Citations

Clear

142 citation(s) found for "Hsieh, TC".

PMO-31 Rapidity of ulcerative colitis symptom improvements during filgotinib induction: phase 2b/3 SELECTION study post-hoc analysis
Morison, Ben, Hibi∥, Toshifumi , Ritter, Timothy E., Dinoso, Jason B., Hsieh, Jeremy, Yun, Chohee , Zhao, Sally, Danese, Silvio , Zhang, Jie , Loftus, Edward V. , Rogler, Gerhard

Mayo Clinic

Posters | November 7, 2021 | Volume: No volume available | Issue: No issue available | Pages: A93.1-A93

10.1136/gutjnl-2021-bsg.170 Get It

PMO-30 Corticosteroid-free remission of ulcerative colitis with filgotinib maintenance therapy: post-hoc analysis of the SELECTION study
Morison, Ben, Vermeire, Séverine , Feagan, Brian, Yun, Chohee , Hsieh, Jeremy, Liu, Xiaopeng, Zhao, Sally, Moerch, Ulrik, Sandborn, William J. , Hibi∥, Toshifumi , Vermeire, Séverine , Loftus, Edward V.

Mayo Clinic

Posters | November 7, 2021 | Volume: No volume available | Issue: No issue available | Pages: A92.2-A92

10.1136/gutjnl-2021-bsg.169 Get It

OMO-3 Safety analysis of filgotinib for ulcerative colitis: Phase 2b/3 selection study and long-term extension results
Morison, Ben, Watanabe, Mamoru , Yun, Chohee , Zhao, Sally, Hsieh, Jeremy, Moerch, Ulrik, Schreiber, Stefan , Zhou, Yan, Rogler, Gerhard , Loftus, Edward V.

Mayo Clinic

Oral | November 7, 2021 | Volume: No volume available | Issue: No issue available | Pages: A6.1-A6

10.1136/gutjnl-2021-bsg.10 Get It

Incorporating Robustness to Imaging Physics into Radiomic Feature Selection for Breast Cancer Risk Estimation
Acciavatti, Raymond J. , Cohen, Eric A. , Gastounioti, Aimilia , Pantalone, Lauren , Vachon, Celine M. , Gastounioti, Aimilia , Vachon, Celine, Acciavatti, Raymond J , Maghsoudi, Omid Haji , Hsieh, Meng-Kang, Conant, Emily F. , Scott, Christopher G. , Winham, Stacey J. , Kerlikowske, Karla , Vachon, Celine M. , Maidment, Andrew D. A. , Kontos, Despina

Mayo Clinic

Cancers | November 1, 2021 | Volume: 13 | Issue: 21 | Pages: 5497

10.3390/cancers13215497 | PMID 34771660 Get It

Digital mammography has seen an explosion in the number of radiomic features used for risk-assessment modeling. However, having more features is not necessarily beneficial, as some features may be overly sensitive to imaging physics (contrast, noise, and image sharpness). To measure the effects of imaging physics, we analyzed the feature variation across imaging acquisition settings (kV, mAs) using an anthropomorphic phantom. We also analyzed the intra-woman variation (IWV), a measure of how much a feature varies between breasts with similar parenchymal patterns—a woman’s left and right breasts. From 341 features, we identified “robust” features that minimized the effects of imaging physics and IWV. We also investigated whether robust features offered better case-control classification in an independent data set of 575 images, all with an overall BI-RADS® assessment of 1 (negative) or 2 (benign); 115 images (cases) were of women who developed cancer at least one year after that screening image, matched to 460 controls. We modeled cancer occurrence via logistic regression, using cross-validated area under the receiver-operating-characteristic curve (AUC) to measure model performance. Models using features from the most-robust quartile of features yielded an AUC = 0.59, versus 0.54 for the least-robust, with p < 0.005 for the difference among the quartiles.
S604 The Evolving Practice of Water-Aided Colonoscopy (WAC) – An International Survey of Colonoscopists
Leung, Felix W. , Yen, Andrew W. , Groen, Piet de, Hsieh, Yu‐Hsi , Ishaq, Sauid , Ramirez, Francisco C. , Bak, Adrian, Karnes, William E., Bayupurnama, Putut , Leung, Joseph W., Cadoni, Sergio , Siau, Keith , Cheng, Chi‐Liang

