Citations

Clear

137 citation(s) found for "Fatemi, Mostafa".

A new imaging technique based on resonance for arterial vessels
Zhang, Xiaoming , Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 21, 2013 | Volume: 113 | Issue: 4_Supplement | Pages: 2239-2239

10.1121/1.4780366 Get It

Vibro-acoustography is a new noncontact imaging method based on the radiation force of ultrasound. We extend this technique for imaging of arterial vessels based on vibration resonance. The arterial vessel is excited remotely by ultrasound at a resonant frequency, at which the vibration of the vessel as well as its transmission to the body surface are large enough to be measured. By scanning the ultrasound beam across the vessel plane and measuring the vibration at one single point on the body or vessel surface, an image of the interior artery can be mapped. Theory is developed that predicts the measured velocity is proportional to the value of the mode shape at resonance. Experimental studies were carried out on a silicone tube embedded in a cylindrical gel phantom of large radius, which simulates a large artery and the surrounding body. The fundamental frequency was measured at which the ultrasound transducer scanned across the tube plane with velocity measurement at one single point on the tube or on the phantom by laser. The images obtained show clearly the interior tube and the modal shape of the tube. The present technique offers a new imaging method for arterial vessels.
A vibration model for frequency analysis of arterial tubes with tissue
Zhang, Xiaoming , Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 21, 2013 | Volume: 113 | Issue: 4_Supplement | Pages: 2239-2239

10.1121/1.4780365 Get It

Vibro-acoustography is a new noncontact imaging method based on the radiation force of ultrasound. We extend this technique for tissue characterization of arterial tubes by vibration techniques. The arterial tube can be excited remotely by ultrasound at its resonant frequencies where the vibration and acoustic emission of the tube can be measurable. From these resonant frequencies, the material properties of the arterial tube can be found. A theory for a tube with tissue is formulated using first-order shear deformation theory to include the effects of transverse shear deformation and rotary inertia. A wave propagation approach is applied for easy handling of the boundary conditions. Experimental studies were carried out on a silicone tube embedded in a cylindrical gel phantom. A confocal transducer is used to produce the radiation force of ultrasound for exciting the tube–phantom structure. The vibration of the tube and the phantom are measured with a laser vibrometry system. The fundamental mode of a tube–phantom structure is well excited by the radiation force of ultrasound, and was measured to be 81.8 Hz, which is close to the theoretical prediction of 83.3 Hz. Both excitation and measurement are remote and noncontact, important attributes for future study of arteries.
Vibro-acoustography: The sound of tissue
Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 21, 2013 | Volume: 113 | Issue: 4_Supplement | Pages: 2237-2237

10.1121/1.4780359 Get It

Palpation is routinely used for detecting pathology using the stiffness of the tissue and is more than 2000 years old. Palpation is subjective and limited to individual experience and to the accessibility of the tissue region to touch. Noninvasive images of elastic modulus may be useful to distinguish tissues and pathologic processes based on mechanical properties such as elastic modulus. Static, quasistatic, or cyclic stresses have been applied while strains have been measured using ultrasound or MRI. The related elastic modulus has been estimated from visco-elastic models of tissue mechanics. Recently we have developed a new ultrasound technique that produces speckle free images related to both tissue stiffness and reflectivity. This method, termed Ultrasound Stimulated Vibro-acoustography [Science 280, 83–85 (1998); PNAS 96, 6603–6608 (1999)], uses ultrasound radiation pressure to produce sound vibrations from a small region of the tissue that depend on the scattering and elastic characteristics of the tissue. The method can detect microcalcification within breasts, and promises to provide high-quality images of calcification within the arteries. Vibro-acoustography can detect mechanical defects in prostheses such as artificial mitral and aortic valves. The method may also be used in nondestructive evaluation. [Work supported by HL 61451, DBI 7980-4.]
Coupled vibration analysis of large arterial vessels
Greenleaf, James F., Zhang, Xiaoming , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 18, 2013 | Volume: 111 | Issue: 5_Supplement | Pages: 2443-2444

10.1121/1.4778407 Get It

A coupled vibration model, which takes into account the elastic arterial wall, the interior blood, and exterior tissue, is presented. The arterial wall is considered as a cylindrical elastic shell and is modeled with the thick shell theory due to the large thickness-to-radius ratios. Both the blood and the tissue are considered as ideal fluids and are modeled with acoustic wave theory. A newly developed method, the wave propagation approach, is extended for the coupled vibration of arterial walls. The theoretic model is evaluated against those available in the literature. The experiments were carried out on a silicone rubber tube in a water tank with an ultrasound stimulated system. This system uses the radiation force of ultrasound to vibrate the tube at low frequency and records the resulting response by a laser vibrometer. Both the excitation and measurement are remote and noncontact. The measured fundamental frequency is in good agreement with the theoretical prediction.
Imaging Errors in Localization of COMS-Type Plaques in Choroidal Melanoma Brachytherapy
Bayat, Mahdi , Tamminga, Rachel, Pulido, José S. , Fatemi, Mostafa , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

Investigative Opthalmology & Visual Science | September 20, 2013 | Volume: 54 | Issue: 10 | Pages: 6852

10.1167/iovs.12-11499 | PMID 24052637 Get It

Noncontact modal analysis of a pipe organ reed using airborne ultrasound stimulated vibrometry
Huber, Thomas M. , Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | September 9, 2013 | Volume: 115 | Issue: 5_Supplement | Pages: 2450-2450

10.1121/1.4782223 Get It

The goal of this experiment was to excite and measure, in a noncontact manner, the vibrational modes of the reed from a reed organ pipe. To perform ultrasound stimulated excitation, two ultrasound beams in air of different frequencies were directed at the reed; the audio-range beat frequency between these ultrasound beams induced vibrations. The resulting vibrational deflection shapes were measured with a scanning vibrometer. The modes of any relatively small object can be studied in air using this technique. For a 36 mm by 7 mm clamped brass reed cantilever, displacements and velocites of 5 μ and 4 mm/s could be imparted at the fundamental frequency of 145 Hz. Using the same ultrasound transducer, excitation across the entire range of audio frequencies was obtained, which was not possible using audio excitation with a speaker. Since the beam was focused on the reed, ultrasound stimulated excitation eliminated background effects observed during mechanical shaker excitation, such as vibrations of clamps and supports. We will discuss the results obtained using single, dual, and confocal ultrasound transducers in AM and unmodulated CW modes, along with results obtained using a mechanical shaker and audio excitation using a speaker.
Noninvasive evaluation of complex elastic modulus of arterial vessels by ultrasound
Greenleaf, James F., Zhang, Xiaoming , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | September 9, 2013 | Volume: 115 | Issue: 5_Supplement | Pages: 2412-2412

10.1121/1.4781145 Get It

Pulse wave velocity (PWV) is widely used for estimating the stiffness of an artery. It is well known that a stiffened artery can be associated with disease and aging. Usually, PWV is measured using the foot-to-foot time-delay method. However, the foot of the pulse wave cannot be accurately determined due to reflected waves. In addition, PWV is an average indicator of artery stiffness between the two measuring points. We propose to generate a wave in the artery wall using localized ultrasound radiation force. The wave velocity can be measured accurately by the phase change versus distance over a few millimeters. A mathematical model is developed by which the real part of the complex Young’s modulus of the artery can be determined from measured wave velocities. The imaginary part of the complex modulus can be assessed by the wave amplitude decay over distance. Experiments were conducted on a pig carotid artery in gelatin. The measured wave velocity is about 3 m/s at 100 Hz and 6.5 m/s at 500 Hz. The real part of complex modulus is estimated to be 300 kPa. The present technique offers a new method for estimating the complex elastic modulus of the artery over a short length.
Application of Topological Sensitivity Toward Soft-Tissue Characterization From Vibroacoustography Measurements
Yuan, Huina , Guzina, Bojan B. , Chen, Shigao , Kinnick, Randall R., Fatemi, Mostafa , Fatemi, Mostafa

Mayo Clinic

Journal of Computational and Nonlinear Dynamics | March 23, 2013 | Volume: 8 | Issue: 3 | Pages: No page available

10.1115/1.4023738 Get It

This study concerns the development and preliminary experimental verification of a topological sensitivity–based platform for the material characterization of tissue anomalies exposed by vibroacoustography-type imaging techniques. Vibroacoustography (VA) is a high-resolution imaging method that has been applied to the detection of pathological changes in soft tissues. Although the data provided by this method is related to the mechanical properties of tissue, the viscoelastic parameters of the object cannot be estimated by this imaging method itself. Topological sensitivity (TS) method is a data processing methodology that can be used to estimate the viscoelastic parameters of an object from vibration data. In this study, the concept of topological sensitivity is applied to interpret the vibroacoustography measurements for the purpose of lesion characterization. In the proposed approach, the topological sensitivity function, which signifies the variation of a given cost functional when an infinitesimal inclusion with trial material parameters is placed at the location of a point force, is formulated in terms of the adjoint field. The effectiveness of the resulting formula as a material indicator for lesion characterization is demonstrated by estimating the relative elastic parameters of a well-controlled neoprene sphere embedded in a tissue-mimicking phantom specimen.
Application of Radiation Force in Noncontact Measurement of the Elastic Parameters
Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

Ultrasonic Imaging | March 2, 2013 | Volume: 21 | Issue: 2 | Pages: 147-154

10.1177/016173469902100205 | PMID 10485567 Get It

Ultrasound-stimulated vibro-acoustic spectrography is a recently-developed method that employs the radiation force of two intersecting continuous ultrasound beams to remotely vibrate an object at an arbitrary low frequency. Object vibration produces a sound field (acoustic emission) in the medium, which is a function of object mechanical properties. By measuring the acoustic emission field, one can obtain information about the mechanical parameters of the object. In this paper, we use this method for remote (noncontact) measurement of the dynamic Young's modulus of a rod based on its fundamental resonance frequency. Experimental results on an aluminum rod agree with the published data.
Spectral Normalization for Ultrasonic Contrast Microbubble Detection
Chen, Shigao , McMahon, Eileen M. , Greenleaf, James F. , Bëlohlávek, Marek , Fatemi, Mostafa

Mayo Clinic

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 3 | Pages: 150-162

10.1177/016173460402600302 | PMID 15754796 Get It

Ultrasonic contrast agents consisting of microbubbles are used to assess tissue perfusion. The microbubbles are highly reflective and nonlinear and thus produce harmonics that are stronger than those from tissues. However, the magnitude of harmonic signals resulting from a region with microbubbles also depends on the acoustic pressure of incident ultrasound and the attenuation of intervening tissues in the ultrasound path. Therefore, the harmonic magnitude, as used in traditional harmonic imaging, may not be a reliable indicator of the presence or absence of microbubbles, and hence, tissue perfusion. To compensate for these effects, we present two parameters defined as the ratio of the harmonic to the fundamental component ( HFR) and the ratio of the harmonic to squared fundamental ( HSFR). A simplified model is used to illustrate the usefulness of these two parameters. Experiments show that both parameters improve detection of microbubbles and that HSFR performs better than HFR.