andrew N. , Carr, Steven A. , Liu, Tao , Massoni, Sam A., Thomas, Stefani N. , Townsend, R. Reid , Zimmerman, Lisa J. , Boja, Emily S. , Chen, Jing , Crimmins, Daniel L., Davies, Sherri R. , Hiltke, Tara , Ketchum, Karen A. , Kinsinger, Christopher R. , Mesri, Mehdi , Meyer, Matthew R. , Qian, Weijun , Schoenherr, Regine M., Scott, Mitchell G., Shi, Tujin , Whiteley, Gordon , Wrobel, John A. , Wu, Chaochao, Ackermann, Brad, Barnidge, David R. , Bunk, David M. , Clarke, Nigel J. , Fishman, Jordan B., Grant, Russ P., Kushnir, Mark M. , Lowenthal, Mark S. , Neubert, Hendrik , Patterson, Scott D. , Rockwood, Alan L. , Rogers, John , Eyk, Jennifer E. Van , Wong, Steven, Zhang, Shucha, Chan, Daniel W. , Chen, Xian , Liebler, D.C. , Rodland, Karin , Rodriguez, Henry , Paulovich, Amanda G. , Whiteaker, Jeffrey R. , Kuhn, Eric W. , Gao, Yuqian , Aebersold, Ruedi , Grant, Russell P. , Kusebauch, Ulrike , Moritz, Robert L. , Singh, Ravinder J. , Ellis, Matthew J. , Smith, Richard , Zhang, Zhen , Zhang, Hui , Davies, S. J.

Mayo Clinic

Clinical Chemistry | December 30, 2015 | Volume: 62 | Issue: 1 | Pages: 48-69

10.1373/clinchem.2015.250563 | PMID 26719571 Get It

AbstractBACKGROUNDFor many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope–labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays.CONTENTThe Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials—in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry—is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.
LC-MS/MS for Identifying Patients with CYP24A1 Mutations
Ketha, Hemamalini , Kumar, Rajiv , Singh, Ravinder J. , Kumar, Rajiv

Mayo Clinic

Clinical Chemistry | December 30, 2015 | Volume: 62 | Issue: 1 | Pages: 236-242

10.1373/clinchem.2015.244459 | PMID 26585929 Get It

Abstract BACKGROUND Patients have been described with loss-of-function CYP24A1 (cytochrome P450, family 24, subfamily A, polypeptide 1) mutations that cause a high ratio of 25-hydroxyvitamin D to 24,25-dihydroxyvitamin D [25(OH)D/24,25(OH)2D], increased serum 1,25-dihydroxyvitamin D, and resulting hypercalcemia, hypercalciuria and nephrolithiasis. A 25(OH)D/24,25(OH)2D ratio that can identify patients who are candidates for confirmatory CYP24A1 genetic testing would be valuable. We validated an LC-MS/MS assay for 24,25(OH)2D (D3 and D2) and determined a 25(OH)D/24,25(OH)2D cutoff to identify candidates for confirmatory genetic testing. METHODS After addition of isotope-labeled internal standard, serum samples were extracted by solid-phase extraction, derivatized with 4-phenyl-1,2,4,-triazoline-3,5-dione, and quantified by LC-MS/MS. We measured 25(OH)D/24,25(OH)2D in 91 healthy patients and 34 patients with clinically suspected CYP24A1-mediated hypercalcemia. RESULTS The limits of detection and quantification were 0.03 (0.2) and 0.1 (0.24) nmol/L, respectively, for 24,25(OH)2D3, and 0.1 (0.23) and 0.5 (1.16) nmol/L for 24,25(OH)2D2. Intra- and interassay imprecision was 4%–15% across the analytical measurement range of 0.1–25 ng/mL (0.2–60 nmol/L). No interference was observed with 25(OH)D and 1,25(OH)2D. 25(OH)D/24,25(OH)2D of 7–35 was observed in healthy patients, whereas in 2 patients with CYP24A1 mutations, 25(OH)D/24,25(OH)2D was significantly increased (99–467; P < 0.001). A 25(OH)D/24,25(OH)2D ratio ≥99 identified patients who were candidates for CYP24A1 genetic testing. CONCLUSIONS Increased 25(OH)D/24,25(OH)2D supports the diagnosis of reduced CYP24A1 activity due to mutations in CYP24A1. Measurement of 25(OH)D/24,25(OH)2D should be considered a part of the clinical workup in patients with hypercalcemia of otherwise unknown etiology.
A Spectrum of Views on Clinical Mass Spectrometry
Annesley, Thomas M, Diamandis, Eleftherios P. , Bachmann, Lorin M, Hart, Bradley R. , Javahery, Reza, Hanash, Samir , Singh, Ravinder , Smith, Richard , Diamandis, Eleftherios