Mayo Clinic

American Journal of Gastroenterology | October 24, 2021 | Volume: 116 | Issue: 1 | Pages: S274-S274

10.14309/01.ajg.0000775948.91478.0d Get It

An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
Gong, Hao , Hsieh, Scott S. , Holmes, David R. , Cook, David A. , Bartlett, David J. , Baffour, Francis , Takahashi, Hiroaki , Yu, Lifeng , Inoue, Akitoshi , Baffour, Francis I , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G. , Takahashi, Hiroaki

Mayo Clinic

Medical Physics | September 17, 2021 | Volume: 48 | Issue: 11 | Pages: 6710-6723

10.1002/mp.15219 | PMID 34534365 Get It

AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.
Deep learning enabled ultra‐fast‐pitch acquisition in clinical X‐ray computed tomography
Gong, Hao , Ren, Liqiang , Hsieh, Scott S. , Yu, Lifeng , Gong, Hao , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Medical Physics | August 20, 2021 | Volume: 48 | Issue: 10 | Pages: 5712-5726

10.1002/mp.15176 | PMID 34415068 Get It

AbstractObjectiveIn X‐raycomputed tomography (CT), many important clinical applications may benefit from a fast acquisition speed. The helical scan is the most widely used acquisition mode in clinical CT, where a fast helical pitch can improve the acquisition speed. However, on a typical single‐source helical CT (SSCT) system, the helical pitch p typically cannot exceed 1.5; otherwise, reconstruction artifacts will result from data insufficiency. The purpose of this work is to develop a deep convolutional neural network (CNN) to correct for artifacts caused by an ultra‐fast pitch, which can enable faster acquisition speed than what is currently achievable.MethodsA customized CNN (denoted as ultra‐fast‐pitch network (UFP‐net)) was developed to restore the underlying anatomical structure from the artifact‐corrupted post‐reconstruction data acquired from SSCT with ultra‐fast pitch (i.e., p ≥ 2). UFP‐net employed residual learning to capture the features of image artifacts. UFP‐net further deployed in‐house‐customized functional blocks with spatial‐domain local operators and frequency‐domain non‐local operators, to explore multi‐scale feature representation. Images of contrast‐enhanced patient exams (n = 83) with routine pitch setting (i.e., p < 1) were retrospectively collected, which were used as training and testing datasets. This patient cohort involved CT exams over different scan ranges of anatomy (chest, abdomen, and pelvis) and CT systems (Siemens Definition, Definition Flash, Definition AS+, Siemens Healthcare, Inc.), and the corresponding base CT scanning protocols used consistent settings of major scan parameters (e.g., collimation and pitch). Forward projection of the original images was calculated to synthesize helical CT scans with one regular pitch setting (p = 1) and two ultra‐fast‐pitch setting (p = 2 and 3). All patient images were reconstructed using the standard filtered‐back‐projection (FBP) algorithm. A customized multi‐stage training scheme was developed to incrementally optimize the parameters of UFP‐net, using ultra‐fast‐pitch images as network inputs and regular pitch images as labels. Visual inspection was conducted to evaluate image quality. Structural similarity index (SSIM) and relative root‐mean‐square error (rRMSE) were used as quantitative quality metrics.ResultsThe UFP‐net dramatically improved image quality over standard FBP at both ultra‐fast‐pitch settings. At p = 2, UFP‐net yielded higher mean SSIM (> 0.98) with lower mean rRMSE (< 2.9%), compared to FBP (mean SSIM < 0.93; mean rRMSE > 9.1%). Quantitative metrics at p = 3: UFP‐net—mean SSIM [0.86, 0.94] and mean rRMSE [5.0%, 8.2%]; FBP—mean SSIM [0.36, 0.61] and mean rRMSE [36.0%, 58.6%].ConclusionThe proposed UFP‐net has the potential to enable ultra‐fast data acquisition in clinical CT without sacrificing image quality. This method has demonstrated reasonable generalizability over different body parts when the corresponding CT exams involved consistent base scan parameters.
Improving digital charge sharing compensation in photon counting detectors with a low‐threshold comparator
Hsieh, Scott S. , Iniewski, Kris, Hsieh, Scott Sigao

