Citations

Clear

196 citation(s) found for "Schaff, Hartzell".

Long-term outcomes of patients undergoing tricuspid valve surgery†
Saran, Nishant , Said, Sameh M. , Greason, Kevin L. , Pochettino, Alberto , Stulak, John M., Maltais, Simon, Çïçek, Sertaç , Daly, Richard C. , King, Katherine S. , Dearani, Joseph A. , Crestanello, Juan A. , Schaff, Hartzell V.

Mayo Clinic

European Journal of Cardio-Thoracic Surgery | February 21, 2019 | Volume: 56 | Issue: 5 | Pages: 950-958

10.1093/ejcts/ezz081 | PMID 30919898 Get It

Abstract OBJECTIVES Limited literature is available on the best management strategy for tricuspid valve (TV) disease in adults. We sought to review our long-term outcomes of TV surgery with regard to survival and reoperation. METHODS A retrospective analysis of all patients ≥18 years of age [n = 2541, aged 67 ± 13years, 1433 (56%) females] who underwent first-time TV surgery between January 1993 and December 2013 was done. There were 1735 patients who received TV repair and 806 patients underwent replacement. A gradient boosting machine model was used to derive a propensity score for predicting replacement using 27 preoperative characteristics. Four hundred and eighteen propensity-matched pairs of TV repair and replacement were identified. Cox proportional hazard regression was used on the matched subset to determine the effect of replacement. RESULTS Functional TV regurgitation was present in 54% (n = 1369). A bioprosthesis was used in 84% (n = 680) of replacements, while 54% (n = 934) of TV repairs were ring annuloplasties. Operative mortality was 8% (n = 212). Overall survival was 54%, 29% and 13% at 5, 10 and 15 years, respectively. After propensity score matching, replacement was significantly associated with increased mortality [hazard ratio (HR) 1.54, 95% confidence interval (CI) 1.18–2.00; P = 0.001]. The cumulative incidence of TV reoperation was similar between the 2 groups when accounting for the competing risk of death [Fine–Gray HR 1.56, 95% CI 0.9–2.8; P = 0.144]. CONCLUSIONS TV surgery is associated with poor outcomes due to multiple patient comorbidities. TV repair results in better survival compared to replacement in patients with similar comorbidities with no increased risk of getting a reoperation.
Pericardiotomy Enhances Left Ventricular Diastolic Reserve With Volume Loading in Humans
Borlaug, Barry A. , Pochettino, Alberto , Pedrotty, Dawn , Asirvatham, Samuel J. , Carter, Rickey E. , Mauermann, William J., Pedrotty, Dawn M, Abel, Martin D, Asirvatham, Samuel J , Borlaug, Barry A , Carter, Rickey E , Schaff, Hartzell V. , Abel, Martin

Mayo Clinic

Circulation | January 7, 2019 | Volume: 138 | Issue: 20 | Pages: 2295-2297

10.1161/circulationaha.118.036006 | PMID 30571519 Get It

Laparoscopic Transdiaphragmatic Access to the Apex of the Left Ventricle of the Heart
Thompson, Jess L., Suri, Rakesh M. , McKellar, Stephen H. , Schaff, Hartzell V.

Mayo Clinic

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 3, 2019 | Volume: 4 | Issue: 1 | Pages: 27-31

10.1177/155698450900400106 Get It

Robot-Assisted Aortic Valve Replacement Using a Novel Sutureless Bovine Pericardial Prosthesis Proof of Concept as an Alternative to Percutaneous Implantation
Suri, Rakesh M. , Burkhart, Harold M. , Schaff, Hartzell V.

Mayo Clinic

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 3, 2019 | Volume: 5 | Issue: 6 | Pages: 419-423

10.1177/155698451000500607 | PMID 22437637 Get It

Objective Percutaneous aortic valve implantation within native valve calcium has progressed to clinical use despite the absence of data proving equivalence to complete surgical excision and prosthetic valve replacement. A novel self-expanding sutureless bovine pericardial prosthesis (Sorin Perceval) derived from a proven stented valve has been successfully used in humans recently through an open transaortic approach. We sought to develop a minimally invasive technique for native aortic valve excision and sutureless prosthetic aortic valve replacement using robot assistance. Methods The da Vinci S-HD system was used to open and suspend the pericardium anterior to the phrenic nerve in cadavers. A transthoracic cross-clamp was placed across the midascending aorta, following which a transverse aortotomy was made. The native aortic valve cusps were excised, and annular calcium was removed with robotic instruments. After placement of three guide sutures, the Perceval self-expanding pericardial prosthesis mounted on a flexible delivery system was inserted through a working port and lowered into the aortic annulus. Results Successful implantation of all valves was possible using a 3-cm right second intercostal space working port, along with two additional 1-cm instrument ports. A standard transverse aortotomy was sufficient for examination/debridement of the native aortic valve cusps, sizing of the annulus, and deployment of the nitinol-stented, bovine pericardial prosthesis. Delivery, seating, and stability of the device were easily confirmed above and below the aortic valve annulus using the robotic camera. Conclusions Complete excision of diseased native aortic valve cusps with robot assistance facilitates accurate and reproducible aortic valve replacement using a novel self-expanding sutureless version of a proven bovine pericardial prosthesis. This approach is comparable to the current surgical gold standard and is ready for clinical use as an alternative to percutaneous aortic valve implantation.
Coexistent bicuspid aortic valve and mitral valve prolapse: epidemiology, phenotypic spectrum, and clinical implications
Padang, Ratnasari , Enriquez‐Sarano, Maurice , Pislaru, Sorin V. , Maalouf, Joseph F., Mankad, Sunil , Maltais, Simon, Suri, Rakesh M. , Mankad, Sunil V., Sabbah, Michael S. , Enriquez-Sarano, Maurice , Nkomo, Vuyisile T. , Schaff, Hartzell V. , Michelena, Héctor I.

