Citations

Clear

162 citation(s) found for "Fletcher, Joel G".

A deep learning‐ and partial least square regression‐based model observer for a low‐contrast lesion detection task in CT
Gong, Hao , Yu, Lifeng , Dilger, Samantha K. N. , Ren, Liqiang , Zhou, Wei , Dilger, Samantha K, Zhou, Wei , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | March 20, 2019 | Volume: 46 | Issue: 5 | Pages: 2052-2063

10.1002/mp.13500 | PMID 30889282 Get It

PurposeThis work aims to develop a new framework of image quality assessment using deep learning‐based model observer (DL‐MO) and to validate it in a low‐contrast lesion detection task that involves CT images with patient anatomical background.MethodsThe DL‐MO was developed using the transfer learning strategy to incorporate a pretrained deep convolutional neural network (CNN), a partial least square regression discriminant analysis (PLS‐DA) model and an internal noise component. The CNN was previously trained to achieve the state‐of‐the‐art classification accuracy over a natural image database. The earlier layers of the CNN were used as a deep feature extractor, with the assumption that similarity exists between the CNN and the human visual system. The PLSR model was used to further engineer the deep feature for the lesion detection task in CT images. The internal noise component was incorporated to model the inefficiency and variability of human observer (HO) performance, and to generate the ultimate DL‐MO test statistics. Seven abdominal CT exams were retrospectively collected from the same type of CT scanners. To compare DL‐MO with HO, 12 experimental conditions with varying lesion size, lesion contrast, radiation dose, and reconstruction types were generated, each condition with 154 trials. CT images of a real liver metastatic lesion were numerically modified to generate lesion models with four lesion sizes (5, 7, 9, and 11 mm) and three contrast levels (15, 20, and 25 HU). The lesions were inserted into patient liver images using a projection‐based method. A validated noise insertion tool was used to synthesize CT exams with 50% and 25% of routine radiation dose level. CT images were reconstructed using the weighted filtered back projection algorithm and an iterative reconstruction algorithm. Four medical physicists performed a two‐alternative forced choice (2AFC) detection task (with multislice scrolling viewing mode) on patient images across the 12 experimental conditions. DL‐MO was operated on the same datasets. Statistical analyses were performed to evaluate the correlation and agreement between DL‐MO and HO.ResultsA statistically significant positive correlation was observed between DL‐MO and HO for the 2AFC low‐contrast detection task that involves patient liver background. The corresponding Pearson product moment correlation coefficient was 0.986 [95% confidence interval (0.950, 0.996)]. Bland–Altman agreement analysis did not indicate statistically significant differences.ConclusionsThe proposed DL‐MO is highly correlated with HO in a low‐contrast detection task that involves realistic patient liver background. This study demonstrated the potential of the proposed DL‐MO to assess image quality directly based on patient images in realistic, clinically relevant CT tasks.
Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread
Glazebrook, Katrina N. , Doerge, Stefan, Drees, Tammy A., Hunt, Katie N. , Zingula, Shannon N. , Pruthi, Sandhya , Geske, Jennifer R. , Carter, Rickey E. , Carter, Rickey E , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Geske, Jennifer

Mayo Clinic

American Journal of Roentgenology | February 19, 2019 | Volume: 212 | Issue: 4 | Pages: 933-942

10.2214/ajr.18.20138 | PMID 30779664 Get It

Early Results of a Phase I Trial Using an Adipose-Derived Mesenchymal Stem Cell-Coated Fistula Plug for the Treatment of Transsphincteric Cryptoglandular Fistulas
Dozois, Eric J. , Mathis, Kellie L. , Chua, Heidi K, Dietz, Allan B. , Friton, Jessica, Butler, Greg W., Faubion, William A. , Kelley, Scott R. , Friton, Jessica J, Dietz, Allan B , Lightner, Amy L. , Fletcher, Joel G.

Mayo Clinic

Diseases of the Colon & Rectum | January 26, 2019 | Volume: 62 | Issue: 5 | Pages: 615-622

10.1097/dcr.0000000000001333 | PMID 30664554 Get It

BACKGROUND: Management of transsphincteric cryptoglandular fistulas remains a challenging problem and the optimal surgical approach remains elusive. Mesenchymal stem cells, increasingly being utilized for perianal Crohn’s disease, offer a novel therapy to treat cryptoglandular fistulas. OBJECTIVES: This study aimed to determine safety and feasibility of using an autologous mesenchymal stem cell-coated fistula plug in patients with transsphincteric cryptoglandular fistulas. DESIGN: This study is a phase I clinical trial. SETTING: This study was conducted at a tertiary academic medical center. PATIENTS: Adult (>18 years) male and female patients with transsphincteric cryptoglandular fistulas were selected. MAIN OUTCOMES MEASURES: The primary outcomes measured were the safety, feasibility, and efficacy of a mesenchymal stem cell-coated fistula plug in patients with transsphincteric fistulas. RESULTS: Fifteen patients (8 women, mean age 39.8 years) with a single-tract transsphincteric fistula received a mesenchymal stem cell-loaded fistula plug and were followed for 6 months. Duration of disease at the time of study enrollment was a median of 3.0 years (range, 1–13 years) with a median of 3.5 (range, 1–20) prior surgical interventions. Adverse events included 1 plug extrusion, 1 abdominal wall seroma, 3 perianal abscesses requiring drainage, and 1 patient with perianal cellulitis. There were no serious adverse events. At 6 months, 3 patients had complete clinical healing, 8 had partial healing, and 4 patients showed no clinical improvement. Radiographic improvement was seen in 11 of 15 patients. LIMITATIONS: This study was limited by the small cohort and short follow-up. CONCLUSIONS: Autologous mesenchymal stem cell-coated fistula plug treatment of transsphincteric cryptoglandular fistulas was safe and feasible and resulted in complete or partial healing in a majority of patients. See Video Abstract at http://links.lww.com/DCR/A897.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 | PMID 30562270 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines
Long, Zaiyang , Nagelschneider, Alex A. , Michalak, Gregory J. , Yu, Lifeng , DeLone, David R. , Kotsenas, Amy L. , Lehman, Vance T. , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

American Journal of Roentgenology | December 12, 2018 | Volume: 212 | Issue: 2 | Pages: 395-401

10.2214/ajr.18.19757 | PMID 30667317 Get It

Findings of CT-Derived Bone Strength Assessment in Inflammatory Bowel Disease Patients Undergoing CT Enterography in Clinical Practice
Maldonado, Francisco J., Al‐Bawardy, Badr , Nehra, Avinash , Lee, Yong S. , Bruining, David H. , Adkins, Mark C., Keaveny, Tony M. , Johnson, Matthew P. , Fidler, Jeff L. , Al Bawardy, Badr F, Nehra, Avinash K, Maldonado, Francisco J, Fidler, Jeff L. , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Inflammatory Bowel Diseases | November 26, 2018 | Volume: 25 | Issue: 6 | Pages: 1072-1079

10.1093/ibd/izy341 | PMID 30476314 Get It

High-Resolution Chest Computed Tomography Imaging of the Lungs
Bartlett, David J. , Koo, Chi Wan , Bartholmai, Brian J. , Weaver, Jayse , Halaweish, Ahmed F., Bartholmai, Brian J , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Investigative Radiology | November 21, 2018 | Volume: 54 | Issue: 3 | Pages: 129-137

10.1097/rli.0000000000000524 | PMID 30461437 Get It

Objectives The aim of this study was to evaluate if a high-resolution photon-counting detector computed tomography (PCD-CT) system with a 1024×1024 matrix reconstruction can improve the visualization of fine structures in the lungs compared with conventional high-resolution CT (HRCT). Materials and Methods Twenty-two adult patients referred for clinical chest HRCT (mean CTDI vol, 13.58 mGy) underwent additional dose-matched PCD-CT (mean volume CT dose index, 13.37 mGy) after written informed consent. Computed tomography images were reconstructed at a slice thickness of 1.5 mm and an image increment of 1 mm with our routine HRCT reconstruction kernels (B46 and Bv49) at 512 and 1024 matrix sizes for conventional energy-integrating detector (EID) CT scans. For PCD-CT, routine B46 kernel and an additional sharp kernel (Q65, unavailable for EID) images were reconstructed at 1024 matrix size. Two thoracic radiologists compared images from EID and PCD-CT noting the highest level bronchus clearly identified in each lobe of the right lung, and rating bronchial wall conspicuity of third- and fourth-order bronchi. Lung nodules were also compared with the B46/EID/512 images using a 5-point Likert scale. Statistical analysis was performed using a Wilcoxon signed rank test with a P < 0.05 considered significant. Results Compared with B46/EID/512, readers detected higher-order bronchi using B46/PCD/1024 and Q65/PCD/1024 images for every lung lobe (P < 0.0015), but in only the right middle lobe for B46/EID/1024 (P = 0.007). Readers were able to better identify bronchial walls of the third- and fourth-order bronchi better using the Q65/PCD/1024 images (mean Likert scores of 1.1 and 1.5), which was significantly higher compared with B46/EID/1024 or B46/PCD/1024 images (mean difference, 0.8; P < 0.0001). The Q65/PCD/1024 images had a mean nodule score of 1 ± 1.3 for reader 1, and −0.1 (0.9) for reader 2, with one reader having improved nodule evaluation scores for both PCD kernels (P < 0.001), and the other reader not identifying any increased advantage over B46/EID/1024 (P = 1.0). Conclusions High-resolution lung PCD-CT with 1024 image matrix reconstruction increased radiologists' ability to visualize higher-order bronchi and bronchial walls without compromising nodule evaluation compared with current chest CT, creating an opportunity for radiologists to better evaluate airway pathology.
Imaging and Surgical Management of Anorectal Vaginal Fistulas
VanBuren, Wendaline M. , Kim, Sarasa T. , Sheedy, Shannon P. , Woolever, Madeline C., Menias, Christine O. , Fletcher, Joel G. , Fletcher, Joel G , Lightner, Amy L.

Mayo Clinic

RadioGraphics | September 12, 2018 | Volume: 38 | Issue: 5 | Pages: 1385-1401

10.1148/rg.2018170167 | PMID 30207932 Get It

Detection and Characterization of Renal Stones by Using Photon-Counting–based CT
Marcus, Roy , Fletcher, Joel G. , Ferrero, Andrea , Leng, Shuai , Halaweish, Ahmed F., Gutjahr, Ralf , Vrtiska, Terri J., Wells, Mike L., McCollough, Cynthia H. , Marcus, Roy P, Enders, Felicity T, McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Enders, Felicity

Mayo Clinic

Radiology | August 7, 2018 | Volume: 289 | Issue: 2 | Pages: 436-442

10.1148/radiol.2018180126 | PMID 30084728 Get It