Mayo Clinic

Medical Physics | August 9, 2021 | Volume: 48 | Issue: 10 | Pages: 5819-5829

10.1002/mp.15154 | PMID 34370321 Get It

AbstractPurposeCharge sharing is a major non‐ideality in photon counting detectors (PCDs) and can increase variance in material decomposition images. Analog charge summing (ACS) is an effective mechanism for charge sharing compensation (CSC), but is complex to implement and may limit the maximum count rate of the PCD. Digital CSC mechanisms such as digital count summing (DCS) may be simpler to implement; however, earlier simulation studies suggest that digital CSC only provides half the benefit of ACS. We propose including an additional low‐threshold comparator (LTC) underneath the noise floor of the PCD to improve the effectiveness of digital CSC.MethodsWe simulated a PCD with four or eight equally spaced energy bins. X‐ray photons arrived on the PCD following a Poisson distribution, and charge was allocated to PCD pixels following Monte Carlo techniques. Gaussian electronic noise was added with standard deviation of 2 keV and the signals were processed with four CSC schemes: no CSC, ACS, DCS, and DCS with LTC. The energy bins were placed from 25 to 100 keV at 25 keV intervals (for four bins) or from 25 to 112.5 keV at 12.5 keV intervals (for eight bins), and the LTC threshold was placed at 8 keV in both cases. The binned counts were transformed into estimates of water and iodine material thickness using a linear estimator that was fitted to the data. Our simulations were performed in the low‐flux limit without any pileup, assuming a 120 kVp spectrum, 25 cm water object, and 0.3 mm PCD pixel size.ResultsAll CSC schemes decreased variance in basis material decomposition. In the four‐bin PCD, the relative dose efficiencies (inverse of the variance) for iodine material decomposition were 1.0, 2.4, 3.2, and 4.3 for a PCD without CSC, DCS without LTC, DCS with LTC, and ACS, respectively. In the eight‐bin PCD, the relative dose efficiencies were 1.1, 2.5, 3.1, and 4.8, respectively. In a sensitivity analysis, electronic noise had a stronger deleterious effect on ACS than DCS. In simulated visual images, DCS and ACS improved high frequency contrast in material decomposition images.ConclusionsIntroducing an LTC may reduce the performance differential between DCS and ACS. These findings have been derived from simulation studies only and have not been validated experimentally.
Cf‐02, a novel benzamide‐linked small molecule, blunts NF‐κB activation and NLRP3 inflammasome assembly and improves acute onset of accelerated and severe lupus nephritis in mice
Yang, Shin‐Ruen , Yang, Chih‐Yu , Chen, Ann , Weng, Jui‐Chun, Wan, Chih‐Jun, Wu, Chung‐Yao, Lee, Chia‐Chung, Chan, Jia‐Feng, Hsu, Yu‐Juei , Wu, Chia‐Chao , Huang, Hsu‐Shan , Liu, Feng‐Cheng , Ka, Shuk‐Man , Chen, Ann , Huang, Hsu-Shan , Liu, Feng-Cheng , Ka, Shuk-Man , Hua, Kuo‐Feng , Weng, Jui‐Chun, Tsai, Yu‐Ling , Wu, Chung-Yao, Hsieh, Chih‐Yu , Mukhopadhyay, Debabrata

Mayo Clinic

The FASEB Journal | July 27, 2021 | Volume: 35 | Issue: 8 | Pages: No page available

