Abstract AL is a rare plasma cell disorder, resulting from clonal bone marrow plasma cells secreting immunoglobulin light chains (LC), which aggregate abnormally into fibrils, and leads to amyloid deposits in different organs. Previous studies using LC immunopurification and MALDI-TOF/MS (MASS-FIX) on patients with known plasma cell disorders (PCDs), demonstrated that monoclonal LC from AL patients display unusually complex mass to charge spectra (m/z) for their LCs at much higher frequencies than other PCDs such as multiple myeloma. We hypothesized that these were post-translational modification, presumably glycoforms. Here, we report investigations into LC glycosylation using MASS- FIX. Serum from 212 lambda and 72 kappa AL patients were collected following Mayo Clinic IRB guidelines. LC was purified from serum using nanobody enrichment method, followed by MASS-FIX. The LCs spectra acquired on MASS-FIX were visually analyzed and were classified into different patterns. The kappa and lambda LC mass distributions with abnormal complex patterns were interrogated for the presence of glycosylation by exposure to the LC to a deglycoslylating enzyme (PNGase F) and analysis of LC mass distribution using MASS-FIX and by LC-ESI-Orbitrap. Monoclonal LCs demonstrating significantly mass shifted peak outside the normal kappa and lambda mass distribution were observed in 31% of kappa and 6% of lambda patients with AL. In order to determine if this characteristic mass shift was due to glycosylation, 16 kappa and 6 lambda LCs were treated with a PNGase F and LC spectrum were re-examined by MASS-FIX and LC-ESI-Orbitrap. The monoclonal LCs whose masses were significantly shifted beyond normal kappa and lambda mass distributions were found to shift to lower molecular weight after PNGase F treatment, confirming the presence of N-glycosylation. Moreover, an additional 5 kappa and 23 lambda samples had other complex patterns, typically with multiple additional peaks at increments of 162 Da. These samples did not shift with PNGase F suggesting either glycation or O-glycosylation. This work is significant as it confirms that N-glycosylated LCs are over represented in patients with AL in comparison to other PCDs. In patients with AL, the frequency of N-glycosylation of kappa LC clones was 5 times higher than that of lambda LC clones. More work is needed to explore the mechanism for this finding, the role of glycosylation in fibril formation, and the other complex patterns observed. In addition, MASS-FIX method used in this work is currently being validated in the clinical lab such that rapid detection of N-glycosylation in patients with monoclonal gammopathies will be possible routinely, potentially leading to earlier clinical suspicion for AL among patients with monoclonal gammopathies and hence to earlier detection of AL. Citation Format: Sanjay Kumar, Angela Dispenzieri, Surendra Dasari, Paolo Milani, Giampaolo Merlini, MeLea Hetrick, David Barnidge, Benjamin Madden, David Murray. Mass spectrometric approach to identify N-glycosylation of light chain in patients with immunoglobulin light chain amyloidosis (AL) [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2018; 2018 Apr 14-18; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2018;78(13 Suppl):Abstract nr 2693.
MASS‐FIX may allow identification of patients at risk for light chain amyloidosis before the onset of symptoms
AbstractBackgroundSince the first monoclonal antibody (mAb) therapy hit the market in 1996, the number of disorders treated with this class of therapeutics has seen tremendous growth, with over 50 antibody-based therapeutics currently approved for use in the US and Europe. This class of therapeutics recently made profound progress in the treatment of refractory multiple myeloma (MM). Treating MM with the mAbs will challenge the laboratory's ability to differentiate exogenous mAbs being used to treat patients from endogenous mAbs associated with disease.ContentAn overview of the therapeutic mAbs (t-mAbs) developed for the treatment of MM is provided. The anticipated impact of these therapies on patient care, laboratory testing, and clinical research is discussed. Efforts underway to develop strategies and technologies to help laboratories address the growing challenge of mAb interferences are reviewed.SummaryLaboratories can implement risk mitigation strategies at the preanalytical and postanalytical phase of testing to reduce the likelihood of reporting false-positive M-protein results in patients receiving t-mAbs. However, at the analytical phase of testing, current laboratory methods are ill-suited to differentiate between residual disease and residual drugs. Mass spectrometry–based methods might be best positioned to aid laboratories with the rapidly evolving landscape of MM treatment.
