Citations

Clear

212 citation(s) found for "McCollough, Cynthia H".

Improved Visualization of Middle Ear Prostheses using Photon-Counting Detector CT: A Cadaver Study
Sadeghian, Maryam, Benson, John C. , Lane, John I. , Treb, Kevin , Khandalavala, Karl R. , Babajanian, Eric E. , Bruesewitz, Michael R. , Swicklik, Joseph R., Ou, Fang‐Shu , McCollough, Cynthia H, Carlson, Matthew L, Leng, Shuai, Ou, Fang-Shu , Sadeghian, Maryam , Farnsworth, Paul J. , McCollough, Cynthia H. , Carlson, Matthew L. , Leng, Shuai

Mayo Clinic

Radiology Advances | September 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/radadv/umag041 Get It

Abstract Background Evaluation of middle ear prostheses requires high-resolution imaging to assess position and structural integrity. Purpose To assess the diagnostic performance of photon-counting-detector (PCD)-CT for middle ear prosthesis imaging in cadaveric specimens. Materials and Methods Nine different middle ear prostheses were implanted in five fresh-frozen whole-head specimens, both in correct anatomic position and displaced to mimic malposition. Specimens were scanned on PCD-CT (NAEOTOM Alpha, Siemens) and energy-integrating-detector (EID)-CT (SOMATOM Force, Siemens), reconstructed at 0.2mm and 0.4mm, respectively. Eighteen cases (9 prostheses, 2 positions) per scanner were evaluated by two neuroradiologists (36 readings), blinded to scanner and position, who scored prosthesis position, reader confidence, and overall image quality. Agreement with the reference standard and between readers was compared. Results PCD-CT showed higher diagnostic confidence compared with EID-CT, while accuracy and inter-reader agreement did not demonstrate significant differences between scanners. Correct readings, PCD-CT versus EID-CT: lateral contact, 31/36 (86.1%; 95% CI: 58.3%-94.4%) vs. 29/36 (80.6%; 55.6%-91.7%), p = 0.500; medial contact, 30/36 (83.3%; 55.6%-94.4%) vs. 26/36 (72.2%; 50.0%-83.3%), p = 0.250. PCD-CT identified all cases of complete contact loss (score 3), while EID-CT missed one reading per contact. Inter-reader agreement may be higher with PCD-CT vs EID-CT (lateral: κw: 0.804 [0.578-0.941] vs. 0.571 [0.302-0.778], p = 0.250; medial: 0.684 [0.191-0.934] vs. 0.481 [0.024-0.835], p = 0.250). Reader confidence was significantly higher with PCD-CT; mean paired differences for Readers 1 and 2 were 9.4 (1.8-17.1; Holm-adjusted p = 0.019) and 23.1 points (13.4-32.7; p < 0.001) for lateral contact, and 16.4 (10.0-22.8; p < 0.001) and 17.8 points (6.8-28.8; p = 0.007) for medial contact. Readers preferred PCD-CT image quality in 16/18 (88.9%; 65.3%-98.6%) and 17/18 cases (94.4%; 72.7%-99.9%), respectively. Conclusion PCD-CT was associated with significantly higher reader confidence and preferred image quality, without significant differences in diagnostic accuracy or inter-reader agreement. These findings suggest PCD-CT is a promising modality for postoperative middle ear evaluations that warrants further investigations.
Model-based motion simulation framework for deep learning-assisted motion correction in dynamic wrist CT
Zhao, Kristin D. , Treb, Kevin , Gu, Chunming , Davis, Aeden K , Huang, Shengbing, Treb, Kevin , Trentadue, Taylor P , Sadeghian, Maryam , Baffour, Francis , Trentadue, Taylor P , Leng, Shuai , Gong, Hao , Gu, Chunming , Thoreson, Andrew R. , Lachman, Nirusha , Baffour, Francis, Trentadue, Taylor P. , Kakar, Sanjeev , McCollough, Cynthia H, Leng, Shuai , Gong, Hao

Mayo Clinic

Physics in Medicine & Biology | September 11, 2026 | Volume: 71 | Issue: 18 | Pages: 185014