10.1096/fj.202100047r | PMID 34314075 Get It

Abstract In the present study, acute onset of severe lupus nephritis was successfully treated in mice using a new, benzamide‐linked, small molecule that targets immune modulation and the NLRP3 inflammasome. Specifically, 6‐(2,4‐difluorophenyl)‐3‐(3‐(trifluoromethyl)phenyl)‐2H‐benzo[e][1,3]oxazine‐2,4(3H)‐dione (Cf‐02) (a) reduced serum levels of IgG anti‐dsDNA, IL‐1β, IL‐6, and TNF‐α, (b) inhibited activation of dendritic cells and differentially regulated T cell functions, and (c) suppressed the NF‐κB/NLRP3 inflammasome axis, targeting priming and activating signals of the inflammasome. Moreover, treatment with Cf‐02 significantly inhibited secretion of IL‐1β in lipopolysaccharide‐stimulated macrophages, but this effect was abolished by autophagy induction. These results recommend Cf‐02 as a promising drug candidate for the serious renal conditions associated with systemic lupus erythematosus. Future investigations should examine whether Cf‐02 may also be therapeutic in other types of chronic kidney disease involving NLRP3 inflammasome‐driven signaling.
DOP82 Corticosteroid-free remission of Ulcerative Colitis with filgotinib maintenance therapy: Post hoc analysis of the phase 2b/3 SELECTION study
Feagan, Brian G. , Yun, Chohee , Hsieh, Jeremy, Liu, X, Zhao, Sally, Moerch, Ulrik, Sandborn, William J. , Hibi∥, Toshifumi , Loftus, Edward V. , Vermeire, Séverine

Mayo Clinic

Journal of Crohn's and Colitis | May 28, 2021 | Volume: 15 | Issue: Supplement_1 | Pages: S112-S113

10.1093/ecco-jcc/jjab073.121 Get It

Abstract Background Filgotinib (FIL) is a once-daily, oral, preferential Janus kinase 1 inhibitor in development for the treatment of inflammatory bowel disease. FIL for the treatment of moderately to severely active ulcerative colitis (UC) was evaluated in the phase 2b/3 randomized, double-blind, placebo (PBO)-controlled SELECTION study (NCT02914522). Long-term use of corticosteroids (CS) is associated with significant side effects. The aim of this post hoc analysis was to assess the CS-sparing effects of FIL in the SELECTION study. Methods Patients (18–75 years old) with moderately to severely active UC were randomized (2:2:1) to receive FIL 100 mg (n = 564), FIL 200 mg (n = 507) or PBO (n = 280) once daily orally for up to 11 weeks (induction study). At week 11, FIL induction responders were rerandomized 2:1 to continue their induction FIL dose or to receive PBO (maintenance study). CS use was kept stable up to week 14, at which point mandatory CS tapering occurred. CS could be resumed during the maintenance study; however, if the baseline CS dose was exceeded this was considered treatment failure. In this post hoc analysis, CS-free remission was defined as remission at week 58 (endoscopic subscore ≤ 1, rectal bleeding subscore = 0 and ≥ 1-point decrease in stool frequency subscore to achieve 0 or 1) without systemic or localized CS use that was indicated for UC in the previous 1, 3, 6 or 8 months. Results The baseline characteristics of patients in the maintenance study were similar across treatment groups (Table 1). Of the 92 patients receiving CS at maintenance baseline (week 11; maintenance week 0) who received FIL 200 mg during the maintenance study, 25 (27%) were in remission at week 58 and had been continuously CS-free for at least the previous 6 months (Table 2). The proportion of CS-free remitters in the FIL 200 mg group was consistently higher than with PBO (Table 2). In patients taking CS at maintenance baseline who had continued CS-use post baseline, lower median prednisone dosing was observed with FIL 200 mg than with PBO throughout the maintenance study (maximum difference at week 34 [maintenance week 23]: 5.0 mg vs 13.8 mg) (Figure 1). In SELECTION, a total of 199 patients received FIL 200 mg in the maintenance study, of whom 74 (37.2%) were in remission at week 58; of these 74 patients, 69 (93.2%) were continuously CS-free for at least the previous 6 months (Figure 2). Conclusion In this post hoc analysis of SELECTION maintenance study data, FIL 200 mg was effective in reducing and eliminating CS use through to week 58 in patients with moderately to severely active UC. The vast majority of patients taking FIL 200 mg who were in remission at week 58 had not taken CS in the previous 6 months.