A universal solution for eliminating false positives in myeloma due to therapeutic monoclonal antibody interference
Context.— Serum tests used for the screening and diagnosis of monoclonal gammopathies include serum protein electrophoresis (SPE; agarose gel or capillary zone), immunofixation (IFE) and immunosubtraction capillary electrophoresis, serum free light chains, quantitative immunoglobulins, and heavy/light–chain combinations. Urine protein electrophoresis and urine IFE may also be used to identify Bence-Jones proteinuria. Objective.— To assess current laboratory practice for monoclonal gammopathy testing. Design.— In April 2016, a voluntary questionnaire was distributed to 923 laboratories participating in a protein electrophoresis proficiency testing survey. Results.— Seven hundred seventy-four laboratories from 38 countries and regions completed the questionnaire (83.9% response rate; 774 of 923). The majority of participants (68.6%; 520 of 758) used agarose gel electrophoresis as their SPE method, whereas 31.4% (238 of 758) used capillary zone electrophoresis. The most common test approaches used in screening were SPE with reflex to IFE/immunosubtraction capillary electrophoresis (39.3%; 299 of 760); SPE only (19.1%; 145 of 760); SPE and IFE or immunosubtraction capillary electrophoresis (13.9%; 106 of 760); and SPE with IFE, serum free light chain, and quantitative immunoglobulins (11.8%; 90 of 760). Only 39.8% (305 of 767) of laboratories offered panel testing for ordering convenience. Although SPE was used by most laboratories in diagnosing new cases of myeloma, when laboratories reported the primary test used to follow patients with monoclonal gammopathy, only 55.7% (403 of 724) chose SPE, with the next most common selections being IFE (18.9%; 137 of 724), serum free light chain (11.7%; 85 of 724), and immunosubtraction capillary electrophoresis (2.1%; 15 of 724). Conclusions.— Ordering and testing practices for the screening and diagnosis of monoclonal gammopathy vary widely across laboratories. Improving utilization management and report content, as well as recognition and development of laboratory-directed testing guidelines, may serve to enhance the clinical value of testing.
Myocardial Cobalt Levels Are Elevated in the Setting of Total Hip Arthroplasty
Background: Arthroplasty implants commonly contain elemental metal that may undergo wear-related release. Recently, cases of hip implant-associated myocardial injury have been reported. However, we are not aware of any previous study that has systematically measured myocardial metal levels or examined the relationship with total hip arthroplasty (THA). Methods: Archives of our institution were queried for autopsies of individuals who had undergone THA between 1990 and 2013. Myocardial tissue samples were analyzed for cobalt (Co) and chromium (Cr) levels with inductively coupled plasma mass spectroscopy. Seventy-five Co/Cr-on-polyethylene THA cases were included (mean age at time of death = 77.4 years; 49% women) as were 73 non-arthroplasty controls matched for age, sex, and history of hypertension and diabetes mellitus. Results: Significantly higher median myocardial concentrations of Co were observed in individuals with THA compared with controls (0.12 versus 0.06 μg/g, p < 0.0001). The median Co concentration was 69% higher in patients who had undergone THA revision (0.169 μg/g) than in those who underwent primary THA (0.100 μg/g; p = 0.004). In general, higher Co levels were observed in those with multiple replaced joints, although this finding only trended toward significance. Cardiomegaly, interstitial fibrosis, and decreased ejection fraction were observed more frequently in the postmortem samples of patients with implants than in those of controls (p = 0.0002, 0.044, and 0.0039, respectively). Conclusions: We believe this to be the first study to quantify metal levels in cardiac tissue in patients with and without joint replacement. The elevated Co levels, in concert with cardiomegaly and increased interstitial fibrosis found during autopsy, in the arthroplasty cohort are novel, important findings. Although Co levels were significantly elevated above those in controls, the majority were below those seen in clinical case reports of death from Co cardiotoxicity associated with metal-on-metal prostheses. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities