Objectives: To evaluate mechanical treatment failure in a large patient cohort sustaining a distal femur fracture treated with a distal femoral locking plate (DFLP). Design: This retrospective case–control series evaluated mechanical treatment failures of DFLPs. Setting: The study was conducted at 8 Level I trauma centers from 2010 to 2017. Patients and Participants: One hundred one patients sustaining OTA/AO 33-A and C distal femur fractures were treated with DFLPs that experienced mechanical failure. Intervention: The intervention included the treatment of a distal femur fracture with a DFLP, affected by mechanical failure (implant failure by loosening or breakage). Main Outcome Measure: The main outcome measures included injury and DFLP details; modes and timing of failure were studied. Results: One hundred forty-six nonunions were found overall (13.4%) including 101 mechanical failures (9.3%). Failures occurred in different manners, locations, and times depending on the DFLPs. For example, 33 of 101 stainless steel (SS) plates (33%) failed by bending or breaking in the working length, whereas no Ti plates failed here ( P < 0.05). Eleven of 12 failures with titanium-Less Invasive Stabilization System (92%) occurred by lost shaft fixation, mostly by the loosening of unicortical screws (91%). Sixteen of 44 variable –angled–LCP failures (36%) occurred at the distal plate–screw junction, whereas only 5 of 61 other DFLPs (8%) failed this way ( P < 0.05). Distal failures occurred on average at 23.7 weeks compared with others that occurred at 38.4 weeks ( P < 0.05). Variable –angled–LCP distal screw–plate junction failures occurred earlier (mean 21.4 weeks). Conclusion: Nonunion and mechanical failure occurred in 14% and 9% of patients, respectively, in this large series of distal femur fracture treated with a DFLP. The mode, location, presence of a prosthesis, and timing of failure varied depending on the characteristics of DFLP. This information should be used to optimize implant usage and design to prolong the period of stable fixation before potential implant failures occur in patients with a prolonged time to union. Level of Evidence: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Exploring the Biological and Physical Basis of Boron Neutron Capture Therapy (BNCT) as a Promising Treatment Frontier in Breast Cancer
BNCT is a high LET radiation therapy modality that allows for biologically targeted radiation delivery to tumors while reducing normal tissue impacts. Although the clinical use of BNCT has largely been limited to phase I/II trials and has primarily focused on difficult-to-treat malignancies such as recurrent head and neck cancer and recurrent gliomas, recently there has been a renewed interest in expanding the use of BNCT to other disease sites, including breast cancer. Given its high LET characteristics, its biologically targeted and tumor specific nature, as well as its potential for use in complex treatment settings including reirradiation and widespread metastatic disease, BNCT offers several unique advantages over traditional external beam radiation therapy. The two main boron compounds investigated to date in BNCT clinical trials are BSH and BPA. Of these, BPA in particular shows promise in breast cancer given that is taken up by the LAT-1 amino acid transporter that is highly overexpressed in breast cancer cells. As the efficacy of BNCT is directly dependent on the extent of boron accumulation in tumors, extensive preclinical efforts to develop novel boron delivery agents have been undertaken in recent years. Preclinical studies have shown promise in antibody linked boron compounds targeting ER/HER2 receptors, boron encapsulating liposomes, and nanoparticle-based boron delivery systems. This review aims to summarize the physical and biological basis of BNCT, the preclinical and limited clinical data available to date, and discuss its potential to be utilized for the successful treatment of various breast cancer disease states.
On the calculation of the relative biological effectiveness of ion radiation therapy using a biological weighting function, the microdosimetric kinetic model (MKM) and subsequent corrections (non-Poisson MKM and modified MKM)
Abstract Objective . To investigate similarities and differences in the formalism, processing, and the results of relative biological effectiveness (RBE) calculations with a biological weighting function (BWF), the microdosimetric kinetic model (MKM) and subsequent modifications (non-Poisson MKM, modified MKM). This includes: (a) the extension of the V79-RBE 10% BWF to model the RBE for other clonogenic survival levels; (b) a novel implementation of MKMs as weighting functions; (c) a benchmark against Chinese Hamster lung fibroblast (V79) in vitro data; (d) a study on the effect of pre- or post- processing the average biophysical quantities used for the RBE calculations; (e) a possible modification of the modified MKM parameters to improve the model accuracy at high linear energy transfer (LET). Methodology . Lineal energy spectra were simulated for two spherical targets (diameter = 0.464 or 1.0 μ m) using PHITS for 1 H, 4 He, 12 C, 20 Ne, 40 Ar, 56 Fe and 132 Xe ions. The results of the in silico calculations were compared with published in vitro data. Main results . All models appear to underestimate the RBE α of hydrogen ions. All MKMs generally overestimate the RBE 50% , RBE 10% and RBE 1% for ions with an LET greater than ∼200 keV μ m −1 . This overestimation is greater for small surviving fractions and is likely due to the assumption of a radiation-independent quadratic term of clonogenic survival ( ß ). The overall RBE trends seem to be best described by the novel ‘post-processing average’ implementation of the non-Poisson MKM. In case of calculations with the non-Poisson MKM, pre- or post- processing the average biophysical quantities affects the computed RBE values significantly. Significance . This study presents a systematic analysis of the formalism and results of widely used microdosimetric models of clonogenic survival for ions relevant for cancer particle therapy and space radiation protection. Points for improvements were highlighted and will contribute to the development of upgraded biophysical models.
Patient-specific deep learning model to enhance 4D-CBCT image for radiomics analysis
Abstract Objective. 4D-CBCT provides phase-resolved images valuable for radiomics analysis for outcome prediction throughout treatment courses. However, 4D-CBCT suffers from streak artifacts caused by under-sampling, which severely degrades the accuracy of radiomic features. Previously we developed group-patient-trained deep learning methods to enhance the 4D-CBCT quality for radiomics analysis, which was not optimized for individual patients. In this study, a patient-specific model was developed to further improve the accuracy of 4D-CBCT based radiomics analysis for individual patients. Approach. This patient-specific model was trained with intra-patient data. Specifically, patient planning 4D-CT was augmented through image translation, rotation, and deformation to generate 305 CT volumes from 10 volumes to simulate possible patient positions during the onboard image acquisition. 72 projections were simulated from 4D-CT for each phase and were used to reconstruct 4D-CBCT using FDK back-projection algorithm. The patient-specific model was trained using these 305 paired sets of patient-specific 4D-CT and 4D-CBCT data to enhance the 4D-CBCT image to match with 4D-CT images as ground truth. For model testing, 4D-CBCT were simulated from a separate set of 4D-CT scan images acquired from the same patient and were then enhanced by this patient-specific model. Radiomics features were then extracted from the testing 4D-CT, 4D-CBCT, and enhanced 4D-CBCT image sets for comparison. The patient-specific model was tested using 4 lung-SBRT patients’ data and compared with the performance of the group-based model. The impact of model dimensionality, region of interest (ROI) selection, and loss function on the model accuracy was also investigated. Main results. Compared with a group-based model, the patient-specific training model further improved the accuracy of radiomic features, especially for features with large errors in the group-based model. For example, the 3D whole-body and ROI loss-based patient-specific model reduces the errors of the first-order median feature by 83.67%, the wavelet LLL feature maximum by 91.98%, and the wavelet HLL skewness feature by 15.0% on average for the four patients tested. In addition, the patient-specific models with different dimensionality (2D versus 3D) or loss functions (L1 versus L1 + VGG + GAN) achieved comparable results for improving the radiomics accuracy. Using whole-body or whole-body+ROI L1 loss for the model achieved better results than using the ROI L1 loss alone as the loss function. Significance. This study demonstrated that the patient-specific model is more effective than the group-based model on improving the accuracy of the 4D-CBCT radiomic features analysis, which could potentially improve the precision for outcome prediction in radiotherapy.