Mayo Clinic

European Heart Journal - Cardiovascular Imaging | October 10, 2018 | Volume: 20 | Issue: 6 | Pages: 677-686

10.1093/ehjci/jey166 | PMID 30445616 Get It

P4582Tricuspid valve regurgitation in patients with constrictive pericarditis
Calderon-Rojas, Rolando , Greason, Kevin L. , Oh, J K, Maltais, S., Bagameri, Gabor, Cicek, S, Stulak, John M., Daly, Richard C. , Pochettino, Alberto , Crestanello, Juan A. , Cicek, S, Said, Sameh M. , Schaff, Hartzell V.

Mayo Clinic

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p4582 Get It

What is the role of apical ventriculotomy in children and young adults with hypertrophic cardiomyopathy?
Thompson, Alex , Dearani, Joseph A. , Johnson, Jonathan N. , Schaff, Hartzell V. , Towe, Eric, Palfreeman, Jared, Wackel, Philip L. , Cetta, Frank , Thompson, Alex J , Towe, Eric C, Schaff, Hartzell , Dearani, Joseph A.

Mayo Clinic

Congenital Heart Disease | July 19, 2018 | Volume: 13 | Issue: 4 | Pages: 617-623

10.1111/chd.12618 | PMID 30019505 Get It

Vitamin C for Vasoplegia After Cardiopulmonary Bypass: A Case Series
Wieruszewski, Patrick M. , Nei, Scott D. , Maltais, Simon, Schaff, Hartzell V. , Wittwer, Erica D. , Schaff, Hartzell , Wieruszewski, Patrick M

Mayo Clinic

A&A Practice | July 11, 2018 | Volume: 11 | Issue: 4 | Pages: 96-99

10.1213/xaa.0000000000000752 | PMID 29634537 Get It

Cardiac vasoplegia remains a significant contributor of morbidity and mortality in cardiac surgery patients after cardiopulmonary bypass. Effective therapeutic options for vasopressor-refractory vasoplegia are limited. We report 3 patients in whom we administered high-dose intravenous ascorbic acid (vitamin C), a cofactor for endogenous catecholamine synthesis, to treat vasoplegia refractory to epinephrine, vasopressin, and norepinephrine after surgery requiring cardiopulmonary bypass. Reductions in vasopressor requirements were observed in all 3 patients, and, in 2 patients, norepinephrine was completely discontinued within 24 hours. Ascorbic acid is a novel potential therapeutic option for cardiac vasoplegia that warrants rigorous prospective studies.
Response by Nguyen et al to Letter Regarding Article, “Early Outcomes of Repair of Left Ventricular Apical Aneurysms in Patients with Hypertrophic Cardiomyopathy”
Nguyen, Anita , Schaff, Hartzell V. , Ommen, Steve R. , Schaff, Hartzell , Nishimura, Rick A. , Dearani, Joseph A.

Mayo Clinic

Circulation | May 21, 2018 | Volume: 137 | Issue: 21 | Pages: 2303-2304

10.1161/circulationaha.118.033776 | PMID 29784686 Get It

Effects of transdermal nicotine treatment on structure and function of coronary artery bypass grafts
Yamaguchi, Hiroki , Hurt, R. Douglas , Fitzpatrick, Lorraine A. , Moyer, Thomas P. , Rowland, C, Miller, Virginia M. , Clouse, William Darrin , Phillips, Michael , Schaff, Hartzell V.

Mayo Clinic

Journal of Applied Physiology | December 23, 2017 | Volume: 89 | Issue: 3 | Pages: 1213-1223

10.1152/jappl.2000.89.3.1213 | PMID 10956371 Get It

Smoking is a major risk factor for failure of coronary artery bypass grafts (CABG). Experiments were designed to determine effects of transdermal nicotine, independent of smoking, on structure and function of CABG. Saphenous veins were placed as CABG in untreated dogs (control) or in dogs treated with transdermal nicotine (one 11-mg or two 22-mg patches/day) for 5 wk. Serum nicotine and plasma nitric oxide were measured. Grafts were removed and prepared for organ chamber studies and histology. Serum nicotine averaged 12.1 and 118.7 ng/ml in the 11 mg/day and 44 mg/day groups, respectively. Plasma nitric oxide was higher in dogs treated with 11 mg/day doses compared with controls. In organ chamber studies, endothelium-dependent relaxations to thrombin and A-23187 and endothelium-independent relaxations to nitric oxide were greatest in grafts from dogs treated with 11 mg/day doses. Intimal thickness of the grafts were similar among groups. However, staining for bone sialoprotein was increased in the media of grafts from the 11 mg/day treatment group. These data suggest that transdermal nicotine in doses comparable and double to those used for conventional smoking cessation treatment in humans does not adversely affect early patency of canine CABG up to 4 wk postoperatively. Transdermal nicotine, however, may increase production of and response to nitric oxide in bypass grafts.