10.1088/1361-6560/aea684 | PMID 42727609 Get It

Abstract Objective. Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted ( α = 0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference ( p > 0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55 ± 0.12–0.75 ± 0.04 and SSIM from 0.87 ± 0.08–0.95 ± 0.03 at bone regions (each p < 0.01). In experimental cadaveric scans, LIRS improved from 0.05 ± 0.01–0.31 ± 0.17 in marker regions and from 0.58 ± 0.19–0.77 ± 0.14 in bone regions (each p < 0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement.
Good News about CT Doses
McCollough, Cynthia H. , McCollough, Cynthia H

Mayo Clinic

Radiology | July 28, 2026 | Volume: 320 | Issue: 1 | Pages: No page available

10.1148/radiol.261781 | PMID 42517767 Get It

The Uncoupling of CT Dose and Noise
McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H , Leng, Shuai , Yu, Lifeng

Mayo Clinic

Radiology | May 12, 2026 | Volume: 319 | Issue: 2 | Pages: No page available

10.1148/radiol.260149 | PMID 42117988 Get It

A framework for quantifying and leveraging uncertainty in pre-trained CT denoising model
Gong, Hao, Huber, Nathan R., Kharat, Shravani A., Koo, Chi Wan , Yu, Lifeng, Leng, Shuai, Hsieh, Scott S., McCollough, Cynthia H., Gong, Hao , Huber, Nathan R. , Kharat, Shravani, Fletcher, Joel G. , Yu, Lifeng , Leng, Shuai , Hsieh, Scott S. , McCollough, Cynthia H.

Mayo Clinic

IEEE Transactions on Biomedical Engineering | May 5, 2026 | Volume: No volume available | Issue: No issue available | Pages: 1-12

10.1109/tbme.2026.3690022 | PMID 42085391 Get It

Clinical benefits and current challenges of photon-counting detector CT in vascular imaging
Sadaney, Ahmed O El , Mark, Ian, Froemming, Adam T. , Baffour, Francis , Yu, Lifeng, Leng, Shuai, McCollough, Cynthia H, Leng, Shuai , El Sadaney, Ahmed O , Rajiah, Prabhakar Shantha, Campeau, Norbert G , Froemming, Adam T , Baffour, Francis I , Horst, Kelly K. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H , Fletcher, Joel G , Diehn, Felix E. , Rajiah, Prabhakar , Mark, Ian, Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Radiology Advances | April 14, 2026 | Volume: 3 | Issue: 3 | Pages: No page available

10.1093/radadv/umag021 | PMID 42254812 Get It

Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Pushing the limits of spatial resolution in clinical PCD‐CT using a dedicated high‐resolution convolutional neural network (HR‐CNN)
Zhou, Zhongxing, Bratt, Alex, Koo, Chi Wan , McCollough, Cynthia H., Yu, Lifeng, Bratt, Alex K, Horst, Kelly K. , Bratt, Alex , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Medical Physics | March 29, 2026 | Volume: 53 | Issue: 4 | Pages: No page available

10.1002/mp.70382 | PMID 41904700 Get It

Abstract Background Photon‐counting‐detector (PCD) CT systems offer ultra‐high spatial resolution, yet the visual spatial resolution on clinical images often constrained by large pixel size, yielding resolutions below system capabilities. While reducing pixel size and using sharp kernels enhance visual spatial resolution, it increases noise, compromising image quality. Purpose To investigate the combined effects of pixel size and reconstruction kernels on visual spatial resolution using phantom and clinical images and to develop a dedicated high‐resolution deep convolutional neural network (HR‐CNN) to better utilize the intrinsic high spatial resolution of PCD‐CT in clinical imaging. Methods The relationship between spatial resolution, reconstruction kernel, and pixel size was investigated to identify strategies for utilizing the full spatial resolution potential of PCD‐CT. To overcome the increased noise associated with high‐resolution settings, a dedicated HR‐CNN was developed to push the limit of spatial resolution in routine PCD‐CT exams. The HR‐CNN was trained using patient exams acquired with ultra‐high‐resolution (UHR) mode and reconstructed with a 150‐mm field of view (FOV), matrix size of 1024×1024 (0.15‐mm pixel size) and sharpest quantitative kernel (Qr89). The impact of FOV, kernel, and denoising on spatial resolution was studied using bar‐pattern phantoms and a pilot clinical evaluation including 5 patients with interstitial lung diseases. Two thoracic radiologists evaluated 4 different FOV/reconstruction conditions: (1) FOV‐410/Qr56‐Iterative reconstruction (IR), (2) FOV‐410/Qr89‐IR, (3) FOV‐150/Qr89‐IR, and (4) FOV‐150/Qr89‐HR‐CNN in terms of overall image quality, noise, visual spatial resolution, and overall preference. Results With a FOV of 410 mm, the Qr89 sharp kernel displayed bar‐patterns up to 14 lp/cm, not much higher than the routine lung kernel Qr56. When the FOV was reduced to 150 mm, Qr89‐IR allowed for the visualization of line pair patterns ranging from 18 to 20 lp/cm, with 20 lp/cm being moderately discernible. The application of Qr89‐HR‐CNN yielded further improvement, enabling the display of line pair patterns as high as 20–22 lp/cm. In patient cases, both radiologists consistently ranked the FOV‐150 images processed with HR‐CNN as superior across metrics including overall image quality, noise reduction, visual spatial resolution, and overall preference. The HR‐CNN reduced the noise in patients’ images by 93.0 ± 0.6% and 44.9 ± 5.3% in comparison with the original FBP and IR images, respectively. Conclusions The spatial resolution of PCD‐CT is not maximized in routine practice due to the large FOV and high noise levels at sharp kernels. The proposed HR‐CNN denoising method, along with small pixel size, may allow the high spatial resolution toward the system limit to be implemented in practice, which is beneficial in the diagnosis of many diseases, including interstitial lung disease.
CT data harmonization via learned virtual monoenergetic imaging for cross‐kV scan translation and radiomics reproducibility
Chang, Shaojie , Swicklik, Joseph R., Zhou, Zhongxing, Kharat, Shravani, Wellinghoff, Jarod , Gong, Hao , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, Gong, Hao , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Medical Physics | March 26, 2026 | Volume: 53 | Issue: 4 | Pages: No page available

10.1002/mp.70403 | PMID 41881591 Get It

Abstract Background Radiomics extracts quantitative imaging features from computed tomography (CT) data for clinical decision‐making. However, variations in acquisition parameters—particularly x‐ray tube voltage (kV)—introduce non‐biological variability in attenuation values, limiting the reproducibility of radiomic features across scanners, protocols, and institutions. Purpose To develop and evaluate a CT dAta harmoNiZAtion framework based on deep learNed vIrTual monoEnergetic imaging (TANZANITE), which leverages the keV flexibility of virtual monoenergetic images (VMIs) to enable cross‐kV scan translation and radiomics harmonization. Methods TANZANITE is a model hub consisting of multiple pre‐trained convolutional neural networks (CNNs), each designed to translate VMIs from 1 keV level to another. Phantom‐based calibration was first used to determine energy‐equivalent (Eff_E) keV levels corresponding to each tube potential (e.g., Eff_E(A) keV for source kV and Eff_E(B) keV for target kV). A CNN trained using 69 120 patches from seven patient cases to map VMIs from Eff_E(A) to Eff_E(B) was selected from the TANZANITE hub and applied directly to clinical CT images acquired at the source kV. This harmonized the images to match the attenuation characteristics of the target kV setting. Evaluation was conducted on independent dual‐energy CT datasets acquired at 100/Sn150 kV. Regions of interest (ROIs) were placed in the kidney, liver, and spine to assess CT number consistency and radiomic feature reproducibility. The concordance correlation coefficient (CCC) was calculated across 93 non‐shape radiomic features. Results After TANZANITE processing with 100 kV images, CT numbers in evaluated organs closely matched the Sn150 kV reference values in four testing patient cases. For example, mean kidney CT numbers changed from 320 HU (100 kV) to 156 HU (TANZANITE), approximating the Sn150 kV value of 160 HU. Similar changes were observed in the liver (157–105 HU vs. 104 HU reference) and spine (45–22 HU vs. 19 HU reference). Radiomic reproducibility improved substantially across organs: mean CCC increased from 0.590 to 0.995 in the liver, 0.300 to 0.970 in the kidney, and 0.630 to 0.968 in the spine. Post‐TANZANITE, over 98% of features exceeded the stability threshold (CCC ≥ 0.900) in all three representative organs. Conclusion TANZANITE provides a flexible, image‐domain harmonization framework by learning the keV‐to‐keV translation in the VMI domain and applying pre‐trained CNNs to clinical kV images. It improves CT number consistency and organ‐specific radiomic reproducibility without requiring raw projection data or scanner‐specific training. This approach supports consistent quantitative imaging across multiple‐kV acquisition protocols, enhancing radiomics reliability in clinical settings.
Deep Learning–based Monoenergetic Imaging for Calcified Coronary Stenosis Assessment at Energy-integrating Detector CT
Chang, Shaojie , Koons, Emily K. , Gong, Hao , Thorne, Jamison E. , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, McCollough, Cynthia H. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Williamson, Eric , Thorne, Jamison E , Gong, Hao