RBE‐weighted dose and its impact on the risk of acute coronary event for breast cancer patients treated with intensity modulated proton therapy
AbstractPurposeTo evaluate the relative biological effectiveness (RBE)‐weighted dose to the heart and to estimate RBE uncertainties when assuming a constant RBE of 1.1, for breast cancer patients receiving intensity‐modulated proton therapy (IMPT). Further, to study the impact of RBE uncertainties on the risk of an acute coronary event (ACE).Material and methodsWe analyzed 20 patients who received IMPT to either the left breast (n = 10) or left chest wall (n = 10) and regional lymph nodes. The Monte Carlo simulation engine, MCsquare, was used to simulate the dose‐averaged linear energy transfer (LETd) map. The RBE‐weighted dose to the heart and its substructures was calculated using three different RBE models. The risk of ACE was estimated per its linear relationship with mean heart dose (MHD) as established by Darby et al.ResultsThe median MHD increased from 1.33 GyRBE assuming an RBE of 1.1 to 1.64, 1.87, and 1.99 GyRBE when using the RBE‐weighted dose models. The median values (and ranges) of the excess absolute risk of ACE were 0.4% (0.1%–0.8%) when assuming an RBE of 1.1, and 0.6% (0.2%–1.0%), 0.6% (0.2%–1.1%), and 0.7% (0.2%–1.1%) with the RBE‐weighted models. For our patient cohort, the maximum excess absolute risk of ACE increased by 0.3% with the RBE‐weighted doses compared to the constant RBE of 1.1, reaching an excess absolute ACE risk of 1.1%. The interpatient LETd variation was small for the relevant high‐dose regions of the heart.ConclusionAll three RBE models predicted a higher biological dose compared to the clinical standard dose assuming a constant RBE of 1.1. An underestimation of the biological dose results in underestimation of the ACE risk. Analyzing the voxel‐by‐voxel biological dose and the LET map alongside clinical outcomes is warranted in the development of a more accurate normal‐tissue complication probability model.
Metabolic Syndrome and Acute Respiratory Distress Syndrome in Hospitalized Patients With COVID-19
AbstractIntroductionThis study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity‐modulated proton therapy (IMPT).MethodsA stand‐alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat‐V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient‐specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A “table junction‐to‐CT‐origin” (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices.ResultsThe Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020.ConclusionA highly efficient patient‐specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution.
Clinico-Epidemiological Features of Elderly Patients with Peripheral T-Cell Lymphoma Not Otherwise Specified: A Study from the Grupo De Estudio Latinoamericano De Linfoproliferativos (GELL)
Abstract Introduction: Peripheral T-cell lymphoma not otherwise specified (PTCL-NOS) is the most common PTCL subtype, accounting for approximately 25% of all PTCL cases. The median age at diagnosis is 60 years and is more prevalent among males. Currently, most epidemiological data on T- and NK-cell lymphomas come from developed countries. Thus, very few data are available regarding this condition in Latin American countries, especially in those aged 60 years and older. The Latin American Group of Lymphoproliferative Disorders (GELL) has previously reported on the impact of serum albumin level in survival outcomes in PTCL-NOS. Therefore, we aim to evaluate the clinical, demographic, and outcome patterns of elderly patients with PTCL-NOS. Methods: We conducted an observational, retrospective study of newly diagnosed PTCL-NOS between January 2000 and December 2020. Patient must be aged 60 years and older. All clinical data were retrieved from clinical records at the different participating institutions. The study outcomes were overall survival (OS) and progression-free survival (PFS). The International Prognostic Index (IPI), the Prognostic Index for T-cell lymphoma (PIT), and the NCCN IPI scores were used for risk stratification. Kaplan-Meier and log-rank test were used for survival analysis. Univariate