BackgroundEndocardial ablation approaches targeting the retroatrial cardiac ganglia to treat atrial fibrillation (AF) have been proposed. However, the potential value using this approach is unknown. Disruption of the autonomic inputs with orthotropic heart transplant (OHT) provides a unique opportunity to study the effects of autonomic innervation on AF genesis and maintenance. We hypothesized that due to denervation, the risk of postoperative AF would be lower following OHT compared to surgical maze even though both groups get isolation of the pulmonary veins.Methods and ResultsWe reviewed 155 OHTs (mean age 52 ± 11 years, 72% males) and used 1:1 age‐, sex‐, and date‐of‐surgery‐matched two control groups from patients undergoing surgical maze or only coronary artery bypass grafting (CABG). Using conditional logistic regression we compared the odds of AF within 2 weeks following OHT versus controls. Postoperative AF occurred in 10/155 (6.5%) OHT patients. The conditional odds of postoperative AF were lower for OHT as compared to controls (vs maze: odds ratio [OR] 0.27 [95% confidence interval (CI) 0.13–0.57], vs CABG: OR 0.38 [0.17–0.81], P = 0.003; and on additional adjustment for left atrial enlargement, vs maze: OR 0.28 [0.13–0.60], vs CABG: OR 0.14 [0.04–0.47], P = 0.0009).ConclusionsRisk of postoperative AF is significantly lower with OHT as in comparison to surgical maze. As both surgeries entail isolation of the pulmonary veins but only OHT causes disruption of autonomic innervation, this observation supports a mechanistic role of autonomic nervous system in AF. The benefit of targeting the cardiac autonomic system to treat AF needs further investigation.
Background— Infection is a serious complication of cardiovascular implantable electronic device (CIED) placement and requires device removal for attempted cure. Methods and Results— We studied the rate, risk factors, and outcomes of CIED infection in 74 consecutive patients with bacteremia caused by Gram-positive cocci (GPC) other than Staphylococcus aureus between 2001 and 2007. CIED infection was defined as the presence of signs of infection at the generator site, lead vegetations seen on echocardiography, or microbiological growth from device cultures. Twenty-two (30%) of 74 patients with non– S aureus GPC bacteremia had CIED infections. Coagulase-negative staphylococci (CoNS) accounted for 73% of CIED infections. The rate of CIED infection in patients with CoNS bacteremia was almost 2-fold that of non-CoNS GPC bacteremia (36% versus 20%, P =0.13). The number of leads, the presence of abandoned leads, and prior generator replacement were associated with CIED infection. Among 33 patients without identifiable CIED infection at initial evaluation who did not undergo device removal, 5 (15%) had relapsing bacteremia within 12 weeks of completing antibiotic therapy. CoNS accounted for all relapses, and none had evidence of CIED infection at relapse. Conclusions— Patients with a CIED and bacteremia caused by GPC other than S aureus frequently had evidence of underlying CIED infection on clinical evaluation that included transesophageal echocardiography. This was particularly true among those with CoNS bacteremia. No evidence of underlying CIED infections was identified in the subgroup of patients who did not have manifestations of CIED infection on initial evaluation but subsequently had relapsing bacteremia caused by CoNS.