Mayo Clinic

Radiology: Cardiothoracic Imaging | March 19, 2026 | Volume: 8 | Issue: 2 | Pages: No page available

10.1148/ryct.250230 | PMID 41854396 Get It

A deep learning–based neural network enabled virtual monoenergetic imaging at energy-integrating detector CT, reduced blooming artifacts, and improved stenosis assessment in heavily calcified coronary plaques, with performance comparable to ultrahigh-resolution photon-counting detector CT.
Reduced-Dose Chest CTA for the Detection of Pulmonary Arteriovenous Malformations in Pediatric Patients With Hereditary Hemorrhagic Telangiectasia
Saadeh, Zaid , Demirel, Nadir , Koo, Chi Wan , Oo, Daniel W. , Tandon, Yasmeen K. , Thorne, Jamison E. , Zhou, Zhongxing , Yu, Lifeng , Hull, Nate C., Oo, Daniel, Horst, Kelly K. , Iyer, Vivek , Larson, Nicholas B. , McCollough, Cynthia H. , Yu, Lifeng , Hull, Nathan C.

Mayo Clinic

Journal of Computer Assisted Tomography | October 15, 2025 | Volume: 50 | Issue: 2 | Pages: 254-262

10.1097/rct.0000000000001804 | PMID 41091128 Get It

Objectives: To determine the feasibility of reduced-dose chest computed tomographic angiography (CTA) with convolutional neural network (CNN) denoising for detecting pulmonary arteriovenous malformations (pAVMs) in children with hereditary hemorrhagic telangiectasia (cwHHT). Methods: Fifteen cwHHT underwent a chest CTA (ie, a controlled “study” dose). Noise was inserted to simulate a quarter dose (QD) exam. Images were reconstructed using iterative reconstruction (IR) and our self-trained CNN denoising model. For each case, 3 sets of images were created: study dose (SD)+IR, QD+IR, and QD+CNN. Two thoracic radiologists independently scored each set to assess quality, spatial resolution, artifacts, and the presence of pAVMs using 4-level ordinal scales. Quantitative assessments of image quality were performed using contrast-to-noise ratios (CNRs) with comparisons made between the experimental conditions. Results: Thirteen of the 15 patients recruited with hereditary hemorrhagic telangiectasia (mean age: 9.3±4.5 y) were positive for pAVM by transthoracic contrast echocardiography. The sensitivities using QD+CNN were 0.85 and 1.00 for readers 1 and 2, respectively. This was compared with 0.69 and 0.84 using QD+IR versus 0.85 and 0.92 for SD+IR. Inter-reader agreement for pAVM detection utilizing QD+CNN was moderate and resulted in kappa=0.59 ( P =0.012). The subjective assessments for QD+CNN were comparable to the SD technique. Regression analysis of reader scores revealed improved quality in QD+CNN versus QD+IR ( P =0.001). Similarly, the QD+CNN condition demonstrated the highest CNRs. Conclusions: Reduced-dose chest CTA with CNN denoising provides a level of sensitivity comparable to standard dose CTA and high CNRs for the detection of pAVMs in cwHHT.