Mayo Clinic

Clinical Chemistry | November 10, 2015 | Volume: 62 | Issue: 1 | Pages: 30-36

10.1373/clinchem.2015.250258 | PMID 26553793 Get It

Serum 25-Hydroxyvitamin D Levels: Variability, Knowledge Gaps, and the Concept of a Desirable Range
Fuleihan, Ghada El‐Hajj , Bouillon, Roger , Chakhtoura, Marlene , Cooper, Cyrus , Clarke, Bart, Clarke, B.L. , McClung, Michael R. , Singh, Ravinder J. , Cooper, Cyrus , El-Hajj Fuleihan, Ghada

Mayo Clinic

Journal of Bone and Mineral Research | May 8, 2015 | Volume: 30 | Issue: 7 | Pages: 1119-1133

10.1002/jbmr.2536 | PMID 25952470 Get It

ABSTRACT Hypovitaminosis D is prevalent worldwide but proportions vary widely between regions, depending on genetic and lifestyle factors, the threshold to define deficiency, and accuracy of 25-hydroxyvitamin D (25OHD) assays used. Latitude, pollution, concealing clothing, sun exposure, gender, dietary habits, and lack of government regulation account for up to 50% in variations in serum 25OHD levels, whereas genetic polymorphisms in the vitamin D pathway account for less than 5%. Organizations/societies have developed guidelines for recommended desirable 25OHD levels and vitamin D doses to reach them, but their applicability across age groups and populations are still debated. This article and the accompanying online Supporting Information highlight sources of variations in circulating 25OHD levels, uncertainties and knowledge gaps, and analytical problems facing 25OHD assays, while keeping efficacy and safety data as the dominant factors when defining a desirable range for 25OHD levels. We propose a desirable range of 20 to 40 ng/mL (50 to 100 nmol/L), provided precise and accurate assays are used. Although slightly lower levels, 15 to 20 ng/mL, may be sufficient for some infants and adults, higher levels, 40 to 60 ng/mL, may still be safe. This desirable range allows physicians to tailor treatment while taking season, lifestyle, vitamin D intake, and other sources of variation into account. We reserve 25OHD measurements for at-risk patients, defined by disease or lifestyle, and the use of 25OHD assays calibrated against the recommended international standards. Most target groups reach desirable target levels by a daily intake of 400 to 600 IU for children and 800 IU for adults. A total daily allowance of vitamin D of up to 1000 IU in the pediatric age groups, and up to 2000 IU in adults, tailored to an individual patient risk profile, is probably safe over long durations. Additional data are needed to validate the proposed range and vitamin D doses, especially in children, pregnant women, and non-white populations. © 2015 American Society for Bone and Mineral Research.
Detection of IGF-1 Protein Variants by Use of LC-MS with High-Resolution Accurate Mass in Routine Clinical Analysis
Hines, Jolaine, Ketha, Hemamalini , Grebe, Stefan K., Milošević, Dragana , Taylor, Robert L. , Algeciras‐Schimnich, Alicia , Singh, Ravinder

Mayo Clinic

Clinical Chemistry | April 28, 2015 | Volume: 61 | Issue: 7 | Pages: 990-991

10.1373/clinchem.2014.234799 | PMID 25922441 Get It

Mass Spectrometric Immunoassay Raises Doubt for the Existence of Parathyroid Hormone Fragment 7–84
Hines, Jolaine M., Lopez, Mary F., Krastins, Bryan, Hoofnagle, Andrew N. , Singh, Ravinder

Mayo Clinic

Clinical Chemistry | January 18, 2015 | Volume: 61 | Issue: 3 | Pages: 558-560

10.1373/clinchem.2014.235440 | PMID 25597752 Get It

Serum Concentrations of Prostate-Specific Antigen Measured Using Immune Extraction, Trypsin Digestion, and Tandem Mass Spectrometry Quantification of LSEPAELTDAVK Peptide
Klee, Eric W. , Bondar, Olga P., Goodmanson, Marcia K., Trushin, Sergey A., Bergstralh, Eric J., Anderson, N. Leigh , Klee, George G., Singh, Ravinder J.

Mayo Clinic

Archives of Pathology and Laboratory Medicine | September 30, 2014 | Volume: 138 | Issue: 10 | Pages: 1381-1386

10.5858/arpa.2013-0462-oa | PMID 25268201 Get It

Context.— Prostate-specific antigen (PSA) is a 34-kDa glycoprotein with chymotrypsin-like enzyme activity that circulates both in free forms and complexed to various enzyme inhibitors including antichymotrypsin and α 2 -macroglobulin. Prostate-specific antigen bound to α 2 -macroglobulin is not detected by commercial PSA immunoassays. Objective.— To develop a mass spectrometry assay that detects the same forms of PSA as the immunoassays, which could serve as a reference for harmonizing PSA immunoassays. Design.— Prostate-specific antigen was immune extracted from serum, trypsin was digested, and the LSEPAELTDAVK peptide was quantitated on an API 5000 spectrometer. Calibrators were made by adding 10% free and 90% antichymotrypsin-bound PSA to female sera. The assay was standardized to the World Health Organization 96/670 reference standard. Validation of clinical utility and comparisons with 2 immunoassays (Roche cobas and Beckman Access) were performed using frozen sera aliquots from 100 men undergoing prostate biopsy (50 negative, 50 with cancer) and 5 serial samples collected over time from 5 men with advanced prostate cancer. Results.— The antibody extraction efficiency was greater than 99%. The assay has an analytic range from 1.2 to 76 ng/mL, with precision ranging from 8.6% at 1.5 ng/mL to 5.4% at 27 ng/mL. The mass spectrometry assay correlated well with 2 immunoassays. All 3 assays showed statistically equivalent separation of prostate cancer from benign disease using receiver operating characteristic curve analysis. Conclusions.— This mass spectrometry assay can reliably measure PSA concentrations in human serum and could serve as a reference standard for harmonizing PSA immunoassays.
Lactulose
Lee, Gwenyth O. , Kosek, Peter, Lima, Aldo Â. M. , Yori, Pablo Peñataro , Lamsam, Jesse, Oliveira, Domingos B., Guerrant, Richard L., Kosek, Margaret , Singh, Ravinder J. , Olórtegui, Maribel Paredes

Mayo Clinic

Journal of Pediatric Gastroenterology and Nutrition | June 17, 2014 | Volume: 59 | Issue: 4 | Pages: 544-550

10.1097/mpg.0000000000000459 | PMID 24941958 Get It

ABSTRACTObjectives:The lactulose:mannitol (L:M) diagnostic test is frequently used in field studies of environmental enteropathy (EE); however, heterogeneity in test administration and disaccharide measurement has limited the comparison of results between studies and populations. We aim to assess the agreement between L:M measurement between high‐performance liquid chromatography with pulsed amperometric detection (HPLC‐PAD) and liquid chromatography‐tandem mass spectrometry (LC‐MSMS) platforms.Methods:The L:M test was administered in a cohort of Peruvian infants considered at risk for EE. A total of 100 samples were tested for lactulose and mannitol at 3 independent laboratories: 1 running an HPLC‐PAD platform and 2 running LC‐MSMS platforms. Agreement between the platforms was estimated.Results:The Spearman correlation between the 2 LC‐MSMS platforms was high (ρ ≥ 0.89) for mannitol, lactulose, and the L:M ratio. The correlation between the HPLC‐PAD platform and LC‐MSMS platform was ρ = 0.95 for mannitol, ρ = 0.70 for lactulose, and ρ = 0.43 for the L:M ratio. In addition, the HPLC‐PAD platform overestimated the lowest disaccharide concentrations to the greatest degree.Conclusions:Given the large analyte concentration range, the improved accuracy of LC‐MSMS has important consequences for the assessment of lactulose and mannitol following oral administration in populations at risk for EE. We recommend that researchers wishing to implement a dual‐sugar test as part of a study of EE use an LC‐MSMS platform to optimize the accuracy of results and increase comparability between studies.
Mass Spectrometry Measurements of Prostate-Specific Antigen (PSA) Peptides Derived From Immune-Extracted PSA Provide a Potential Strategy for Harmonizing Immunoassay Differences
Klee, Eric W. , Bondar, Olga P., Goodmanson, Marcia K., Trushin, Sergey A., Anderson, N. Leigh , Klee, George G., Singh, Ravinder J.

Mayo Clinic

American Journal of Clinical Pathology | March 11, 2014 | Volume: 141 | Issue: 4 | Pages: 527-533

10.1309/ajcp8pel0yxahdvk | PMID 24619754 Get It

Immunological and Mass Spectrometric Assays of SHBG: Consistent and Inconsistent Metabolic Associations in Healthy Men
Veldhuis, Johannes D. , Bondar, Olga P., Dyer, Roy B. , Trushin, Sergey A., Klee, Eric W. , Klee, George G., Singh, Ravinder J.

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | November 8, 2013 | Volume: 99 | Issue: 1 | Pages: 184-193

10.1210/jc.2013-2642 | PMID 24203061 Get It