and multivariate Cox regression analysis were used to estimate hazard ratios (HR) with a 95% confidence interval (CI). Outcomes with a p-value <0.05 were considered statistically significant. Results: A total of 107 patients were included; median age at diagnosis was 72 years (range 60-92), 61% were male, 46% had an ECOG ≥2, 70% had stage III-IV, and 15% had more than one extranodal site. The IPI, PIT and NCCN-IPI scores stratified 51%, 69%, and 74% of patients as high- / high-intermediate risk, respectively. Seventy-four (69%) patients received first-line systemic therapy. Most patients (53%) were managed with CHOP/CHOP-like regimen, followed by CHOEP (19%). The overall response (OR) rate to first-line therapy was 61% (complete response, CR 41%). Salvage therapy was given to only 9 patients; the OR rate was 44% (CR 11%). With a median follow-up of 29 months (95% CI 13-45 months), the 2-year OS was 46% (95% CI 36-59), with median survival time of 16 months (95% CI 10-NR). In the multivariate analysis, patients with serum albumin levels <3.5 g/dL had median survival of 7 months (95% CI 3-20) and 2-year OS rate of 24% (95% CI 13-46%), while patients with albumin ≥3.5 g/dL did not reach the median survival time and had a 2-yOS rate of 67% (95% CI 36-65%) (p<0.0001) (Table 1, Figure 1). Patients with a lymphocyte-to-monocyte ratio (LMR) >7.6 had a median OS of 8 months (95% CI 6-NR) and a 2-year OS of 10% (95% CI 2-65), while patients with a LMR ≤7.6 did not reach the median OS and had a 2-year OS of 57% (95% CI 45-72) (p = 0.0108) (Table 1, Figure 1). Conclusions: This large cohort of Latin American PTCL-NOS patients aged ≥60 years showed overall response rates comparable to previously published data. However, survival rates were shorter compared to those reported in developed countries. In this study, we again confirmed low serum albumin level (<3.5 g/dL) as an adverse prognostic factor for OS in PTCL-NOS, and independent from the IPI, PIT and NCCN-IP scores. Additionally, we describe for first time in a Latin American cohort the impact of the LMR on survival, demonstrating poor outcomes in those with LMR >7.6. We are currently validating our findings in a prospective cohort of Latin American PTCL patients and to improve clinical decision-making in those deemed at high-risk for early mortality. Figure 1 Figure 1. Disclosures Otero: Astra Zeneca: Current Employment. Castillo: Abbvie: Consultancy, Research Funding; BeiGene: Consultancy, Research Funding; Pharmacyclics: Consultancy, Research Funding; Janssen: Consultancy; Roche: Consultancy; TG Therapeutics: Research Funding.
Risk Factors and Time to Clinical Symptoms of Multiple Sclerosis Among Patients With Radiologically Isolated Syndrome
AbstractIrritable bowel syndrome (IBS) is a gut‐brain disorder in which symptoms are shaped by serotonin acting centrally and peripherally. The serotonin transporter gene SLC6A4 has been implicated in IBS pathophysiology, but the underlying genetic mechanisms remain unclear. We sequenced the alternative P2 promoter driving intestinal SLC6A4 expression and identified single nucleotide polymorphisms (SNPs) that were associated with IBS in a discovery sample. Identified SNPs built different haplotypes, and the tagging SNP rs2020938 seems to associate with constipation‐predominant IBS (IBS‐C) in females. rs2020938 validation was performed in 1978 additional IBS patients and 6,038 controls from eight countries. Meta‐analysis on data from 2,175 IBS patients and 6,128 controls confirmed the association with female IBS‐C. Expression analyses revealed that the P2 promoter drives SLC6A4 expression primarily in the small intestine. Gene reporter assays showed a functional impact of SNPs in the P2 region. In silico analysis of the polymorphic promoter indicated differential expression regulation. Further follow‐up revealed that the major allele of the tagging SNP rs2020938 correlates with differential SLC6A4 expression in the jejunum and with stool consistency, indicating functional relevance. Our data consolidate rs2020938 as a functional SNP associated with IBS‐C risk in females, underlining the relevance of SLC6A4 in IBS pathogenesis.